Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
19 Jun 2021, 12:00 pmClosed
The Director
75,santhome high road,R.A.Puram,Chennai-28
e tender for the work Providing panel board and cable laying along with required electrical provisions for ponds at Kovalam Experimental Station of CIBA Kelambakkam
2021_DARE_632645_1
CIBA/ 1-1/2021-22/EC/KES
Open Tender
Electrical Works
Works
45 days
KES of CIBA Kelambakkam
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
6 Jul 2021
5 Jun 2021
21 Jun 2021
5 Jun 2021
19 Jun 2021
5 Jun 2021
5 Jun 2021 - 19 Jun 2021
Amount
ELECTRICAL WORK:
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required i) 2 X 1.5 sq mm + 1 X 1.5 sq mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required i) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required i) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing 125 amps, 415 volts, TPN SDFU with sheet steel enclosure, on surface, i/c HRC Fuses with connections, testing and commissioning etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required) 4 way (4 + 12), Double door
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. i).63 amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i).Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. i).Triple pole
Supply of following size ISI Marked Cross linked polyethylene (XLPE) insulated, PVC outer sheathed with galvanized steel strip cables with aluminium conductor suitable for rated voltage of 1100 Volts grade and conforming to IS: 7098(pt.I)1988 with up to date amdts. and of the following size. i) 31/2 X 95 sqmm
Supply of following size ISI Marked Cross linked polyethylene (XLPE) insulated, PVC outer sheathed with galvanized steel strip cables with aluminium conductor suitable for rated voltage of 1100 Volts grade and conforming to IS: 7098(pt.I)1988 with up to date amdts. and of the following sizes. i) 31/2 X 50sqmm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trenchetc. complete as required i) 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trenchetc. complete as required i) 90 mm dia (OD-90 mm & ID-76 mm nominal)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. i) 31/2 X 95 sqmm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required. i) 31/2 X 50 sqmm
Earthing with G.I. earth pipe 3 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying and fixing of 50 mm dia 1.50 Mtrs long GI pipe for cable protection along with suitable clamps bent to shape for free entry of U.G.Cables etc. as required.
Fabrication, Installation testing and commissioning of Floor mounting outdoor type (IP55) Starter Panel board made-up of 2mm thick CRCA Sheet, powder coated, with suitable size viewing Glass with the following specifications : a) size not less than 700mm L x1000mm H x250mmD b) 750mm Long Base Frame made-up of 40m x 40mm x6mm Angle iron c) Bottom Cable Entry d) 63 Amps TPN SDFU -1 No Incomer e) 32 Amps TPN MCB - 2 Nos Outgoing f) DOL Starter 9 - 14 Amps ( MK - 1) - 2 Nos g) RYB indication Lamps LED - 1 set h) 6 Amps control MCB's - 1 set i) Suitable angle support - (3M depth & 30cm dia below the ground level with concrete foundation)
Supply, installation, testing and commissioning of 40W LED Street light fitting with IP 65 protection with built in integrated driver complete with all accessories including 25 mm dia 'B' class GI Pipe bracket made out of 25mm dia on wall by making necessary weldings i/c loop earthing 3 X 1.5sqmm PVC insulated copper conductor cable from street light box to fittings, etc,. as required.
Supplying, installing, testing and commissioning of pre wired 1 x 20 LED battern type fittings of size 4 feet complete (efficiency should be not less than with electronic drive and all accessories i/c lamps directly on existing ceiling/wall including connection etc. as required
GST for all the above items in percentage has be given in the cell-M37 and GST amount will be calculated automatically in Cell-BA37.
Bhavani Electricals
OM SAKTHI ENGINEERING WORKS
GRM ENTERPRISES
WINTECH ENGINEERING SERVICES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .