Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹22.6 LQualified Make: Aquaguard
Model: AQUAGUARD & AG 80 SS GREEN CHILL PURE RO + UV WATER COOLER 7 CHAKRABERIA ROAD SOUTH BHAVANIPUR KOLKATA WEST BENGAL 700025 | KOLKATA | WEST BENGAL | 700025 | Make: Aquaguard
Model: AQUAGUARD & AG 80 SS GREEN CHILL PURE RO + UV WATER COOLER | ₹22.6 L | L1 | Qualified |
| 2 | L1₹22.6 LQualified Make: EUREKA FORBES LTD(AQUAGUARD)
Model: eureka forbes ltd and ag pure chill 80pss 00 SETHIYAPARA MAGANPUR AMAGUDA JAGDALPUR BASTAR CHHATTISGARH BASTAR CHHATTISGARH 494001 | BASTAR | CHHATTISGARH | 494001 | Make: EUREKA FORBES LTD(AQUAGUARD)
Model: eureka forbes ltd and ag pure chill 80pss | ₹22.6 L | L1 | Qualified |
| 3 | Disqualified Make: Eureka Forbes (Aqua Guard)
Model: AQUAGUARD REVIVA BASIC 50 LPH 128 E 181 BLOCK NR NAGAR NIGAM ZONE 3 OFFICE KIDWAI NAGAR KIDWAI NAGAR KIDWAI NAGAR KANPUR NAGAR UTTAR PRADESH 208011 | KANPUR NAGAR | UTTAR PRADESH | 208011 | Make: Eureka Forbes (Aqua Guard)
Model: AQUAGUARD REVIVA BASIC 50 LPH | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
11 Jun 2018, 2:00 pmClosed
Potable water purification system Potable Water Purification System ( 26 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier Ultraviolet (UV) LAMP Yes Yes Ultra Voilet (UV) Lamp power consumption 8 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 2 2 INPUT PARAMETERS Input Water TDS 2000 1000
2000
3000
4000
5000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 30-40 25-35
30-40
90-100
70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - Output water capacity (Litre/Hour): 50 50 Arsenic and Floride true 1/3 removal capability Misc
warranty etc Thin-film composite membrane Yes Yes
No High Pressure Pump No - Raw water/Chemical Raw water/Chemical Cleaning PUMP No Yes
No Pre Filter Vessels: Yes Yes
No Micron Filter Yes Yes
No Membrane Housing Yes Yes
No Auto cut Yes Yes No of candles (Nos) 4 4 Installation Type Floor mounted Floor mounted Warranty period ( for free replacement of machine 2 2
3
1 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2
1 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes Yes
No Chloride & Flouride removal facility No Yes with Pump
Yes without pump
No Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 - - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Avijit Seal 700002
Gun Foundry Road
P.O. Cossipore 26 15 EMD 2/3 Required No ePBG Required No
151075
GEM/2018/B/21553
Potable water purification system
15 days
West Bengal; Kolkata
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Potable water purification system Potable Water Purification System ( 26 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier Ultraviolet (UV) LAMP Yes Yes Ultra Voilet (UV) Lamp power consumption 8 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 2 2 INPUT PARAMETERS Input Water TDS 2000 1000 | - | - | - |
| 2000 | - | - | - |
| 3000 | - | - | - |
| 4000 | - | - | - |
| 5000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 30-40 25-35 | - | - | - |
| 30-40 | - | - | - |
| 90-100 | - | - | - |
| 70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - Output water capacity (Litre/Hour): 50 50 Arsenic and Floride true 1/3 removal capability Misc | - | - | - |
| warranty etc Thin-film composite membrane Yes Yes | - | - | - |
| No High Pressure Pump No - Raw water/Chemical Raw water/Chemical Cleaning PUMP No Yes | - | - | - |
| No Pre Filter Vessels: Yes Yes | - | - | - |
| No Micron Filter Yes Yes | - | - | - |
| No Membrane Housing Yes Yes | - | - | - |
| No Auto cut Yes Yes No of candles (Nos) 4 4 Installation Type Floor mounted Floor mounted Warranty period ( for free replacement of machine 2 2 | - | - | - |
| 3 | - | - | - |
| 1 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2 | - | - | - |
| 1 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes Yes | - | - | - |
| No Chloride & Flouride removal facility No Yes with Pump | - | - | - |
| Yes without pump | - | - | - |
| No Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 - - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Avijit Seal 700002 | - | - | - |
| Gun Foundry Road | - | - | - |
| P.O. Cossipore 26 15 EMD 2/3 Required No ePBG Required No | - | - | - |
Exempted
11 Jun 2018
30 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_151075.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .