| 1 | L1₹12.7 LAccepted-AOC VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹14.6 L+₹1.6 L (12.4%)Rejected-Finance GROUND FLOOR SUIT NO 2 SARITA APARTMENT KHARIDA MAIN ROAD KHARAGPUR 721 301 DIST PASCHIM MIDNAPORE WEST BENGAL | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721301 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹14.9 L+₹1.9 L (14.9%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹16.3 L+₹3.4 L (26.0%)Rejected-Finance VILL SAROT PALLY PO SANKRAIL DIST HOWRAH PIN 711313 WB | SANKRAIL | HOWRAH | WEST BENGAL | 711313 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹17.6 L+₹4.6 L (35.5%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
1 Jul 2021, 6:00 pmClosed
GE (AF) Kalaikunda
GE (AF) Kalaikunda
REPAIRS TO STREET LIGHTS , FLOOD LIGHTS , POLE PAINTING AND ALLIED WORKS IN TECH AREA AND DDK RANGE AT AIR FORCE STATION KALAIKUNDA UNDER GE (AF) KALAIKUNDA
2021_MES_448675_1
8670/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Kalaikunda
as per nit
6 documents required · 6 mandatory
₹500
GE (AF) Kalaikunda
₹40,000
Yes
9 Aug 2021
5 Jun 2021
3 Jul 2021
5 Jun 2021
1 Jul 2021
19 Jun 2021
Amount
Taking down defective light fitting of 4 x 14 watt / 36/40 /60/75/150/250/400 Watt SV/MH Street light, security light, CFL/ Flourecent Tube light fittings (any type and any size), Flood light, LED light any type, from any location mounted on any type of poles/bldgs/ tower/ high mast / Blast pan of up to 18 Mtr height including all necessary scaffolding complete after disconnecting of supply cable for replacement of fittings all as specified and directed by Engineer in charge. Note : (i) Any T& P required for the work shall be arranged by the contractor.(ii) It is mandatory that contractor shall submit the insurance certificate minimum 10 Lakh sum assured of all staff/employee employed by him for the work services.
S & F LED street lights nominal power 60 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 6000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-671-XXX-57-XX of Wipro or equivalent of Make mentioned under Particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F LED flood lights nominal power 200 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LF20-272-060-57-XX of Wipro or equivalent of Make mentioned under particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F LED flood lights nominal power 120 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LF20-132-060-57-XX of Wipro or equivalent of Make mentioned under particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
Note for Item No. 2 to 4 :- (i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length shal be paid seperately under respective items. (ii) At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt. (iv)All LED lights have replacement warranty of 3 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receiving of 3 year replacement warranty certificate. (v) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly. (vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries. (vii) All LED fitting shall be identified by printing or fixing stickers duly mentioned the C.A number and date of completion. (viii) For any change in product or change in catalogue No. etc due to technological upgradation, letter has to be obtained from the lighting company on their letter head signed by an offical of National level. (ix) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor .
Taking down unserviceable street /flood light / Security light fittings any type or any capacity from any location mounted on any type of Poles/Bdgs/ Blast Pan / Tower/ High mast of height up to 18 mtr from bracket after disconnecting of supply cable and refixing the same after carrying out repair and testing on exiting or new location as per site requirement, including repairing of circuit, electrical connection, replacement of defective driver, surge protection device, tracing and rectifying of fault complete all as specified and as directed by Engineer-in-Charge. Note : (i) Supply only LED driver with SPD and electric supply cable will be measured and paid separately under respective item.) (ii) All T&P, ladder etc required at site for the repairing and taking down / refixing of light fitting after repair shall be arranged by the contractor. (iii) If there is any fault in electrical supply line, it shall be contractor liability to identify the fault and get it repair for making the light functional.
Supply only in repair LED driver suitable for 25 watt LED light , 240 Volt , 50Hz , AC . Make of Driver : Bajaj /Crompton/ C&S/ Havells/ Surya/Philips/wipro (As per existing) Note :(i) Before procurement contractor shall check the make and model of u/s LED driver as per existing and bring the same or suitable to make the light functional.
All as per item No.6 here-in-before but for 60 watt LED light fittings as per existing specification complete all as specified and as directed by Engineer-in-Charge. Make : Bajaj /Crompton/ C&S/ Havells/ Surya/Philips (As per existing)
All as per item No.6 here-in-before but for 100/120 watt LED flood light fittings as per existing specificationcomplete all as specified and as directed by Engineer-in-Charge. Make : Bajaj /Crompton/ C&S/ Havells/ Surya/Philips (As per existing)
All as per item No.6 here-in-before but for 200 watt LED light fittings as per existing specification complete all as specified and as directed by Engineer-in-Charge. Make : Bajaj /Crompton/ C&S/ Havells/ Surya/Philips
Note for Item No. 6, 7 and 8 above: (i) Before procurement contractor shall check the make and model of unserviceable LED driver as per existing specification and approval shall be obtained from Engineer-incharge
S & F in repair Thermoplastic cable junction box of size 205 mm x 255 mm x 112 mm , IP 66 , halogen free and weather proof with locking arrangement and necessary mounting arrangement on pole by providing MS clamp with nut , bolt and double washer , for out door installation complete with connector terminal for connecting cable, knockouts for cable entry up to the size of 25 Sqmm x 4 core, including taking out / dismentaling existing u/s junction box of any type and size , disconnection of existing cable connection and reconnection of cable by providing suitable size cable lugs and PVC glands complete all as specified and directed by Engineer-in-charge. Make:- Hensel Cat No-KF2525B or equivelent in Sintex / C&S as approved by GE. Note : Contractor shall provide cable lugs and PVC gland of suitable size if required on site for connecting cable in junction box.
S& F in repair for Digital time switch (2 Module), 240 Volt AC 50 Hz, having feature for time programming for daily/ weekly , Pluse switching, reset feature, LED for relay On indication, 24 Hrs display , Manual override including making all electrical connection to make the timer functional as per time set for auto ON/OFF of street lights complete all as specified and directed by Engineer-in-Charge including taking out old u/s times switch. Make: L&T Cat No:-AUTS02DIG00 or equivalent in Legrand/Schinder/Havells.
Taking out old unserviceable contractor and S&F 3 Pole Power contactor Type MO 40 , of 40 Amp , having (AC 3 Rating 40 Amp and AC 1 rating 55 Amp), 415 volts, AC, 50 HZ, 3 pole, including making all electrical connections by providing lugs etc complete all as specified and as directed by Engineer-in-Charge . (Make :L&T Cat No - CS94569 or equivalent in Legrand / Schinder as approved by GE.)
M&L for PVC insulated,PVC Sheathed flat twin core 2.5 Sqmm solid aluminium conductor cable for connection of security light from junction box or existing source to light fitting to be drawn through conduit/pipe along the pole or through inside the street light pole or over head line/existing source to street light fittings etc , including taking out old u/s wires complete all as specified and as directed by Engineer-in-Charge. Note : PVC Conduit shall be measuerd and paid seperately under respective item.
S & F Non metallic PVC medium grade conduit 20 mm dia, ISI marked for drawing aluminium/ copper conductor cable between pole junction box and light fitting including fixing clamp made of GI strips and nut and bolts (Minimum 3 clamp in each pole to be provided.) including taking out old unserviceable complete all as specified and directed.
Taking out old unserviceable cable from trenches or any location of any size complete all as directed by Eng in Charge.
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade, ISI marked, with valid CML No. of stranded aluminium conductor of size 25 sqmm 4 core, laying in undergound in trenches or on surface by providing proper GI clamps or in protection pipe including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends. Make: Polycab/ Havells/Gloster
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade, ISI marked, with valid CML No. of stranded aluminium conductor of size 16 sqmm 4 core, laying in undergound in trenches or on surface by providing proper GI clamps or in protection pipe including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends. Make: Polycab/ Havells/Gloster.
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade, ISI marked, with valid CML No. of aluminium conductor of size 10 sqmm 2 core, laying in undergound in trenches or on surface by providing proper GI clamps or in protection pipe including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends. Make: Polycab/ Havells/Gloster
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out all as specified and directed. Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/ per day will be charged to contractor till rectification of defects. In this aspect GE decision will be final , conclusive and binding.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of any kind of soil all as specified and directed.
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and directed.
M & L sand filling in-trenches with clean dry sand unwashed including gently pruning around cables complete all as specified and directed by Eng in Charge. Note:-Punned thickness to be measured for payment.
Supplying and laying unrainforced precast concrete cable cover, laid flat dry, laid perpendicular to the length of the under ground cable trenches for cable protection complete for following sizes (a) Class LV, Type -1 Flat as per IS 5820 of size 250 mm x 150 mm x 40 mm
M&L for laying 40 mm bore GI pipe, light grade with all fittings, in crossing road/path and in pole up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge.(Note : Boring under road/path will be measured and paid under respective item )
M&L for laying 50 mm bore GI pipe, light grade with all fittings, in crossing road/path and in pole up to junction box including necessary clamping etc. complete all as specified and as directed by Engineer-in-Charge.(Note : Boring under road/path will be measured and paid under respective item )
M&L for boring of road for laying up to 80 mm dia GI pipe medium grade complete all as specified and as directed by Engineer-in-Charge.
M & L Painting of steel pole (swan neck type or straight type) up to 12 mtr height with cross arms, clamp of any length and shape for LT overhead line/ for street light with two coat of aluminium paint after scraching out old paint, cleaning and exiting surface rust free, preparation of the existing surface, including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ Stricker, including painting strips in alternate from bottom to top with three strips of black syenthatic paint & two strips of Yellow/ Sky blue paint (as per existing pattern through out the circumference of pole, including removing extra wall papdi ,peel off wall papdi by sand paper and making good with putty as per existing thickness and applying one coat of white washing on PCC copping of pole complete all as specified and directed.
M & L Painting to the LT PCC poles with strips in alternate from bottom to top with three strips of black synthatic paint & two strips of Yellow/ Sky blue paint (as per existing pattern) through out the circumference of pole including one coat of lime wash on PCC copping of pole , two coat of white colour cement base paint on pole and two coat of aluminium paint to channels, cross arm, clamps and pipes fixed/ mounted on pole after scraching out old paint, cleaning and making exiting surface rust free, preparation of the existing surface, including marking pole numbers in a 15 cm dia yellow circle with number writting with black syenthic paint/ stricker complete all as specified and directed.
Supply & Fix in repair MCB 16 Amp, Double Pole (DP) ,10KA , AC, 50 Hz , `C` Curve including taking out old U/s MCB. Make L&T Cat No. BB20160C or equivelent in Schinder/ C&S.
Supply & Fix in repair MCB 32 Amp, Triple Pole (TP) ,10KA ,AC,50 Hz , `C` Curve complete all as specified and directed.. Make L&T Cat No. BB30320C or equivelent in Schinder/ ABB.
M & L for Tree trimming around 5 mtr around existing overhead line, removing of vegitation and bushes between one span (2.5 Mtr both side , distance between span pole to pole max 25-50 mtrs to be consider as one span) complete all as specified and directed by Enginner-In-Charge. Note:- (i) Contractor has to trim and punning of tree to be done falls in span between pole to pole. (ii) Necessary survey of site to be done before quoting the rate. If required JCB to be used for clearing the vegitation on the rout of overhead line. (iii) Due to speedy growth of trees/ branches punning / trimming to be done in perodicity as required irrespective of location. Location can be repeated as per the requirement and measured as per work done. (iii) After tree punning disposal of branches and kept in stack at the site (within 100 mtrs) directed by Eng in charge shall be done by the contractor.
Taking down existing Avaition light from transmitter tower/ hangar / technical building / ATC and any location upto 25 mtrs height and supply and fixing LED Integral avaition light comprising of aluminium housing with polycarbonate enclouser, 240V AC, 50Hz including all electrical connection as required at site complete all as specified and directed by Engr-In-Charge .Make Crompton Cat No:-GLN 703 LED or equivelent in Wipro /Havells / Philips as approved by GE. Note - Through there is stairs/rungs to reach the terrace of bldg /Roof of Hangars but any additional T&P required on site for fixing avaition light, it shall be arranged by the contractor.
Supply & fixing in repair Thermoplastic box (enclosure only) of size 300 x 450 x 214 mm out door type, IP 65 made of polycarbonate fully UV ray protected, to be fixed on location as directed by providing all hardwares as required at site, The box shall fixed with DIN Rails suitable for installation of timer , contractor & MCB and other electrical acessories of Timer switch for auto ON /OFF of street light and making all electrical connection complete including taking down old u/s all as specified and directed by Engineer in Charge. Make : Hensel Cat no:- Mi 9311 or equivelent in Sintex / C&S Note : (i) Electrical accessories like Contactor , MCB , Time switch will be measured and paid separately under respective items (ii) Contractor has to fixed all the accessories in box and wiring and electrical connection to be done to make the timer switch unit for Auto ON/OFF of street light.
Supply & fixing in repair Auto timer switch for auto ON/ OFF of street lights in sheet steel enclosure, including all accessories like contactor, digital timer switch , MCB, pre wired, of 40 Amp , 3 Pole, 230 Volt, digital timer switch including making all electrical connections , fixing of timer switch box by providing all hard ware as required commplete all as specified and directed by EnginEer in Charge. Make : INDOASIAN Cat no:- TL040DB0, TIMELITE DISTRIBUTION BOARD equivelent C&S/ Havells.
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing , floor mounting ,dust and vermin proof, cubical type LT panel fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 320 Amps ( Size of copper strip should not be less than 40 x 6 mm for each phase and neutral) pre-wired with suitable size of copper strip/ copper wire with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands , cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box / LT Panel with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 450 mm height above ground level all as specified with supply and fixing the following. (A) Incoming (i) MCCB 160 Amps rating, 4 pole C-curve,415 V, AC, 50 HZ, thermal release range 125-160 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 36 kA --- 01 Nos with rotatary handle. Make of MCCB L&T, Cat Part No. CM92108OOM1OG (ii) Digital Ammeter---01 Nos with Suitable CT and wiring. (iii) Digital Voltmeter - 01 No (iv) Three indication lamp (v) Slector switch - 2 Nos
(B) Outgoing (i) MCCB 63 Amps rating, 4 pole ,C-curve ,415 V, AC, 50 HZ, thermal release range 80-100 Amp with adjustable overload setting and , short circuit setting, Ics-100 % Icu , service breaking capacity 25 kA - 02 Nos with rotatary handle. (ii) MCB 40 Amp (TPN ), ultimate breaking capacity 10 KA , C curve - 02 No (iii) MCB 25 Amp SPN/ Double Pole (DP) , ultimate breaking capacity 10KA , C curve - 01 No Note:- (i) All MCCB/MCB should be of Make : L&T/ABB/Schnider. (ii) Drawing of LT panel and make of items to be got approved from GE before ordering the panel. (iii) Cost of lugs for cable and cable gland etc also included in unit rate of panel. (iv) Cost included taking out existing cable from old panel and refixing and connecting to new panel.
Taking down existing post top lantern from any gate post and supply and fixing LED post top lantern light made in aluminium with decorative opal polycarbonate diffuser with IP-65 protection with all electrical connection fixing arrangement as required at site complete all as specified and directed by Engr-In-Charge .Make Bajaj Cat No:-BGCT W4 LED WW or equivelent in/ Crompton/ Havells / Philips as approved by GE.
M&L for Flexible PVC insulated multicore FR PVC sheathed multistranded copper conductor cable of 1.5 Sqmm x 3 core for voltage grade up to 1100 V conforming to IS 694 : 2010 for connection of light fitting from junction box or from over head conductors to fitting complete all as specified and as directed by Engineer-in-Charge. Note : PVC Conduit shall be measuerd and paid seperately under respective item.
M&L for Numbering of street light pole (marking pole numbers) on any type of steel / RCC pole in a 15 cm dia yellow circle painted with syenthic enamel paint with number writting with black syenthic paint/ Stricker as directed by Engineer in Charge.
S&F thermoplastic circuit breaker box , IP 65, having 1 x row 3 modules, of size 102 x 197 x 92 mm with knockouts for cable entry and DIN rail for mounting MCB, with PE+N terminals including taking down old u/s complete all as specified and directed by Eng in Charge.Make : Hensel Cat Part No. KV 7013 or equivalent in Sintex / C&S.
S & F Straight through joint, heat shrink, suitable for LT under ground cable of size 25 Sqmm x 4 core, of range ( 25-50 Sqmm) including all accessories, ferules etc complete all as specified and directed by Engineer-In-Charge.Make : Birla / 3M/ Rychem
S & F Straight through joint, heat shrink, suitable for LT under ground cable of size 16 Sqmm x 4 core, of range ( 6-16 Sqmm) including all accessories, ferules etc complete all as specified and directed by Engineer-In-Charge.Make : Birla / 3M/ Rychem
M&L for earthing complete with galvanised steel earth plate electrode size 600 x 600 x 6 mm thick, burried directly in ground, (Earth pit not less than 3.25 m deep below ground level) with top edge of the plate not less than 2.5 m below ground level connected to galvanised iron strip 32 x 6 mm as earthin lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion, surrounded from all sides by mixture of charcoal and common salt and electrode by means of steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified NOTES 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 7.5 meter above ground level. NOTE:- 1. The unit rate includes for protection GI pipe of 40 mm and watering pipe of 20 mm bore including excavation for earth pit in any type of soil/ disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high. 3.The cost of GI strip of size 32 X 6 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in GI strip and connection with Earth Plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5. Cost of welding and nut bolts are deemed to be included in the unit rate.
Supply and replace 32 mm x 6 mm GI strip as in earth continuity conductor fixed to wall or pole or recess or cheses or burried in ground or drawn in conduit pipe or any other indicated situation for loop earthing etc as required all as directed
Supply and fixing in repair solar street light fitting of 18 watt LED type, efficacy 110 Lumen per watt, IP 65, fully automatic on / off, on with following option - in a light full light duration 4 hours, 60% light next 4 hours duration and 30 % light for next 4 hours duration( total 12 Hrs duration) with inbuilt lithium ferro Phosphate battery (LiFe Po4) of capacity 12 volt, 18 AH including in built control system. With feature of glare free, flickering and UV, full protection against open circuit, accidental short circuit and reverse polarity, with charging indicator , fuse for protection against short circuit, including making all electric connections with solar panel to make the light functional complete all as specified and directed by Engineer in Charge
Labour for attending the complaint of non functioning of street light / flood light /security light fitting of any type due to minor fault, deposition of oxidation on conductors at connection , Joints, junction by removing the oxidation , rectifying the fault and making the light functional complete as directed by Eng in Charge.
Note for Item No.45 :- (i) Contractor has to collect the complaint from AGE E/M office (from concern JE) on every working day in morning and submit the completion report/ feed back on same day in evening. (ii) Contractor shall attend the Complaint related to non functional of Parameter lights and dispersal lights on priority and make it functional on same day. If any complaint not attended due to unavailibility of spares, the same should be brought in notice of Eng in Charge immediately. (iii) Panalty of Rs 50/- per complaint per light will be imposed if contractor not attended the complaint of perimeter and dispersal lights within 24 Hrs. Decision of GE in this respect will be final. (iv) T&P required for work shall be arranged by the contractor. (v) Due to humdit claimate and dew in winters oxidation formation on joints/ connection is measure issue in these region therfore , If the complaint of light fitting attended under item No. 5 above and if it became non fuctional due to oxidation formation on connection / any minor fault within a period of three months from the date of repair and stiuation permitted then it will be again measured in item No.43, but for this date wise repair record duly signed by AGE E/M to kept and maintained by the contractor. (vi) Complaint attended and measured under item no 43 if repeated in a period of three month, contractor shall attend it without any extra cost. (vii) Contractor shall to provide complaint slip (in dupicate) and maint the record. Cost of complaint slip is deemed to be included in unit rate of item.(Viii) It is mandatory that contractor shall submit the insurance certificate minimum 10 Lakh sum assured of all staff/employee employed by him for the work service
General Note: Being mainteaince contract location for fixing of new light fittings and other repairs will be given to contractor on receiving of complaints or as when and on required basis and not in one span. Contractor shall not ask for hand over the complete site at one time.
Lotas Engineers
SENCO
M/s Santosh Industrial Corporation
Ganguly Construction
SRI HARSHITA ELECTRICALS
M/S C C CONSTRUCTION
NATIONAL CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .