Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAccepted-AOC NO 15 PULAVAR GOVINDAN STREET GANDHI NAGAR AVADI CHENNAI 600 054 | AVADI | CHENNAI | TAMIL NADU | 600054 | ₹2.1 Cr | L1 | Accepted-AOC REASONABLE LOWEST BIDDER |
| 2 | L2₹2.2 Cr+₹6.0 L (2.88%)Rejected-Finance | ₹2.2 Cr+₹6.0 L (2.88%) | L2 | Rejected-Finance not being lowest bidder |
| 3 | L3₹2.4 Cr+₹30.6 L (14.6%)Rejected-Finance 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | ₹2.4 Cr+₹30.6 L (14.6%) | L3 | Rejected-Finance not being lowest bidder |
| 4 | Rejected-Technical NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | - | - | Rejected-Technical BEARING ADVERSE REMARKS IN WLR QE JUN 2023 FOR ADG(P) CHENNAI, NOT UPLOADED DD TOWARDS COST OF TENDER AND NOT SUBMITTED IP |
| 5 | Rejected-Technical | - | - | Rejected-Technical NOT SUBMITTED IP |
Tender Value
₹2.3 Cr
EMD Value
₹3.0 L
Closing Date
13 Nov 2023, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND PICKETSECUNDERABAD
SPECIAL REPAIRS TO ENGINE DIVISION BUILDING NO P71 IN TECH AREA AT CVRDE AVADI
2023_MES_620623_1
83230
Open Tender
Civil Works
Item Rate
365 days
AVADI CHENNAI
AS PER NIT
8 documents required · 8 mandatory
₹2,000
AGE I RND AVADI CHENNAI
₹3.0 L
Yes
22 Feb 2024
26 Sept 2023
20 Nov 2023
26 Sept 2023
13 Nov 2023
30 Oct 2023
27 Sept 2023 - 10 Oct 2023
Amount
Demolition of cement concrete (un reinforced) in floors n exe 15 cm thickness complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth , wall tilling or skirting including cement mortar and backing coat complete all as specified and as directed by the Engineer-in-Charge.
M&L Cement concrete 1:4:8 typeD-2,(40mm graded aggregate) as mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M/L PCC 1:2:4 type B-1using 20mm graded aggregate in levelling course 40mm thick in floors complete all as specified and as directed by the Engineer-in-Charge.
M/L PCC 1:2:4 type B-0using 12.5 mm graded aggregate in levelling course 25mm thick in floors complete all as specified and as directed by the Engineer-in-Charge.
M&L screed bed or bedding layer of mortar 15mm thick for laying floor finishes with CM 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L Vitrified ceramic tiles 10mm thick (Square/rectangular) polished , area of each tiles n.exc 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured epoxy solution (first/premium quality) to match complete all as specified and as directed by the Engineer-in-Charge.
M&L Dark shade/Double Charged/ultrachraged vitrified ceramic tiles, 10mm thick (square/rectangular), polished, area of each tile exceeding 0.36 sqm but not exceeding 0.42 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured epoxy solution (first/premium quality) to match complete all as specified and as directed by the Engineer-in-Charge.
All as per ser item No 7 & 8 above but vertical surface using vitrified tiles to match over clour of Light colour/Dark shade/Double Charged/ultracharged such as skirting,dados and risers to steps and fixed over rendering 10mm thick with CM 1:3 for skirting complete all as specified and as directed
M&L Hydraulic pressed chequered cement concrete colour tiles 300mmx300mmx 25mm, set, jointed and pointed in thick neat cement slurry in floors and pointed with white cements and pigments complete all as specified and as directed
M&L Non skid coloured ceramic tiles 7 to 8mm thick area of each tiles (square/ rectangular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
M&L Glazed coloured ceramic tiles in vertical surfaces 450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in CM 1:4 complete all as specified and as directed
M&L Granite galaxy 20mm thick factory made polished fixed with cement slurry pointing with coloured pigment to match the granite including cutting to shape, grinding, polishing, bulnosing etc in floors complete all as specified and directed by the Engineer-in Charge.
M&L Granite galaxy 20mm thick factory made polished fixed with cement slurry pointing with coloured pigment to match the granite including cutting to shape, grinding, polishing, bulnosing etc in skirting/dado and in stair steps, jambs, pillars, window- cills, cooking platforms, Wash basin R.C.C Slab, wall lining (veneering to wall) including 15mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by the Engineer-in Charge.
Stainless Steel railing upto1.0m height with modular passivated stainless steel 'weld free' railing system at suitable locations and at all levels of approved size and shape conforming to grade AISI 304 with necessary components using expansion and ball socket jointing system consisting of top handrail SS tube dia 50mm X 1.6mm thickness, single vertical balusters of 40mm dia round pipe of 1.6mm thickness fixed with base plate of 100X6 mm at 1 m to 1.2 m C/c and at turning with mid rail of four Nos SS tube dia 19mm and 1.6mm thickness which shall pass through connectors, in grit satin or mirror finish. The baluster shall be fixed on the horizontal or vertical surface as directed (Base plate shall be anchored to wall by 2 nos. M-10 dash fasteners with SS dome nuts, which shall be covered by SS plate). The entire SS railing and fixing shall be as per approval of Garrisson Engineer, complete all as specified and directed. Note :- AISI 304 steel must have chemical composition by weight as C - Max 0.08%, Cr - 18% to 20%, Fe - 66,345% to 74%, Mn - Max 2%, Ni - 8% to 10.5%, P - Max 0.045%, S - Max 0.03%, Si - Max 1% Make :- Hardwyn / Ozone or equivalent make as approved complete all as specified and directed by the Engineer-in Charge.
Chipping the cracked / loose concrete portion using proper tools like hammer, chisel etc. and removing the loose particle completely duly cleaning it with wire brush and removing the dust etc. complete until to reach sound good concrete surface and deeping the surface dry and removing the debris and dumping the same at the nominated locations as directed by the Engineer in charge with all lead and lift etc. (All labour, materials, tools and plants are to be supplied by the contractor only at his own cost) complete all as specified and directed by the Engineer-in Charge
Removing the existing deteriorated reinforcement and supply and placing of new cold twisted CRS bars including cutting, bending and straightening and placing in position complete in all levels and if necessary welding the new bars with the exg. Rods by over lapping with all lead and lift etc. complete and as directed by the Engineer in charge. (All labour, materials, tools and plants are to be supplied by the contractor only at his own cost) complete all as specified and directed by the Engineer-in Charge
Removing the loose particles rust / mill scale deposits completely duly Cleaning it with wire brush / crush sheet etc. and removing the dust etc. Complete over the old concrete surface and supply of zinc rich epoxy primer ie. FOSROC NITOZINC PRIMER/ BOSTIC ZRP/ DR. FIXIT ZINC RICH PRIMER and mixing mechanically until it is homogenous and applying the same as one rich coat of reinforcement complete with all dead and lift etc. complete and as directed by the Engineer in charge. (All labour, materials, tools and plants are to be supplied by the contractor only at his own cost).
Repair to slab & beam using structural grade repair mortar. After surface preparation the substrate should be thoroughly soaked with water ( any excess being removed ) prior to applying one coat of Nitobond SBR in FOSROC or equivalent in BOSTIK/ DR FIXIT and scrubbing it well into the surface. FOSROC Renderoc Plug/ BOSTIK C902 Power Plug/ DR FIXIT INSTANT LEAK PLUG can be applied as soon as the Nitobond AR in FOSROC or equivalent in BOSTIK/ DR FIXITbecome tacky. Place about 2.75 litres of drinking quality water in the mixer and, add the supplied liquid polymer part and mix with the machine in operation, add FOSROC Renderoc Plug/ BOSTIK C902 Power Plug/ DR FIXIT INSTANT LEAK PLUG powder and mix for 2 to 3 minutes Apply the mixed FOSROC Renderoc Plug/ BOSTIK C902 Power Plug/ DR FIXIT INSTANT LEAK PLUG to the prepared substrate with a gloved hand or trowel. First work a mini layer of the mortar on to the layer. Thoroughly compact the mortar on to primed substrate. Where thicker sections are required, the surface of the intermediate layer should be scratch keyed and primed with Nitobond AR in FOSROC or equivalent in BOSTIK/ DR FIXIT. Repriming with Nitobond AR in FOSROC or equivalent in BOSTIK/ DR FIXIT and further application of FOSROC Renderoc Plug/ BOSTIK C902 Power Plug/ DR FIXIT INSTANT LEAK PLUG may proceed as soon as this layer has set.FOSROC Renderoc Plug/ BOSTIK C902 Power Plug/ DR FIXIT INSTANT LEAK PLUG is finished by striking off with a straight edge and closing with a steel float. Applying one coat of acrylic curing membrane NITOBOND AR in FOSROC or equivalent in BOSTIK/ DR FIXITmixed with water in the ratio 1:1 with all lead and lift etc., complete as per manufacturer's instructions and as directed by the Engineer in charge. (All labour, materials, tools are to be supplied by the contractor only at his own cost). Avg. Thickness 30mm.
Note: For item No:18 to 21 Providing erecting, steel tubular scaffoldings using vertical props horizontal ties and diagonal bracing and the necessary members as required. The scaffolding should be retained till the work is completed in all respects including curing etc. After completion of the work, the scaffolding should be dismantled and removed out of the premises. Approx height will be 9 mtrs. (All labour, materials, tools and plants scaffolding arrangements are to be supplied by the contractor only at his own cost).
S&F in repair Aluminium sheet 1.5mm thick, 30cm width fixed with Rawl plugs and screw @ 600mm c/c with slotted hole on the both side complete all as specified and directed.
S&F 25mm thick pre formed bituminous filler pad for expansion joints filled with bitumen on top edges of 25mm thick of complete all as specified and as directed.
Dismantling boarding any description fixed in any position with nails /scrwes etc complete all as specified and as directed.
Providing and fixing decorative type gypsum board 12mm thick in ceiling fixed with screw as per manufacture's instructions and S&F powder coated Galvanized iron (GI) snap grid with interlocking frame work for false ceiling size of grid 605 x 605 mm with S&F 6mm dia Galvanized iron adjusting rod upto 1200mm length fixed to RCC roof slabs by means of ceiling cleats/dash fastners with Galvanized iron flat 40 x 3mm size 60mm long ad expansion hold fasteners 12.5mm dia 40mm long complete all as specified and directed by the Engineer in charge.
M&L Cement concrete 1:3:6 typeC-1,(using 20 mm graded stone aggregate) 75mm thick as plinth protection complete all as specified and directed.
Forming contraction (Dummy) joints 20mm deep x 10mm wide filled with sealing compound Grade Á complete all as specified and directed.
Taking down cement plaster on brick walls including racking out joints, hacking for key scrubbing down with water etc.complete all as specified and directed.
M&L for Rendering 15mm thick in fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth with out using extra cement but using water proofing compound complete all as specified and directed.
M&L for Rendering 10mm thick in fair faces of brick work or concrete surfaces in CM 1:6 finished even and smooth with out using extra cement complete all as specified and directed.
M&L for Rendering 5mm thick cement plaster on ceiling surfaces in cement mortar 1:3 finished fair and even without using extra cement complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for RCC chajja, slab, wall, beam, column etc., complete all as specified and directed
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified directed
M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
All as per item No 32 above but 5mm and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed
M&L for R.C.C M30 Design Mix cocncrete in Chajjas,slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed
M&L Brick work with sub class 'B' brickes straight or curved on plan exc 6m radius in plain built in CM 1:6 complete all as specified and directed
Use and waste of form work to RCC bands, beams,chajjas,slabs,landing etc., on rough finished surfaces of concrete complete all as specified and directed.
M&L for RCC M30 desing mix concrete in beams,cantilevers,lintels complete all as specified and directed
Dismantling mild steel work for any description not otherwise provided complete all as specified and directed.
Taking down chowkhats or frames with shutters of size exe 1.5sqm & not exe 4 sqm each without taking off shutters from the frame complete all as specified and directed
Taking down chowkhats or frames with shutters of size not exe 1.5 sqm each without taking off shutters from the frame complete all as specified and directed
Refixing in same opening of chowkhats or frames with shutters of size exe 1.5 sqm but n.exc 4.00 Sqm each without taking off shutters from the frame complete all as specified and directed
Taking down door shutters of size exe 1.00sqm & not exe 2.00 sqm each from the frame complete all as specified and directed
P&F powder coated aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections Powder coated aluminium (minimum thickness of powder coating 50 micron) and other sections of approved make conforming to IS: 733 and IS: 1285, fixing frames with dash fasteners of required dia and size,including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, complete all as specified and directed as per the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
S&F powder coated aluminium glazing/doors & shutters made out of aluminium section shutters made of size 100x45x1.5mm for side rails & top rails with Middle/ lock rail & bottom rails of size 200x45x1.5mm to made bottom rail 200mm height and including rubber gasket & aluminium beeds 20mm size ( fixed or openable type ) including required Nos of pivots, brass mortice lock, 3 No's of 150mm long powder coated aluminium hinges snap with beading screws, packing handles 2 Nos in each door and three Nos of keys complete all as specified and directed by Engr-in-Charge.
S&F Factory made UPVC white colour sliding window three track made of extruded profiles with wall thickness of 2.3mm (1-0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52 mm), sliding sash (42 x 67mm), sliding mesh sash (42mm x 57mm), sliding interlock (One vertical length in each shutters) 45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, incl railing of holes for fixing hardware and dreainage of water etc, making arrangement for fixing of EPDM gasket, 1.2 + 0.2 mm thick galvanized steel frame (30mm x 18mm) 2 Nos, sliding sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasterners. Hardware (Touch lock of zinc alloyed (white powder coated), steel rollers system. Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40mm and required accessories) complete all as specified and directed. Note : (a) The quoted rate shall be inclusive of all fittings and fixures. (b) The quoted rate shall not the cost of glass and steel wire mesh and includes all other connected accessories.
S&F 2nd class HW plain solid straight chowkhat and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F IInd class HW factory made glazed skeleton shutters 35mm thick open rebated and prepared to receive glass, wire gauge etc but divided into squares/rectangle with intermediate wooden skelton of plain chamfered or rounded mitered and rebated cash burns any numbers without interlocking rail complete all as specified and directed by the Engineer in charge.
S&F factory made plain framed panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated 08021 Ditto, without interlocking rail and with one panel only complete all as specified and directed by the Engineer in charge.
M&L PCC 1:2:4 type B1(using 20mm graded stone aggregate) as in bed blocks or similar item etc complete all as specified and directed.
S&F Fe 290Gde -E-165 for hold fast to fix the chawkat complete all as specified and directed.
M&L Solid PVC frame (Single rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffener and fixed with 100 x 8 sheet CSK screws complete all as specified and dirceted. Note: Door frame shall be water Proof, termite Proof, elegant and should have excellent screws holding strength to fix hinges and hold door properly for long life complete all as specified and directed
S&F Factory made solid PVC Moulded Door shutter 28 to 30mm thick (styled) with 2,4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face with particle board core complete all as specified and directed
S&F 200mm aluminium powder coated barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F 300mm long aluminium sliding door bolt with hasp staple (Bolt type) and fixing clips of sheet cast or extruded section and fixing both and sliding boths of external section or cast alumnium aloy and flexed complete all as specified and directed
S&F Powder coated aluminium butt hinges 150 mm medium weight cold rolled and fixed complete all as specified and directed
S&F stainless steel cast type butt hinges of size 150mm long and fixed complete all as specified and directed
S&F in repair hydraulic door closer universal type suitable for door shutters, Aluminium (extruded section) body of 851 to 1000mm in width and of weight between 61 to 80 Kg complete all as specified and directed
M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F Venetian blinds of approved make vertical type using 100mm wide fabric blinds of approved colour/ shade and pattern including operating arrangement such as chord/ thread, counter weight, connecting chain etc and necessary fittings complete all as specified and directed. The specification and design to be as directed by engineer-in-charge.
S & F Stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with Stainless steel wire staples complete all as specified and directed.
S&F Sheet glass colured 4mm thick tinted glazing with oil putty in each pane complete all as specified and directed.
S&F Sheet glass coloured 5.5mm thick tinted glazing with oil putty in each pane complete all as specified and directed.
S&F Figured glass coloured pin headed type 4mm thick fixed to aluminium louvers in strips width not exceeding 80mm complete all as specified and directed.
M&L Wired glass Rough cast wired glass coloured, 6.4mm thick and fixed to steel/aluminium section incl rubber gasket/oil putty complete all as specified and directed.
S&F Pre laminated particle board exterior grade 12mm thick fixed with screws complete all as specified and directed.
Providing and fixing of position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, with operating steel roller covered with L-angle 50x50x5mm on both side edges all over of complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer complete all as specified and directed.
S&F Alumnium powder coated louvers (movable arrangement in pair) for ventilators including locking arrangement complete all as specified and directed
S & F Framed work such as grills, gratings,frames etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Demolition of cement concrete in roof surface including removal of old tarfelt,plastering, concrete mugs,including roughning of old concrete surfaces etc., up to the original RCC roof level complete all as specified and directed.
M&L for PCC 1:2:4 Type B0 using 12.5 mm graded aggregate as in roof as levelling course, kerbs or mud stops, rounded or chamfered on edges with water proofing compound @ 2% of cement weight complete and including finishing top surface of concrete even and smooth with using extra cement or cement mortar to receive prime coat all as specified and directed. (WPC will be measured and paid seperately)
Material and labour for roof treatment as follows:- (a) Material and labour to chipout the existing loose bitumen membrane completely to reachup to the mother slab, clean the surface throughly to make it smooth and clean of any foreign materials, repair the concrete where ever damaged using PMM HS repair, repairing of constructions/cracks/ chasing with machine and fill the same with Polymerised Motor in HS repair, coping of 75 X 75mm should be made at the junction of wall and raft slab using polymerised Cement mortar 1:4 add mixed with advance latex plus. (b) Applying one coat of 50% diluted self priming PU roof coat. Allow to dry priming coat for 4 to 6 hrs before applying PU coats and surface to be cleaned before applying PU coats. (c) Applying two coats of single component cold applied ,water based poly urethane modified acrylic dispersion with highly elastic and UV resistant water proofing treatment to the roof with HS PU roof coat of Berger or equivalent at 0.6Kg/ sqm for each coat without dilusion confirming to ASTM D 6083 -97a (Standard specification for liquid applied acrylic coating used in roofing ) each coat should allow to dry 4 to 6 hrs the components shall have a density of 1.5 to 1.3 Kg/ltrs ,having tensile strength of 1.5 N/mm2, having elongation of 350% with solid content not less 60% in two coats. SRI value should be more than 100. The coated rate shall include surface preparation, repair the cracks in mother slab by chasing with cutting machine and filled the same with polymerised motor in CM 1:4 admixed with latex agent of reputed manufacturers, making coving at junction, bore packing, treatment of construction joints completely as per manufacturers specification and complete all as specified and as directed Note: The above treatment shall be got carried out by the authorised applicator of the manufacturer approved by the Engineer -in -Charge
Supply only integral water proofing compound complete all as specified and directed.
S&F in repair vitreous china squatting pan orissa pattern size 580x440mm white with integral foot rests,squatting pan including connecting to trap and to flushing pipe anti syphonage pipe etc. Complete including making good to floor including trap set including complete concrete. flush pipe to squatt pattern closet including all joints and making good to the floor including supply and fixing of low level flushing cistern PVC of syphon system, handle,float valve,handle including brackets etc, complete all as specied and directed.
S&F in repairs vitreous china washdown water closet (pedestal pattern ) white including connecting to trap and to flushing pipe anti syphonage pipe etc. Complete including making good to supply and fixing of water closet seat cover closed pattern with flat bottom with mild steel chromium plated or aluminised hinging device and fix to floor including trap set including complete by concrete. flush pipe to closet including all joints and making good to the wall including supply and fixing of low level flushing cistern PVC of syphon system, handle,float valve,handle including brackets etc,complete all as specified and directed.
M&L in repairs vitreous china wash hand basin oval shape white/coloured flat back size 630 x 450 mm mounted on granite top 20mm thick with R.C.C Slab including 32mm dia waste coupling, waste fitting, brass, chromium plated for glazed ware WHB with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed plug, procelain stopper brackets , waste pipe etc. (granite & RCC slab will be measured and paid separately under relevant items) complete all as specified and directed.
S&F low density 32mm polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to wall complete all as specified and directed.
M&L in repairs vitreous china urinal full stall type complete including providing and fixing plugs, bedding urinal against wall in CM (1:2) securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, flush pipe with grating union for discharge pipe (Exclusive of fixing supply pipe to flushing cistern trap and waste pipe) complete all as specified and directed.
S&F G.I. flush pipe and C.P. brass urinal spreader including C.P. connecting pipe Range of two lipped urinals complete all as specified and directed.
S&F vitreous china urinal partition white size 310mm x 770mm, complete all as specified and directed by Engr-in-charge.
S&F in repairs Pillar taps swan neck 15mm dia, cast copper alloy with capstan heads,chromium platted screwed down high pressure with or without lettered HOT or cold with long screwed snates and fly nuts, Screwed for iron pipe and fixed(Fancy type) complete all as specified and directed.
M&L in repair 15 mm dia Bib cock fancy type cp screwed down screwed for iron pipe or for brass ferrule and fixed 15mm bore dia all as specified and directed.
S&F in repair Stop valves, fancy type, CP with long shank and cup ( concealed typee ), screwed both ends for 15mm bore of iron pipe or for union and fixed complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and as directed
S&F in repair low density 40mm polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to wall complete all as specified and directed
S&F in repair stainless steel Tubular towel rail 20mm dia D type 60cm long between flanges brass chromium plated complete all as specified and directed
M&L in repair Soap shelf, PVC white/colour appx size 450 x 125 x 40mm (as per sample). Make: Prayag or equivalent complete all as specified and directed
S&F in repair Health faucet chromium plated including 1.25 metre long CP flexible pipe, with wall hook making connection and fixed in position Screwed for iron pipe and fixed for 15mm bore dia (Fancy type)m complete all as specified and directed
Demolition of lime cement concrete in sunken floors upto the original RCC roof level/ desire depth complete all as specified and directed
M&L for laying of cement concrete type C-1, 1:3:6 of 20 mm graded with stone aggregate in sunken floors etc complete all as specified and directed by Engr-in-Charge.
M&L for applying two coat of polymer modified cementitious water prooofing coating as per manufacturer's instruction to bottom and vertical sides upto finished floor level +100mm height thickness of each layer shall be 1mm. When second layer is sticky, coarse sand spray shall be carried for the vertical and bottom surface including all waste pipe and junction shall be sealed with epoxy putty complete all as specified and directed.MAKE: FOSROC/ BOSTIK/ DR. FIXIT
Taking down PVC SWR/drain pipe of any size and length complete all as specified and directed.
S&F in repair PVC SWR pipe single socketed in any length with rubber ring joints fixed to wall/flooring 110mm dia for soil waste/rain water pipe complete all as specified and directed.
S&F in repair PVC SWR pipe single socketed in any length with rubber ring joints fixed to wall/flooring 75mm dia for soil waste/rain water pipe complete all as specified and directed.
S&F 110mm PVC SWR bends of any radius complete all as specified and directed.
S&F 110mm PVC SWR bends of any radius with access to door complete all as specified and directed.
S&F 110mm PVC SWR junction single,(Single T) equal or unequal with access to door complete all as specified and directed.
S&F 110mm PVC SWR vent cowl complete all as specified and directed.
S&F 75mm PVC SWR bends of any radius complete all as specified and direceted.
S&F 75mm PVC SWR bends of any radius with access to door complete all as specified and directed.
S&F 75mm PVC SWR junction single,(Single T) equal or unequal with access to door complete all as specified and directed.
S&F 75mm PVC SWR vent cowl complete all as specified and directed.
M&L for PVC (SWR) Floor trap 75 mm dia ,including 40mm dia HDPE pipe up to the trap of bath room and jointing with solvent with outlet pipes, stainless steel grating etc fixed complete all as specified and directed.
M&L PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement with outlet pipes and PCC 1:2:4 filling around trap and 25mm thick coverslab (size as directed by EIC) complete all as specified and directed.
S&F in repair rotation moulded polythene water storage tank made of three layers (cylindrical vertical with closed top) hoisted all as specified on SSR Part I of 1000 Ltrs capacity with and including 20mm brass ball valves, high pressure, with polyethylene float valve and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
M&L in repair Stainles steel kitchen sink 1mm thick with drainage board of over all size 915x460mm and bowl size of410x330x160mm mounted on granite top 20mm thick including CP brass 32 mm dia waste coupling, waste fittings,plug, procelain stopper brackets etc.(granite will be measured and paid separately) complete all as specified and directed.
Taking up or down steel tubing and connections 15mm dia complete all as specified and directed.
-do- but 20mm dia complete all as specified and directed.
S&F in repair high density PVC pipe HDPE 15mm dia with all fittings/fixtures and fixed complete to walls concealed and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge
S&F in repair high density PVC pipe HDPE 20mm dia with all fittings/fixtures and fixed complete to walls concealed and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 15mm bore pipe complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 20mm bore pipe complete all as specified and directed.
Dismantling structural steel work complete all as specified and directed
Dismantling of plain or corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed
S&F Roof trusses (framed) trussed,purlins, crane gantries,rails and fastenings and heavy braket framing (Beams,tee,angle,chanel, hollow mild steel sections or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F in repair prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed
Cutting grooves in brick wall 75mm wide and 65mm deep and shaping the horizontal surface of groove with cement mortar 1:3 complete all as specified directed
Dismantling carefully MS or wrought iron work as in rolling shutters or of any description and in any position not otherwise specifically provided complete all as specified and directed
S&F in repair 1.25 mm thick Steel rolling shutters with ball bearing as specified including top cover 1.25 mm thick of required length and width, anchoring rod, high tension rolling spring, covered with MS steel frames of desired length, hasp and staple in connecting with all accessories with lever locks. keys and one shop coat of primer erected in position as indicated, with motor operated type complete all as specified and directed.
M&L for preparation of old plasterd surfaces of wall and applying two coats of all weather proof exterior paint of required shade (Company Depot Tinted) with high durability and performance with elastomeric properties having VOC not less than 50 gm/litre and UV resistance as per IS:15489:2004, Alkali and fungal resistance, dirt resistance with silicon additives @ 1.43 litre/ 10 sqm complete all as specified and directed by Engineer-in-charge. The colour and shade of the paint to be as approved by Engineer in charge.
M&L for Preparation of old plastered surfaces of wall and applying two coat of acrylic Emulsion paint interior complete all as specified and directed Engineer-in-charge. The colour and shade of the paint to be as approved by Engineer in charge.
M&L for Complete Removal of existing treatment and applying two or more coats of acrylic Emulsion paint with one coat of primer on wall surfaces over and including 2mm thick wall care putty finish complete all as specified and directed by the Engineer in charge. The colour and shade to be as approved by Engineer in charge.
M&L for Preparation of old decorated surface and applying two coats of oil bound distemper(OBD) on ceiling complete all as specified and directed
M&L for preparation of old steel surfaces of any description of two coats of synthetic enamel paint complete all as specified and directed
M&L for preparing old wooden surface and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified directed by the Engineer in charge.
M&L for Preparation of newly plasterd surfaces of wall and applying two coats of all weather proof exterior paint with high durability and performance with elastomeric properties of having VOC less than 50 gm/litre and UV resistance as per IS 15489 : 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including one priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including 2mm thick wall care putty finish complete all as specified and directed by the Engineer in charge.
M&L for Preparation of newly plastered surfaces of wall and applying two or more coats of Acrylic emulsion paint interior over One coat of primer over including 2mm thick internal wall care putty finish complete all as specified directed by the Engineer in charge.
M&L for Preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper with one coat of primer complete all as specified and directed.
Preparation of new steel surfaces and apply two or more coats of Synthetic Enamel paint over a coat of primer complete all as specified directed by the Engineer in charge.
Preparing new plastered/concrete surfaces any description of two or more coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed
M&L for preparing new wooden surface and applying two or more coats of synthetic enamel paints over a coat of pink primer complete all as specified directed by the Engineer in charge.
M&L for repairs/treatment of contraction joints (30 to 40 mm wide and 45 to 50mm depth) and floor cracks by racking the old material, joint filling materials, grinding & cutting for removing the deposits/oil etc of old materials and repairing the joint surfaces with high strength epoxy resin mortar (Cipicrete) complete all as per manufacturer's instruction complete all as specified and directed.
Repairs to pot holes by chipping (upto 20mm depth) and cleaning surface with compressed air or other approved means to removes dust/loose particles etc and applying epoxy mortar screed admixture with silica sand complete all as per manufacturer's instruction complete all as specified and directed.
M&L for 3mm thick Epoxy medium duty flooring of any shade consisting of following :- (A) Prepration of surface by scraifying the concrete surface to remove all oil, grease, paint or any other foreign particles and ensure complete adhesion of the coating to base floor using floor griding with vaccumiser. the concrete surface shall have a rough clean, dust free before application of high compressive strength epoxy flooring complete all as specified and directed. (B) Providing and applying two component primer CIPOXY 11 (100 microns) of CIPY or equivalent of FOSROC/BASF on the prepared surface by brush/Roller covered and sealed evenly on entire surface and allow for 4-5 hours curing. Applying two components CIPOXY-90 (in combination with graded aggregates, offers the highest compressive strength, greater than 100 MPa among the epoxy screed) of CIPY or equivalent of FOSROC/BASF mortar in the ratio 2:1 and mixed with 2.5 parts of Silca Quartz in a powder mixture/as per manufacturer's instructions to achieve homogeneus and applied & levelled by trowelling to form a monolithic layer to a thickness of 1900microns and alow curing for 4-5 hours complete all as specified and directed (C) Self leveling EPU top coat with CIPOTHANE SL 1000 of CIPY or equivalent of FOSROC/BASF at a specified ratio and levelled by trowelling to a thickness of 1000 micron and spike roller is applied for de-aeration. The entire top coat has to be dried for 24 hours before loading complete all as specified and directed.
M&L for Yellow or White (Aisle) band 75mm marking with 2 component Poyurethane resin + hardner with fluorescent (FK-666) on applied EPU flooring complete all as specified and directed.
Demolition of brick work or stone masonry build in cement mortar complete all as specified and as directed by the Engineer-in-Charge.
Hacking out old broken glass any thickness complete all as specified and as directed by the Engineer-in-Charge.
Taking down carefully point wiring with aluminium conductor from surface conduit/concealed conduit for light fan socket, power socket etc complete removing the material from site and making good disturbed surfaces of walls, floors, ceilings etc all as directed.
M&L for Point wiring with PVC insulated, FRLS PVC unsheathed, two single core, stranded, copper conductor cable 1.5 Sqmm size, 1100V grade, drawn into and including concealed rigid non-metallic PVC conduit not less then 20mm dia, ISI marked with 1.5 Sqmm unsheathed, stranded copper FRLS cable for continuous earth wire and including pressed modular metal concealed terminal boxes of reqd size and suitable size inner frame with outer cover suitable for modular switches/sockets/regulators all as specified & directed for the folowing :-
(a) One light/Fan controlled by one switch
(b) One point for socket outlet 5 amp independent board
(c) One point for socket outlet 5 amp same board
(d) One bell/buzzer point controlled by one push button on the same board with other switches or independent.
(e) One 3/5 pin 15 amp socket outlet point controlled by one switch using 2.5sqmm sqmm copper conductor FRLS cable with continuous earth wire of 2.5sqmm copper conductor FRLS cable on independent board
(f) One light point controlled by two 2 ways switches with cables 1.5 sq mm
(g) All as per item No 2 here in before but for PVC insulated FRLS copper conductor of size 4.0 sqmm for switch socket multipurpose AC metal clad point including provision of 4Sqmm PVC insulated FRLS copper conductor cable as earth continuity conductor on independent board
M&L for Point wiring with PVC insulated, FRLS PVC unsheathed, two single core, stranded, copper conductor cable 1.5 Sqmm size, 1100V grade, drawn into and including concealed stove enamelled steel conduit not less then 20mm dia, ISI marked with 1.5 Sqmm unsheathed, stranded copper FRLS cable for continuous earth wire and including pressed modular metal concealed terminal boxes of reqd size and suitable size inner frame with outer cover suitable for modular switches/sockets/regulators all as specified & directed for the folowing :-
(a) One light/Fan controlled by one switch
(b) One point for socket outlet 5 amp independent board
(c) One point for socket outlet 5 amp same board
(d) One 3 pin 15 amp socket outlet point controlled by one switch using 4.0sqmm sqmm copper conductor FRLS cable with continuous earth wire of 2.5sqmm copper conductor FRLS cable on independent board
S&F modular switch , 6 amps, 230V AC,single pole, one way complete all as specified and as directed
S&F modular switch 16 amps, 230V AC single pole one way complete all as specified and as directed
S&F modular socket out let multipurpose suitable for 2/3 pin 6 amp flush type complete all as specified and as directed
S&F modular socket out let 2 in 1, 3/6 pin 6 and 16 amp flush type complete all as specified and as directed
S&F Modular fan step regulator, 120 W-2 module complete all as specified and as directed
S&F ceiling rose, surface type, bakelite 65x50mm three terminal complete all as specified and as directed
S&F bell push,modular,5Amp,230 V complete all as specified and as directed
S&F electronic call bell multi music type, AC 230volts single phase. complete all as specified and as directed
Supply and fixing LED lights fitting 1x 22 W, 230V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 230V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure diecast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed
S & F LED light fitting 1x9W/1X10W bulkhead luminaires, 230V including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
Taking down carefully MCB DBs/MCCB DBs with MCBs/MCCBs of any type any size complete all as specified and as directed
S&F (in replacement) Sheet metal enclosure powder coated double door in flush fixed position suitable for MCB DB TPN 6way 415 volts, 50 HZ with 200 Amps rated copper bus bar complete all as specified and as directed
All as per item No 154 above but 12 way, TPN, 415 Volts, 50HZ complete all as specified and as directed
Supply and fixing 63 Amp TPN 415V 10KA 'C' curve miniature circuit breaker (MCB) of and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed
Supply and fixing 100 Amp TPN 415V 10KA 'C' curve miniature circuit breaker (MCB) of and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and as directed
Supply and fixing 40 Amp TPN 415V 10KA 'C' curve miniature circuit breaker (MCB) of and current carrying capacity in the DB complete with connection testing and commissioning
Supply and fixing 6 to 32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning.complete all as specified and as directed
Supply and fix (in replacement) sheet metal enclosure with socket plug top, single phase and neutral enclosure with two pin and earth plug complete with one single pole 25 Amps MCB for AC's all as specified and directed.
Supply and fix (in replacement) sheet metal enclosure with socket plug top, triple pole and neutral enclosure with 3 pin and earth plug complete with three pole 32 Amps MCB for indusrtrial socket all as specified and directed.
Taking down the sub main wiring of any size from the wall / roof / ceiling and removing from the site and making good disturbed surface complete all as specified and as directed
M&L for submain wiring complete with 4 x 10 Sqmm + 1 x 10.0 Sqmm earth wire PVC insulated and unsheathed FRLS cable with multistranded copper conductor in suitable size PVC conduit (ISI marked) on surface complete all as specified and as directed. ( for Main DB to Sub DBs and AC DBs to indl AC metal clad sockets) . Note : 4 Runs of PVC copper cable of size 10 sqmm and 1 Run of 10 sqmm PVC copper cable and 1 Run of PVC conduit will be measured as one run.
M&L for submain wiring complete with 4 x 10 Sqmm + 1 x 10.0 Sqmm earth wire PVC insulated and unsheathed FRLS cable with multistranded copper conductor in suitable size steel conduit (ISI marked) on surface complete all as specified and as directed. ( for Main DB to Sub DBs and AC DBs to indl AC metal clad sockets) . Note : 4 Runs of PVC copper cable of size 10 sqmm and 1 Run of 10 sqmm PVC copper cable and 1 Run of steel conduit will be measured as one run.
M&L for submain wiring complete with 4 x 16 Sqmm + 1 x 16.0 Sqmm earth wire PVC insulated and unsheathed FRLS cable with multistranded copper conductor in suitable size PVC conduit (ISI marked) on surface complete all as specified and as directed. ( for Main DB to Sub DBs and AC DBs to indl AC metal clad sockets) . Note : 4 Runs of PVC copper cable of size 16 sqmm and 1 Run of 16 sqmm PVC copper cable and 1 Run of PVC conduit will be measured as one run.
M&L for submain wiring complete with 4 x 16 Sqmm + 1 x 16.0 Sqmm earth wire PVC insulated and unsheathed FRLS cable with multistranded copper conductor in suitable size Steel conduit (ISI marked) on surface complete all as specified and as directed. ( for Main DB to Sub DBs and AC DBs to indl AC metal clad sockets) . Note : 4 Runs of PVC copper cable of size 16 sqmm and 1 Run of 16 sqmm PVC copper cable and 1 Run of Steel conduit will be measured as one run.
M & L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx 6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion, complete all as specified and as directed by the Engineer-in-Charge. The unit rate shall include earthwork, PCC1:3:6 TYPE C1 chamber RCC 1:2:4 type B1 cover 50 mm thick , TMT bars @ 150 mm c/c both ways, funnel and watering pipe 20 mm dia medium grade, GI protection pipe light grade 15 mm dia and workmesh, test point, charcoal dust breeze etc all as specified and directed.
S&F earth continuity conductor 4mm dia or main earthing lead fixed to wall on battern or chases or burried in ground or drawn in conduit etc.complete all as specified and as directed
S&F in replacement of perforated cable tray w/o cover made out of GI sheet 300 mm width, 150 mm depth, 2 mm thick, anodised painted and hanging on ceiling with down roads/fixing on walls with slotted angle channel 40x40x2mm size for supporting the cable trays inclusive of vertical elbows, tees, cross reducers etc for passing the electric power cables under the ceiling incl required opening on the walls with finish and angle iron support complete all as specified and as directed
M&L for submain wiring for high bay luminairs from LED lamp light fitting of 10 Mtr height roof to control DB complete with 2 x 2.5 Sqmm + 1 x 2.5Sqmm earth wire of FRLS grade PVC insulated and unsheathed FRLS cable with multistranded copper conductor in suitable size steel conduit (ISI marked) on surface and all accessories like bend, tees, junction box incl taking down the old wiring etc complete all as specified and as directed Note: 2 Runs of 2.5 Sqmm and 1 run of 2.5 sqmm copper cable with 1 Run of steel conduit will be measured as one run.
S&F in repair of RCCBs for earth leakage protection 4P, 100mA, 63A complete all as specified and as directed
S&F in repair of RCCBs for earth leakage protection 4P, 100mA, 40A complete all as specified and as directed
S&F in repair of RCBOs for earth leakage, over load& short circuit protection 4P, 100mA, 63A complete all as specified and as directed
S&F in repair of RCBOs for earth leakage, over load& short circuit protection 4P, 100mA,40A complete all as specified and as directed
Supply and fixing in repair energy efficient highbay light fitting of 120 Watt including No of LEDs in fittings as per manufacturer's instructions for lighting of 120 watt,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficiency more than 100 lumens/watt individual LED's should have lenses for better throw across and along road, PF not less than 0.9 with voltage range 140 to 270 volt fitting should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fitting including making electrical connection for cable connection complete all as specified and directed.
M&L for DOL starter suitable 415V, 1-5A rating including taking down complete all as specified and directed.(For Exhaust fan HD 415V)
M&L for disconnecing taking down and stacking the unserviceable /broken earth wire /strip of any size from the roof or from wall and removing the same from the site complete all as specified and as directed
S&F Air termination single pointed aluminium rod 12 mm dia and 300 mm long with and including provision of 40 mm dia light grade GI pipe 1.2 m long drilled and fixed to roof / wall on epoxy based insulated post including necessary fixing arrangements GI nuts, bolts, washers, MS clamps etc complete all as specified & as directed. Note: (i) Quoted rate is deemed to be inclusive of necessary miscellaneous items like bolts/ nuts/ washers etc and other items required at site complete all as specified and as directed (ii) GI Pipe, PCC blocks and excavation and earth work will be measured and paid separately.
S&F 40 mm dia bore, light grade GI pipe fixed to walls / poles or or embedded on PCC for Termination rod or laid in trenches, road crossings etc for protection of GI Strip including sealing ends with hessain cloth impregnated with bituminous compound in ground and with teak wood plugs for ends fixed on walls / poles complete all as specified and directed
M & L Cement concrete for PCC blocks of size 30 Cm X 30 Cm X 30 Cm in Type- B1 1:2:4 using 20 mm graded aggregate all as specified and as directed.
S&F aluminium strip 25 mm x 3.15 mm fixed on insulated FRP insulator, spacers & fixing screws for roof and down conductors upto test point terminal block complete all as specified & as directed.
Supply and fix GI strip 32 mm x 6 mm buried in ground / laid in floor / fixed to wall / fixed on insulated FRP insulator, spacers and fixing screws for down conductors upto test point etc (for additional provision beyond first 7.5 mtr and for internal connection for loop earthing, earthing grid etc complete all as specified & as directed.
S&F test Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw fixed on insulated FRP insulator & fixing with screws etc complete all as specified & as directed.
M&L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below the normal ground level) with top edge of plate not less than 1.5m below normal GL, connected to GI earth strip of size 32 mm X 6 mm thick as earth lead connected by means of bolts, nuts, washers check nuts made out of galvanized iron or steel all as shown on electrical plate No.3 of SSR Part-I connected to continuous earth lead complete all as specified directed. NOTE-1 : The unit rate shall also include for earth work in hard/dense soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm C/C both ways, funnel with watering pipe 20 mm medium grade, GI protection pipe light grade 40 mm dia and wire mesh, Test point, charcoal dust/breeze etc all specified and directed.
Supply, install, testing and commissioning of Induction motor not less than 3.00 HP, 3 phase, 50Hz, 415 volts AC, connected by means of MS coupler to suitable speed reduction gear box (worm gear box) and further connected to bevel gear box by MS coupler of suitable length including suitable forward and reverse motor starter and limit switch. The AC induction motor and worm gear box shall be fixed on Suitable MS section frame work either floor mounted or wall mounted as per site condition including provision of manual operation by handle in case of powerfailure etc including dismantling old motor carefully and depositing in MES store yard of any type complete with all accessories all as specified and directed by Engineer-in-Charge. Note: i) The electric drive / worm gear box shall be so designed / adjusted as to limit the speed of movement of the rolling shutter in either directions to not more than about 10 cm/sec. ii) The design of AC induction motor-3.00 HP and worm gear box shall be designed for lifting capacity not less than 1500 Kgs upto a height of 9.0 meters. ii) The quoted rated includes for AC induction motor-3.00 HP, speed reduction gear box (worm gear box), MS coupler (02 Nos), motor starter, provn of manual operation with handle, limit switch and necessary masonary work for placing motor and gear box as per site condition alongwith MS frame work.
S&F starter with forward/ reverse operations complete set of AC, 3 phase, 415V, 16A capacity with over load relay 2to 16 Amp complete all as specified and as directed
S&F Limit switch AC 440V, 10Amps, complete all as specified and as directed
Supply only cordless remote with all necessary control buttons to operate the motorised rolling shutter complete all as specified and as directed
Supply, install, testing and commisssioning of CPRI approved indoor type LT panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz power distribution panel of suitable size, Pre-wired with adequate size of single core PVC insulated FRLS stranded copper conductor cable, control fuses, earthing terminals, lifting hooks, Danger notice board, free standing, front and back openable construction, floor mounting, dust and vermin proof of IP-52, provision of ventilation compartmentalised design, hinged type double door with mechanical locking arrangement for each feeder, factory fabricated out of 2.0 mm thick CRCA sheet, 7 tank process powder coated painting fixed on and including MS Angle iron frame of suitable size and bottom legs made of MS channel of suitable size not less than medium channel 75 and adequate length including necessary earth work, civil work with PCC 1:3:6 type C2 foundation and comprising of the following switch gear and accessories complete all as specified and directed :-
Supply, install, testing and commisssioning of CPRI approved indoor type LT panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz power distribution panel of suitable size, Pre-wired with adequate size of single core PVC insulated FRLS stranded copper conductor cable, control fuses, earthing terminals, lifting hooks, Danger notice board, free standing, front and back openable construction, floor mounting, dust and vermin proof of IP-52, provision of ventilation compartmentalised design, hinged type double door with mechanical locking arrangement for each feeder, factory fabricated out of 2.0 mm thick CRCA sheet, 7 tank process powder coated painting fixed on and including MS Angle iron frame of suitable size and bottom legs made of MS channel of suitable size not less than medium channel 75 and adequate length including necessary earth work, civil work with PCC 1:3:6 type C2 foundation and comprising of the following switch gear and accessories complete all as specified and directed :-
Supply, install, testing and commisssioning of CPRI approved indoor type LT panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz power distribution panel of suitable size, Pre-wired with adequate size of single core PVC insulated FRLS stranded copper conductor cable, control fuses, earthing terminals, lifting hooks, Danger notice board, free standing, front and back openable construction, floor mounting, dust and vermin proof of IP-52, provision of ventilation compartmentalised design, hinged type double door with mechanical locking arrangement for each feeder, factory fabricated out of 2.0 mm thick CRCA sheet, 7 tank process powder coated painting fixed on and including MS Angle iron frame of suitable size and bottom legs made of MS channel of suitable size not less than medium channel 75 and adequate length including necessary earth work, civil work with PCC 1:3:6 type C2 foundation and comprising of the following switch gear and accessories complete all as specified and directed :-
Supply, install, testing and commisssioning of Automatic Power Factor Correction (APFC) Panel suitable for 3 Phase, 415 volts, 50Hz system of capacity 200 KVAR with suitable for 6 steps APFC relay CPRI approved of suitable size,Pre-wired with adequate size of single core PVC insulated FRLS stranded copper conductor cable, control fuses, earthing terminals, lifting hooks, Danger notice board, free standing, front and back openable construction, floor mounting, dust and vermin proof of IP-52, provision of ventilation compartmentalised design, hinged type double door with mechanical locking arrangement for each feeder, factory fabricated out of 2.0 mm thick CRCA sheet, 7 tank process powder coated painting fixed on and including MS Angle iron frame of suitable size and bottom legs made of MS channel of suitable size not less than medium channel 75 and adequate length including necessary earth work, civil work with PCC 1:3:6 type C2 foundation and comprising of the following switch gear and accessories complete all as specified and directed :-
Supply and Fix MCCB 400 Amps thermal magnetic trip type 4 Pole, 36 KA, 415 volts 50 Hz and termination with suitable spreaders, lugs, bolts and nuts including miscellaneous item required at site and testing complete all as specified and as directed.
Disconnecting/taking out the old U/S incoming and out going LT cables from the existing trenches/wall /ceiling etc inside/outside the wksp incl lifting removing the duct cover made out of MS plate of any size for replacement of the cable and placing the duct cover back in position after replacing the cable complete all as specified and as directed
Supply,laying,connecting and testing XLPE Insulated PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core. confirming to IS-7098(Part-I) laid in cable trenches /Duct /Wall /surfaces /Pipe including compression gland , lugs as required at site complete all as specified and as directed
Supply,laying,connecting and testing XLPE Insulated PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core. confirming to IS-7098(Part-I) laid in cable trenches /Duct /Wall /surfaces /Pipe including compression gland , lugs as required at site complete all as specified and as directed
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other situation for loop earthing etc.as required GI strip 25x4mm size complete all as specified and as directed
M&L for steel water tubing light grade galvanised with all fittings for cross the earthing strip in wall/floor/ trench of size 50mm bore complete all as specified and as directed
Excavation in trenches not exceeding 1.5 m width and not exc 1.5 m in depth and getting out soil for removing/laying of UG cables / Pipes etc complete all as specified and as directed
Returning, filling including spreading levelling watering and well ramming in layers not exc 25 Cm thickness using excavated Soil complete all as specified and as directed
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point for soil complete all as specified and as directed
Material and Labour for sand cushioning to the full width of trenches for protection of cables including punning down complete all as specified and as directed. Note: Thickness of sand cushioning shall be the thickness after punning down.complete all as specified and as directed
Supply and fixing burnt bricks sub class B designation 75 old size for protection of cable all as specified and directed
P S G CONSTRUCTIONS
K. VENKATESH NAIDU
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .