| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.6 LAccepted-Finance | 1 | Accepted-Finance Bidder Quoted Lower than Estimate Value | |
| 2 | 2₹32.1 L+₹1.5 L (5.00%)Rejected-Finance | 2 | Rejected-Finance Bidder Quoted More than Estimate Value | |
| 3 | 3₹32.7 L+₹2.1 L (6.96%)Rejected-Finance | 3 | Rejected-Finance Bidder Quoted More than Estimate Value | |
| 4 | 4₹33.0 L+₹2.4 L (7.93%)Rejected-Finance 422 PALLADAM ROAD TIRUPPUR 641 604 | TIRUPPUR | TAMIL NADU | 641604 | 4 | Rejected-Finance Bidder Quoted More than Estimate Value |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
4 Oct 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commissioner
Tiruppur City Municipal Corporation
Construction of Two Class Room in First Floor with Staircase at Periyar Colony Corporation Middle School in ward No.14.
2024_MAWS_489662_6
E1/5353/2004
Open Tender
Civil Works - Buildings
Works
90 days
Tiruppur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹80,000
15 Nov 2024
29 Sept 2024
4 Oct 2024
29 Sept 2024
4 Oct 2024
29 Sept 2024
Amount
Earthwork excavation for foundation in all soils and sub soils except in hard rock requiring blasting and depositing on bank with initial lead of 10m and initial lift of 2m inclusive of shoring, shuttering, bailing out water wherever necessary, refilling the foundation with excavated earth other than sandy soil in layers of not more than 150mm thick layers well rammed and depositing the surplus earth within the compound in place shown by the departmental officers and clearing and levelling the site etc,. complete.
Supplying and filling Well gravel in layers of not more than 15cm thick well rammed, watered and compacted etc., complete complying with standard specification.
Plain Cement concrete 1:4:8 [one cement, four M-sand and eight course aggregates] using 40mm size Hard Broken/Machine crushed Granite Stone Jelly including dewatering if found necessary and laid in layers of not more than 15cm thick and compacted etc., complete complying with standard specification.
Supplying and erecting centering including necessary supports for the plane surfaces such as RCC Column Footing, Plinth Beam, & Sill Beam etc., using mild steel sheets of size 90cm x 60cm and BG 10 stiffened with welded mild steel angles of size 25mm x 25mm x 3mm for boarding supported by casurina props of 10cm to 13cm dia spaced at suitable intervals etc., complete complying with standard specification.
Supplying and erecting centering for soffits of Square / Rectangular Columns including strutting 3m high using mild steel sheets of size 90cm x 60cm and BG 10 stiffened with M.S angles of size 25mm x 25mm x 3mm laid over silver Oak (C.W) joists of size 10cm x 6.5cm (spaced at about 90cm c/c) and supported by casurina props of 10cm to 13cm dia (spaced of 75cm c/c) etc., complete complying with standard specification.
Supplying and erecting centering for soffits of plane surfaces like RCC Slabs, Lintels, Sunshades, Square Columns, Staircase waists, Beams etc., including strutting 3m high using mild steel sheets of size 90cm x 60cm and BG 10 stiffened with M.S angles of size 25mm x 25mm x 3mm laid over silver Oak (C.W) joists of size 10cm x 6.5cm (spaced at about 90cm c/c) and supported by casurina props of 10cm to 13cm dia (spaced of 75cm c/c) etc., complete complying with standard specification.
Reinforced cement concrete 1:1½:3 [one cement, one and half M-Sand and three course aggregates] using 20mm size Hard Broken/Machine crushed Granite Stone Jelly for all RCC items of works excluding centering, shuttering and cost of reinforcement, including curing, fixing fan clamp and fixtures if necessary etc., complete complying with standard specification.
For Foundation and Basement
For Super structure in Ground Floor
For Super structure in First Floor
Supplying, fabricating and placing in position of Steel Reinforcement using Mild Steel or Ribbed Tor steel bars for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors etc., complete complying with standard specification.
Brick work In CM 1:5 mix using best Second Class Table Moulded Chamber Burnt Bricks 9"x4½"x3" having 350 kg/cm² compressive strength and 15% or less water absorbent in the period of 24hours immersement and confirming to ISI specifications including finishing, curing etc., complete complying with standard specification.
For Super structure in Ground Floor
For Super structure in First Floor
For Super structure in Second Floor
Ceiling Plastering with cement mortar 1:3 mix (one cement three P-sand), 10mm thick in all floors for RCC slabs, Beams, Sunshades including packing, providing cement mortar beading for sunshades, staircase steps, landing slabs etc., as directed by the departmental officers etc., complete complying with standard specifications.
Plastering with cement mortar 1:5 mix (one cement five P-sand), 12mm thick in all floors using clean screened M-Sand and including cost of curing for fifteen days from the completion of the work and surface should free from undulations and including the cost of preparing the surface for plastering and protecting from other damages till setting of mortar etc., complete complying with standard specification.
Plastering with cement mortar 1:4 mix (one cement four P-sand), 20mm thick in all floors using clean screened M-Sand and including cost of curing for fifteen days from the completion of the work and surface should free from undulations and including the cost of preparing the surface for plastering and protecting from other damages till setting of mortar etc., complete complying with standard specification.
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder, fevicol type gum, brushes, scaffolding charges etc., complete complying with standard specification.
Painting two coats with ready mixed Plastic Emulsion paint (weather proof) of approved quality and colour over a priming coat, including thorough scraping, clean removal of dirt and including necessary plaster of paris, putty wherever required etc., complete as per standard specifications.
Fabricating supplying & fixing of M.S Doors with single / two leaves with outer frame 40x40x6mm Angle, shutter frame 35x35x6mm Angle, MS sheet 20 gauge intermediate stiffener 'T' section 25x25x6mm, panel should be covered with 20 gauge M.S sheet with necessary Tower Bolt 30cm length, butt hinges, hold fast, aldrop and handle on both sides etc., complete with one coat of red oxide primer.
Manufacturing supplying and fixing in position of Steel Window with openable shutter frame made out of steel sections confirming to IS 7452/1982. The outer frames of windows made out of 'Z' section (F7D) of size 20x20x3mm confirming to IS 7452/1982. Mullions are made out of (F4B) 'T' section of size 46x25x3mm confirming to IS 7452/1982. The shutters are individual and each of them can be operated separately. Sash bars are made of 'T' section (T2) of size 25x22x3mm. 2 Nos of sturdy hinges and one number of handle cum ratch of special type are fixed for each openable shutter. Suitable opening is left for its easy operation. One number of window adjustable string with fixing bracket of sufficient length are provided for each shutter 4 No of 40x40x3mm angle fold fasts of 230mm length are welded to the frames at appropriate point. M.S square bars of 12mm size is welded to the inner face of the window at equal intervals not excluding 10cm spacing. All members are painted with one coat of red oxide of primer. The rate is inclusive of each of all materials, labour charges for fixing, one coat of primer, welding charges, transportation to the site of work, loading, unloading and all other incidental charges etc., complete.
Painting two coats for New iron work surface using best quality synthetic enamel paint etc., complete complying with standard specification.
Floor finishing with Granolithic flooring 25mm thick in cement concrete 1:2:4 [one cement, two M-Sand and four aggregates] mix using 10mm to 12mm size metal and top rubbed smooth, including cost of all materials and labour charges for mixing, laying, finishing, watering etc., complete as per standard specification.
Flooring with fully Polished 20mm thick Rajasthan Kota stone slabs with machine cut edges of size below 2'0" x 2'0" laid over base layer of cement mortar 1:3 [one cement and three M-sand] 20mm thick and applying cement slurry & pointed with white cement and colour pigments to the colour of stones and polished neatly etc., complete complying with standard specification.
Weathering Course with Brick jelly lime concrete made in Broken Brick Jelly 20mm gauge in pure slaked lime (no M-Sand to be added) laid over roof slab, the proportion of brick jelly to lime being 32 to 12.5 and well beated with wooden beaters for giving required slope and thickness etc., complete complying with standard specification.
Finishing the top of the roof slab with one course of Machine pressed tiles of size 20cm x 20cm x 2cm of approved quality laid in cement mortar 1:3 [one cement and three M-Sand] 12mm thick mixed with waterproofing compound 2% by the weight of cement used and the top pointed with same mortar etc., complete complying with standard specification.
Providing and fixing of PVC Rain water downfall pipe of 110mm dia 4kg/sq.cm with necessary teak wood clamps etc., complete complying with standard specification.
Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A FT switch with continuous earth wire connection of 1.5 sq.mm copper wire for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (for electronic regulator)
Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet cover for 5A 3 pin non inter locking wall socket with 5A flush type switch with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for concealed PVC plug point
Supply and fixing of single box type 4'36W fluorescent fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed FRLS Copper leads from terminals to the fitting
Supply and fixing of 1200mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp
Supply and fixing of horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door (metal) with 40A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like standard make)
Supply and run of 4 x 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains
Add G.S.T. @ 18%
KSS BUILDERS (BID ID -1157370)
ARS & CO (BID ID -1153542)
Raja Constructions (BID ID -1153549)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_581829.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .