Loading…
Loading…
Tender Value
₹13.8 L
EMD Value
₹14,000
Closing Date
1 Sept 2026, 12:00 pm4d left
Executive Engineer
Office of the Executive Engineer PWD Building C and M Division Erode
Special repairs to Leaky roof, damaged flooring, Doors and Windows and water supply and sanitary arrangements in Palliyuthu HSC in Arachalur at Erode District
2026_PWD_694436_1
NIT.04 2026 27 BCM DIVISION ERODE Dated 11.08.2026
Open Tender
Civil Works - Buildings
Percentage
Palliyuthu
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹14,000
17 Aug 2026
17 Aug 2026
1 Sept 2026
17 Aug 2026
1 Sept 2026
17 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling and carefully stacking the materials useful for reuse of Pressed tiles & weathering course, etc., complete as per standard specification and as directed by the deparmental officers. | 77.3 | M2 | 49.2 | ₹3,803.16 |
| 2 | Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification and as direct-ed by the departmental officers. | 2.31 | M3 | 110 | ₹254.1 |
| 3 | Cement Concrete 1:5:10 (One Cement, Five Crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification-Mixing by manual means | 0.5 | M3 | 5,517.75 | ₹2,758.88 |
| 4 | Brick work in Cement Mortar 1:6 (one cement and Six crushed stone sand) using best quality Fly ash Brick of size 230x110x75mm with class designation of 7.5 conforming to IS 13757-1993 or IS 12894-2002 for foundation and basement including Cost of Mortar Plasticizer, curing, etc., complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in chargeFor Foundation and Basement | 1 | M3 | 7,467.95 | ₹7,467.95 |
| 5 | Supplying and laying of Inter locking Paver Block Stone 63mm thick Over a base layer of crushed stone sand filling incl. Cost of materials laying and Labour charges etc., complete complying with standard specification and as directed by the departmental officers. | 71.5 | M2 | 1,432.2 | ₹1,02,402.3 |
| 6 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers Super Structure in Ground floor | 6.6 | M3 | 4,260.5 | ₹28,119.3 |
| 7 | Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 16 mm to 18mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers | 88.2 | M2 | 1,347.55 | ₹1,18,853.91 |
| 8 | Supplying ,fabricating and fixing in position of steel frame without bottom frame, of size 100X60mm rectangular section with necessary rebate 30mmX15mm, to host the shutter,using 1.25mm thick (18 guage) CRCA cold rolled frame steel plate confirming to ISI specified ensured of right butt joint riveted hold assembly with nylon insert,not be welded with special purpose hard ware.Proclaimed including phopating as per ISI with rust preventive primer ready to assemble condition for easy installation at site including dismantling,making necessary chipping and holes in RCC columns, walls with power drills to the extent required ,including providing concrete 1:2:4 inside the box curing etc... complete complying with standard specification and as directed by the
departmental officers | 36.5 | M2 | 484.05 | ₹17,667.83 |
| 9 | Supplying and fixing Medium Density Fibre board (SBG I) of exterior grade of type (Medium Desity Fibre (MDF) Board - Exterior Grade, Both sides pre-lamiated including external lipping with kiln dried soft wood 35mm thick) with thickness conforming to IS 12406 / 2003 with necessary adhesive and C.P. screws, including fixing of aldrops, tower bolts, hinges and lock strike plates, putty, fevical, varnish for T.W. lipping with thinner colouring agent etc.,The rate includes cost of materials and cost for furniture fittings such as 3 nos SS 304 Grade Parliament inges of required Size (125mm x 150mm), 1 no Alu. aldrop 250 x 16mm, 2no Alu. tower bolt of 300x12mm and 1 no Alu. tower bolt of 200x12mm, 2 Nos Alu. Handles, 1 no door stopper with rubber bush incase of Single leaf door, cost of labour charges for fixing in position etc., complete. All Aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1968 for anodic film thickness of not less than 15 microns, The rate is inclusive cost of fevical and fixing charges, transportation, loading, unloading and all other incidential charges, handling charges etc., complete complying with standard specification and as directed by the departmental officers - Single leaf. | 13.6 | M2 | 4,026.7 | ₹54,763.12 |
| 10 | Supplying and fixing door shutters for Medium Density Fibre board (SBG I) of exterior grade of type (Medium Desity Fibre (MDF) Board - Exterior Grade, Both sides pre-lamiated including external lipping with kiln dried soft wood 35mm thick) with thickness conforming to IS 12406 / 2003 with 35 x 12mm T.W. on all edges with necessary adhesive and C.P. screws, including fixing of aldrops, tower bolts, hinges and lock strike plates, putty, fevical, varnish for T.W. lipping with thinner colouring agent etc., The rate includes cost of materials and cost for furniture fittings such as 6 nos SS 304 Grade Parliament Hinges of required Size (125mm x 150mm), 1 no Alu. aldrop 250 x 16mm, 2nos Alu. tower bolt of 300x12mm and 1 no Alu. tower bolt of 200x12mm, 3 Nos Alu. Handles,2 nos door stopper with rubber bush incase of Double leaf door cost of labour charges for fixing in position etc., complete. All Aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1968 for anodic film thickness of not less than 15 microns, The rate is inclusive cost of fevical and fixing charges, transportation, loading, unloading and all other incidential charges, handling charges etc., complete complying with standard specification and as directed by the departmental officers - Double leaf. | 2.6 | M2 | 4,309.2 | ₹11,203.92 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
Tencon_Palliyuthu.pdf
Tender Documents • 2.05 MB
BOQ_834891.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].