Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹10.7 L+₹1.8 L (20.1%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance High | |
| 3 | L3₹11.6 L+₹2.7 L (30.5%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L3 | Rejected-Finance High | |
| 4 | L4₹14.1 L+₹5.3 L (59.2%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L4 | Rejected-Finance High | |
| 5 | L5₹15.1 L+₹6.2 L (70.0%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance High |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
1 Oct 2020, 6:00 pmClosed
GE Gurdaspur
Garrison Engineer, Gurdaspur (Tibri)
Rewinding and repair to internal electrification to bldgs of outstation under GE Gurdaspur.
2020_MES_376690_1
GE GSR-44/2020-21
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer, Gurdaspur (Tibri)
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gurdaspur
₹30,000
17 Nov 2020
11 Sept 2020
3 Oct 2020
11 Sept 2020
1 Oct 2020
26 Sept 2020
Amount
Taking down/out existing aluminium/copper point wiring for light, fan, bell, socket complete including all fittings such as switches, sockets,ceiling roses, regulators, light fittings etc and removing the materials from site complete all as specified and directed.
M&L point wiring with PVC insulated, unsheathed, multistranded copper conductor cable of size 1.5 Sqmm,FR through and including concealed PVC conduit with fittings and PVC insulated, unsheathed, copper conductor cable continious earth wire of size 1.5 Sqmm ,FR,connected to common earth and modular sunken boxes for mounting of accessories complete for one ligh point/ fan point/ call bell point controlled by one one way switch complete all as specified and directed. Note :- Cost of making good the disturbed surface plastering / filling putty alongwith matching with the existing colour with MES approval make of distemper is deemed to be included in the quoted rate by the contractor.
All as per Srl item No 3.00 here-in-before but in existing PVC conduit.
All as per Srl item No 3.00 here-in-before but for one 5 pin socket outlet, 5 amps on independent board.
All as per Srl item No 5.00 here-in-before but in existing PVC conduit.
All as per item Srl No 3.00 here-in-before but for one 5 pin socket outlet, 5 amps on the same board with other switches.
M&L point wiring with PVC insulated, unsheathed, multistranded copper conductor cable of size 2.5 Sqmm,FR through and including concealed PVC conduit with fittings and PVC insulated, unsheathed, copper conductor cable continious earth wire of size 2.5 Sqmm ,FR,connected to common earth and modular sunken boxes for mounting of accessories complete for one 15 Amps, 3 pin socket outlet independent point controlled by one one way switch complete all as specified and directed. Note :- Cost of making good the disturbed surface plastering / filling putty alongwith matching with the existing colour with MES approval make of distemper is deemed to be included in the quoted rate by the contractor.
All as per item Srl No 9.00 here-in-before but in existing PVC conduit.
M&L sub main wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable, FR of size 6 sqmm and one PVC insulated, unsheathed, copper conductor cable, FR, of size 6 sqmm as earth wire fixed in and including concealed non metalic PVC conduit of appropriate dia complete all as specified.(Note :- Three run of cable along with PVC conduit together shall be measured as single run)
M&L sub main wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable, FR of size 4 sqmm and one PVC insulated, unsheathed, copper conductor cable, FR, of size 4 sqmm as earth wire fixed in and including concealed non metalic PVC conduit of appropriate dia complete all as specified and directed. (Note :- Three run of cable along with PVC conduit together shall be measured as single run)
Fixing only modular switch 1 way, 1 modular 6 amps single pole complete all as specified and directed.
Fixing only modular socket, 2 module 6A multipin combined complete all as specified and directed.
Fixing only modular switch 1 way, 16 amps, 1 module complete all as specified and directed.
Fixing only modular socket , 6A / 16A - 2 / 3 pin combined, 2 module complete all as specified and directed.
Fixing only modular fan regulator 2 module electronic type 5 step and connectingcomplete all as specified and directed. Note :- Srl item No 12 to 16 will be issued under Schedule 'B' as 'free for fixing'.
S & F modular bell push flush type single pole one way ,6 Amp complete all as specified and directed.
S&F modular white cover plate with frame, 1 module complete all as specified and directed.
S&F modular white cover plate with frame, 3 module complete all as specified and directed.
S&F modular white cover plate with frame, 4 module complete all as specified and directed.
Supply and Fixing only modular white cover plate with frame, 6 module complete all as specified and directed.
Supply and Fixing only modular white cover plate with frame, 8 module complete all as specified and directed.
Supply and Fixing only modular white cover plate with frame, 12 module complete all as specified and directed.
S&F modular metal flush box, 1 module complete all as specified and directed.
S&F modular metal flush box, 3 module complete all as specified and directed.
S&F modular matel flush box,4 module complete all as specified and directed.
S&F modular metal flush box, 6 module complete all as specified and directed.
S&F modular metal flush box, 8 module complete all as specified and directed.
S&F modular metal flush box,12 module complete all as specified and directed.
S & F electric bell Ding Dong type 230V, 50Hz complete all as specified & directed
S&F in replacement surface mounting universal batten housing made of powder coated CRCA sheet fixed on and including 02 Nos PVC square blocks suitable for and upto 1 x 18/20 W LED tube rod and taking down exisitng old unserviceable fitting complete all as specified an as directed
S&F in replecement LED tube light 20W ultra bright LED polycarbonate tubelight with very high efficacy suitable for fitting into existing/ new tube light batten fitting complete all as directed Note :- The contractor will submit the LM-80 and LM-79 report from manufacturer to Engineer-in-Charge before incorporating the items in work.
S& F in replacement tube light fitting LED 20W inverter batten type fitting 4 feet long aluminium housing, charging time 10-12 hours with 4 hours backup IP20, rated volatge 230 V, 50Hz system of wattage 20W (+/- 10%), current less than 1.2 mA, power factor more than 0.95 and system lumen efficeincy of 100 lm/watt, CCT of 6500 K, CRI > 80, THD < 30%, driver efficeincy more than 85% complete all accessories prewired and connections electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor wire of size 0.75 sqmm 3 core all as required at site.
S&F lamp holder with LED retrofit lamp suitable for Lamp holder base of 9 watt complete all as specified and directed.
S&F lamp holder with LED lamp 230V, 50 Hz inverter LED 9W lumens 900 lumens charging time 8-10 hrs, back up time 4 hrs, operating temeperature 10-50 degree celcius, complete all as specified and directed.
M&L ceiling rose, surface bakelite three terminal all as specified and directed
Taking out existing old unserviceable distribution box /sheet metal enclosure off size and making good disturbed surfaces complete with same colour.
Material and labour for replacement of distribution board made out of CRCA sheet DB vertical type double door TPN 4 Way including fixing in the wall,cutting chases grouting and necessary patch work and white wash to match with the existing including making connections all as directed containing the folowings:- (a) MCCB 4 Pole 100 Amps 16 KA breaking capacity with thermal release 01 No (In coming) (b) Bus bar 200 Amp rated made out of Aluminium on insulated duly insulated wire adhesive tape RYB & black-4 Nos (c) MCB SPN 40 Amp-4 Nos,MCB SP 10-32 Amp - 08 Nos (Out going) (d) Connection from MCCB to bus bar will be made with Aluminium Strip of suitable ampacity as directed.
Supply and fixing in repair sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 8 way with 200 amps rated bus bar SPN double door complete all as specified and directed.
S& F in repair MCB single pole 6 amps to 32 amps , C series complete all as specified and directed.
All as per Item Ser No 40 above but single pole and neutral 6 to 32 amps, C series complete all as specified and directed.
Earthing Complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 3.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common saft filling in alternate layers and electrode connection by using earth lead GI wire 4mm dia ( 8 SWG) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and other end of the earth wire connected to main switch board protected by galvanised iron light grade pipe 15mm bore in wall/floor/and GI Pipe 20mm bore light grade for watering with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 and RCC pit cover including necessary excavation and earth work in any type of soil, returning slurry approved soil and disposed of surplus soil to a distance not exceeding 50 Mtr away all as shown in electrical plate No 3 of SSR 2009 ( Part-I).
S&F in repair aluminium conducter service wire of size 10 sqmm 2 core served with inner sheating of PVC sheated ub service connection suspended by insulating hangers not more than 01 meter apart including 4mm suspension wire complete all as specified and directed.
S&F in repair GI pipe bracket made out of GI pipe 32/40mm dia and welded 1.5 meter long MS clamp made out of MS flat iron of size 40x4mm thick with nuts and bolt ,washer complete including dismentling the existing GI pipe bracket and drilling of hole for nut and bolt etc complete all as specified and directed.
Supply and fixing energy saving LED INVERTER TYPE STREET LIGHT 45 WATT AND BATTERY BACK UP OF MINIMUM 2 HOURS environmental friendly, long life , exclusive innovative die-cast aluminium IP 66 security light with high power LEDs as light source , Suitable for 40 mm GI pipe , 5700K LED ,connecting up with twin core twisted flexible copper conductor cable all as directed.
S&F PVC blank plate one module suitable for fixing in switch board complete all as specified and directed.
S&F in repair sheet metal enclosure of DBs when MCBs to be used of 240 volt 12 way with 200 Amps rated bus bar SPN double door DB including :- (i) One No over voltage relese 230V AC UC> 280 volt one module for over voltage protection of make Hager Model No MZ215. (ii) One No SPN 32 Amp. (iii) MCB SP 6 Nos Note :- All items supplied in same make Hager/ Legrand/ L&T.
satpal and brothers
UNITED ENGINEERING CORPORATION
kailu construction co
M/S SHRI RAM BUILDERS
INDERJIT SINGH
J.S. Constructions
M/S VIJ CONSTRUCTION CO
D S INFRASTRUCTURE AND DEVELOPERS
BUILDEX CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .