Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹9.5 LAdmitted-Finance 6 KAMMAVAR STREET MITTANAMALLEE IAF AVADI TIRUVALLUR TAMIL NADU 600055 | THIRUVALLUR | TAMIL NADU | 600055 | -4.95% | ₹9.5 L | L1 | Admitted-Finance |
| 2 | L2₹9.9 L+₹34,072.11 (3.58%)Admitted-Finance | -1.55% | ₹9.9 L+₹34,072.11 (3.58%) | L2 | Admitted-Finance |
| 3 | L3₹10.6 L+₹1.1 L (11.2%)Admitted-Finance | +5.70% | ₹10.6 L+₹1.1 L (11.2%) | L3 | Admitted-Finance |
Tender Value
₹15.9 L
EMD Value
₹31,840
Closing Date
1 Dec 2025, 6:00 pmClosed
Executive Engineer Medical Health Div I Jaipur
Executive Engineer Medical Health Div I Jaipur
SITC of Air Conditioners and Cold Room work for IPHL Building at Jaipuria Hospital, Jaipur.
2025_MEDIC_513391_4
NIT55/2025-26EE M and HDn. I Jaipur/
Open Tender
Electrical Works
Percentage
30 days
Jaipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
RTGS/NEFTRTGS/NEFT/Any other money Transfer System
₹31,840
8 Dec 2025
15 Nov 2025
3 Dec 2025
15 Nov 2025
1 Dec 2025
15 Nov 2025
Amount
Part 'B' NON BSR ITEM
Technical Specification for Cold room
SITC of Sandwich PUF Panel for cold room wall & ceiling, insulation should be cyclopentane PUF having density 40Kg/M3 60mm thickness, fire resistance, mattelic cam /flasing lock joint with prepainted G.I sheet 0.4 mm thick inside and outside. Corner panels are to be provided for neat and clean room complete in all respect.
SITC of Floor of PUF Panel density 40 Kg/M3 with insulation of 60mm Cyclopentane PUF with 12 mm marine ply & 1.2 mm Aluminium Chequer Sheet anti skid flooring.
SITC of flush type door assembly having opening of 34"x78" with door frame, door leaf magnetic gasket, door closure, sweaper gasket, handle with lock assembly & door hinges with view port 300x300 mm & PVC strip curtain including rescue button, so that in case door is locked, door may be open from inside. (excluding cost of PUF Panel)
SITC of invertor based cooling unit consisting of condensing & evaporator unit in S.S. body with R404a refrigerent of capacity 10000 BTU/Hr. with energy efficient hermatic/scroll compressor, Temperature range should be +2 degree Cent to +8 degree Cent. Operation on 220/415 volt 50Hz AC supply, complete with refrigeration control panel accessories, first charge of refrigerant gas with stand/ wall bracket for placement of outdoor unit. Temperature controller hard refrigerant copper piping of suitable 3/8 & 5/8 sizes beteween indoor & outdoor with 19mm thick nitrile insulation, control cable etc. Standard practice U-PVC condensate drain piping size 32mm with 9mm insulation with voltage stabilizer of suitable capacity, pull down time should be 24hrs, compressor run time should be not more than 18 hr. within 24 hrs. complete in all respect.
SITC of Automatic Electrical Control Panel for switch over each unit in 4 Hr. interval complete in all respect.
GLOBAL PROJECT (BID ID -3381637)
Ritika Air Cooling and Electrical (BID ID -3384118)
GLOBAL PROJECT (BID ID -3381637)
Ritika Air Cooling and Electrical (BID ID -3384118)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.92 MB
Tendernotice_2.pdf
PDF • 7.44 MB
Tendernotice_3.pdf
PDF • 0.07 MB
Tendernotice_4.pdf
PDF • 2.57 MB
Tendernotice_5.pdf
PDF • 0.14 MB
Annexure-A_BSR_2022.pdf
Tender Documents • 0.26 MB
Special_TandC_for_Electrical_work_AnnexureC.pdf
Tender Documents • 0.35 MB
TandC_for_Electrical_work_DLP_AnnexureB.pdf
Tender Documents • 0.24 MB
BOQ_915719.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .