| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.6 LAccepted-AOC B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹41.6 L | L1 | Accepted-AOC Lowest and reasonable |
| 2 | L2₹47.2 L+₹5.6 L (13.5%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹47.2 L+₹5.6 L (13.5%) | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹49.6 L+₹7.9 L (19.0%)Rejected-Finance | ₹49.6 L+₹7.9 L (19.0%) | L3 | Rejected-Finance Other than Lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not ENLISTED Appropriate Category |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Enlisted in Appropriate Category |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
19 Jul 2024, 6:00 pmClosed
HQ CWE (AF) Jammu
Headquarters, CWE (AF) Jammu Near Gurdwara Sahib and Mandir Airforce Station Satwari, Jammu Pin 180 003
PROVN OF BATHROOM TOILETS, EXTERNAL SERVICE FOR DRAINAGE, SEWAGE AND ELECTRICAL INSTALLATION AT AF STN NATHATOP UNDER GE(AF) UDHAMPUR
2024_MES_655306_1
CWEAFJ-17/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Udhampur
All as per Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Udhampur
₹87,000
Yes
5 Oct 2024
22 May 2024
22 Jul 2024
22 May 2024
19 Jul 2024
5 Jul 2024
Amount
B/R PORTION
Excavating in trenches not exceeding 1.5m wide and n.exceeding 1.5m in depth; for any type of soil and getting out complete all as specified and directed. Note"- All excavation, RFR and removal of soil work will be done manually by Labour only.
M&L for PCC 1:4:8 type D2 (40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed .
M&L for for random rubble stone masonry walling uncoursed, well bonded and solidly hearted built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work in cement mortar 1:6 with sub class `B' bricks straight or curved on plan exceeding 6 m mean radius complete all as specified and directed.
Removing of soil to distance exc 1.5 KM and n.exc 5.00 KM depositing at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed .
M&L for for 40 mm thick Damp proofing course with PCC 1:2:4 type B-0 ( using 12.50 mm graded crushed stone aggregate ) to horizontal or vertical surface including necessary form work complete all as specified and directed.
Supply only liquid integral water proofing admixture complete all as specified and directed.
M&L for RCC M-30 Design Mix as in RCC Beams, contilevers, bressummers, lintels over 1.50 m span complete all as specified and directed.
M&L for RCC M-30 Design Mix as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and as directed .
M&L for for RCC M-30 Design Mix as in RCC Columns, pillars, piers,posts and struts complete all as specified and directed.
M&L for for RCC M-30 Design Mix Slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
All as per srl item No.1.12 above but 5 to 10 mm dia as in stirrups complete complete all as specified and directed.
M&L form work to the side of footing of column and plinth beam etc, complete all as specified and directed.
M&L for Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc, complete all as specified and directed.
M&L for Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc, complete all as specified and directed.
M&L for Form work to the side of RCC column incl finish the surface even and fair etc, complete all as specified and directed.
M&L for joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc.conferming to Fe 410-W (Gde-E- 250) quality-A etc, complete all as specified and directed.
S&F rolled mild steel roof truss ( framed ) , trussed , purlins , crane gantries , rails and fastenings and heavy bracket framing ( beam , tee , angle , channel or flat sections ) including distance pieces , cleats conforming to Fe 410-W ( Gde -E-250 ) quality-A complete all as specified and as directed .
M&L for MS rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410- (Gde-E-250) quality-A complete all as specified and as directed.
M&L for small articles such as clamp , hold fast , wall ties /wind ties , support of valley gutters , support or stays for rain water , ventilating pipes , including bolts if required etc made of MS flat iron conforming to Fe-290 W ( Gde E-165 ) complete all as specified and as directed .
S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.60 mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall , fixed with self tapping screw or L type or J type hook complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface exc 10 cm width or girth complete all as specified and directed.
M&L for applying two coats of Synthetic enamel paint over a coat of red oxide Zinc chrome primer on new steel surface n.exc 10 cm width or girth complete all as specified and as directed .
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed.
S&F 5 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane fixed with steel frame work complete all as specified and directed .
M&L for MS Framed work as in grills with ends of bars shoulders or framed guard bars and similar work conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for 5 mm rendering with CM 1:4 including WPC over 10 mm thick rendering in CM 1:6 and finish the surface fair and even complete all as specified and directed.
M&L for applying two coats of distemper oil emulsion over a coat of alkali resistant primer over 3 mm wall care putty on new wall surface complete all as specified and as directed.
M&L for glazed ceramic colour tiles (300x450x7mm) thick in skirting/dados etc, laid over 10mm thick rendering in CM (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles complete all as specified and directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed.
M&L for Non-skid ceramic coloured tiles of size 300X300X 7 to 8 mm thick (square/rectangular) as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over 15 mm thick screed bed or bedding layer in CM(1:6) and 25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded aggregate ) as in sub floor complete all as specified and directed.
M&L for 75 mm thick plain cement concrete 1:3:6 type C2 ( using 40 mm graded crushed stone aggregate ) as in plinth protection laid in alternative bays and joints shall be filled up with bituminous gola with 80/25 bitumen ( 1 part of bitumen to be mixed with 3 part of sand ) including finish the surface even and smooth complete all as specified and directed.
M&L for hardcore with broken stone or boulders n.exc 63 mm gauge , deposited , spread in layer n.exc 15 cm thick , watering and ramming to a true surface complete all as specified and directed.
Supply only Fine Sand complete all as specified and directed.
Spreading & levelling in layer n.exc 25 cm thick all as specified and directed.
S&F Steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp and staple ; erected in position as indicated, complete but gear operated type with bevel gear box and crank handle (Thickness of lath not less than 1.25mm ) complete all as specified & directed .
S&F MS screw bolts 12mm dia of neck (machine made) with hexagnal or square heads at one end and scewed the other, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10cm and not exc 15 cm long complete all as specified and directed.
S&F plates ( plain or chequered ) as per IS-3502 ( Base IS-10748 Gr-II ) and IS 1730-1989 square or rectangular cut or notched ( ordinary and counter shunk ) forming holes , without any attachment complete all as specified and directed .
M&L for applying three coats of white wash on new plastered surface of wall including preperation of newly plastered surface complete all as specified and directed.
M&L for applying two coats of Antifungal Acrylic Exterior Emulsion paint over a coat of primer in camouflange pattern on newly plastered surfaces of walls including preparation complete all as specified and directed.
S&F for vitreous China, semi-pedestal pattern (Anglo-Indian Type) water closet pan, white (excluding fixing bolts, flushing cisternand flush pipe), Seat and cover and trap , including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc, complete all as specified and as directed
S&F 10 litre capacity PVC valve less, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and 32 mm bore flush pipe of polyethylene complete all as specified and directed.
S&F chromium plated bib taps 15 mm bore cast copper alloy with crutch or butterfly handle, screwed for iron pipe fancy type complete all as specified and directed.
S&F chromium plated stop valve / angle valve 15 mm bore , cast copper alloy, fancy type , screwed for iron pipe complete all as specified and directed.
S & F 20 mm bore gun metal gate valve , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F PVC connection 15 mm bore with PTMT nut of length 450 mm complete all as specified and directed.
S&F 32 mm bore PVC flexible waste pipe of 1100 mm long for wash hand basin/Urinal complete all as specified and directed.
S&F Vitreous china Urinal bowl type flat back , size 465x 355x265mm white with grating and union for discharge pipe including providing and fixing plugs , bedding urinal against wall in CM 1:2 , securing urinal to plugs with and including 60 mm long brass screws , pointing around urinal back in cement complete all as specified and as directed .
S&F 110 mm dia PVC (SWR) pipe laid in floor complete all as specified and directed.
S&F 110 mm dia PVC (SWR) pipe laid on wall with clamps complete all as specified and directed.
S&F 75 mm dia PVC Floor trap complete all as specified and directed.
S&F 75 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in walls or in floors including clamps complete all as specified and directed.
S & F 110mm bore PVC (SWR) bends with access door of any radius complete all as specified and directed.
S & F 75mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F 110 mm bore, PVC (SWR) vent cowl complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate ) as in cills , copings , bed block including necessary formwork complete all as specified and directed.
S&F solid PVC door frames of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory made solid Panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for styles and Plain colour sheet PVC for top rails, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail supplied and fixed as per SSR instructions complete all as specified and directed.
S&F butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed,type B-21 100mm long complete all as specified and directed.
S&F aluminum anodised barrel tower bolts of extruded section 150mm long complete all as specified and directed.
S&F aluminum anodised bow handle fabricated type extruded section of 150mm long complete all as specified and directed.
S&F for Health faucet CP with 1.5 metre long flexible tube/pipe with wall hook/bracket to rest the faucet etc complete all as specified and as directed.
S&F for basin mixer single liver without popup waste system with 450 mm long Braided Hoses complete all as specified and as directed. .
S&F for wall mixer with provision for Overhead shower with 115mm long bend pipe on upper side, connecting legs & wall flanges complete all as specified and as directed.
S&F 20mm dia brass chromium plated tubular towel rails,D type,60 cm long between flanges,complete all as specified and as directed.
S&F 100 mm overhead shower round shape single flow (ABS Body chrome plated with gray face plate) with Rubit cleaning system complete all as specified and as directed.
S&F shower arm casted 160 mm long light body round shape for wall mounted shower with flange complete all as specified and as directed.
S&F 100 mm dia grating doom of PTMT (Minimum weight 25gms) complete all as specified and as directed.
S&F for toilet paper holder of brass,glossy finish complete all as specified and as directed.
S&F for Soap dish, brass chromium plated of suitable size, first quality, and fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S&F for Vitreous china urinal partition white of size 310x700 mm, etc complete all as specified and as directed.
Excavating over areas, n exc1.5 m deep and getting out in any type soil complete all as specified and as directed.
All as per item No 1.75 here-in before but for depth exc 1.5 and n exc 3.0 m complete all as specified and as directed.
Excavating in trenches not exceeding 1.5m wide and depth exc 1.5 and n exc 3.0 m for any type of soil and getting out complete all as specified and directed.
Excavating in trenches not exceeding 1.5m wide and depth exc 3.0m and n exc 4.5 m for any type of soil and getting out complete all as specified and directed. "Note for Item No. 1.75 to 1.78"- All excavation, RFR and removal of soil work will be done manually by Labour only.
M&L Cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M & L for Hardcore with broken stone or boulders n.exc 63 mm gauge , deposited , spread in layer n.exc 15 cm thick , watering and ramming to a true surface complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in foundation/mass concrete complete all as specified and as directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and as directed.
M&L for brick work with sub-class 'B' bricks one and half brick thick honey comb walls built in in cement mortar 1:4 complete all as specified and directed.
M&L Rendering 15mm thick in cement mortar 1:4 mixed with water proofing compound on fair masonry surface sand finished even and smooth without using extra cement complete all as specified and as directed. Note: (WPC will be measured and paid seperately).
M&L Rendering 10mm thick on masonry surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Removing excavated soils to a distance exc 100m but n exc 150m and depositing where directed complete all as specified and as directed.
M&L for mild steel TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking bending spirally for handle, rungs and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L Providing precast RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in cover slabs (for manholes and drains etc.), water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:6 including necessary formwork complete all as specified & directed. Note: Reinforcement shall be measured and paid for separately.
M&L for for RCC M-30 Design Mix for partition walls and the like any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed.
M&L formwork to rough finished surfaces of concrete edges of concrete flats, culvertes, slabs, trends, breaks in floors, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M & L formwork to vertical sides of partition RCC in rough finished rectangular surfaces of conrete complete all as specified and directed.
S & F for 100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to walls complete all as specified and directed.
S & F for 100 mm bore cast iron cowls complete all as specified and directed.
S&F 150 mm dia single "T" Junction CI drain pipes complete all as specified and directed.
M&L for 100mm thick cement concrete type B- 1 1:2:4 as in band using (20mm graded crushed stone aggregate) complete all as specified and directed.
M&L for Loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and directed.
M&L for Extra forming fair finished channel or drain 30cm inner girth in cement concrete using extra cement including mitred/stopped ends, forms mould etc, complete all as specified and as directed.
M&L for 150mm dia bore reinforced concrete pipes, class NP2 laid and jointed complete with collars complete all as specified and as directed.
M&L for Concrete bed to drain pipes of 150mm dia , 1:3:6 type C-2 (using 40mm grade stone aggregate) as in cradles complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregated in coping, benching ,for man holes including necessary from work and fnishing of exposed surface of concrete complete all as specified and as directed.
M&L for Plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in surface channel complete all as specified and as directed.
E/M PORTION
Supply, installation, testing and commsioinning of step down, Outdoor transformer with standard fittings, HT 11KV/433 Volts 3 phase 4 wire 50 HZ of 100 KVA capacity outdoor type, with off load tap changing arrangement on HT side to vary secondary voltage up to limit of +/-7.5% in step of 2.5% incl suitable cable entry boxes both on HT to receive 95 Sqmm 3 core XLPE cable of suitable size complete in all respect with standard accessories and fitment Sus for altitude of 9200 feet net temp -22 degri to+ 42 degri conforming to IS-1180 amended upto date . Primary side delta and secondary side star, the salient feature of transformer shall be as following :- (a) Transformer shall be oil immerse naturally self cooled copper wound , Winding core type, MS Radiator cooled tank complete with first fill of transformer oil plus 5 % spare oil as per IS 335 of 1980 with cooling system. The temprature of oil shall not rise more than 35 degree centigrade to ambient temp and 40 degree centigrade of ambient for winding transformer shall be painted with two coat of epoxy as per IS -632,Energy efficency level-2 (b) (i) Rating diagram plate (ii) Earthing terminal 2 numbers (iii) Lifting Lugs (iv) Thermometer (v) Air release hole with plug (vi) Tap changer with locking provn (vii) MS terminal box both on HT and LT side (viii) Oil temp indicator (ix) Explosion vent (x) Breather assembly with conservator" Note: Derating factor for high altitude of 9200 feet& temp -22 to +45 degri to be considered.
Supply and install Servo controlled oil cooled voltage stabilizer for automatic operation, Three phase naturally oil cooled indoor type and designed for input variation between 300V to 480V with output voltage stabilized at 415V with having voltage correction rate 8 Volt/Sec, per phase and of capacity 100KVA Complete all as specifed and as directed. Note (1): Derating factor for high altitude of 9200 feet& temp -22 to +45 degri to be considered.
Note (2): Servo voltage stabilizer shall confirm to BIS-9815 (Part-I) (i) Speed correction of vaoltage shall be not less than 8 V/s per phase. (ii) Efficiency servo voltage stabilizer not less than 95% as per clause 9.6 of BIS. (iii) Test report as per clause 11.1 for any rating as per clause 5.1 of BIS-9815 (Part-I) should be produced by the manufacturer for the specified capacity / next higher capacity of any voltage range from Govt. Lab / NABL accredited Lab. (iv) No load and full load losses corresponding to minimum and maximum rated input voltage shall be provided no load currect shall not be more than 5% of rated following shall be provided by manufacturer :- (a) Physical examination (b) Insulation resistance (c) High voltage test (d) Leakage current test (e) Output voltage (f) Measurement of no load loses (g) Induced voltage test shall be provide by the manufacturer.
Supply laying & testing Cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armoured,electric power cable (heavy duty) with stranded aluminium conductor,11000 Volts grade of size 3 core 95 Sqmm complete all as specified and as directed.
S&F cable jointing kit for 11KV grade cable for outdoor end termination Heat shrink type joint with jointing material and accessories suitable for 3 core XLPE Armoured cable 95 sqmm, complete all as specified and as directed.
S&F cable jointing kit for 1.1KV grade cable for outdoor end termination Heat shrink type joint with jointing material and accessories suitable for 3.5 core XLPE Armoured cable 120 sqmm complete all as specified and as directed.
Supply laying & testing cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armoured,electric power cable (heavy duty) with stranded aluminium conductor,1100 Volts grade of size 3.5 core 120 Sqmm complete all as specified and as directed.
Excavation in trenches in any type of soil,not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of pole/laying of pipes/laying of HT/LT cable and getting out any type soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
Sand cushioning for 8cm before laying the cable and then after laying the cables 15cm width of trenches for protection of cables including punning down the complete all as specified. Note:- thickness of sand cushioning shall be the thickness after punning down.
GI tube light grade of size 80 mm with all fittings laid in trenches or fixed to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable complete all as specified and directed by Engr in charge
M & L Danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with M.S clamps , bolts and nuts of approved size, for HT, 25mmX20mmX 1.6mm size complete all as specified and directed.
S&F only of un-reinforced precast concrete cable cover, class HVP, type 1 with peack, size 300mm x 180mm x 40 mm complete all as specified and directed by Engineer-in-Charge.
S&F brick tiles; common burnt clay building /ducts bricks’ sub-class `B’ Designation 75 (230mmx115mmx75mm) complete all as specified and directed by Engineer-in-Charge.
S&F APFC Panel with MPP-H-Capacitor PF capicity and MCB AS incomer KVAR Requied=KW(.547)= 43.28KVAR SAY 50KVAR 5 steps (25X2)complete all as specified and as directed
M&L for cross arms, bracings supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed by Engr-in-Charge.
S&F Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.0 metres long) including excavation , earth work complete all as specified and directed by Engr-in-Charge.
Supply, fixing, testing and commissioning of Air Break Gang Operated switch, triple pole mechanically operated out door type with all fittings/accessories mounted on and including 11 KV HT 15 Nos porcelain insulators of rating up to 400 Amps complete with drop out fuse assy having fuses of rating 200 Amps and steel channel frame, GI operating rod 25 mm dia of suitable length with operating mechanism worked form ground level, vertically operated including locking arrangement & operating handle, with and including padlock complete all as specified and as directed by Engr-in-Charge.
S&F Lightning arrestors expulsion type complete (Each Set -03 Nos ) with all fittings, transmission class, discharge capacity 65 kilo amp and high current with stand 100 KA outdoor type for 11000 volts, including clamps, nuts and bolts, washers and connection to earth wire 4 mm GI strip to Lightning arrester complete all as specified and directed by Engineer-in-Charge.
S&F, testing and commissioning outdoor type LT cubical panel CPRI apprroved Factory fabricated CRCA Sheet powder coated with structureal siemens grey RAL 7032 paint front and back openable and lockable by key from both side having louvers and air vent gasket and totally vermin proof made out of 3.15 mm thick CRCA sheet duly compartmentalized for incoming and outgoing laminated copper busbar suitable for 400 Amp duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators The incomer and outgoing shall have extension link two times the rating of individual feeder. All links shall be insulated with colour coded heat shrinkable sleeves having provision for termination of incomers and outgoing cables. All control wires shall be not less than 2.5 Sq mm multi stranded copper conductor and properly bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs.
M&L for Earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in ground (earth pit not less than 3.75 Meter deep below ground level) with top edge of the earth plate not less than 2.5mtr below ground level using copper earth strip 20 x 3 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including brazing etc of earth electrode and earth wire by means of welding, all as directed including providing watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 8 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion.
Note (1) : (i) Extra excavation of earth work more than 3.75 mtr shall be meassured and paid separately. (ii) The grid of earthing through earth strip to achieved earth resistance upto to 05 ohm shall be deemed into the quoted rate and no extra payment shall be made to contractor. (iii) The test point shall be made after the grid of earthing and algebric sum of strip with GI protation pipe shall be measured after 7.5 mtr earth pit.The strip beyond the total sum shall be paid seperately (a) Soil shall be provided by the contractor from outside the MOD land for refilling the remaining portion of earth pit for increasing soil conductivity The Low rasistivity .The rate of soil shall deemed to be included in the quoted rate and no extra payment shall be made on this account, bidders are requested to quote their rate accordingly. (c) Earthing will be carried out in presence of users and MES rep with entire satisfaction. (d) The ground enhansing material (GEM) / chemicals shall be added with soil and the GEM/chemicals shall be measured and paid seperately. Note (2) : Light grade GI Protection pipe of size 40mm shall be deemed to be including in the quoted rates.
M&L earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0 mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing strip protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified & directed by Engr-in-Charge.
Note 1- following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) M&L for for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal, dust, common salt and ground enhacement material as required to bring the earthing resistance as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2 - On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
M&L for Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw, complete all as per specified and as directed.
M&L for Surge Protection Device Three phase Type 1 (SPD) with serviceability indicator low voltage consumer system against lighting currents and surge voltage as they are tested SPD Type 1 According to Uc- 255v, ln-100kA (10/350us) Up 1.5KV The Device are compatible with system pro M Compact series The SPD with TS are optionally equipied with auxiliary contact with suitable size DB fixing of complete all as per specified and as directed.
M&L of GI strip 32x 6mm with saddless and fixing screws etc for roof conductors and down conductors above ground complete as specified and as directd.
M&L for Copper strip 20x 3mm with saddless and fixing screws etc for roof conductors and down conductors above ground complete as specified and as directed.
Supply and laying synthetic Rubber insulated mats 2.5 mm thick for voltage up to 11KV for electrical purpose as per IS 15652-2006 (supereding IS 5424) Suitable for electrical shock safety of sizes for ( 2x1mtr) 11000 Volts system complete all as specified & directed by Engineer -in-Charge.
M&L for Stay assembly complete woth accessories as shown in electric plate No-1 with dia of stay rod is 20 mm dia, 180 cm long including loop type insulator, stay clamps, excavation, concrete and stay wire, complete all as specified and directed by Engr-in-charge..
M&L for PCC 1:4:8 type D-2 (Using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete, complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (Using 40 mm graded crushed stone aggregate) as in copings etc complete all as specified and directed by Engr-in-Charge
S&F HT Bus bar .Out door type,suitable for 11000 Volts AC 3 Phase supply 630Amps ,Unit fabricated out of 3.15 mm steel enclosure suitable with MS Base Channel, the panel contains the equipment & componements complete with cooper bus bar interconnections designation labels caution notices and pad locking facilities wherever requied The size of the bus bar not less than 1200mmx1000mmx800 mm to accommodate the incomming and out going cable connection with front and back hinged doors with proper locking arrangement,rubber gasket on front and back to make it dust and vermin proof, powder coated. The cobicle shall have frame work, bottom and 50 cm long for legs off size 50x50x6mm engle iron. The panel shall be mounted on floor with PCC 1:2:4 type B-1 (with 20mm graded stone aggrigate) foundation block of suitable size upto 40cm above the ground and 60cm below the ground level. The panel shall be finished with powder coated paints-siemens grey ral 7032 the panel shall be fitted with following accesories (a)copper bus bar 50x12mm suitable raiting, TP, air insulated with color coded RYB heat shrinkable sleeves (b) Earth bus 40x6mm copper bus bar (c) dainger notice board Note: The quoted rate shall be deemed to include the cost of the PCC foundation.
Cutting of road (in hard/ dense soil) for laying pipe line or repair to pipes of any size upto 0.50 mtr. depth and getting out including forming bottom surface to required level and making good the road/wall as per existing bitumens, concrete complete all as specified and directed by Engineer-in-Charge
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of steel conduit drawn through PVC surface/concealed steel conduit and connected to main board and making good disturbed surface and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 4.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L for Sheet metal enclosures for DBs SPN 8 way flush mounted double door including accessories therein and disposing off complete all as specified and directed.
M&L for MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.
M&L for MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.
S&F Sheet metal enclosures with socket plug top and MCBs single pole and netural enclosure with a two pin and earth plug and socket complete one single pole 32 Amps Flush mounted complete all as specified and directed.
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated, 0.8 Bar pressure rating, SS tank complete with all accessories such as safety valve, thermostate, NRV, connection piece Hot and cold ss 304 pipe with fastiners, etc complete all as specifeid and directd
S&F Steel water tubing 40mm bore medium grade galvanised (ISI marked) with all fittings (such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc) etc complete all as specifeid and directd
S&F gun metal globe or gate valve (ISI) marked with iron wheel head, screwed both ends for iron pipe all as specified and as directed for the following sizes:-
Bore dia of pipe in 25mm
Bore dia of pipe in 40mm
M&L for Explosion proof point wiring for one light/bell/buzzer with 1.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangment including one number continuous run of 1.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, all as specified.
M&L for Explosion proof point wiring for one 3 pin 16 Amps socket outlet independent with 2.5 Sqmm 1100 Volts grade PVC FRLS insulated fire retrardent multi stranded flexible copper conductor cable in and including ERW rigid steel conduit ISI marked with all flame proof conduit fittings and accessories fixed on walls/ceiling with proper fixing arrangments including one number continuous run of 2.5 Sqmm PVC insulated fire retardent solid copper conductor cable as earth continuity conductor fixed to earth terminal and metallic body of light fittings/fan and socket etc complete all as suitable for Class Zone IE Ex II C for one light point controlled by one way switch, all as specified.
M&L for Explosion proof rotary switch single pole on and off with cable termination box of LM 6,16 Amps rating 230 Volts Class E EX II C suitable for class I Zone I, all as specified.
M&L for flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, (2P+earth) complete all as specified and direced.
S&F flame proof/weather proof Exhaust fan with Louvers 18'' 0.25HP, Single phase including cutting of suitable size hole /civ work with hole fastner complete all as specifed and as directed.
S&F LED light fitting 2x16 /20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc, complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specifed and as directed
S&F Flame proof with explosion protection MCB distribution board encloser single pole & neutral 240 volts 6 way complete with appropriate size bus bar and neutral link suitable for class 1 Zone 1 & Ex IIC suitable for & including following accessories : (i) MCB SP/2P 32Amps with rupturing capacity 16 KA - 01 Nos (ii) MCB SP 06 Amps with rupturing capacity 10KA - 04 Nos
M&L for Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion.
GI Steel wire 6mm with saddless and fixing screws etc for roof conductors and down conductors above ground complete as specified and as directed.
S&F Rotational moulded PVC water storage tank 500 ltr capacity, hoisted & fixed in position on 15 cm thick PCC 1:2:4 type B-1 bed with 4 Nos MS angle iron of size 50x50x5 mm, 1 mtr long fixed as support to tank complete all as specified and directed by Engineer-in- Charge.
Cutting of existing steel tubing for alterations or additions (Each Cut Measured) Complete all as specified and as directed.
M&L for Lagging to pipes used GI Pipe 25 mm in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming complete all as specifeid and as directed
M&L for Lagging to pipes used GI Pipe 20 mm in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming complete all as specifeid and as directed
M&L for valve pit masonary chamber of size 1.2x1.2x.3 mtr with MS plate 2 mm thick top cover locking arrangement 50 mm lock - 01 No Angle iron frame size 40x40x6 including painting with two coat of synthetic enamel paint over a coat of red oxide primer including excavation earth work, PCC plaster etc i complete all as specified and directed and shown on drawing complete all as specified.
COMMON NATURE ITEMS
S&F 15 mm bore GI tubing , medium grade with all fittings fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
All as per item No-4.01 above but 20 mm bore complete all as specified and directed.
All as per item No-4.01 above but 25 mm bore complete all as specified and directed.
Returning, filling in, including spreading,leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed.
DAVINDER SINGH (BID ID -3057339)
shivom builders (BID ID -3058516)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .