SOUTH DELHI MUNICIPAL CORPORATION OFFICE OF THE EX. ENGINEER (ELECT.)-WZ OLD ZONAL BUILDING, Ist FLOOR, VISHAL ENCLAVE RAJOURI GARDEN, NEW DELHI-110027
Provision for electrical fittings fixtures in Malaria office near B-Block Chand Nagar School, Vishnu Garden in Ward No.-07-S under West Zone. Subhead-Provision of EI, Fans and Compound Lighting.
2021_SDMC_86874_3
EE/Electrical/WZ/2021-22/12
Open Tender
Electrical Works
Works
30 days
RAJOURI GARDEN
Please refer Tender documents.
3 documents required · 3 mandatory
₹150
Exempted
10 Sept 2021
2 Sept 2021
10 Sept 2021
2 Sept 2021
9 Sept 2021
2 Sept 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 × 2.5 sq. mm + 1 × 2.5 sq. mm earth wire
2 × 4 sq. mm + 1 × 4 sq. mm earth wire
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.
5/6 amps switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply of XLPE insulated, PVC sheathed Al.conductor Armoured Cable 1.1 KV grade Conforming to IS-7098 of following Sizes:-
2 x 4 sq mm
S/I/T/C of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following . (a) Total system wattage 20 watt +/-5% (b) Luminous efficacy lumens/watt>=95 (c) Power Factor>=0.95
SITC of 60 W LED flood light luminaire fitted with lens, made of presure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 Protection (a) Total system wattage= 60 watt +/-5% (d) Luminaire efficacy>=100 Lm/w (e) Power Factor>=0.95 (f) Protection Class-IP-66
P/f of Hot press sheet moulded compound (SMC) Fire retardant (Temp. Resistance up to 200 C ) IP-55 weather proof pole box of inner dimension 200mm X 160mm X98mm (NS) complete with suitable arrangment for fixing of 2 no.s of 6 to 32 Amp single pole MCB &63 AmpDouble Pole isolator (MCB/isolator exculded) with neutral link duly shorting on DIN channel with 2 nos. of MS clamps with SS back plate of suitalbe size with Danger monogram properly printed on the cover etc as reqd.
supply, installation, testing and commissioning of Single/three phase Mono Block P/Set complete with all accessories workable on 240/415 volt. 50 Hz AC supply
1HP (0.75 KW ) Single Phase Pump Set Head frame 12.5 mt upto 25 mt Suction and delivery 25x25
Supply of 1200 mm Sweep 50 Watt, Energy saver ISI marked BEE 5 star rating AC Ceiling Fan suitable for 230 V, 50 Hertz AC supply without regulator with blades, downrod etc., complete as requred.
Supply of 12'' (300mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as reqd.
AMAN ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .