| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | I₹3.0 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | I | Accepted-AOC Being lowest | |
| 2 | II₹3.0 LRejected-Finance GALI NO 2 H NO 45 2ND FLOOR NANAK VIHAR COLONY LAL KUAN GHAZIABAD UTTAR PRADESH 201009 | GHAZIABAD | GHAZIABAD | UTTAR PRADESH | 201009 | II | Rejected-Finance Other then lowest | |
| 3 | III₹3 LRejected-Finance 86 NAROTTAM KUNJ MADHU NAGAR AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | III | Rejected-Finance Other then lowest | |
| 4 | IV₹3.1 LRejected-Finance 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | IV | Rejected-Finance Other then lowest | |
| 5 | V₹3.2 LRejected-Finance | V | Rejected-Finance Other then lowest |
Tender Value
Refer Docs
Closing Date
18 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Agra
GE (West) Agra
JOB ORDER FOR TAKING DOWN AND RE-FIXING OF ACs AND GEYSERs IN VARIOUS WARD/ DEPT AT MH AGRA UNDER GE (WEST) AGRA
2023_MES_588969_1
3340/Q/01/E3/2023-24
Limited
Miscellaneous Works
Works
30 days
GE (West) Agra
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
17 May 2023
11 Apr 2023
20 Apr 2023
12 Apr 2023
18 Apr 2023
12 Apr 2023
Amount
The undermentioned job order for : (a) M&L for disconnecting elect connection, taking down cafrefully of the window type complete AC unit of 1.5/2 TR from existing location and re-fixing the complete unit in new location after servicing including making all electric connection and necessary drilling of holes into a brick wall/ window for re-fixing the complete unit , temperature & gas pressure testing, gas charging, carpentry work, plumbing, masonry & white cementing and making functional the AC at new location all as specified and directed. Qty- 10 Each Job Note :- Drain Pipe, refrigerent gas , power plug, MCB and sub main wire to be paid under relevent item (b) M&L for disconnecting elect connection, taking down cafrefully the Split type AC unit of 1.5/2 TR Including indoor and out door unit from existing location and re-fixing the complete unit in new location after servicing including making all electric connection and necessary drilling of holes into a brick wall for connecting Indoor with outdoor unit’s pipes and connecting indoor and outdoor units with copper pipes and installation of drainage pipes and fxing outdoor unit on separately ODU stand, temperature & gas pressure testing, gas charging, carpentry work, plumbing, masonry & white cementing and making functional the AC at new location all as specified and directed. Qty-40 Each Job Note :- Drain Pipe, Copper pipe of required size, Refrigerent gas , power plug, MCB and Copper wire to be paid under relevent item (c) M&L for leak testing with nitrogen gas pressure as specified by the manufecturer of window/split type AC and rectifying the leakage if found by welding / copper soldering and testing after repair and holding pressure for minimum 2 hrs. Qty-40 Job (d) Supply & fixing heavy duty copper pipe 6 mm (1/4") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed. Qty-20 RM (e) -ditto- all as per item No. 4 above but copper pipe 12 mm (1/2") dia/ bore. Qty-18 RM (f) -ditto- all as per item No. 4 above but copper pipe 15mm (5/8") dia/ bore. Qty-25 RM (g) -ditto- all as per item No. 4 above but copper pipe 18mm (3/8") dia/ bore. Qty-25 RM (h) S&F flexible PUF form type insulation for copper pipe, supply and fixing new insulation for copper pipes suitabale for Split AC of capacity from 1.5 & 2.0 TR all as specified and directed. Qty-88 RM (j) S&F PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC of capacity from 1.5 & 2.0 TR all as specified and directed. Qty-80 RM (k) M&L for refrigerent gas (R-22) chaeging to the split type AC of capacity 1.5/2.0 TR up to required pressure approx 1.8 kg each and testing complete all as specifiedd and directed. Qty-32 Each (l) M&L for refrigerent gas (R-22) chaeging to the window type AC of capacity 1.5/2.0 TR up to required pressure approx 1.2 kg each and testing complete all as specifiedd and directed. Qty-05 Each (m) Material & Labour for disconnecting, desmentling and taking down carefully of water heater (Geyser) of capacity 25/35/50 Ltrs and re-fixing at new loaction as directed by Engineer-in-charge of any size by making all electric connections including hot and cold water connections and making good surface body by painting (one coat) of water heater (Geyser) complete outer body by spray painting with synthetic enamel white paint complete all as specified and directed at site. Qty-23 Each Job (n) S&F for 15mm dia stop cock, cast copper alloy, out side thread, high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified & directed. Qty-20 Each (o) S&F in replacement bib taps 15mm bore, cast copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed. Qty-10 Each (p) S&F for PVC connection 15mm bore, 450mm long in any position with both end brass nut with inner threading and washer suitable for cold water connection complete all as specified & directed. Qty-23 Each (q) S&F for heavy duty heat resistance PVC connection 15mm bore,450mm long in any position with both end brass nut with inner threading and washer suitable for Hot water connection complete all as specified & directed. Qty-23 Each (r) S&F for fastener mild steel 100 mm long x 10 mm dia with pin and bolts complete for hanging of geyser and making good the disturbed surfaces including plastering and white washing complete all as specified & directed. Qty-46 Each (s) S & F for galvanized iron tubes, medium grade of size 15 mm bore fixed to wall, ceiling and laid under floor complete all as specified and directed. Qty-80 RM (t) Supply & fix for single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified & directed. Qty-10 Each (u) M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Qty-112 RM Notes:- Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 2.5 sqmm cable for earth continuity alongwith PVC conduit including its accessories shall be measured and paid one unit length. (v) M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Qty-132 RM Notes :- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable for earth continuity alongwith PVC conduit including its accessories shall be measured and paid one unit length. (w) Supply & fix for MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. Qty-10 Each Note:- Old retried items will be contractor property.
M/s A K Engineering Co
M/s J S & SONS
M/S OM Enterprises
M/S R.K ENTERPRISES
M/s Lord Krishna Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_659860.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .