| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.9 LAccepted-Finance | L1 | Accepted-Finance OK | |
| 2 | L2₹88.5 L+₹2.5 L (2.96%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹89.9 L+₹3.9 L (4.58%)Accepted-Finance 5 49 SUBASH NAGAR BEHIND SBI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Accepted-Finance OK | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹94.9 L
EMD Value
₹1.9 L
Closing Date
10 Apr 2021, 2:00 pmClosed
EXECUTIVE ENGINEER ED REASI
HALL 301 DC COMPLEX REASI
in District Reasi (JK) on turnkey basis under CAPEX BUDGET 2020-21.
2021_PDD_121079_1
e NIT 43 of 2020-21 dated 20.03.2021
Open Tender
Electrical Works
Turn-key
15 days
in jurisdiction of Electric Division Reasi
As per tender documents
3 documents required · 3 mandatory
₹2,000
EXECUTIVE ENGINEER ED REASI
₹1.9 L
OFFICE OF EXECUTIVE ENGINEER ED REASI
1 May 2021
22 Mar 2021
12 Apr 2021
22 Mar 2021
10 Apr 2021
22 Mar 2021
22 Mar 2021 - 8 Apr 2021
8 Apr 2021
Amount
Supply, Transportation, manual carriage, Erection, Testing And Commissioning for laying of 11KV HT lines for 63KVA Sub stations and 100KVA Substations as per scope mentioned in SBD in jurisdiction of Electric division Reasi
9 mtr long Pole ST-410, SP33
GI V Cross Arm with Top Brackets including clamps and GI Channel X Arm/Angle Iron/Flat iron including clamps and braces
11kV Link set 3-Phase, 3-Pole, 200 Amp, Vertical Type
ACSR Weasel Conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvinized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete.
Supply, Transportation, manual carriage, Erection, Testing And Commissioning for creation of 63KVA substations(5Nos) and 100KVA sub stations (4 Nos.) as per scope mentioned in SBD in jurisdiction of electric division Reasi
11/0.433KV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) and with LV cable box having detachable Aluminium Gland plate
11/0.433KV, 3-phase 100 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound) and with LV cable box having detachable Aluminium Gland plate
9 mtr long Pole ST-410, SP33
Gapless Surge Arrestor, 9kV, 10kA, LA with polymer housing, Station type
11KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, vertical type
11kV Horn Gap Fuse set 3-phase, 200 Amp
95sqmm cable 1.1kv grade, PVC insulated stranded conductor FRLS type for 63kva sub stations
120sqmm cable 1.1kv grade, PVC insulated stranded conductor FRLS type for 100KVA sub stations
11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of different sizes including clamps
Galvanised Nuts & Bolts
Earthing of substation - Excavation of earthing pit of dia 650mm & depth 3000mm, installation ofEarthing pipe of 40mm nominal bore & 4mm wall thickness & length 2.5 mtr long as per IS 1239. GI strip for neutral earthing of size 25mm x 3mm for connection of transformer body, GO set & lightening arrestor as per IS 2629/85, GI nuts & bolts, refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover
LT distribution box for 63KVA DTR with MCCB for incomer & SFU's for outgoing circuits
LT distribution box for 100KVA DTR with MCCB for incomer & SFU's for outgoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with clamps
G.I Barbed Wire for anti climbing
3 Phase 4 Wire Trivector meter with CT PT combo unit
Cement bottoming 1:2:4 mix as per REC standards .5cum/Pole
Painting of Poles Red oxide
Painting of Poles Aluminium Paint
Supply, Transportation, manual carriage, Erection, Testing And Commissioning for laying of LT lines at 63KVA Substations and 100KVA Substations as per scope mentioned in SBD in jurisdiction of Electric division Reasi
8 mtr long Pole ST-410, SP15
GI M Clamp for shackle Insulator
ACSR weasel Conductor
16 KN Polymer Shackle Insulators
Galvanised Nuts & Bolts
Danger Plates with clamps
Earthing Complete by GI Pipe 40mm or GI Rod 20 mm 2.5 Meter long through GI Strip
Red Oxide
Aluminium Paint
Anti-Climbing Device with Clamps
Cement Bottoming 1:2:4 mix as per REC Standards .45CUM/Pole
LT Line Spacers
Galvanised Stay setwith 50x8mm stay clamp, Guy Insulator (2 Nos), Anchor Plate (200x200x6mm) nuts and Bolts, 2Nos Turn Buckles, 1.8 long, 16mm diameter solid GS Stay rod & 7/3.15mm dia GI Standard wire complete
Abdul Hamid and Sons
V-RIDGE ENGINEERING WORKS.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .