Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 CrAccepted-AOC DADRA AND NAGER HAVELI DN | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396193 | ₹6.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹6.7 Cr+₹21.5 L (3.31%)Rejected-AOC 475 OPP DAMAN GANGA COLONY GAYTRI MANDIR ROAD AMLI SILVASSA 396230 U T OF D NH | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396230 | ₹6.7 Cr+₹21.5 L (3.31%) | L2 | Rejected-AOC L2 |
| 3 | L3₹6.9 Cr+₹43.5 L (6.69%)Rejected-AOC DADRA AND NAGAR HAVELI DN | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396193 | ₹6.9 Cr+₹43.5 L (6.69%) | L3 | Rejected-AOC L3 |
Tender Value
₹4.5 Cr
EMD Value
₹9.1 L
Closing Date
24 Feb 2024, 12:00 pmClosed
Executive Engineer PWD.II Road, DNH, Silvassa
Executive Engineer PWD.II Road, DNH, Silvassa
Renovation of Entrance Gate at Naroli, Dadra, Morkhal, Khedpa and Kherdi and Construction of New Entrance Gate at Velugam in Dadra and Nagar Haveli.4th Call
2024_UTDNH_6971_1
E-Tender Notice No. 23 of 2023-24 (Road)
Open Tender
Civil Works
Item Wise
305 days
Executive Engineer PWD.II Road, DNH, Silvassa
Documents as per NIT
3 documents required · 3 mandatory
₹1,500
Executive Engineer PWD.II Road, DNH, Silvassa
₹9.1 L
Yes
2 Mar 2024
17 Feb 2024
24 Feb 2024
17 Feb 2024
24 Feb 2024
17 Feb 2024
Amount
Excavation for foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto all lift & lead.(A) Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking of useful materials and disposing off the excavated stuff upto all lift & lead.(C) Hard Murrum
Filling available excavated earth (excluding rock) in trenches. plinth, sides of foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited layer by ramming and watering.
Providing material and labour for filling in foundation and plinth with RUBBLE under floors including filling gravel in gaps and consolidating deposited layers by ramming water etc. Complete.
Excavation for Auger 300mm Dia. And 2.70m Deep including removing the excavated material upto all lift & lead. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. during time of excavation existing structure to be supported with required scafoling.etc.complete.
Providing preconstructional antitermite treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing material and labor for cement concrete 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal size) and curing complete excluding cost of formwork in (A) Foundation and Plinth
Providing material and labour for laying controlled cement concrete M.250 and curing complete including the cost of formwork but excluding reinforcement for reinforced concrete work in (A) Foundations, footings, Base of columns and Mass concrete, as directions of Chief Engineer in charge Complete.
Providing material and labour for laying controlled cement concrete M.250 and curing complete including the cost of formwork with sheathing steel and excluding the Cost of reinforcement for reinforced concrete work in (D) Columns, Pillars posts and struts upto all level. etc complete as directed by Engineer-incharge.
Providing material and labour for laying controlled cement concrete M.250 and curing complete including the cost of formwork with sheathing steel and excluding cost of reinforcement for reinforced concrete work in Lintels, Beams, Girders and Cantilever upto all level etc complete as directed by Engineer-incharge
Providing material and labour for laying controlled cement concrete M.250 and curing complete including the cost of formwork with sheathing steel and excluding cost of reinforcement for reinforced concrete work in (C) Slabs, landing, shelves and Cantilever upto all level, etc complete as directed by engineer-incharge.
Providing material & labour for laying Rebar in Existing Column, Beam and Slab as per drawing and specification complete.
Providing material and labor for TMT Bar FE 500D reinforcement for R.C.C. work including applying anticarrasive treatment with polymer base materials to the steel rainfarcement including descaling the dust and applying the preventive coating of approved make, bending, binding and placing in position complete upto Slab level. Make: TATA, JINDAL, JSW, SAIL, ELECTRO, THERMAL or EQUIVALENT.
Providing material and labour for brick work using common burnt clay building brick having crushing strength not lss than 35 One Kilogram/sq.cm. in FOUNDATION AND PLINTH LEVEL in cement mortar 1:5 (1 cement : 5 fine sand (A) Modular including curing etc. complete.
Masonary work using Aerated light weight concrete block having crushing strength not less than 35One Kilogram/sqcm for superstucture upto all level with ready to use, high strength adhesive jointing mortar, complete as per Technical specification or as directed by engineer-in-charge.
Uncoursed Rubble Masonry with hard stone of approved qualityin foundations and plinth in Cement Mortar 1:6 (1-cement : 6-coarse sand including levelling up etc. complete
Uncoursed Rubble Masonry with hard stone of approved qualityin Extra over Item 7.6 For Super Structure above plinth level upto floor two level Cement Mortar 1:6 (1-cement : 6-coarse sand including levelling up etc. complete
Providing material and labour for 6mm thick cement plaster in single coat on SLAB ceiling surface for plastering upto all level finished leven and smooth including curing etc. complete in C:M (1cement : 3 fine sand ) and finished with floating coat of neat cement slurry. as directions of Chief Engineer in charge Complete.
Providing material and labour for 15mm thick cement plaster in single coat with mala finish on brick concrete wall surface for plastering upto all level finished even and smooth including curing etc. complete in C:M (1cement : 3 fine sand ) as directions of Chief Engineer in charge Complete.
Providing material and labor for 20 mm thick rough finished cement plaster on walls upto height 10 metres above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick rough finishing coat of C.M. 1:1 (1-cement : 1-sand) on exterior brick / concrete work for reciving texture paint's base coat etc. complete. For plastering upto all level complete. as directions of Chief Engineer in charge Complete.
Providing material and labor for applying Two coats of wall care Putty & two coat of primer of approved brand and manufacture on new wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.as directed by engineer in charge complete. Make: Birla White.Asian Paints, JK Wall Care Putty or equivalent
Providing material & labour for Internal Wall painting (two coats) with Lustre paint of approved brand and manufacture including primer coat on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. as directed by engineer in charge complete. Paint should be washable grade Make: Jotun JollyFix, Asian Paints Royale, Berger Paints - Bison Glow, Dulux Paints -SuperClean or equivalent.
Providing material and labour for fixing ISI marked Single Shutter flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with including ALUMINIUM SECTION frames 15 cm x 7 cm 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws, with Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS :2046 Type S, including cost of adhesive of approved quality 1.0mm Thick on both face, with Providing and fixing S.S. tower bolts (barrel type) with necessary screws etc 200mm long x10mm dia, with Providing and fixing S.S. Door Aldrop with necessary screws etc. 300mm long x16mm dia, Providing and fixing S.S. Door Aldrop with necessary screws etc 250mm long x16mm dia, with Providing and fixing S.S. Pipe Handle for door 30cm size on both side of Door shutter, with Providing and fixing S.S hanging type floor door stopper with necessary screws, etc. complete as directed by Engineer in charge. All S.S Shall be ASIS 304 Grade. Plywood Make:- Century Ply Laminates, Greenply Industries Limited, SRG Ply & Boards or equivalent.
Providing material and labour for fixing ISI marked Single Shutter flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with including 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws, with Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS :2046 Type S, including cost of adhesive of approved quality 1.0mm Thick on both face, with Providing and fixing S.S. tower bolts (barrel type) with necessary screws etc 200mm long x10mm dia, with Providing and fixing S.S. Door Aldrop with necessary screws etc. 300mm long x16mm dia, Providing and fixing S.S. Door Aldrop with necessary screws etc 250mm long x16mm dia, with Providing and fixing S.S. Pipe Handle for door 30cm size on both side of Door shutter, with Providing and fixing S.S hanging type floor door stopper with necessary screws, etc. complete as directed by Engineer in charge. All S.S Shall be ASIS 304 Grade. Plywood Make:- Century Ply Laminates, Greenply Industries Limited, SRG Ply & Boards or equivalent.
Providing, supplying & fixing of glazed Openable TWO TRACK/THREE TRACK Window in slider/slide up/vertical/casment type with wooden texture or any other finish as instructed by archtiect or engineer-in-charge, made out of multi-chambered ALUMINIUM sections with TPV gaskets having isolated drainage and reinforced with Galvanised Iron profiles throughout the window. The outer frame having a overall size of 60 x 55 mm with reinforcement of 1 mm thickness, mullion with overall size of 74 x 60 mm with reinforcement of 1 mm and sash with overall size of 75 x 60 mm with reinforcement of 1.5 mm thickness. Glazing bead for fixing of glass shall be of size 34 x 20mm and coextruded with gasket. Composition of profile shall consists a minimum of 8 PHR of TiO₂ for every 100 parts of PVC resin. Windows shall be provided with 5 mm plain float glass, standard hardware, multi-point locking system and friction stays. Wall thickness of frame, mullion & sash shall be 2.2 - 2.4 mm
Providing, supplying & fixing of Fixed Louvered Ventilator made with wooden texture or any other finish as instructed by archtiect or engineer-in-charge,out of multi-chambered ALUMINIUM sections with TPV gaskets having isolated drainage and reinforced with Galvanized Iron of 120 GSM profiles through out the window. The outer frame having a overall size of 60 x 55 mm with reinforcement of 1 mm thickness and Mullion with overall size of 74 x 60 mm with reinforcement of 1 mm thickness. Composition of profile shall consists a minimum of 8 PHR of TiO₂ for every 100 parts of PVC resin. Ventilator shall be provided with 4.5 mm Pin Head glass, standard hardware. Wall thickness of frame & Mullion shall be 2.2 - 2.4 mm Accessories: Glass holding flanges made of polypropylene. Assembling & Installation: The Frame Sections should be cut to length and mitre joined with Corner Bracket made of Nylon. Window Frame should be fixed to brick/ concrete masonry by using Nylon self-expanding sleeves and driving MS electroplated 80mm long screws into the sleeves through the frames.
Providing material and labor for fixing pre-cast concrete finish kerbs including Transition , Dropper & offlet kerbs, Radius kerbs, angle & Quadrant Kerbs, concrete block 600mm length, 300mm height and 150mm thick of M250 grade concrete as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete.
Providing material & labour for fixing pre-cast concrete shotblasted paver block 80mm thick as per design with percentage of water absorption not more than 6%, compresive strength not less than 250 kg/One square meter. Tensile splitting strength (as per EN 1338) not less than 3.6 Mpa any colours as per approved design including 75mm Sand layer for levelling and filling the joint with sand in proper line and level etc complete.
Providing & laying Vitrified tiles 8 to10 mm thick,24"x24" in flooring treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 ( 1 cement: 3 coarse sand) finishing with flush pointing in white Cement. For flooring. Make: Nitco, Simpolo, Kajaria or equivelant
Providing & laying Vitrified tiles 8 to 10 mm thick,24"x24" in Skirting risers of steps and dedo on 10mm thick cement mortar 1:3 ( 1 cement: 3 coarse sand) and jointed with white cement slurry. complete. For Skrting Make: Nitco, Simpolo, Kajaria, jonson equivelant (Primer quality)
"Providing material & labor for laying 24""x24"" Anti-Skid Vitrified 8 to 10 mm thick tile flooring over 20 mm (average) base of cement mortar 1:4 ( 1 cement: 4 coarse sand) on new surface or fixing on existing flooring by adhesive material including dismantling of existing flooring and spacer of required size to be provide while fixing the tile. Tiles joint grooves to be filled with epoxy. including finished with flush pointing & cleaning the surface etc. complete or as directed by engineer-in-charge Make: Nitco, Simpolo, Kajaria, johnson, Rak or equivalent"
Providing material & labour for laying Vitrified tiles 8 to 10 mm thick 300x450mm , in required size for dado on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry including finised with flush pointing & cleaning the surface etc. complete or as directed by engineer-in-charge. For Dado Make: Nitco, Simpolo, Kajaria,johnson, Rak or equivelant.
Providing material & labour for Fixing 18 mm thick Granite slab (18mm thick) 1 side mirror polished, premoulded and prepolished) machine cut for platforms, vanity counters, door window,sills,jambs,soffits facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding on all exposed edges and polishing to edge to give high gloss finish etc. complete. at all levels.
Providing material & labour for stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade. FOR URINAL PARTITIONS
Providing material and labour for making Black Granite stone Counter Wash Basin of 0.60mt wide with vertical & Horizontal Support of granite stone and having bottom slab of 25mm to 30mm thick kadappa stone fixing with cement motar 1:4 (1 Cement :4fine sand) and neat cement slurry as per requirement including cutting the granite stone & providing 7 fixing oval shape wash basin of 22''x16" size white colour in line & level. All exposed Edges of granite should be moulded including all accessories like pillar cock (Swan neck type), fexible inlet pipe 15mm dia, C.P. brass waste coupling 32mm, PVC Waste pipe 32mm etc. as directed by Enginner on Charge. LABORATORY COUNTER TOPS AND WASH BASIN COUNTER
Providing material & labour for laying 18mm to 20mm thick red sandstone for cladding work on 10 to 15 mm thick cement plaster 1:3 (1-cement : 3-coarse sand) with Chemical additives LATICRETE® 325 Shear Wall Adhesive or equivalent for strengthening the vertical bond of stone with base surface including finised with flush pointing & cleaning the surface etc. complete or as directed by engineer-in-charge. Size of Stone as per approved achitectural drawing Size 450x900mm or as directed by engineer-in-charge
Providing material & labour for laying 18mm TO 20mm thick yellow sandstone for cladding work on 10 to 15 mm thick cement plaster 1:3 (1-cement : 3-coarse sand) with Chemical additives LATICRETE® 325 Shear Wall Adhesive or equivalent for strengthening the vertical bond of stone with base surface including finised with flush pointing & cleaning the surface etc. complete or as directed by engineer-in-charge. Size of Stone as per approved achitectural drawing Size 450x900mm or as directed by engineer-in-charge
Providing and fixing sandstone cornice on the borders for Architectural elevation work of entrance gate in approved size, pattern, design, thickness15 to 20 mm and color as per cladding having height of 400 to 600mm and 6 to 8 steps of 50mm to 100mm each as per the approved architectural design complete or as directed by engineer-in-charge
Providing material and labour for applying Chemical Waterproof Coating PU One Coat epoxy primer and Three coat polyrethane coating including preparation of surface as required for terraces and Toilets. as approved by the Chief engineer-incharge with a guarantee of 10 years. Complete. Make:- MYK Arment, Pidilite, Sika or equivelant.
Providing material, Labour and equipments for Providing and laying integral Cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations : a) Applying a slurry coat of neat cement using 2.75 kg/One square meter of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer in charge over the RCC Slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junction of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg / One square meter of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge. d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300 x 300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer in charge : Including Khurra & Gola work with average thickness of 120mm and minimum thickness at Khurra as 65 mm etc. complete as directed by Chief Engineer in charge.
Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 Lit/10 One square metert. Over an under coat of primer applied @ 0.80Lit/10 One square metert. Of approved brand and manufacture.
Providing material and labor for GARDEN SOIL:- Supplying on site garden soil well sieved 90% to pass through I.S. sieve of 10mm size free from stones rubbish like dried grass roots and other such materials. The soil should be ftesh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box.(Farma) (Item includes Royalty charges,, Transporting, Ioading unloading etc.) lead charges for 30 k.m. is considered.
Providing material and labor FARM YARD MANURE : Supplying on site well decayed, well dried, well powdered, without clods and free from stones, dried grass and other rubbish material. The colur of the manure generally be black. The manure will be measured by measuring box. (Farma) (Item includes Transporting, loading unloading etc.) lead charges for 20 km is considered.
Providing labour for MIXING GARDEN SOIL/SILT & MANURE THROUGHLY WELL, Watering Pervious night, Planting required plant species, lawn gress as dricted etc. complete.
Providing material and labor for TREES:-(minium height to 3 mtr.):- digging pit with size 0.9mx0.9mx0.9m removing and conveying unwanted stuff to a required stuff to arequired diatance as directed. Filling the pit with approved excavted material up to a height of 0.30m. And remining height of 0.60m with fresh garden soil and manure in 3:1 proporation . mixing soil and manure thoroughly well, levelling, as directed , watering previous night, planting two to three year old , minium 2.0 mtr. height , healthy trees sapling as per specification. maintaning till well established by watering , weeding, stirring of soil staking replacing of casualties etc. complete.
TREES:-Supply and erecting Palm tree (minium height to 2.5 mtr)- digging pit with size 0.9mx0.9mx0.9m removing and conveying unwanted stuff to a required stuff to arequired diatance as directed. Filling the pit with approved excavted material up to a height of 0.30m. And remining height of 0.60m with fresh garden soil and manure in 3:1 proporation . mixing soil and manure thoroughly well, levelling, as directed , watering previous night, planting two to three year old , minium 2.0 mtr. height , healthy trees sapling as per specification. maintaning till well established by watering , weeding, stirring of soil staking replacing of casualties etc. complete.
TREES:-Supply and erecting Morpankhi Hedges (minium height to 2.5 mtr)- digging pit with size 0.9mx0.9mx0.9m removing and conveying unwanted stuff to a required stuff to arequired diatance as directed. Filling the pit with approved excavted material up to a height of 0.30m. And remining height of 0.60m with fresh garden soil and manure in 3:1 proporation . mixing soil and manure thoroughly well, levelling, as directed , watering previous night, planting two to three year old , minium 2.0 mtr. height , healthy trees sapling as per specification. maintaning till well established by watering , weeding, stirring of soil staking replacing of casualties etc. complete.
HENNA PLANTATION :- Excavting the ground to required depth of 30 cms, removing and coveying unwanted stuff to a required depth as directed. Filling fresh garden soil and manure in excavted area 3:1 poroporation to a height of 30 cms. Mixing garden soil and manure thoroughly well developed shurbs plants, 0.50 mtr. height, 0.45mtr.apart as directed and maintaining till well eastabilished by watering, weeding, stirring, replacing casualtiies etc. complete
TREES:-(height upto 1.50 mtr.)- digging pit with size 0.9mx0.9mx0.9m removing and conveying unwanted stuff to a required stuff to arequired diatance as directed. Filling the pit with approved excavted material up to a height of 0.30m. And remining height of 0.60m with fresh garden soil and manure in 3:1 proporation . mixing soil and manure thoroughly well, levelling, as directed , watering previous night, planting two to three year old 1.5 height , healthy trees sapling as per specification. maintaning till well established by watering , weeding, stirring of soil staking replacing of casualties etc. complete.
TREES:-Supply and Traveller Palm tree (minium height to 0.300 To 0.600 mtr)- digging pit with size 0.9mx0.9mx0.9m removing and conveying unwanted stuff to a required stuff to arequired diatance as directed. Filling the pit with approved excavted material up to a height of 0.30m. And remining height of 0.60m with fresh garden soil and manure in 3:1 proporation . mixing soil and manure thoroughly well, levelling, as directed , watering previous night, planting two to three year old , minium 2.0 mtr. height , healthy trees sapling as per specification. maintaning till well established by watering , weeding, stirring of soil staking replacing of casualties etc. complete.
Providing material and labor for fixing LASER CUT STONE LOGO FOR "U.T.ADMINSTRATION OF DADRA & NAGAR HAVELI & DAMAN & DIU WELCOME YOU" (Size: 21000mm x 600mm) -3D LASER CUT letters flushed in R.C.C. BEAM. - Letters be fix in RCC beam/slab while casting with propare clamp and anchor fastener. - Provision for engraving of 3mm to accomodate led profile light installation to be provided in each letter LED Light - 3smd module -Making all necessary provision of material and electric wring etc fittings, fixtures and cleanliness as per detailed design and drawing or as directed by engineer in charge. LED Back lit: -The workmanship shall be of high standards and engineering
Providing material and labor for reinstalling existing "STATUE" at the desired location as per approved drawing including cleaning, scraping, repainting the surface with deco paint etc complete as directed by engineer-in-charge -Making all necessary provision of material and electric wring etc fittings, fixtures and cleanliness as per detailed design and drawing or as directed by chief engineer in charge. -The workmanship shall be of high standards and chief engineering.
Providing material and labor for fixing FRP sculpture stuatue (HEIGHT OF STATUE =3.00M,Width=7.000m) FRP architectural structures With Exterior Grade deco paint on Visible Surface. sculpture shaped statue made up of fiberglass reinforcement plaster using isohaline resin & 450 GSM powered bonded mat hardener & further coloring it to give effect as directed by engineer in charge & design complete as given by architect
Dismentaling the existing structure including removing and stacking the dismentelled materials as and where directed. (A) R.C.C. work
Dismentaling the Paver Block including removing and stacking the dismentelled materials as and where directed.
Demolition of Brick work and stone masonry including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar.
Demolition of Natural Stone Cladding including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.(ii) In Cement Mortar.
Removing and scraping of old deteriorated plaster of any thickness fromm wall / R.C.C member including stacking of serviceable material and disposal of unserviceable from site of work with all lead and lift
Removing Electrical Pople & Light &Wire including stacking of serviceable materilas and disposal of unserviceable materials with all lead and lift.
Dismentling doors, windows, ventilators etc. (wood or steel) shutters including chowkhats architraves, holdfasts and other attachment etc. complete and stacking them within all lead and lift.(i) Not exceeding 3 Sq.M. in area.
Dismantling of sheet roofing including ridges, Hips, Valley, gutters, etc. Stacking of serviceable material and disposal of unserviceable material with all lead & lift (i) GI sheet roofing
Dismentling steel work including distempering and stacking the materials with all lead and lift.
Dismentaling the KERB STONE including removing and stacking the dismentelled materials as and where directed.
Providing and fixing in position cowel went to pipes.(B) 75mm dia.
Providing and fixing wall hung wsh down water closet (European type, W.C. Pan) with integral P or S trap including jointing the trap with soil pipe in Cement Mortar 1:1 (1- Cement : 1-fine sand) (Seal and cover to be measured and paid for separately)(A) vitreous China Pattern :(i) in white colour of approved make Jaquar, cera, Hindware or its equivalent
Providing and fixing plastic seat and cover for wash down water closer with C.P. brass hinges and rubber buffers. (B) Black plastic seal and cover.
Providing and fixing toilet paper holder.(A) C.P. Brass
Providing and fixing 12.5 Litres low level flushing cistern with a pair, of C.I. or Mild brackets, complete with fittings such as lead valve less syphon, 15mm nom.nal size brass ball valve with polythene float, C.P brass handle unions and couplings for connections, with inlet, outlet and overflow pipes, 40mm dia. porcelain enamelled flush bend including cutting holes in walls and making good the same connecting the flush bend with cistern and closet (overflow pipe to be measured and paid for separately)(A) Vitreous China (I) In white colour
Providing and fixing washbasin with single hole for pillar tap with C.I. or M.S. brackets painted white including sutting holes and making good the same but excluding fittings.(A) Vitreous China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In white colour.of approved make Jaquar, cera, Hindware or its equivalent
Providing and fixing C.P. brass waste for washbasin or sink. (B) 40mm dia.
Providing and fixing M.I. fisher union for washbasin or sink. (B) 40mm dia.
Providing and fixing 600mm x 450mm bevelled edge mirrror of superior glass mounted on 6mm thick A.C. sheet or plywood sheet and fixing to wooden pluge with C.P. brass screws and washers.
Providing and fixing chromium plated, bottle trap with necessary couplings of approved quality for wash basin.
Providing and fixing screw down bib taps of following size.(B) Brass chromium plated screws down Bib Tap. (i) 15mm dia.
Providing and fixing Gun metal check or non-return fullway wheel valve.(D) 32mm dia.
Providing and fixing Urinal or approved quality including conecting the Urinal with waste pipe , tap etc. complete.(A) White earthenware flat back or corner type size 430mm x 260mm x 350mm.
Providing and fixing chromium plated brass half trun flush cock of approved quality including fixing in pipe line etc. complete.(i) 20mm dia.
Providing and fixing ball cock of approved. quality as directed.(B) Abonite (ii) 50mm dia.
Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls.
Providing erecting and fixing double coated ISI water tank of required capacity each with all necessary fittings and connection etc. complete on terrace
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps. (A) 100mm x 100mm size P type.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1- cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:3 (1- Cement : 3-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (2) B type depth 1.50 Metre for 150mm diameter sewer.
(II) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. GR Part thereof over item No.24.27 (I) for depth from 1.50M. to 2.25M.
Providing and fixing Health Fauset Heavy duty with hook with fitting
Providing laying and jointing U PVC SCH40 for cold water 20 mm dia (3/4)" including it's accessories.
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in below type of pipe erected with 6A Modular type switch / bell push & accessories and earth continuity of following type, erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete cat III
Point wiring for secondary light point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires, in below type of pipe to be erected complete with earth continuity and necessary connection with primary light with accessories erected on Metal / PVC / wooden box covered covered with appropriate front plate modules erected on / in wall / ceiling for open / concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector as directed.as per pipe erected with following type of accessories. (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete cat III
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected with 6A Modular type switch and hum free EME four or more step type electronic fan regulator with separately mounted and accessories with earth continuity of following type erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete cat III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires erected in below type of pipe with 6A Modular type switches and following type of accessories erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured / metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary batten/angle holder or ceiling rose or H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete cat III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db board.(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete cat III
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected with following type of accessories. [I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board (f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete
Providing & erecting Switch board for Computer or electric apparatus consisting of following modular type accessories mounted with PVC / Metallic concealed/open box with single mounting base frame covered with textured/metallic /white front plate,modules erected with necessary connections as directed 1 no. 6A/16A universal plug-switch combined. 3 nos. 6A Switch 3 nos. 6A 5 pin Plug For Modular Type Accessories Cat. III
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. (f) One wire 10.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor starters & control wiring) with required size of copper lugs, nuts and bolts if required. (g) One wire 16.00 sq. mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (A) with medium class Rigid PVC pipe and accessories (a) 2 wire 1.5 sq. mm
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size (A) with medium class Rigid PVC pipe and accessories (b) 2 wire 2.5 sq. mm
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes.(2) 25 mm
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (A) single phase incoming and horizontal single phase outgoing (b) sheet steel double door (IP-43) (ii)6 way
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Cat.III
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 Amp. Cat-III
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete having 3blades with aluminium blades with , canopy & 30 cm. down rod erected with earthing.(Make shall be approved by Engineer in charge))
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without leakage and earthing.
Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC bars up to 50mm length each side and pierced through a 16 Gauge M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with necessary finishing.
Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box.
Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame.200mm with 1350RPM
Supplying & erecting approved make strip light with all necessary equipments complete.
Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cm. Deep in below ground level with plinth of 45 cm x 45 cm (or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in approved manner. ( for 4 & 6 mtr pole)
Providing and erecting street light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. / require size pole top having sufficient fasteners for fixing the brackets and having spread of 1 mtr. length with suitable rise as per site condition & suitable welded stiffener reducer and nipple with check nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of arms. [A] Single Arm bracket 1 Mtr
Supply, Installation, Testing and Comissioning of 4MP Varifocal Lens Dome Type Camera, H.265 4MP IR Turret Dome N/W Camera, Manual Varifocal 2.8-12mm, 50M, Micro SD, DC12V/PoE, IP67/IK10, Basic IVA, 4MP resolution (2560 × 1440), True day/night, Digital WDR, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Built in MIC, Cyber Security, Basic intelligent video analytics, Audio In, NDAA Compliance, UL, CE, FCC Certified (Including Five year free maintenance with guarantee)
Supply, Installation, Testing and Comissioning of 4MP Varifocal Lens Bullet Camera, H.265 4MP IR Bullet N/W Camera, Manual Varifocal 2.8-12mm, 50M, Micro SD, DC12V/PoE, IP67/IK10, Basic IVA, 4MP resolution (2560 × 1440), True day/night, Digital WDR, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Cyber Security, Basic intelligent video analytics, NDAA Compliance, UL, CE, FCC Certified (Including Five year free maintenance with guarantee)
Supply, Installation, Testing and Comissioning of 16 Channel Network Video Recorder (NVR), 1, RJ-45 10/100/1000 Mbps self-adaptive Ethernet interface, Supports H.265+/ H.265/H.264/H.264+ decoding formats, Embedded NVR, 2 HDD Bays, up to 6TB capacity each disk, HDMI, VGA output, 1-ch @ 8 MP / 4- ch @ 1080p, Incoming bandwidth 160Mbps, Outgoing 80 Mbps, CE FCC, BIS, Operating Temp -10 deg to 55 deg C, 2xUSB 2.0 1USB and serial Interface (Including Five year free maintenance with guarantee)
SITC of SCREEN SIZE 80 cm diagonal (32” INCH), RESOLUTION HD (1366*768), USB INPUT (2.0 SUPPORT) 2*Side(USB2.0), HDMI INPUT 3*Side(HDMI 1.4), USB DEVICE SUPPORT USB Supported HDD, HOTEL MODE Yes, Basic, BLUETOOTH Yes (Ver. 4), WIFI TYPE(STANDARD) 802.11a/b/g/n 2.4G 2T2R, Built-in, WIFI BAND TYPE 2.4GHz, OS & VERSION INFO Android 'P' - 9.0, MEMORY FLASH 8GB EMMC, RAM 1.5GB , DDR3 2133 Mhz. (Including Five year free maintenance with guarantee)
SITC of 8 x 10/100/1000BASE-T PoE ports 2 x Gigabit SFP ports Advanced L2 switching and security features L2+ Static Routing Optional “standard mode” or “surveillance mode” management user interface 65W PoE budget (Including Five year free maintenance with guarantee)
Supply, Installation, Testing and commissioning of 4 TB Surveillance Series Hard disk supporting 24X7 operational efficiency
Supply, installation, testing and commissioning of 9 U Rack including necessary power mounting and fan arrangements for mounting CCTV equipments
S K PARMAR
M/S Jai Shri New Chamunda Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .