Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 CrAdmitted-Finance | ₹8.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹9.3 CrAdmitted-Finance | ₹9.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹4.6 CrAdmitted-Finance 5TH FLOOR NEHERU NAGAR WAGLE INDUSTRIAL ESTATE THANE WEST THANE MAHARASHTRA 400604 | THANE | MAHARASHTRA | 400604 | ₹4.6 Cr | L3 | Admitted-Finance |
| 4 | L4₹4.3 CrAdmitted-Finance | ₹4.3 Cr | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Miraj Instrumentation Services I Pvt. Ltd. L3 | Tuaman Engineering Limited L1 | ELMATICS ENGINEERS PVT LTD L4 | Konstelec Engineers Limited L2 |
|---|---|---|---|---|---|---|---|
| 1.00Supply of following items Supply charges including charges for transportation, unloading at site, MTC, fasteners, accessories, material inspection at Vendor work shop including TPI charges , , MOC as per Modulating & ON/OFF Control and Isolation Valves-TP-1ZZZA-IC-SPE-0011 & TP-1ZZZA-IC-SPE-0012; For Hooter, Beacon & FireDetectors refer Specification-TP-1ZZZA-IC-SPE-0024_D1. | |||||||
| 2.00 | SOLENOID VALVES | 5 | Nos. | 1,10,555 ₹5.5 L | 4,627.39 ₹23,136.95 | 7,700 ₹38,500 | 34,345.18 ₹1.7 L |
| 3.00 | AIR FILTER REGULATORS | 5 | Nos. | 11,930 ₹59,650 | 4,627.39 ₹23,136.95 | 5,500 ₹27,500 | 19,884.92 ₹99,424.60 |
| 4.00 | BEACON & HOOTER | 5 | Nos. | 17,799 ₹88,995 | 37,812.42 ₹1.9 L | 10,200 ₹51,000 | 20,101.25 ₹1.0 L |
| 5.00 | TERMINAL BLOCKS | 10 | Nos. | 121 ₹1,210 | 132.21 ₹1,322.10 | 150 ₹1,500 | 1,063.3 ₹10,633 |
| 6.00 | DIN RAIL | 10 | Nos. | 362 ₹3,620 | 1,639.42 ₹16,394.20 | 250 ₹2,500 | 835.33 ₹8,353.30 |
| 7.00 | Hand SWITCH STOP, RESET | 10 | Nos. | 3,169 ₹31,690 | 594.95 ₹5,949.50 | 4,300 ₹43,000 | 7,238.45 ₹72,384.50 |
| 8.00 | Light Interface Unit with Patch Chord - 6 port | 5 | Nos. | 3,681 ₹18,405 | 33,052.82 ₹1.7 L | 12,500 ₹62,500 | 18,836.6 ₹94,183 |
| 9.00 | 8-Port ethernet switch | 5 | Nos. | 78,246 ₹3.9 L | 52,884.51 ₹2.6 L | 54,000 ₹2.7 L | 41,899.78 ₹2.1 L |
| 10.00 | RS-485 to MODBUS TCPIP converter- Industrial Grade of reputed make | 5 | Nos. | 12,636 ₹63,180 | 26,442.25 ₹1.3 L | 19,500 ₹97,500 | 25,126.56 ₹1.3 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹29.9 L
Closing Date
18 Nov 2025, 3:00 pmClosed
Mr.Amit Borkar
thyssenkrupp Uhde India Pvt Ltd Vikhroli Mumbai India
INSTRUMENTATION WORKS FOR GDS UNIT AND PROPYLENE RECOVERY SECTION FOR EPCM1 AT NREP ( Group A)
2025_NRL_875177_1
TK-1ZZZA-MP-RFQ-0192
Open Tender
Miscellaneous Works
540 days
Numaligarh Refinary Limited Assam
As per Tender
9 documents required · 9 mandatory
₹0
₹29.9 L
Yes
ONLINE
16 Jan 2026
30 Aug 2025
19 Nov 2025
30 Aug 2025
18 Nov 2025
29 Sept 2025
30 Aug 2025 - 8 Sept 2025
9 Sept 2025
Supply of following items Supply charges including charges for transportation, unloading at site, MTC, fasteners, accessories, material inspection at Vendor work shop including TPI charges , , MOC as per Modulating & ON/OFF Control and Isolation Valves-TP-1ZZZA-IC-SPE-0011 & TP-1ZZZA-IC-SPE-0012; For Hooter, Beacon & FireDetectors refer Specification-TP-1ZZZA-IC-SPE-0024_D1.
SOLENOID VALVES
AIR FILTER REGULATORS
BEACON & HOOTER
TERMINAL BLOCKS
DIN RAIL
Hand SWITCH STOP, RESET
Light Interface Unit with Patch Chord - 6 port
8-Port ethernet switch
RS-485 to MODBUS TCPIP converter- Industrial Grade of reputed make
Ethernet to FO converter - industrial grade of reputed make
Corrosion probe with Hand held indicator and retractable probe and mandatory spare. (Refer MR document TK-1ZZZA-IC-SPE-0035 for details)
JUNCTION BOXES - SUPPLY
Supply charges including handling, TPI charges, transportation to the installation location, required hardware’s/fasteners, plugging of spare entries, Tagging, box-up, suitable greasing for screws/L key screws, tools & tackles, manpower,scaffolding etc. (MOC of hardware's shall as per tkUIPL -India specification and direction of Engineer-in-Charge.
WEATHERPROOF JUNCTION BOXES
30 Terminals
EX-ROOF/FLAME PROOF JUNCTION BOXES
20 Terminals
12 Terminals
06 Terminals
40 Terminals
EX-PROOF/FLAME PROOF/WEATHER PROOF HAND SWITCHES/PUSH BOTTON - SUPPLY
PUSH BUTTON STATION / CONTROL / LOCAL PANELS
EMERGENCY STOP
VIBRATION RESET/ON-OFF VALVES RESET PB STATION
BEACON TEST AND RESET PB STATION
INSTRUMENT AIR MANIFOLDS- SUPPLY
Supply charges including handling, transportation to the installation location, hardware/fasteners, accessories installation, pneumatic testing, cleaning/flushing, require consumables, tools & tackles, manpower, etc. all complete as per specification all complete as per specification TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation . and direction of Engineer-in-Charge.
TUBE AND TUBE FITTING- SUPPLY
Supply charges including handling, TPI charges, transportation to the working location, fabrication, accessories installation (fittings, valves manifold, etc.), tools & tackles, manpower, scaffolding , Hydro/Pneumatic testing, dressing, clamping, tagging, etc. all complete as per specification TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation
SS316 TUBE SIZE
12mm OD x 1.65mm WT, Seamless, SS316
10mm OD Copper Tube
FITTINGS- SS316
MALE CONNECTORS- SS316 (1/2" NPTM x 1/2" OD)
FEMALE CONNECTOR- SS316 (1/2" NPTF x 1/2" OD)
UNION TEE (1/2" OD x 1/2" OD x 1/2" OD)
TUBE UNION (1/2" OD x 1/2" OD)
TUBE CAP (1/2" OD)
NEEDLE VALVE
END BLIND CAP (NPT MALE)
ADAPTOR/REDUCER
GATE VALVE (1/2" NPTF x 1/2" NPTF)
CONDENSATE POT-SS316 (3" Pot with, 1/2"NPT)
MALE CONNECTORS- SS316 (1/4" NPTM x 12mm OD)
FEMALE CONNECTOR- SS316 (1/4" NPTF x 12mm OD)
END BLIND CAP ( 12mm OD) FOR TUBE
2 VALVE MANIFOLD SS316 (1/2"NPTFx1/2"NPTF)
2 VALVE MANIFOLD SS316 (1/2"NPTFx1/2"NPTM)
CONDENSATE POT-SS316 (3" Pot with, 3/4"NPT)
Instrument Tube support
CABLE GLANDING AND TERMINATION
Supply charges including TPI charges, transportation to working location ,require hardware/fasteners, consumables, installation of hoods & adapters, tagging ,ferruling, lugging, supply of consumables( like lugs, sleeve for shield/drain, sealing compounds etc.) , making suitable holes for cable entries, tools & tackles, manpower, scaffolding etc. all complete as per specification and direction of Engineer-in-Charge. Glanding & termination is included in cable laying cost. Following is applicable if contractor to perform only glanding & termination and cables are layed by others.
SIGNAL,CONTROL,POWER CABLES
1/2" NPT DOUBLE COMPRESSION SS304 with shrouds
1/4" NPT DOUBLE COMPRESSION SS304 with shrouds
1-1/2" NPT DOUBLE COMPRESSION SS304 with shrouds
1-1/4" NPT DOUBLE COMPRESSION SS304 with shrouds
1" NPT DOUBLE COMPRESSION SS304 with shrouds
1/2" NPT BLINF PLUG
1-1/2" NPT BLIND PLUG
CABLE GLANDS 1-1/2" ET, Weatherproof with Checknut (PANEL)
CABLE GLANDS 1" ET, Weatherproof with Checknut (PANEL)
CABLE GLANDS 1-1/4" ET, Weatherproof with Checknut (PANEL)
1 1/2"NPT X 2"NPT ADAPTER DOUBLE COMPRESSION CABLE GLAND
1 1/2"NPT X 1*1/4''NPT (F) NPT Reducer DOUBLE COMPRESSION CABLE GLAND
1 1/2"NPT X 1"NPT ADAPTER DOUBLE COMPRESSION CABLE GLAND
1/2" NPT X 3/4"NPT ADAPTER DOUBLE COMPRESSION CABLE GLAND
ADAPTOR M32 (M) x M40 (F)
3/4" NPT DOUBLE COMPRESSION
FIBER OPTICAL; ARMOURED /UNARMOURED
Scope includes preparation of all fibres and splicing / patching ,Supply of adequate consumables for the execution of the work (such as fibre optic connectors suitable for the application), testing, tools & tackles, manpower, scaffolding etc. all complete as per specification REFER AS TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation and direction of Engineer-in-Charge.
FIBER-OPTIC CABLES- Single Mode , 6 Fibre
CABLE TRAYS/DUCTS SUPPLY & INSTALLATION
Supply charges including transportation to working location, TPI charges , Fabrication, Clamping, accessories installation (including bends, elbows, reducers etc.), Tray identification, painting wherever require, consumables, tools & tackles, manpower, scaffolding etc. all complete as per tkUIPL -INDIA specification and direction of Engineer-in-Charge. TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation
PERFORATED TRAY WITH COVERS ANODISED ALUMINIUM (Upto 300mm Bends shall be site fabricated)
WIDTH 300 MM
WIDTH 150 MM
WIDTH 100 MM
WIDTH 50 MM
CONDUITS :
RIGID HDPE CONDUITS : HDPE conduit shall be as per IS-4984 or as per equivalent IEC code. The outer sheath colour of HDPE conduits shall be orange with black for the fittings throughout the fibre optic cable run. Installation charges including transportation from tkUIPL /Client material store to working location, fabrication like (making threads, bends, etc.), require hardware’s/fasteners (U clamps etc.), clamping/supporting, accessories installation(fittings), consumables, tools & tackles, manpower, scaffolding etc. all complete as per tkUIPL -INDIA specification-REFER AS TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation and direction of Engineer-in-Charge.
25 mm nominal dia
50 mm nominal dia
FLEXIBLE CONDUITS (SS304): Supply and Installation charges including TPI charges, transportation to working location, fabrication like (making threads, bends, etc.), require hardware’s/fasteners (U clamps etc.), clamping/supporting, accessories installation(fittings), consumables, tools & tackles, manpower, scaffolding etc. all complete as per tkUIPL -INDIA specification REFER AS TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation and direction of Engineer-in-Charge.
25 mm nominal dia conduit
50 mm nominal dia conduit
CANOPY /SUNSHADE FRP - SUPPLY
Supply charges including TPI charges ,transportation to working location, supporting wherever require for instruments, JBs , etc. (like integrated inline instruments, close couple mounted instruments, etc.), hardware's/fasteners, consumables etc. Fabrication, installation, tools & tackles, manpower, scaffolding etc. all complete as per tkUIPL -INDIA specification and direction of Engineer-in-Charge.TP-1ZZZA-IC-BOD-0001_D3 Engineering Design Basis for Instrumentation
PREFABRICATED. CANOPIES
SINGLE TRANSMITTER INCLUDING TEMP ELEMENT & GAS/ FIRE DETECTOR
TWO TRANSMITTERS/INSTRUMENTS
SINGLE JUNCTION BOXES
THREE JUNCTION BOXES
FOUR JUNCTION BOXES
HAND SWITCH/PUSH BUTTON
Multiple transmitters/instruments
Two Junction boxes
Six Junction boxes
Eight Junction boxes
Five Junction boxes
SEVEN JUNCTION BOX
STANCHIONS FOR INSTRUMENTS - SUPPLY
Supply charges including TPI charges, transportation to working location, brication, surface cleaning, painting, suitable clamps with pipe line (for close couple hook-ups etc.), hardware's/fasteners, grouting, clamps, consumables, tools & tackles, manpower, scaffolding etc. all complete as per tkUIPL -INDIA specification-REFER AS PER DOCUMENT INSTRUMENT INSTALLATION SKETCHES and direction of Engineer-in-Charge.REFER AS PER DOCUMENT TP-1ZZZA-IC-STD-0001 INSTRUMENT INSTALLATION SKETCHES
FLOOR MOUNTING
PLATFORM MOUNTING
OUTSIDE HAINDRAIL
MULTIPLE TX ON PLATFORM MOUNTING
STRUCTURAL STEEL
Supply charges including TPI charges, transportation , fabrication, installation, surface cleaning, painting , consumables, tools & tackles, manpower, etc. all complete as per tkUIPL -INDIA specification.and direction of Engineer-in-Charge.
STRUCTURAL STEEL
NUT & BOLTS WITH WASHERS, M10x35mm, SS
ANCHOR FASTNER, M10x80mm, MS (CADMIUM)
BEAM CLAMP WITH SS BOLT & NUT , HEIGHT 40mm, MS/SS
PIPE CLASS B,IS=1239 PART-1 , 2", MS(PAINTED)
TYPE "J" HOOK BOLT & NUT , M10x100mm, MS
ANCHOR FASTNER, M10x100mm, MS HD.GALVANISED
ANCHOR FASTNER, M12x100mm, MS (CADMIUM)
STRUT CHANNEL (1-5/8")
MS GI ROD THREADED (1/2")
SQUARE WASHER (1/2")
Item Rate BoQ
BoQ_Ver3.0
Notes- 1. Bid evaluation shall be done on Overall total lowest bidder on landed cost basis as specified in NIT, SPC, ITB & Tender Document. 2. Bidder must quote All of the line items below and Order against any item cannot be further splitted and each line item shall be considered as a non-divisible item. 3.Prices mentioned in Basic Rate is inclusive of all activities like Fabrication, Painting, Testing, TPI, and Transportation etc. to Site as per specifications mentioned in the Tender Document. 4.Correct offer submission is the responsibility of the Bidder and no relief or consideration can be given for errors and omissions. 5.Prices shall be quoted strictly as per the price schedule format made available herein without altering any of the contents of the "price schedule" format. 6.Prices mentioned in Basic Rate is inclusive of all erection & commissioning spares & Special Tools (If Applicable). 7. Manpower Deployment-. The Unit Man Month charges shall include all travel, boarding, lodging, local transport, medical, all insurance including third party, income tax, all taxes & all other incidental charges. (As applicable) 8. Quoted total price shall include cost of any other supplies/work(s) /Services not specifically mentioned in the Bidding Document but necessary for the efficient, trouble free operation of the Plant and to make this package job complete. 9. Bidder to note that, PPLC policy 2020-21 is mandatory for this Tender. Bidder to submit Declaration, Undertaking and requested documents as per ITB-Miscellaneous Policies-PURCHASE PREFERENCE (LINKED WITH LOCAL CONTENT) 2020-21 (PP-LC) 10.Prices for quoted Spare parts for two year operation shall NOT be considered during evaluation. 11. Opening of Price Bid does not mean that Bidder’s offer is Acceptable Techno-Commercially for Not Acceptable Items. Price Bid Evaluation shall be carried out in line with Techno-Commercial Acceptance Report uploaded during Technical Evaluation on CPP Portal. 12.Bidder to note that the position of the bidders indicated in BOQ Comparative Chart in the CPPP is generated automatically by the system immediately after opening priced bid, and the same is not final. Actual position of the bidder will be decided only after scrutiny of the quote(s) in BOQ considering all loading factors as per terms and conditions of the bid. Accordingly, the comparative statement and L1 position published subsequently through an uploaded document should be considered as final.
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE - SUMMARY OF PRICES (INSTALLATION WORKS AT PROPYLENE RECOVERY SECTION UNIT- SP- 2) (DOMESTIC TENDERS - RATES ARE TO BE GIVEN IN RUPEES (INR) ONLY) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
FIELD INSTRUMENT INSTALLATION
Installation charges including handling, shifting from site-store / yard to the installation location, required hardware/fasteners, consumables, tagging, tools & tackles,scaffolding , manpower etc. all complete as per specification and direction of Engineer-in-Charge INCLUDING INSTALLATION OF EXTERNAL SURGE PROTECTOR
MASS FLOWMETERS (REMOTE MOUNTED TRNASMITTERS ONLY)
DP TYPE FLOW TRANSMITTERS
GAUGE PRESSURE TRANSMITTERS
PRESSURE TRANSMITTER REMOTE SEAL PAN CAKE TYPE WITH FLUSHING RING
DP TRANSMITTER REMOTE SEAL PAN CAKE TYPE WITH FLUSHING RING (HP+LP)
DIFFERENTIAL PRESSURE TRANSMITTER
DISPLACER LEVEL TRANSMITTER
TEMPERATURE TX SEPARATELY MOUNTED
LOOP POWER LOCAL INDICATORS
MAGNETIC TYPE LEVEL GAUGE
PRESSURE GUAGES SCREW CONNECTION
PRESSURE GUAGES REMOTE SEAL PAN CAKE TYPE WITH FLUSHING RING
DIFFERENTIAL PRESUSRE GAUGE WITH MANIOLD
RESISTANCE TEMPERATURE DETECTORS WITH THEMOWELL
THERMOCOPLES WITH THEMOWELL
TEMPERATURE GAUGES WITH THERMOWELLS RIGID STEM TYPE
TUNING FORK LEVEL SWITCH
ANNUBARS/PITOT TUBEs (DP TYPE FLOW METER)
Corrosion probes
GAS DETECTORS
Installation charges including handling, shifting from site-store / yard to the installation location, installation of , calibration cylinders, accessories, glanding ,consumables, fasteners, tools & tackles, manpower,scaffolding etc. all complete as per specification and direction of Engineer-in-Charge.
BEACON
HOOTER
LEL DETECTOR
FIRE / FLAME DETECTOR
TOXIC GAS DETECTOR
OPEN PATH DETECTOR
ANALYSERS
Installation charges including handling, shifting from site-store / yard to the installation location, installation of sampling system, probes, calibration cylinders, accessories, heat tracing, insulated tube, glanding ,consumables, fasteners, tools & tackles, manpower,scaffolding etc. all complete as per specification and direction of Engineer-in-Charge.
MOISTURE ANALYSER CABINET
SAMPLE TUBE
ETHANE ANALYSER
BUTANE ANALYSER
PROPENE ANALYSER
PROPYLENE ANALYSER
Installation of following items Installation charges including charges for transportation, unloading at site, MTC, fasteners, accessories, material inspection at Vendor work shop including TPI charges , MOC as per Modulating & ON/OFF Control and Isolation Valves TP-1ZZZA-IC-SPE-0011 & TP-1ZZZA-IC-SPE-0012; For Hooter, Beacon & Fire Detectors refer Specification-TP-1ZZZA-IC-SPE-0024_D1.
SOLENOID VALVES
AIR FILTER REGULATORS
BEACON & HOOTER
TERMINAL BLOCKS
DIN RAIL
Hand SWITCH STOP, RESET
Light Interface Unit with Patch Chord - 6 port
8-Port ethernet switch
RS-485 to MODBUS TCPIP converter- Industrial Grade of reputed make
Ethernet to FO converter - industrial grade of reputed make
FIRE PROOF JACKET FOR ACTUATORS OF VALVES > 20"
FIRE PROOF JACKET FOR ACTUATORS OF VALVES 10" to 20"
FIRE PROOF JACKET FOR ACTUATORS and VALVE BODY <10"
FIRE PROOF JACKET FOR VALVE BODY 1" to 8"
LCP/DCS/PLC CABINETS/ANALYSER SHELTERS/MONITORS/PRINTORS/FURNITURES
Installation charges including handling, shifting from site-store / yard to the installation location, erection, alignment, required hardware’s/fasteners, plugging of spare entries, tools & tackles, manpower, lifting equipment's ,trolley,scaffolding etc.MOC of hardware's shall as per tkUIPL -India specification ). All complete as per specification and direction of Engineer-in-Charge.
LCP/DCS/PLC CABINETS/MONITORS/PRINTORS/FURNITURES
PANEL: 1200W X 800D X 2100H
PANEL: 800W X 800D X 2100H
LCP:1200 W X 800 D x 2100 H (1P25-KA-3181)
LCP:1200 W X 1000 D x 2110 H (1P25-BL-8281)
ANALYSER PC-1
JUNCTION BOXES - INSTALLATION
Installation charges including handling, TPI charges, transportation to the installation location, required hardware’s/fasteners, plugging of spare entries, Tagging, box-up, suitable greasing for screws/L key screws, tools & tackles, manpower,scaffolding etc. (MOC of hardware's shall as per tkUIPL -India specification and direction of Engineer-in-Charge.
WEATHERPROOF JUNCTION BOXES
30 Terminals
EX-ROOF/FLAME PROOF JUNCTION BOXES
20 Terminals
12 Terminals
06 Terminals
40 Terminals
EX-PROOF/FLAME PROOF/WEATHER PROOF HAND SWITCHES/PUSH BOTTON - SUPPLY AND INSTALLATION
PUSH BUTTON STATION / CONTROL / LOCAL PANELS
EMERGENCY STOP
VIBRATION RESET/ON-OFF VALVES RESET PB STATION
BEACON TEST AND RESET PB STATION
SUPERVISION OF INLINE INSTRUMENTS
Suppervision,of Inline instrument by Mechanical Cpntractor, all complete as per specification and direction of Engineer-in-Charge INCLUDING INSTALLATION OF EXTERNAL SURGE PROTECTOR
INLINE INSTRUMENT
CONTROL VALVE
CORIOLIS MASS FLOWMETER
ON-OFF VALVE
ANNUBARS/PITOT TUBEs (DP TYPE FLOW METER)
Self Actuated Pressure Control Valve
VENTURI
MOV ON-OF VALVE (GATE)
MOV ON-OF VALVE (BUTTERFLY)
HOOK-UPS (MANIFOLDS)-CS/SS
Installation charges including handling, shifting from site-store / yard to the installation location,INSTALLATION OF TRANSMITTER, Co-ordination with MQ contractor for welding to piping, consumables, tools & tackles, manpower, scaffolding etc. all complete as per specification and direction of Engineer-in-Charge. REFER PRE-FABRICATION HOOK-UP SPECIFICATIONS.
PRE-FABRICATED HOOK-UP
FLOW TRANSMITTER (DIFF.PRESSURE TYPE) (HOOKUP WITH CANOPY)
PRESSURE GAUGES
PRESSURE TRANSMITTER (HOOKUP WITH CANOPY)
FABRICATED HOOK-UP AT SITE: Installation charges including handling, shifting from site-store / yard to the installation location, surface cleaning, painting, fabrication, installation, accessories installation (fittings, valves manifold, etc.), welding, radiography, Hydro/Pneumatic testing, clamping, tagging, consumables, tools & tackles, manpower, scaffolding etc. all complete as per specification and direction of Engineer-in-Charge. REFER HOOK-UP DOCUMENT FOR BOM & MOC.TK-1P25A-IC-HUP-0003_N1 & TK-1P26A-IC-HUP-0003_N1
DIFFERENTIAL PRESSURE TRANSMITTERS GAS SERVICE
DIFFERENTIAL PRESSURE TRANSMITTERS LIQUID SERVICE
D/P FLOW TRANSMITTER - ORIFICE LIQUID SERVICE (BELOW PIPE)
D/P FLOW TRANSMITTER - ORIFICE GAS SERVICE (ABOVE PIPE)
D/P FLOW TRANSMITTER - ORIFICE STEAM SERVICE
PRESSURE GAUGE REMOTE MOUNTED -GAS SERVICE
PRESSURE GAUGE REMOTE MOUNTED -LIQUID SERVICE
PRESSURE GAUGE REMOTE MOUNTED -STEAM SERVICE
PRESSURE TRANSMITTER - LIQUID SERVICE
PRESSURE TRANSMITTER - GAS SERVICE
PRESSURE TRANSMITTER - STEAM SERVICE
DIFFERENTIAL PRESSURE GAUGE
D/P FLOW TX. DIAPHRAGM SEAL - ORIFICE GAS SERVICE (BELOW PIPE)
PRESSURE GAUGE REMOTE DIAPHRAGM SEAL
PRESSURE TX REMOTE DIA.SEAL
INSTRUMENT AIR MANIFOLDS- INSTALLATION
Installation charges including handling, transportation to the installation location, hardware/fasteners, accessories installation, pneumatic testing, cleaning/flushing, require consumables, tools & tackles, manpower, etc. all complete as per specification and direction of Engineer-in-Charge.
TUBE AND TUBE FITTING- INSTALLATION
Installation charges including handling, TPI charges, transportation to the working location, fabrication, accessories installation (fittings, valves manifold, etc.), tools & tackles, manpower, scaffolding , Hydro/Pneumatic testing, dressing, clamping, tagging, etc. all complete as per tkUIPL-INDIA specification-
SS316 TUBE SIZE
12mm OD x 1.65mm WT, Seamless, SS316
10mm OD pvc COATED Copper Tube
FITTINGS- SS316
MALE CONNECTORS- SS316 (1/2" NPTM x 1/2" OD)
MALE CONNECTORS- SS316 (1/4" NPTM x 12mm OD)
FEMALE CONNECTOR- SS316 (1/2" NPTF x 1/2" OD)
UNION TEE (1/2" OD x 1/2" OD x 1/2" OD)
TUBE UNION (1/2" OD x 1/2" OD)
TUBE CAP (1/2" OD)
NEEDLE VALVE
GATE VALVE (1/2" NPTF x 1/2" NPTF)
END BLIND CAP (NPT MALE)
ADAPTOR/REDUCER
CONDENSATE POT-SS316 (3" Pot with, 1/2"NPT)
2 VALVE MANIFOLD SS316 (1/2"NPTFx1/2"NPTF)
MALE CONNECTOR, 1/2"OD X 3/4"NPTM, SS316
MALE CONNECTOR, 1/2"OD X 1"NPTM, SS316
Instrument Tube support
MALE CONNECTOR, 1/2"OD X 1/4"(G), SS316,TYPE, WITH DOUBLE FERRULES,
MALE CONNECTOR, 1/2"OD X 1/8"(G), SS316,TYPE, WITH DOUBLE FERRULES,
C series check valve 1/2''OD,crack pressure,1/3PSIG seal,MOC-SS 316.
Female Connector 3/4" NPTF X 3/4" OD,SS316
CONNECTOR - 1/2" X 3/4" - BSP (M) X OD - 6000 # - SS316/SS316L
CONNECTOR - 3/4" X 3/4" - BSP (M) X OD - 3000 # - SS316/SS316L
Male connector double compression 1/2"BSP(M) x 1/2 " OD,SS316
FEMALE CONNECTOR- SS316 (1/4" NPTF x 12mm OD)
2 VALVE MANIFOLD SS316 (1/2"NPTFx1/2"NPTM)
TUBE UNION-SS316 (6mm OD)
END BLIND CAP ( 12mm OD) FOR TUBE
INSTRUMENT CABLE LAYING
Installation charges including handling, shifting from site-store / yard to the installation location, meggering, continuity test, Cable glanding, both side termination, cable dressing, clamping, cable tagging, ferruling, supply of consumables( like lugs, sleeve for shield/drain, sealing compounds etc.) hardware's/fasteners for clamping/dressing, making holes for cable gland/cable entries ( JBs, Panels ,etc.), tools & tackles, manpower, scaffolding etc. all complete as per specification and direction of Engineer-in-Charge.
SIGNAL CABLES ,MULTISTRANDED,ARMOURED
1 PAIR X 1.5 mm2 Screened
1 PAIR X 2.5 mm2 Screened
2 PAIR X 1.5 mm2 Screened
6 PAIR X 1.5 mm2 Screened
6 PAIR X 2.5 mm2 Screened
12 PAIR X 1.5 mm2 Screened
12 PAIR X 2.5 mm2 Screened
1 TRAID X 1.5 mm2 Screened
8 TRAID X 1.5 mm2 Screened
SIGNAL CABLES , MULTISTRANDED,ARMOURED, FIRE RESISTANCE
1 PAIR X 1.5 mm2 Screened
1 PAIR X 2.5 mm2 Screened
2 PAIR X 1.5 mm2 Screened
6 PAIR X 1.5 mm2 Screened
6 PAIR X 2.5 mm2 Screened
12 PAIR X 1.5 mm2 Screened
12 PAIR X 2.5 mm2 Screened
1 TRAID X 1.5 mm2 Screened
8 TRAID X 1.5 mm2 Screened
FIBEROPTICAL; ARMOURED /UNARMOURED
FIBER-OPTIC CABLES- Single Mode , 6 Fibre
POWER CABLES, MULTISTRANDED/SINGLE, ARMOURED
3Cx2.5 SQMM
EARTHING CABLES; UNARMOURED
1 CORE X 6 mm2
CABLE GLANDING AND TERMINATION
Installation charges including TPI charges, transportation to working location ,require hardware/fasteners, consumables, installation of hoods & adapters, tagging ,ferruling, lugging, supply of consumables( like lugs, sleeve for shield/drain, sealing compounds etc.) , making suitable holes for cable entries, tools & tackles, manpower, scaffolding etc. all complete as per specification and direction of Engineer-in-Charge. Glanding & termination is included in cable laying cost. Following is applicable if contractor to perform only glanding & termination and cables are layed by others.
SIGNAL,CONTROL,POWER CABLES
1/2" NPT DOUBLE COMPRESSION SS304 with shrouds
1/4" NPT DOUBLE COMPRESSION SS304 with shrouds
1-1/2" NPT DOUBLE COMPRESSION SS304 with shrouds
1-1/4" NPT DOUBLE COMPRESSION SS304 with shrouds
1" NPT DOUBLE COMPRESSION SS304 with shrouds
1/2" NPT BLINF PLUG
1-1/2" NPT BLIND PLUG
1 1/4" NPT PLUG
CABLE GLANDS 1-1/2" ET, Weatherproof with Checknut (PANEL)
CABLE GLANDS 1" ET, Weatherproof with Checknut (PANEL)
CABLE GLANDS 1-1/4" ET, Weatherproof with Checknut (PANEL)
1 1/2"NPT X 1*1/4''NPT (F) NPT Reducer DOUBLE COMPRESSION CABLE GLAND
1/2" NPT X 3/4"NPT ADAPTER DOUBLE COMPRESSION CABLE GLAND
ADAPTOR M32 (M) x M40 (F)
3/4" NPT DOUBLE COMPRESSION
1 1/2"NPT X 1"NPT ADAPTER DOUBLE COMPRESSION CABLE GLAND
1 1/2"NPT X 2"NPT ADAPTER DOUBLE COMPRESSION CABLE GLAND
FIBER OPTICAL; ARMOURED /UNARMOURED
Scope includes preparation of all fibres and splicing / patching ,Supply of adequate consumables for the execution of the work (such as fibre optic connectors suitable for the application), testing, tools & tackles, manpower, scaffolding etc. all complete as per specification and direction of Engineer-in-Charge.
FIBER-OPTIC CABLES- Single Mode , 6 Fibre
CABLE TRAYS/DUCTS INSTALLATION
Installation charges including transportation to working location, TPI charges , Fabrication, Clamping, accessories installation (including bends, elbows, reducers etc.), Tray identification, painting wherever require, consumables, tools & tackles, manpower, scaffolding etc. all complete as per REFER AS TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation and direction of Engineer-in-Charge.
PERFORATED TRAY WITH COVERS ANODISED ALUMINIUM
WIDTH 300 MM
WIDTH 150 MM
WIDTH 100 MM
WIDTH 50 MM
CONDUITS :
RIGID HDPE CONDUITS : HDPE conduit shall be as per IS-4984 or as per equivalent IEC code. The outer sheath colour of HDPE conduits shall be orange with black for the fittings throughout the fibre optic cable run. Installation charges including transportation from tkUIPL/Client material store to working location, fabrication like (making threads, bends, etc.), require hardware’s/fasteners (U clamps etc.), clamping/supporting, accessories installation(fittings), consumables, tools & tackles, manpower, scaffolding etc. all complete as per TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation and direction of Engineer-in-Charge.
25 mm nominal dia
50 mm nominal dia
FLEXIBLE CONDUITS (SS304): Supply and Installation charges including TPI charges, transportation to working location, fabrication like (making threads, bends, etc.), require hardware’s/fasteners (U clamps etc.), clamping/supporting, accessories installation(fittings), consumables, tools & tackles, manpower, scaffolding etc. all complete as per REFER AS TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation-and direction of Engineer-in-Charge.
50 mm nominal dia conduit
25 mm nominal dia conduit
CANOPY /SUNSHADE FRP - INSTALLATION
Installation charges including TPI charges ,transportation to working location, supporting wherever require for instruments, JBs , etc. (like integrated inline instruments, close couple mounted instruments, etc.), hardware's/fasteners, consumables etc. Fabrication, installation, tools & tackles, manpower, scaffolding etc. all complete as per TP-1ZZZA-IC-BOD-0001_D3 Engineering Design Basis for Instrumentation and direction of Engineer-in-Charge.
PREFABRICATED. CANOPIES
SINGLE TRANSMITTER/INSTRUMENT
TWO TRANSMITTERS/INSTRUMENTS
SINGLE JUNCTION BOXES
THREE JUNCTION BOXES
FOUR JUNCTION BOXES
HAND SWITCH/PUSH BUTTON
MULTIPLE TRANSMITTERS/INSTRUMENTS
TWO JUNCTION BOXES
SIX JUNCTION BOXES
EIGHT JUNCTION BOXES
FIVE JUNCTION BOXES
SEVEN JUNCTION BOX
STANCHIONS FOR INSTRUMENTS - INSTALLATION
Installation charges including TPI charges, transportation to working location, brication, surface cleaning, painting, suitable clamps with pipe line (for close couple hook-ups etc.), hardware's/fasteners, grouting, clamps, consumables, tools & tackles, manpower, scaffolding etc. all complete as per tkUIPL-INDIA specification-REFER AS PER DOCUMENT 25284124-8551-65-000-0004 INSTRUMENT INSTALLATION SKETCHES and direction of Engineer-in-Charge.
FLOOR MOUNTING
PLATFORM MOUNTING
OUTSIDE HAINDRAIL
MULTIPLE TX ON PLATFORM MOUNTING
STRUCTURAL STEEL
Installation charges including TPI charges, transportation , fabrication, installation, surface cleaning, painting , consumables, tools & tackles, manpower, etc. all complete as per tkUIPL-INDIA specification.and direction of Engineer-in-Charge.
STRUCTURAL STEEL
NUT & BOLTS WITH WASHERS, M10x35mm, SS
ANCHOR FASTNER, M10x80mm, MS (CADMIUM)
BEAM CLAMP WITH SS BOLT & NUT , HEIGHT 40mm, MS/SS
PIPE CLASS B,IS=1239 PART-1 , 2", MS(PAINTED)
COVER PLATE FOR 2"PIPE , 6THK., MS(PAINTED)
TYPE "J" HOOK BOLT & NUT , M10x100mm, MS
ANCHOR FASTNER, M10x100mm, MS HD.GALVANISED
ANCHOR FASTNER, M12x100mm, MS (CADMIUM)
STRUT CHANNEL (1-5/8")
ROD THREADED (1/2")
SQUARE WASHER (1/2")
FIRE PROOFING FOR CABLE DUCT,TRAY,ANGLE TRAY,ETC.- INSTALLATION
Installation charges including TPI charges, transportation to working location, installation of Mattresses, Cladding, SS Clamps, all fittings, accessories, tools & tackles, manpower, scaffolding etc. all complete as per tkUIPL-INDIA specificationand direction of Engineer-in-Charge.REFER AS TP-1ZZZA-IC-SPE-0033_D1 Specification for Instrument Installation
PERFORATED TRAY WITH COVERS ANODISED ALUMINIUM
WIDTH 300 MM
INSTRUMENT CALIBRATION
Calibration charges including handling, shifting from site-store / yard to the installation location, restore to safe place after calibration, removable and reinstallation from/to package units, if required, require tools & tackles, manpower, calibrators, calibration laboratory, changing range / engg. unit etc. as per data sheet, trouble shooting, zero elevation & subtraction, preparation of reports, hardware/fasteners, consumables, Labelling (with range, date, tag), etc. all complete as per specification and direction of Engineer-in-Charge.
TRANSMITTERS (PNEUMATIC + ELECTRONIC)
MAGNETIC FLOW METERS (REMOTE MOUNTED TRANSMITTERS ONLY)
MASS FLOWMETERS (REMOTE MOUNTED TRNASMITTERS ONLY)
ANNUBARS/PITOT TUBEs (DP TYPE FLOW METER)
DP TYPE FLOW TRANSMITTERS
GAUGE PRESSURE TRANSMITTERS
PRESSURE TRANSMITTER REMOTE SEAL PAN CAKE TYPE WITH FLUSHING RING
DP TRANSMITTER REMOTE SEAL PAN CAKE TYPE WITH FLUSHING RING (HP+LP)
DIFFERENTIAL PRESSURE TRANSMITTER
DISPLACER LEVEL TRANSMITTER
TEMPERATURE TX SEPARATELY MOUNTED
LOOP POWER LOCAL INDICATORS
TUNING FORK LEVEL SWITCH
ANALYSERS
MOISTURE ANALYSER
ETHANE ANALYSER
BUTANE ANALYSER
PROPENE ANALYSER
PROPYLENE ANALYSER
TEMPERATURE ELEMENTS AND THERMOWELLS
RESISTANCE TEMPERATURE DETECTORS WITH THEMOWELL
THERMOCOPLES WITH THEMOWELL
TEMPERATURE GAUGES WITH THERMOWELLS
RIGID STEM TYPE
LEVEL GAUGE
MAGNETIC TYPE LEVEL GAUGE
PRESSURE GAUGES
SCREW CONNECTION
FLANGED WITH FLUSHING RING
PRESSURE SAFETY VALVE
STROKE CHECKING/CALIBRATION FOR CONTROL VALVES AND ON-OFF VALVES
(Stroke checking/Calibration charges including adjustment of positioners w.r.t. mA, feed backs (limit switches), feed back transmitters (positioner transmitters), seat leak test as per project requirement, oil free instrument air subject to it not available in the plant, tools & tackles, manpower, calibrators, test benches, hardwares, consumables, Labelling (with range, date, tag), ensure flow direction of installed valves if doing on line calibration/stroke checking, etc. all complete as per specification and direction of Engineer-in-Charge. Control/ on-off valves with mechanical stopper shall be checked for proper stopper adjustment as required for the process before installing on line.
CONTROL VALVES WITH ELECTRO PNEUMATIC POSITIONERS (SMART POSITIONER)
ON-OFF VALVE WITH SOV AND TWO FEED BACK
MOV WITH CONTROL & ON-OFF
LOOP CHECKING
Loop checking charges including consumables, tools-tackles, continuity test (cold loop) of each cable if its not done after cable laying, ensure flow direction of in line instruments (like orifice type flow annubars/venturi, magnetic, mass, vortex flow meter, rota meter, Control valves, ON-OFF valves, etc.), trouble shooting, tools & tackles, manpower, calibration if require etc. all complete as per specification and direction of Engineer-in-Charge.
LOOP CHECKING FOR ANALOG AND DIGITAL
ANALOG INPUT
ANALOG OUTPUT
DIGITAL INPUT
DIGITAL OUTPUT
ASSISTANCE FOR EXECUTION OF WORK (SKILLED / UNSKILLED).
Note: These rates for man power are applicable only after total completion of Instrumentation Installation & Instrumentation Commissioning activities.
INSTRUMENT TECHNICIAN
ELECTRICIAN
FITTER
WELDER
HELPER
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.78 MB
BOQ_919974.xls
BOQ • 0.52 MB
Part_II_Group_A_Section5.rar
Tender Documents • 9.67 MB
Part_I.rar
Tender Documents • 36.70 MB
Part_II_Group_A_Section1.rar
Tender Documents • 34.38 MB
Part_II_Group_A_Section2.rar
Tender Documents • 11.33 MB
Part_II_Group_A_Section4.rar
Tender Documents • 9.96 MB
Part_II_Group_A_Section6.rar
Tender Documents • 7.87 MB
Part_II_Group_A_Section7.rar
Tender Documents • 10.22 MB
Part_III_Group_A.rar
Tender Documents • 0.63 MB
Part_II_Group_A_Section3.rar
Tender Documents • 9.96 MB
Download all tender documents and submit your bid