Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L1 | Accepted-AOC Being the 1st lowest | |
| 2 | L2₹47.8 L+₹98,199 (2.10%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹48.6 L+₹1.8 L (3.92%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹49.0 L+₹2.2 L (4.65%)Rejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹50.7 L+₹3.9 L (8.30%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
28 Nov 2024, 6:00 pmClosed
CWE Karanja
CWE Karanja, Naval Station Karanja, Uran, Raigad - 400704
REPAIR/REPLACEMENT OF LIGHT FITTINGS WITH ENERGY SAVING LED LIGHT FITTINGS/FIXTURE, BULK HEAD, DECORATIVE LIGHTS AND ALLIED SERVICES AT NAVAL STATION KARANJA
2024_MES_682494_1
84370-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Station Karanja
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE(NW) Karanja
₹98,000
14 Jan 2025
5 Nov 2024
30 Nov 2024
5 Nov 2024
28 Nov 2024
21 Nov 2024
Amount
Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit / PVC conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, complete all as specified and directed by Engr-in-Charge.
Material and Labour for concealed point wiring with 1.5 sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked, PVC insulated, unsheathed cable (with approved colour code) FRLSH cable in CONCEALED PVC, ISI marked including all accessories as approved by Engr-in-Charge, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continuous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth Gl/MS/ pressed steel terminal box to be concealed in wall, duly painted including laminated hylam/masonite sheet cover thickness 3mm for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer, complete all as specified and directed by Engr-in-Charge for the following :- Note:- Wiring to be done as per approved colour code,
One light /fan/ call bell point controlled by one switch
One 5 pin socket outlet 5 Amps on independent board
One 5 pin socket outlet 5 Amps on same board
One light point controlled by two 2-way switches SP, 5 Amp, 240 Volts
All as per item No 2.00 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 1.5 Sqmm multi standard insulated unsheathed copper wire for continuous earth on independent board, complete all as specified and directed by Engr-in-Charge.
Material and Labour for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in PVC casing & caping of 25 mm wide, with double locking type, ISI marked including all accessories casing caping as approved by Engr-in-Charge, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire, ISI marked of green colour for continuous earth, including sunken box made out of suitable thickness and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted including 3mm hylam /masonite sheet cover, for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer, complete all as specified and directed by Engr-in-Charge, for One light point or one fan point controlled by one switch. Note : Wiring to be done as per approved colour code.
Ditto, all as per item No 4.00 here-in-before but for One light point controlled by two 2-way switches SP, 5 Amp, 240 Volts
Ditto, all as per item No 4.00 here-in-before but for one 5 amp socket point on same board
Ditto, all as per item No 4.00 here-in-before but for one 5 amp multi socket on independent board
Ditto, all as per item No 4.00 here-in-before, but using 2.5 sqmm ( nominal area) multistranded FRLSH copper conductor cable/wire & 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity ( green colour) FRLSH for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed by Engr-in-Charge.
Ditto, all as per item No 4.00 here-in-before, but using 4 sqmm (nominal area) multistranded copper conductor cable/wire FRLSH for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Point wiring with PVC insulated unsheathed electric cable 1100 volts grade, single core, FRLSH cable having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area, ISI marked, drawn in existing concealed / surface conduit with 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor FRLSH cable, ISI marked as continuous earth conductor connected to earth dolly by providing suitable lugs including 3.0 mm new laminated hylam sheet /masonite sheet cover of min thick , ISI marked of Make" Hylem" of suitable sizes to be fixed/ mounting on existing MS/ GI sunken boxes for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer, complete all as specified and directed by Engr-in-Charge, for one light / bell point controlled by one switch. Note : Wiring to be done as per approved colour code.
Ditto, all as per item No 10.00 here-in-before but for One fan/exhaust fan point controlled by one switch
Ditto, all as per item No 10.00 here-in-before but for One 5 pin socket outlet 5 Amps on same board
Ditto, all as per item No 10.00 here-in-before but for One 5 pin socket outlet 5 Amps on independent board
Ditto, all as per item No 10.00 here-in-before but for One light point controlled by 2-way switches SP, 5 Amp, 240 Volts
Ditto, all as per item No 10.00 here-in-before but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continuous earth on independent board.
Supply and Fix switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge. Note : This item is also used as in repair of existing 6 Amp switch.
Supply and Fix Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge. Note : This item is also used as in repair of existing 6 Amp switch socket outlet.
Supply and Fix Socket outlet 2 in 1, 3 pin, 6 Amp flush type (ISI marked) complete all as specified and directed by Engineer-in-Charge. Note : This item is also used as in repair of existing 6 Amp socket outlet.
Supply and Fix Switch bell push flush type 5 Amp (ISI marked) all as per complete all as specified and directed Engineer-in-Charge. Note : This item is also used as in repair of existing 5 Amp switch bell.
Supply and Fix Switch socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix Switch flush button, single pole two way, 6 Amp (ISI marked) complete all as specified and directed by Engineer-in-Charge. Note : This item is also used as in repair of existing 6 Amp two way switch.
Supply and Fix Socket type EME fan 5 step regulator for ceiling fan of suitable size, complete all as specified and directed by Engineer-in-Charge. Note : This item is also used as in repair of existing fan regulator.
Supply and Fix Lamp holder/angle holder insulated body with black/white plate for batten fittings, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular step type fan regulator ISI 120W, AC, 50 Hz marked, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular switch 1 module 6 amp one way, ISI marked, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular switch 1 module 16 amp one way, ISI marked, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular socket 2 module universal type 5/6 amp one way, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular socket 2 module universal type 15/16 amp one way, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular bell push 6A, 1 module, complete all as specified and directed by Engr-in-Charge.
Supply and Fix Bell buzzer, ding dong AC, 230V, 50 Hz, single pole, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular cover plates with frame up 1 /2 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring.
Supply and fix modular cover plates with frame up 3 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular cover plates with frame up 4 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular cover plates with frame up 6 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular cover plates with frame 8 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular cover plates with frame 12 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes which is catered for new point wiring, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular metal flush box as per site requirements 1/2 modules, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular metal flush box as per site requirements 4 modules, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular metal flush box as per site requirements 6 modules, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular metal flush box as per site requirements 8 modules, complete all as specified and directed by Engr-in-Charge.
Supply and fix modular metal flush box as per site requirements 12 modules, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surface/recessed, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surface/recessed, including taking down complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 25mm dia/casing capping, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surface/recessed, including taking down complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly, including taking down, all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly, including taking down, all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 20mm dia/casing capping , ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly in surface/recessed, complete all as specified and directed by Engr-in-Charge.
Material and Labour for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5 Sqmm (Green colour) as continuous earth conductor cable connected to earth dolly including taking down, complete all as specified and directed by Engr-in-Charge.
Material and Labour for cutting of wall/ceiling/column for laying submain of any size including plastering ,white wash, complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED building security light fitting with suitable size bracket/angle with three core flexible wire to fit security light of 45 W, IP 66 protection, LED 220V, AC, 50Hz including GI Bracket , surge protection, high power factor etc, complete all as specified and directed by Engr-in-Charge.
Supply and fix LED batten with 20/22W LED tube light (4") , 220V, AC, 50 Hz in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc, surge protection, high power factor, Surface and wall mounted LED batten, Engineering plastic batten with accessories, complete all as specified and directed by Engr-in-Charge.
Supply and fix LED batten with 24/26W LED tube light (4") , 220V,AC ,50Hz in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts, 200 Amps rated bus bar 12 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts, 200 Amps rated bus bar 8 way double door open able, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts, 200 Amps rated bus bar 4 way, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts, 200 Amps rated bus bar 2 way, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB VTPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way, including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix double door MCB TPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way ,including taking out old unserviceable MCB DB any size/type, complete all as specified and directed by Engr-in-Charge.
Supply and Fix 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) , complete all as specified and directed by Engr-in-Charge.
Supply and Fix 32 AMP MCB DP 240 V 10 KA (C-Series), complete all as specified and directed by Engr-in-Charge.
Supply and fix LED recess/surface mounted 2"x2" luminaire 36/40W fitting, 220V, AC, 50 Hz, surge protection, high power factor complete all as specified and directed by Engr-in-charge.
Supply and fix LED Bulk head fittings 9/10W , 220V, AC, 50Hz luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete with all accessories complete all as specified and directed by Engr-in-charge.
Supply and Fix LED tube rod 20 watt, 220V, 50Hz, AC change with existing any tube rod , complete all as specified and directed by Engr-in-Charge.
Supply and Fixix Batten MS suitable for 18/22/24W LED rod with accessories including suitable 1.5 sqmm 2 core wire for connecting with ceiling rose, complete all as specified and directed by Engr-in-Charge.
Supply and fix LED batten 10W, 2 feet with LED tube light, 220V, 50Hz, AC in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc as directed and specified by Engr-in-charge.
Supply and Fix in repairs MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Material and Labour for daily complaint checking & repairing of DBs/meter panel board/circuits/submain wiring/switches/sockets etc and other connected work including rectification of faults, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repairs MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Taking out cover plate of bus conductor duct of multi-storeyed building, inspection cleaning, servicing including replacement of rusted nuts bolts, insulators etc ,cutting of damage end of outgoing cables and reconnection using proper size of cable lugs and preparation of old painted surface by scrapping and brooming down and material and labour for two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engr-in-Charge.
Supply and fix three pin top of capacity 15 amp, AC, 220V, complete all as specified and directed by Engr-in-Charge.
Supply and fix PCRD plug of capacity 15 amp, AC, 220V, complete all as specified and directed by Engr-in-Charge.
Supply and fix epoxy coated connector of capacity 100A post type for bus bar trunking system complete all as specified and directed by Engr-in-charge.
Taking out two wire from meter / bus bar / MCB SPN / SP with keeping in view safety and replaced with 2 runs of 6 sqmm wire of meter with suitable size of cable lugs both end and reconnection with meter and bus bar/MCB SPN/SP, complete all as specified and directed by Engr-in-Charge. Note : Rate of lugs will deemed to be included in quoted rate by the contractor.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size 10x10cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size 15x7.5cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size 20x15cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair/replacement of old existing sunken/terminal box of size 20x25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls, complete all as specified and directed by Engr-in-Charge.
Supply and Fix emergency bulb LED 10W, 230V, 50Hz, with 4 hour backup, complete all as specified and directed by Engr-in-Charge.
Supply and fix round/square type, recessed /surface 12W/14W warm /white LED downlight dimmable with high lumen 230V, compatible with Legrand Dimmer as per sample as specified & directed by Engr-in-charge.
Supply and Fix RCCBs 63 Amps double pole 100mA breaking capacity, complete all as specified and directed by Engr-in-Charge.
Supply and Fix RCCBs 40 Amps double pole 100mA breaking capacity, complete all as specified and directed by Engr-in-Charge.
Supply and fix decorative light suitable for holder B-22/E-27, 220V, 50 Hz, AC including flexible wire and connected accessories, complete all as specified and directed by Engr-in-Charge.
Material and Labour for taking out and refixing of tube light, mirror light / any type light etc after cleaning and any type rectifying defects, complete all as specified and directed by Engr-in-Charge.
Supply and fix LED batten with 20W LED tube light (four feet) with sensor in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and fix LED batten with 9/10 W LED tube light two feet mirror type with sensor in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and fix LED batten with 20W LED tube light (four feet) with inverter type with 2 hours backup in wall/surface connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and fix LED bulb of 9/10 watt , 220V, AC, 50 Hz, complete all as specified and directed by Engr-in-Charge.
Material and Labour for servicing and cleaning of geyser of any capacity including taking out from existing position and refixing, complete all as specified and directed by Engr-in-Charge.
Material and Labour for checking ceiling fan of size 1200/1400mm and change defective part cotter pin/ nut bolt etc including taking down and refixing, complete all as specified and directed by Engr-in-Charge.
Supply and fix fan rod of size 1/1.5 feet suitable for mounting ceiling fan of size 1200/1400 mm, complete all as specified and directed by Engr-in-Charge.
Supply and fix capacitor of 2.5 mfd, complete all as specified and directed by Engr-in-Charge.
Supply and fix capacitor of 4.0 mfd, complete all as specified and directed by Engr-in-Charge.
Material and Labour copper Rewinding of ceiling fan 1200/1400mm, complete all as specified and directed by Engr-in-Charge.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store/ take in schedule of credit,, complete all as specified and directed by Engr-in-Charge.
Supply and fix LED high bay light of 100Watt including flexible wire and all connected accessories including taking down, complete all as specified and directed by Engr-in-Charge.
Supply and fix LED batten with 20/22W LED tube light 4 FEET box type with hanging arrangement in wall/surface/ceiling connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and fix LED batten with 36/40W LED tube light 6/8 FEET box type with hanging arrangement in wall/surface/ceiling connecting with all required accessories like PVC box base, flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified by Engr-in-charge.
Supply and fix in repair flame proof LED well glass hanging type 45/40W fitting on existing light point with suitable hanging arrangements one light control with one MCB SP, complete all as specified and directed by Engr-in-Charge. Note: The rate includes taking down old light fitting and providing suitable necessary ladders /equipments for any height to taking down the items.
Supply and fix in repair flame proof LED well glass hanging type 60/70w fitting on existing light point with suitable hanging arrangements one light control with one MCB SP, complete all as specified and directed by Engr-in-Charge. Note: The rate includes taking down old light fitting and providing suitable necessary ladders /equipments for any height to taking down the items.
Supply and fix in repair flame proof LED well glass hanging type 100w fitting on existing light point with suitable hanging arrangements one light control with one MCB SP, complete all as specified and directed by Engr-in-Charge. Note: The rates includes taking down old light fitting and providing suitable necessary ladders /equipments for any height to taking down the items.
Material and Labour for flexible wire for connection fan/light/etc of size 1 sqmm x 2 core including taking down old wire, complete all as specified and directed by Engr-in-Charge.
Supply & fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts of the following sizes including taking out cable cover & cable, complete all as specified and directed by Engr-in-Charge :-
4 core 25 Sqmm
4 core 35 Sqmm
2 core 10 Sqmm
Excavation in trenches for not exc 1.5 metre wide and not exc 1.5 metre depth and getting out in soft/loose soil including taking out faulty cable/cable covers and GI pipe, complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exc 25cm , complete all as specified and directed by Engr-in-Charge.
Removing excavated materials not exc 50m and depositing where directed at a level not exc 1.5m above the Starting point, complete all as specified and directed by Engr-in-Charge.
Material and Labour for dry river sand as sand cushioning for protection of UG cable including punning of sand in layers, complete all as specified and directed by Engr-in-Charge.
Supply & laying un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm, complete all as specified and directed by Engr-in-Charge.
Taking out old un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm, complete all as specified and directed by Engr-in-Charge.
Laying only un-reinforced precast concrete cable cover class LV type 1, flat size 250mm x 150mm x 40 mm, complete all as specified and directed by Engr-in-Charge.
Material and Labour GI pipe light grade with all fittings complete laid in trenches all as specified for 50 mm bore of pipe, complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair flame proof LED flood light 100w fitting , fitted on wall surface, complete all as specified and directed by Engr-in-Charge. Note: The rate includes taking down old light fitting and providing suitable necessary ladders /equipments for any height to taking down the items.
Supply and Fix modular AC box with MCB SPN 20 Amp including inner, outer and metal flush box, complete all as specified and directed by Engr-in-Charge.
Supply and fix two way sheet metal enclosure with three pin socket and plug top and 20 amp single pole MCB , complete all as specified and directed by Engr-in-Charge.
Supply and Fix socket outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed by Engineer-in-Charge.
Supply and Fix Switch 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and directed by Engineer-in-Charge.
M.K Enterprises (BID ID -3174423)
M/s S.D Construction Co (BID ID -3175958)
Sagar Electricals (BID ID -3176437)
MC Gandhi and Sons (BID ID -3176278)
R A Electric Co. (BID ID -3173073)
Om Sai Enterprises (BID ID -3176015)
shree arihant constrution (BID ID -3173382)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .