| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.1 CrAdmitted-Finance | ₹53.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹53.3 CrAdmitted-Finance | ₹53.3 Cr | L2 | Admitted-Finance |
| 3 | L3₹54.3 CrAdmitted-Finance | ₹54.3 Cr | L3 | Admitted-Finance |
| 4 | L4₹63.6 CrAdmitted-Finance 256 MUNDHELA KHURD NEW DELHI 73 | ₹63.6 Cr | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Eligible |
| Sl No | Description | Qty | Unit | vitrag infra project llp L1 | KALPANA STRUCT CON PRIVATE LIMITED L3 | Dev Engineers L4 | Som Projects Pvt. Ltd. L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :
In cement mortar | 100 | cum | 1,393 ₹1.4 L | 738 ₹73,800 | 7,000 ₹7 L | 770 ₹77,000 |
| 2.00 | Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in:
Channels, angles, tees and flats | 3,000 | kg | 1 ₹3,000 | 9 ₹27,000 | 45 ₹1.4 L | 7 ₹21,000 |
| 3.00 | Dismantling expanded metal or I.R.C. fabrics with necessary battens and beading including stacking the serviceable material within 50 metres lead. | 333 | sqm | 43 ₹14,319 | 139 ₹46,287 | 500 ₹1.7 L | 30 ₹9,990 |
| 4.00 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, for lead upto 5 Km, including all lifts involved.(This item shall be operated only for disposing material obtained from dismantling works) | 80 | cum | 191 ₹15,280 | 507 ₹40,560 | 5,300.35 ₹4.2 L | 515 ₹41,200 |
| 5.00 | Same as item No. 4 above but for lead of 5 Km up to 10 Km | 80 | cum | 291 ₹23,280 | 46 ₹3,680 | 600 ₹48,000 | 125 ₹10,000 |
| 6.00 | Same as item No. 4 above but for lead of 10 Km up to 15 Km | 80 | cum | 341 ₹27,280 | 46 ₹3,680 | 200 ₹16,000 | 115 ₹9,200 |
| 7.00 | Same as item No. 4 above but for lead of 15 Km up to 20 Km | 80 | cum | 391 ₹31,280 | 46 ₹3,680 | 200 ₹16,000 | 105 ₹8,400 |
| 8.00 | Same as item No. 4 above but for lead of 20 Km up to 25 Km | 80 | cum | 441 ₹35,280 | 46 ₹3,680 | 200 ₹16,000 | 95 ₹7,600 |
| 9.00 | Same as item No. 4 above but for lead of 25 Km up to 30 Km | 40 | cum | 491 ₹19,640 | 46 ₹1,840 | 200 ₹8,000 | 85 ₹3,400 |
| 10.00 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 1,326 | sqm | 47 ₹62,322 | 14 ₹18,564 | 650 ₹8.6 L | 15 ₹19,890 |
Tender Value
₹55.2 Cr
EMD Value
₹50 L
Closing Date
20 Sept 2022, 3:00 pmClosed
GM
IREL (India) Limited Corporate Office Mumbai
Selection of contractor for undertaking construction of multi story Corporate Office building of G plus 10 configuration along with allied services at Wadhawali Chembur E Mumbai
2022_IREL_124849_1
IREL/CO/PT/34/2022
Open Tender
Civil Works
670 days
IREL
As per RFP
4 documents required · 4 mandatory
₹0
₹50 L
Yes
IREL (India) Limited Mumbai
17 Oct 2022
5 Aug 2022
21 Sept 2022
5 Aug 2022
20 Sept 2022
24 Aug 2022
5 Aug 2022 - 12 Aug 2022
12 Aug 2022
Amount
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar
Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats
Dismantling expanded metal or I.R.C. fabrics with necessary battens and beading including stacking the serviceable material within 50 metres lead.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, for lead upto 5 Km, including all lifts involved.(This item shall be operated only for disposing material obtained from dismantling works)
Same as item No. 4 above but for lead of 5 Km up to 10 Km
Same as item No. 4 above but for lead of 10 Km up to 15 Km
Same as item No. 4 above but for lead of 15 Km up to 20 Km
Same as item No. 4 above but for lead of 20 Km up to 25 Km
Same as item No. 4 above but for lead of 25 Km up to 30 Km
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including dewatering (if required), getting out and disposal of excavated earth lead upto 50 m and at all lifts/heights, as directed by Engineer-in-charge. All kinds of soil
Same as item No. 11 above but in Ordinary rock
Same as item No. 11 above but in Hard rock (blasting prohibited)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms,at all lifts/heights, including dewatering (if required), getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Same as item No. 14 above but in Ordinary rock
Same as item No. 14 above but in Hard rock (blasting prohibited)
Open timbering over areas including strutting, shoring etc. complete. (Measurements to be taken of the face area timbered): Depth not exceeding 1.5 m
Same as item No 17 above but for Depth exceeding 1.5 m but not exceeding 3 m
Same as item No 17 above but for Depth exceeding 3.0 m but not exceeding 4.5 m
Same as item No 17 above but for Depth exceeding 4.5 m but not exceeding 6.0 m
Disposal of surplus excavated earth for leads from 50 m up to 5 Km including loading charges
Disposal of surplus excavated earth for leads from 5 Km up to 10 Km
Disposal of surplus excavated earth for leads from 10 Km up to 15 Km
Disposal of surplus excavated earth for leads from 15 Km up to 20 Km
Disposal of surplus excavated earth for leads from 20 Km up to 25 Km
Disposal of surplus excavated earth for leads from 25 Km up to 30 Km
Credit for Hard rock obtained at items 13 and 16 above
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lifts
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Supplying and filling murrum in plinth, sub base course to roads etc., including transporting, unloading, spreading, watering proper consolidating with 10 tonne power roller (wherever 10 tonne power roller cannot be operated the consolidation shall be done using 1 tonne vibro roller or heavy duty powered earth rammer) in layers not exceeding 150mm thick and dressing the surface complete as directed (Degree of consolidation 95% proctor density).
Supplying and filling in plinth with zone IV / River sand under floors, ramps, basements etc., including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Same as item No. 35 above but for 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., above plinth level, excluding the cost of centering, shuttering and finishing : 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
Same as item No. 37 above but for 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.
Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc.
Extra for concrete work in superstructure above floor V level for each four floors or part thereof.
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Same as item No 45 above but for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses, water tanks etc.
Same as item No 45 above but for : Suspended floors, roofs, landings, balconies and access platform
Same as item No 45 above but for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Same as item No 45 above but for : Columns, Pillars, Piers, Abutments, Posts and Struts
Same as item No 45 above but for : Stairs, (excluding landings) except spiral-staircases
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all heights and levels Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position M 40 Grade ready mixed concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 390 kg/cum. Excess/less cement used as per design mix is payable / recoverable separately) All works upto plinth level
Same as item No 53 above but for All works above plinth level
Providing and laying in position high strength M-60 grade concrete for reinforced cement concrete work, using cement and ground granulated blast furnace slag in required proportion with cementitious content not less than 500 kg/cum and using coarse aggregate of maximum size 12mm , manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of concrete from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability. Polycarboxylic ether based admixture DYNAMON Series of Mapei / BASF / SIKA / Fosroc or equivalent at dosage of 0.6 to 1.0% (Hyperplastisizer) and 0.05 to 0.1% by wt of cementitious material as recommended by the manufacturer shall be used to achieve the strength. The average slump to be maintained shall be 600 +/- 50mm , w/c ratio 0.32 and free water shall not exceed 160kg/cum, etc complete as per direction of the Engineer - in - charge.(Trails shall be conducted to fix up optimum dosage of admixture) All works upto plinth level
Same as item No 55 above but for All works above plinth level
Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof.
Add / deduct for using extra / less cement in the items of design mix over and above the specified cement content therein.
Providing, hoisting and fixing above plinth level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
Designing, detailing, supplying, installing, profiling, stressing and cement grouting for bonded type Post Tensioning (PT) work with HT strands of approved make conforming to IS 14268-1995 for PT slab & PT beam. Rate shall be inclusive of supplying of HT strands and sheathing (Galvalume corrugated ducts) of approved make, decoiling the strands, cutting the same to required lengths and laying of HT strands, jointing with couplers, inserting the strands, profiling, fixing live end anchorages including the supply of stressing anchorages, casting, barrels, wedges, end plates suitable for tendons, grout of vents, making dead end anchorages including flowering the strands, fixing tendon support bars, supervising and fixing of anti bursting reinforcement, stressing the cables, end trimming, grouting the cables with cement and admixtures, strip painting at strand locations, including necessary materials, accessories, Plant & Machineries, tools and tackles, scaffolding, consumables etc., obtaining design approvals from consultant for the work etc., complete as directed by Engineer-in-charge.The scope of work includes the following : i) Supply of specialist Post tensioning materials like high tensile steel, (TATA / Usha Martin) approved patented anchorages with castings and wedges, galvanized corrugated ducts, etc., ii) Providing all necessary equipments for carrying out post tensioning works. iii) Laying, stressing and grouting of the PT cables as per the shop drawing . iv) Filling or dry packing of the block outs, recesses joints etc., v) Supply of fresh cement and additives for grouting. vi) Necessary working platform vii) Adequate safety measures to be adopted. viii) Cost to be included for Laboratory Test of materials( Like High Tensile Steel Srands) and field test if required. Note: Proper design calculations, methodology, sequence of construction and post-tensioning activities, detailed drawings along with detailed quantities of non prestress steel & PT tendons, showing layout of strands / cables, anchorage details, profiles of cables etc., shall be submitted to the structural consultants for their approval prior to proceeding to execute the work.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 Coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 Coarse sand)
Providing and fixing above plinth level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete all as per specification / Drawings or as approved by Engineer-in-Charge 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing above plinth level 100mm thick Block Masonry with precast cement concrete solid block, including placing in position 2 Nos 6mm dia. M.S. bars at every third course of 100mm soild Block masonry, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Second class teak wood
Providing and fixing Galvanized steel door frames finished with polyurethane paint, manufactured from galvanized steel sheet conforming to IS 4351-2003 of 1.20 mm thickness, including jamb, lock jamb, bead and if required angle threshold of steel angle of section 50x25 mm, or base ties of 1.20 mm, steel welded or rigidly fixed together by mechanical means, including lock strike-plate and shock absorbers including fixing with adjustable lugs with split end tail to each jamb and filling with cement concrete 1:3:6 by using 20mm and down graded metal complete as specified and applying a coat of approved zinc phosphate stoving primer to receive thermo setting polyurethane paint or Epoxy paint etc., complete as directed by Engineer-in-charge: Profile C
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) laminated type, core of block board construction with frame of 1st class hard wood and fixing 1mm thick laminate (of approved colour) on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing and fixing of Hollow metal General purpose door at all levels from ISO 9001-2000 certified Manufacturer (Sukriti / Navair / Promat / Shakti met) with or without vision panel. Pressed Galvanised steel Single /Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be Single rebate profile of size 100 x 58 mm made out of 1.20mm thick galvanised steel sheet (18 gauge). Frames should be Mitered and field assembled with self tabs. Door leaf should be 46 mm thick , double skin door shell and manufactured from 0.80 mm thick galvanised steel sheet (22 gauge). The infill material shall be resin bonded honey comb paper glued and sandwiched in between with an interlocking arrangements. Vision lite wherever applicable should be of size 150mm x 750mm. All doors should be factory preped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks and door closers. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed should be grouted with cement slurry if recommended on the clear masonary opening. Door leaf should be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (22 guage) thick galvanised steel sheet. The internal construction of the door should be rigid with steel stiffeners/ pads and reinforcement. The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges should be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable should be asper joinery details with a screw on glass beeding on the inside. The glass should be 5mm clear toughened glass. Louvers when recommended should be site proof and shall be flush fixed on the external surface. All doors and frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved RAL colour. The door leaf and frame shall have passed minimum 250 hours of salt sprey test. Rate should include supply and installation of door and hardware set as mentioned in the door and hardware schedule. Single leaf door of size 0.9 m X 2.1 m and S.S.Butt hinges, Door closer, Mortice dead bolt, S.S. 'D' Handle, Clear float glass 6mm thick of size 150 x 750mm
Same as iterm No 78 above but for double leaf door of size 1.5 m X 2.1 m and S.S.Butt hinges, Door closer, Mortice dead bolt, S.S. 'D' Handle, concealed flush bolt, Clear float glass 6mm thick of size 150 x 750mm
Supplying and fixing 120 minute fire rated galvanized steel door (Sukriti / Navair / Promat / Shakti met) conforming to IS 3614 (Part II) of approved make with door frame made of 1.6mm thick galvanized steel sheet conforming to IS : 277, 1992 formed to double rebate profile of size 143mm X 58mm (+/- 0.3mm ) with a maximum bending radius of 1.4mm.The shutter shall be made of 1.2mm thick galvanized steel sheet conforming to IS : 277, 1992 formed to provide a 46mm thick fully flush double skin door shell with lock seam joints at stile edges and filled with mineral wool. Internal reinforcement may be provided at top, bottom and stile edges for fire rating. The door frames may be built into the brick or block walls using corrugated "TEE" anchors not welded to the frames or with the help of metallic expansion shield with counter sunk screw. The door frames and shutters have to be coated with zinc phosphate stoving primer to receive thermosetting polyurethane paint of Aliphatic Grade or epoxy paint as per manufacturer specification etc., all complete as per the direction of Engineer-in-Charge. (The sizes mentioned are clear masonry openings) Double leaf door of size 2.0m X 2.4m Clear fire rated vision glass 6mm thick of size 200 x 300mm, S.S.Butt hinges, external lever handle, door closer with standard arm, panic bar, Vertical Pullman latch with rod & cover, door coordinator, S.S. Gasket fire rated, smoke seal etc complete.
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/ m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- charge . (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS 16231 (Part 3):2016 and as per direction of Engineer-in- charge with glass of required thickness having 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of insulation (EI20). The manufacturer have to give test report/certification of fire glass and the glass should have the stamp showing the value of E, EW & EI. The glass shall be tested in approved NABL accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and calibration scopes shall be eligible. The maximum glazing size shall not be more than 1100x2200 mm (w x h) or 2.42 sqm.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing 8 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing 2 Ball bearing butt hinges of size 4" x 3" x 3mm in SS 304 and in SSS finish , 5 Knuckle ,template drilled of model no : BB 4330 of Dormakaba or equivalent, suitable for door weights upto 120kgs.
Providing and fixing Dead Lock with 55mm backset, 20mm square forend prepared for euro profile cylinder including strike plate and EPC 60mm length, both side key operation & Escutcheons in SSS Finish of model no : 278a Type 1 of Dormakaba or equivalent.
Providing and fixing pull Handle of length 300mm and 22mm dia, made of SS 304 grade , of model no : TGDI-D300 of Dormakaba or equivalent , single side with adjustable fixing for wood and metal doors in satin stainless steel finish. The pull handles shall have supporting washer with raised bevelling on the outer surface.
Providing and fixing pull Handle of length 450mm and 25mm dia, made of SS 304 grade , of model no : TGDI-H450 of Dormakaba or equivalent, back to back with 350mm CTC, adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles shall have supporting washer with raised bevelling on the outer surface.
Providing and fixing rack and pinion door closer of model no : TS 68 of Dormakaba or equivalent, EN size 2/3/4, with std. arm and with two independent closing valves and latching speed adjustable by arm , Silver finish and as per EN 1154.
Providing and fixing wall mounted door stop dome of model no : 4012 of Dormakaba or equivalent , of 60mm length with fixing accessories.
Providing and fixing floor stop half dome in satin Chrome, of model no : 3108 of Dormakaba or equivalent , 45mm dia with fixing accessories.
Providing and fixing door lock cum handle of model no : Pure 8100 of Dormakaba or equivalent ,Type 3 Package with Pair of Pure 8100 Design Lever Handle on Roses & escutcheons , including 271a Sash lock with 72mm CTC, 55mm Backset 20mm Square forend, EPC 60mm length oneside thumb turn otherside coin release operation .
Providing and fixing cam action door closer with slide channel arm, Silver finish of model no : TS 90 of Dormakaba or equivalent , Spring size EN 3/4 as per EN 1154 and CE marked.
Providing and fixing disable sign plate of model no : 3040-D of Dormakaba or equivalent, for WC application with fixing screws size 125 x 125mm, rounded corners in SS 304 satin stainless steel finish and marking in black.
Providing and fixing Coat hook of model no : 3106 of Dormakaba or equivalent with face fixing screws in satin stainless steel finish.
Providing and fixing Standard Bottom Patch Fitting of model no : PT 10 of Dormakaba or equivalent
Providing and fixing Standard Top Patch Fitting of model no : PT 20 of Dormakaba or equivalent
Providing and fixing Standard Lock with Strike plate & EPC of model no : US 10 of Dormakaba or equivalent.
Providing and fixing Univeresal centre Lock of model no : US 20 of Dormakaba or equivalent.
Providing and fixing Studio Gala Hinge including sleeve of Dormakaba or equivalent, for 8mm glass door .
Providing and fixing Studio Gala lock set with studio gala lock and pair of studio gala lever handle without roses prepared for profile cylinder of Dormakaba or equivalent.
Providing and fixing 5 pin Euro profile cylinder with both side key operation of model no : 3025 of Dormakaba or equivalent, standard length 60mm in satin nickel plated finish with 3 keys.
Providing and fixing Universal cam action Saddle Plate of model no : TS91/92/93 of Dormakaba or equivalent .
Providing and fixing Cushioned limit stay for cam action door closer, adjustable between 80° and max. 120°, to prevent a normally opened door from colliding with adjacent walls.
Providing and fixing MUTO Comfort L 80 Manual sliding door system of Dormakaba or equivalent , for Glass/Timber panels for the maximum door width and height of 1500mm X 3000mm. suitable for glass door thickness of 8mm to 13.5 mm and timber panel thickness of 28mm to 50mm, which can be installed on Wall or ceiling or glass , tested to Corrosion as per EN 1670 Class 4 and DIN EN 1527.
Providing and fixing Flush Pull Knob suitable for 8 /10/ 12 mm thick glass of Dormakaba or equivalent .
Providing and fixing, 5 Knuckle, 2 bearing butt hinges size 4" x 3" x 3mm, in SS 304 and in satin stainless steel. As per EN 1935, CE Marked. Suitable for door weights upto 120kgs,of model no : 3090F of Dormakaba or equivalent .
Providing and fixing,1 point panic device in Contur design on active leaf and 2 point modular on inactive leaf, push bar for rebated double door. For fire and smoke check doors, with steel latch, security anti thrust latch for door widths upto 1300mm, height upto 2270mm consisting of 2 x 2102F, 2 x 2105, PHX 04 and PHX 03 in silver finish. As per EN 1125, CE marked, of Dormakaba or equivalent .
Providing and fixing, External trim for PHA, PHB Panic Hardware for fire and smoke check doors. For max. 60mm thick door prepared for euro profile cylinder. Silver finish of Dormakaba or equivalent .
Providing and fixing, 5 pin Euro profile half cylinder with one side key operation standard length 42mm in satin nickel plated finish with 3 keys. Optional master keying and grand master keying can be done on request. -NMK,of model no : 3005 of Dormakaba or equivalent .
Providing and fixing, rack and pinion door closer TS 71 EN size 3/4, with std. arm and with two independent closing valves and latching speed adjustable by arm. Full plastic cover. Silver finish. As per EN 1154,of Dormakaba or equivalent .
Providing and fixing, Gravity Type Co-ordinator, of Dormakaba or equivalent .
Providing and fixing, floor spring BTS 75V EN 1-4 with std. spindle and cover plate. The floor spring with backcheck and adjustable closing speed from 175°. . With 90°. hold open. As per EN 1154. (not suitable for fire doors) Finish: Satin stainless steel. Application - Glass Doors,of Dormakaba or equivalent .
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete.
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm
Providing and fixing Teak wood panelled acoustically insulated double shutter door,made of second class teak wood frame of size 160mm x 100mm , cut to shape, top & bottom styles of 175mm x 60mm , intermediate styles of 125mm x 60mm , vertical styles of 100mm x 60mm , with internal grids made of teak wood panels of size 390mm x 440mm x 60mm thick cut to shape and filled with 10mm thick insulation , including necessary beading , cost of all material , labour and all other incidental charges etc., complete including cost of providing four nos heavy duty brass butt hinges , 2 nos ornamental brass handles, locking arrangement, tower bolts on inside of shutters etc all as per drawing and as directed by Engineer-in-Charge.
Providing and fixing partition of 100mm thick with aluminium frame work made of box section 60mm x 50mm x 2.0mm thickness, duly anodised conforming to IS : 1868 (1996) at maximum spacing 1200mm center to center vertically and 600mm center to center horizontally and 50 x 25 x 6mm 'L' Shaped MS cleat providing and fixing 12mm thick ply wood on both sides and pasted with 8.0mm thick pre-laminated MDF Board, pattern shall be as per the direction of Engineer-in-charge. Laminate shade and groove pattern shall be as per the approval of Architect /Engineer in charge . The aluminium frame above the door also shall be fixed firmly to the RCC slab with the help of MS 'L' shaped cleats of size 50x50mm and 6mm thick using rawl plugs.
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete. 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum board conforming to IS: 2095: (part 1) : 1996 (Board with BIS certification marks)
Providing and fixing glass partition with clear laminated glass 14.76mm thick, made after sandwiching polyvinyl butyral 0.76mm thick between 6mm and 8mm thick tempered glasses, maximum size upto 1500mm x 2400mm, shall be fixed into aluminium 'U' channel frame of size 20mm x 18mm x 20mm of 4mm thickness, duly anodised conforming to IS : 1868 (1996) and firmly fixed with rawl plugs to bottom and top of existing surfaces. Butt joint between two glass panes to be fully filled with transparent silicon, (DOWSIL TM TSSA Transparent Silicon) or equivalent and using silicon sealants of DC995 or DC 983 (two parts) of DOW CORNING or approved equivalent, in top and bottom aluminium frames, and partition shall be supported on sides with frame in wooden , to achieve a straight and strong partition, perfectly in plumb and line, to the satisfaction of Engineer in charge. The measurement shall be taken from the floor finish to the false ceiling (i. e top of the bottom 'U' channel to bottom of the top 'h'/ 'U' channel) and the glass outside the wooden beadings on the sides.
Providing and fixing toilet partitions of size upto 1200mm x 1500mm and 2000mm height made of 12mm thick solid compact laminate board (Phenolic core board) based on thermosetting resins, homogeneously reinforced with cellulosefibres . The intermediate panel shall be one continued panel without any joints. All intermediate panels, panels, pilasters and doors shall be 12mm thick with edges chamfered.Frame work shall be with SS coated aluminium U channel for fixing the intermediate panel to the wall and also for fixing the door. All pilasters shall be supported by adjustable foot and non corrosive inserts. Top rail and wall fixing with exterior polyamide coating and shall guarantee resistance to breakage, heat, humidity and chemicals. The base of the adjustable foot shall be anchored to the floor with a clearance height of 100mm .The top surface shall be melamine coated on both sides and shall be scratch and impact resistant. Each toilet compartment shall be equipped with accessories in stainless steel smart series privacy thumb turn, door knob, coat hook, auto return hinges, adjustable legs, SS coated aluminium top profiles etc., all complete
Providing & fixing Non Woven fabric backed Vinyl Wall covering 470 GSM, of size 1.32 m x 27.4 m with PVF Film. The wall covering shall meet or exceed criteria of CCC-W-408D, ASTM F793, ASTM E84 Class A, NFPA 286, ASTM G21, JIS Z2801. It shall be compliant with FDA regulation CFR 175.270, exceed Vinyl Wall covering Type III durability, can be used in interior & exterior application. It should have low VOC having Green Guard Gold certification etc complete as per specification and as directed by Engineer-In-Charge.
Providing wall panelling of Armstrong Industries or approved equivalent make as per specification and direction of EIC at all heights and levels. Providing and Fixing Channeled Woodworks perforated panels of Armstrong Industries or approved equivalent make of width 128mm, thickness 16mm and length 2440mm or as required by the Engineer-in-Charge, made of a high density particle board substrate with a laminated facing as per the approved shade/ species & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a (“Helmholtz” fluted perforation of 2mm width and 14mm of visible panel / 4mm width and 28mm visible panel) each. The panels shall provide a minimum sag resistance of RH90 and a fire rating class of 1 as per Part 7 of BS 476. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece. The panels shall be mounted on special aluminium splines using clips as approved by the Engineer-in-Charge. Wooden battens of section 50mmx50mm or as approved by the Architect are installed on the solid wall horizontally using screws and plugs at spacing of 800mm centre-to-centre. Cut to size and screw the aluminium section frame for border panel (GTITC002) provided by Armstrong over the lowest and second wooden batten. Install the wooden panels one-by-one by inserting the groove of the panel. Install the aluminium section extruded frame for inside panel (GTITC001) with the longer end away from the inserted panel and shorter edge into the groove of the installed panel. Place this against the wooden batten and screw. Continue installing rows of panels till the actual height/length is achieved. Glue or screw the glass fibre insulation on to the wall in the void formed between the wall and panels, if required.
Providing and supplying ‘Optra Acoustical Wall Paneling’ of Armstrong or approved equivalent make with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A, as per ASTM E-84, fabric with an option of colors – Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut and Shell as per the choice of the Architect of size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel Impalers and construction adhesives as per the instructions laid down by the manufacturer. Installation The panels shall be fixed to the wall with the help of the Impalers , which shall be fixed to the wall surface using self tapping screws. 3 nos. in case of 600x600mm, 4 nos in case of 600x1200mm and 5 nos in case of 600x1800mm .Wall panel Impalers to be used for the installation purpose. Silica based construction adhesive to be dabbed on to the projecting elements (spikes) of the impalers and wall panels shall be pierced through the spikes of the impalers ensuring the line and level of the panels are maintained.Installation to be carried out by Trained Installation team & Installation should be carried out as per manufacturer recommended procedure.
Providing and fixing 100 x 20mm thick teak wood skirting over wall panelling including wax polish after filling wood filler and sand papering up to smooth finish complete as per drawing and direction of Engineer-in-Charge.
Providing and fixing point fixed Glass Canopy system using 2/4 way spider / GT Spiders / Loop, Rodan & Tensile Rod / Wire ( Dorma / Hafele / Ozone) including supplying and fixing 13.52mm thick laminated glass (Saint Gobain / Asahi / Modi or equivalent) having 6mm thick as outer & inner panels with interlayer of 1.52mm thick . Outer pane glass shall be reflective coated glass and inner pane shall be heat soak tested uncoated clear glass and both panes shall be heat treated. The glass shall be supported on frame work made of RHS sections 48 x 96 x 3.2mm / 61 x 122 x 4.5mm thick suitably designed and fixed to RCC / MS work with 150 x 200 x 12mm thick insert plates . Rate shall include for complete system including glass , frame work , spider fiitings and other necessary accessories for finishing the job as per requirement and as directed by Engineer - in - Charge.)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing 10 mm thick toughened glass to the baluster of SS railing fixed with SS Studs, including all accessories and labour charges for fixing
Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 Coarse sand), finished with a floating coat of neat cement. 18 mm thick
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 Coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre.
Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Providing and fixing machine cut, mirror/ eggshell polished, Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying flamed finish Granite stone flooring for treads in single piece of required length, in required design and patterns ,in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Providing and laying Polished Granite stone flooring for treads in single piece of required length, in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
Providing and laying Polished Granite Stone work for skirting, risers of steps over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 Coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete.
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Providing grooves in treads of granite steps, 3 Nos. In each tread of width 6mm and depth 6-8mm (Effective area of Tread shall be measured for payment)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab upto 0.50 sqm
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete
Providing and fixing 18 to 20mm thick Polished Granite cladding with edge chamfering whereever required of approved shade stones of required size, backing filled with a grout of 12mm thick in cement mortar 1:3 (1 cement :3 Coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade complete for all heights and lifts as per drawing and directions of Engineer-in-charge. (To be secured to the backing by means of stainless steel cramps which shall be measured as a separate item)
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases.
Providing and laying Double Charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x 600 mm
Same as item No. 155 above but for Size of Tile 1000x 1000 mm
Providing and laying Double Charged Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm
Same as item No. 157 above but for Size of Tile 1000 x 1000 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
Providing and installation of Vinyl Sports Sheet Flooring 1.8m wide and 11 m long, having a nominal total thickness of 8mm of approved design and shade as per the Architects choice and Engineer-In-Charge. The wear surface shall be 0.8 mm and PUR coated with UV Treatment. Vinyl sheet floor shall conform to flammability Class Cfl as per EN 13501-1;Shock Absorption more than 42%; sliding coefficient of 0.45-0.65; energy return of 0.45m/s; vertical deformation of 3mm and sound insulation of 25 - 28 db. Impact Resistance of 8N/M (as per DIN18032); Abrasion Resistance of 7 mm, Indentation Resistance of 0.6mm (as per EN1016), Friction Coefficient of 0.6 (as per GB/T14833-1993) and Rebound Coefficient of 0.86 (as per GB/T14833-1993). It shall be installed by authorised applicator only .
Providing and fixing of floor carpet of tile size 500 x 500 mm, Tufted loop & Multi level loop with or with out tip sheering , Solution Dye Nylon 6.0 Carpet tiles with PVC backing , of approved make, with Yarn -1200/2, 69F with 26-28 OZ/y2 ( 85 GSM or above) 1/12 or 1/10 Gauge, Colour point technology with 4.5mm Pile and 7.5mm thickness, and with over all Density not less than 8000 ,Tolerance (+/-) 5 % Product shall be tested and certified as below 1) Indoor Air Quality - GLP2526 2) Pill Test -Pass 3) Flooring Radiant Panel - Class1 (ASTM E-648) 4) Smoke Density - Less than 450 (ASTM E-662) 5) Less than 3.5 kV (AATCC-134) 6) Lightfastness - Pass 7) Surface Flammability of Carpets and Rugs ( ASTM D2859) 8) Anti Vital Treatment is Mandatory - ISO 18184: Determination of Antiviral Activity of Textile Products 9)TARR > 3.0 The carpet shall be installed with Non- VOC adhesive of Pidilite or approved equivalent material and shall have high grade poly Cover sheet for soil protection etc complete to the satisfaction of Engineer-in-Charge.
Providing and fixing of Laminated wooden flooring & skirting (thickness as per manufacturers specifications), classification of use 33/23 with a surface abrasion resistance of class AC5 (average 6500 cycles), impact resistance of 7.7mm, resistance to cigarette burn with a rating of class 184(EN 438-2:05), swelling after 24 hrs in water of 8.22%, Modulus of rupture of 53.3 newton/mm2, Internal bond 1.78 newton/mm2, surface soundness 2.62 newton/mm2 (EN 13329:2000) with a 0.2 mm thick wear layer on top of a High Density Fiber substrate core (density ~ 948.3 Kgs/M3) of plank size 1200 mm x 125 mm x (thickness as per manufacturers specifications) having locking arrangement (lock strength > 1100 lbs/ft) with an underlayment made of natural colour foam, with accessories like End profile, Transition profile, reducer, Stair nosing etc. complete. INSTALLATION: It is important to ensure the sub floor on which the laminate is being laid is smooth, flat & hard & free from moisture, grease, etc. In case of uneven sub floor the same should be levelled by self levelling compound. The moisture level present in the subfloor should be less than 8% before installation of the floor. It is recommended to use a water barrier of minimum of 250 microns and 2mm polyethylene foam under the planks. The installation shall be undertaken as per the manufacturer’s installation instructions
Providing and fixing removable raised/false access flooring with system and its components (Unitile/ Unifloor/ Pinnacle or equivalent make) for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of a) Providing at required spacing to form modular framework, pedestals made out of GI tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug. b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge. c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be corrosion resistant epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and, an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 450 mm Finished Floor Height (FFH).
Providing and fixing steps for false flooring with treads of width 300mm and risers as 150mm using 19mm thick marine plywood boxing with necessary hardwood framework 50mm x 50mm at the corners with necessary supports at edges or as directed. The exposed edges of the steps to be finished in anti-static laminate of approved make and sample. Mode of measurement to be running length of step. (Treads and risers will not be paid separately). Height of raised flooring : 450mm
Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diametre of working pressure 4kg/sqm
Same as item No. 168 above but for 160 mm diametre of working pressure 4kg/sqm
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm of working pressure 4kg/sqm
Same as item No. 169 above but for Coupler 160 mm of working pressure 4kg/sqm
Same as item No. 169 above but for Single tee without door 110x110x110 mm of working pressure 4kg/sqm
Same as item No. 169 above but for Single tee without door 160x160x160 mm of working pressure 4kg/sqm
Same as item No. 169 above but for Shoe (Plain) 110 mm Shoe of working pressure 4kg/sqm
Same as item No. 169 above but for Shoe (Plain) 160 mm Shoe of working pressure 4kg/sqm
Providing & fixing Fibre Glass Acoustical Suspended Ceiling System with 15mm thick bevelled tegular Edge Tiles of Armstrong or equivalent , installed on Silhoutte 15mm exposed grid of Armstrong or equivalent. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, , Light Reflectance ≥85% as per ASTM E-1477, Colour Pebble White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 15mm bevelled Tegular/ 90˚ edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 66% (GW)/ 74% (RW). The tile shall be laid on Silhoutte Black Reveal 38 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 14Kgs/M2 & minimum pull out strength of 100 Kgs.. The T Sections shall have a Galvanizing of 90 grams per M2 and need to be installed using suitable Suspension system. The Tile & Grid system used together shall carry a 30 year warranty. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using suitable suspension system at 1200mm maximum centre. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim shall be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres. Installation to be carried out by trained Installation team and as per manufacturer recommended procedure.
Providing & fixing Mineral Fibre Acoustical Suspended Ceiling System with bevelled tegular edge tiles of Armstrong or equivalent , installed on Silhoutte 15mm exposed grid of Armstrong or equivalent. The tiles shall have Humidity Resistance (RH) of 99%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on Silhoutte Black Reveal 38 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 14Kgs/M2 & minimum pull out strength of 100 Kgs.. The T Sections shall have a Galvanizing of 90 grams per M2 and need to be installed using suitable Suspension system. The Tile & Grid system used together shall carry a 30 year warranty. INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural soffit using suitable suspension system at 1200mm maximum centre. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim shall be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres. Installation to be carried out by trained Installation team and as per manufacturer recommended procedure.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
Providing & Fixing of Armstrong Wooden finish Suspended Ceiling System with WOODWORKS (MICRO LOOK) EDGE TILES of ARMSTRONG INDUSTRIES or other approved equivalent make WITH XL 15 MM EXPOSED GRID. The tiles shall be of perforation pattern R3/R3B/R6/O6/O11/O12/SQ01 perforation with approved laminate/natural veneer finish and shall have Humidity Resistance (RH) of 90%, Fire Performance Class 1(BS - 476) in module size of 600mm x 600mm x 12mm The grid shall consists of 15mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 43mm and a load carrying capacity of 23.71 Kgs/M2. The T Sections have a Galvanizing of 120 grams per M2 & passed through 500 hrs of Salt test. The Tile & Grid system used together should carry a 15 year warrantee. INSTALLATION: Shall comprise main runner spaced at 1200mm centers securely fixed to the structural soffit using Armstrong suspension system (specifications below) at 1200mm maximum centre. The First/Last Armstrong suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be Armstrong wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centers. SUSPENSION SYSTEM accessories manufactured and supplied by Armstrong World Industries or other approved equivalent make consisting of M6 Anchor Fasteners with Vertical Hangers made of Galvanized steel of size 26 x 26 x 25 x 1.2mm with a Galvanized Thickness of 80gsm, A pre Straightened Hanger wire of die – 2.68 mm of 1.83 m length., thickness of 80gsm and a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.8mm thick, galvanized spring steel for 2.68 mm with a minimum pull strength of 110 kg. The adjustable clip also consists of a 3.5 mm aquiline wire to be used with the main runner. Note: The rate quoted shall include the cost of making opening for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of Engineer-in-charge
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
20mm thick plastering in cable trench and similar locations with cement mortar 1:3 (1cement: 3 coarse sand) with water proofing compound mixed as per manufacturer instruction, a floating coat of neat cement including benching, haunching, providing over flow pipes and proper slopes, all as directed by Engineer-in-charge. (inclulding cost of water proofing compound)
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
White washing with lime to give an even shade : New work (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two Coats
Melamine polishing on wood work (one or more coat)
Providing and fixing white vitreous china wall hung water closet of approved brand/ make, shape, size and pattern including providing & fixing PP soft close seat cover, single piece Slim concealed cistern body with installation kit and S type drain pipe connection set, with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 2 litre/ 4 litres), including fittings, nuts, bolts, gasket, hinges and accessories set etc complete in all respect as per directions of Engineer-in-Charge. (Jaquar make Wall Hung- WC of Model No. SLS-WHT-6953BIUFSM , Concealed Cistern : Jaquar Model - JCS-WHT-2400S , Control Plate of Jaquar model no JCP-CHR-852415 or Equivalent model from Parryware / Hindware)
Supply, Installing, testing and commissioning EWC & concealed Cistern (2/4 dual flush) complete with fittings & seat cover for Physically Challenged with increased height for convenience with 'P' or 'S' trap with cistern with raised soft- push button for convenient access, with grab bars and hinged bars necessary for physically challenged toilets with all internal parts for efficient functioning with polypropylene solid hard seat and cover of with polythene buffers and flap, brass CP wall flanges, brass CP bolts and nuts 15mm brass CP angle valve, 450 mm long inlet (type) connection pipe, all HINDWARE Cat 70002 or Equivalent model from Parryware, (Wash basin 46 x 36 with one pair mounting brackets, ewc & cistern complete with fittings & seat cover, one no. Hinged rail 76 cm & 5 nos. of grab rails 60 cm COMPLETE) with mounting chair bracket custom made to specific dimensions as mentioned by the architect / engineer, fixing of 110mm dia straight type straight syphon UPVC WC pan connector with neoprene rubber ring and necessary accessories etc., complete. (All fittings of approved make). Supply and fixing of vitreous china oval type wash basin for Physically Challenged of HINDWARE MAKE, make colour, with cold water supply connecting pipe with angular stop cock, CP waste coupling with plug chain, 32mm dia CP bottle trap, etc of approved make. The work shall include cutting and making good the walls and floors complete. Supply and fixing of 15mm dia CP pillar cock with aerators / flow restrictors. The work shall include cutting and making good the walls and floors. (All fittings of PARRYWARE MAKE or Equivalent model from Jaquar) (Flow rate - 1.3 LPM @ 58 PSI)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Supply and fixing of Health Faucet (ABS Chrome Plated) of the closet mounting type with hose, hand shower (Health Faucet) with 8mm Dia 1.2m long Flexible tube and Wall Hook with complete fittings of JAQUAR make - ALD-565 or Equivalent model from Parryware / Hindware. (All fittings of approved make) (Flow rate - 8.52 LPM)
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approved brand/ make, shape, size and pattern, having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (Jaquar make No. URS-WHT-13255 or Equivalent model from Parryware / Hindware)
Providing and fixing Sensotronic Sens Flushing Valve for Urinal with complete Kit (Jaquar make, Model No.SNR-CHR-51097 (Flow rate 1.5L) or Equivalent model from Parryware / Hindware)
Providing and fixing urinal partition made of glass of width 450mm and height 900mm, made of 8mm thick Curved shaped urinal partition with frosted glass (Jaquar make, Model No JSE-CHR-810UC450X) fixed to the wall with stainless steel (SS-304 grade) accessories like L clamp with SS screws etc all complete to the satisfaction of Engineer-in-Charge.
Providing and fixing Table top Wash Hand Basin comprising of; a) Glazed vitreous china Table top wash basin of approved brand/ make, shape, size and pattern of (Jaquar make, Model No.JDS-WHT-25937 or Equivalent model from Parryware / Hindware) b) One Aquisense sensor faucet for wash basin with base flange (Jaquar make, Model No.SNR-CHR-51011 or Equivalent model from Parryware / Hindware) c) One 15mm heavy quality flexible PVC inlet pipe connection with C.P.brass hexagonal check nuts with washers at both ends. d) One 15mm Angle Stop Cock (Jaquar make, Model No. KUP-35053PM or Equivalent model from Parryware / Hindware) on the inlet to the basin e) One 32mm heavy quality CP brass waste coupling with rubber plug and CP chain (JAQUAR-ALD-709 or Equivalent model from Parryware / Hindware) f) Bottle Trap of JAQUAR Code No. ALD-769L or Equivalent model from Parryware / Hindware with internal parttion, 32mm size with 300mm and 190mm long wall connection pipes and wall flange. g) 32mm PVC waste pipe with specials from extension piece of the bottle trap to the floor trap, length not exceeding 1mtr.concealed in the wall.
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm
Same as item No. 201 above but for Kitchen sink without drain board 610x510 mm bowl depth 200 mm
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Providing and fixing in position Toilet paper roll holder with flap recessed type (Jaquar Code No. AKP-35753PS) or Equivalent model from Parryware / Hindware with necessary CP screws and washers fixed to wall, fixing and making good the surface etc; complete all as specified and directed.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing UPVC floor trap with 75mm dia outlet "Supreme" or Equivalent model from Parryware / Hindware, including connection with PVC soil / waste pipe, necessary 150mm thick CC 1:2:4 for embedding the trap including providing and fixing top rail and strainer on top of the trap etc. complete all as per specifications and as directed by the Engineer in-charge.
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With Sewer bricks conforming to IS : 4885
Providing and fixing in position soap dish Jaquar- Code No. AQN-7731 or Equivalent model from Parryware / Hindware with necessary CP screws and washers fixed to the wall etc. Complete all as specified.
Providing and fixing CP liquid soap container JAQUAR - AKP-35735P or Equivalent model from Parryware / Hindware of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
Providing and fixing in position best approved quality robe hook of Jaquar code no. AKP-35791P or Equivalent model from Parryware / Hindware, fixed to wall with necessary screws, plugs, etc. all as specified and directed.
Providing and fixing in position Towel Ring of Jaquar- Code No. AQN-7721 or Equivalent model from Parryware / Hindware with necessary CP screws and TW plugs fixed to wall complete all as specified and directed by EIC
Providing and fixing in position Soap dispenser of Jaquar- Code No. SDR-WHT-DJ0010F or Equivalent model from Parryware / Hindware of capacity 0.8L, made of ABS material and white / smooked finish etc., complete all as specified and directed by EIC
Providing and fixing in position Hand dryer of Jaquar- Code No. HDR-SAP-M06ACS or Equivalent model from Parryware / Hindware, made of AISI 304 stainless steel and satin finish etc., complete all as specified and directed by EIC
Providing and fixing 6mm thick frameless mirror fixed to the wall / tiles with wall anchors, glue and mirror clips screws including all incidentials etc all complete as directed by engineer-in-Charge.
Supplying, Laying and fixing in position under floor against wall in chases PVC SWR drainage pipes and specials, rubber rings conforming to IS13592 Type "B" of "Supreme" or Equivalent model from approved makes as per manufacturers specification including cutting the pipes to required lengths, necessary excavation, chasing the walls and concrete surfaces and restoring to original conditions, testing etc complete all as per drawing and as directed by the Engineer in charge. .(Specials at Junction of lateral pipe and vertical stack must have access door for inspection) 50 mm diameter
Same as item No. 215 above but for 75 mm diameter
Same as item No. 215 above but for 110 mm diameter
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 3.5
Supplying and fixing of PVC cowl of 100 mm dia of approved brand, quality etc., all complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal outer dia Pipes
Same as item No. 220 above but for 32 mm nominal outer dia Pipes
Same as item No. 220 above but for 40 mm nominal outer dia Pipes
Same as item No. 220 above but for 50 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer dia Pipes
Same as item No. 224 above but for 20 mm nominal outer dia Pipes
Same as item No. 224 above but for 25 mm nominal outer dia Pipes
Same as item No. 224 above but for 32 mm nominal outer dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore
Same as item No. 228 above but for 25 mm dia nominal bore
Same as item No. 228 above but for 32 mm dia nominal bore
Same as item No. 228 above but for 80 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore
Same as item No. 232 above but for 25 mm nominal bore
Same as item No. 232 above but for 32 mm nominal bore.
Same as item No. 232 above but for 80 mm nominal bore
Supply and fixing of Bib Cock (Straight line Model) with wall flange of Jaquar make, Model No. KUP-35041PM / Parryware / Hindware or approved equivalent make with complete fittings of approved make. (Flow rate - 6 LPM)
Supply and fixing C.P. brass long nose Sink cock with Swinging Casted Spout of Jaquar make Model No. CON-349KNM / Parryware / Hindware or approved equivalent make (Table mounted Model) with complete fittings of approved make. (Flow rate - 6 LPM)
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Supply & fixing of Electronic Auto level controller with Providing and fixing electronic type level indicator for water tanks mounting in panel with the following features, level display, alarm when water level is low or high, full range from one level to four level display and manual reset for alarm etc. Sensor should be non ferrous type (Non corrosive type). Display and control panel to be kept in the Pump room
Supply & fixing of Electronic Auto level controller cables with electrical wiring conduit supports from wall and ceiling probs and all other accessories complete as required 2Cx1.5 Sqmm Cable with MS Conduit
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door , window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With frosted glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Supplying, fabricating and fixing anodised aluminium box louvers using required sections, anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 25 conforming to IS: 11857-1986, including fixing with steel anchors , shoe brackets, SS hardware, silicon sealant, labour charges etc all including overhead and contractors profit for finished d items of work and as directed by Engineer-in-charge
Basement Water proofing Providing and Installing 2mm thick synthetic membrane of plasticized PVC of (BASF / Sika / Fosroc / MYK Arment/ Mapei) , manufactured by co-extrusion process with signal layer of light green on upper surface and lower surface in black colour. Membrane shall be laid on a correction / slippage layer of Non-woven geotextile of 500GSM, which shall be laid over float finished PCC and a layer of 300 GSM, PP Geo-textile shall be laid above the PVC Membrane as a protection layer. Membrane shall have the following properties such as Thickness UNI EN 1849 -2 : 2.0 mm, Specific weight UNI EN 1849 -2 : 2.600 kg/m2, Ultimate Tensile strength UNI EN ISO 527-3, Transverse : 16.4 N/mm2 ( -1.5 N/mm2 ), Machine direction : 16.7 N/mm2 ( -1.5 N/mm2 ), Elongation UNI EN ISO 527-3, 310%, Puncture resistance DIN 16726 - 5.12 : > 1100 mm, Hydrostatic pressure resistance ( 6 hours at 5 bar) UNI EN 1928 meth.B, Waterproof, Resistance to static punching (CBR) UNI EN ISO 12236 : > 2300 N Resistance to oxidation UNI EN 14575 - Tensile strength variation :` < 25% Root resistance CEN TS 14416 : No pentration •UNI EN ISO 9001 & UNI ENI 14001 certified plant. Membrane shall be continued along the side of the raft vertically upto a height of 50mm down from the top of the raft and terminated at the PVC waterstop laid along the skin of the retaining wall. Double seam welding of PVC waterproofing membrane shall be done along the lap joints where ever possible and pressure testing of the same to 2 bars up to 10 minutes max. Provision of Compartmentalization by welding PVC with water stop at all construction joints and at strategic locations to make a compartment of around 250sqm each.\ Providing and Laying of injection Tube at the strategic location on the waterstop. Provision of suitable QA/QC system for the entire waterproofing works and installation of PVC water stop at all construction joints and at strategic locations to make compartments. Note: Rate quoted shall be for supply and application of the above system including supplying and laying of geotextile below and above the membrane as specified. For horizontal surfaces
Same as item No 245 above but for vertical surfaces
Waterproofing of Podium (Landscape areas) Waterproofing treatment with two-component solvent free Pure Polyurea. All substrates, whether new or old, must be solid, clean, dry and free of all traces of oil, grease, old paint, rust, mould and any other material which could affect adhesion. The pullout strength of the concrete shall be >1.5 Mpa & the moisture content of the substrate should be < 4%. Supply & application of two-component,heavy duty, solvent-free, spray applied, pure-polyurea based waterproof coating membrane of Mapei/BASF/SIKA/Fosroc/MYK Arment or equivalent applied in situ using a high-pressure, bi-mixer type pump to form a tough waterproof membrane of 1.5mm thickness. The waterproofing membrane system, a multi-layered system comprising of a series of substrate sealers, primers, waterproofing membranes and protective top-coats. The cleaning and preparation of the substrate to which the polyurea is sprayed must be carried out thoroughly to leave a sound base for the application. Concrete and other cementitious substrates must have a minimum pull off strength of >1.5 N/mm2. Any laitance present on the surface must be removed mechanically. Release oil and other contaminants which may impair adhesion must be removed prior to the application of the primer, the system shall consist of Epoxy based fillerized, broadcasted with Quartz sand(0.5) for mechanical grip. Thus applied Polyurea membrane shall exhibit a Elongation of >300%, Tensile strength of >20 N/mm2 and Tear resistance of >80 N/mm, Shore Hardness (A) of 90 or more and quick reaction of product when applied by spray: gel time at +70°C < 6 seconds. Protection Layer: Providing and laying a protection layer of 300 gsm Polypropylene geotextile over the spray applied membrane to protect against any damage during the placement of weathering / slope course, concrete slope screed etc Note:The application of all the above systems shall be carried out only by the manufacturer's approved applicator. Item includes provision of a QA/QC procedure etc., all complete as per manufacturer's specification and as directed by the Engineer- in-charge. Rate for supply and application of above system including termination of membrane, cost of materials, lead and lift, labour for application etc all complete.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively), VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifications and as approved by Engineer-in-Charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc., washing with water all complete. The contractor shall give guarantee for the perfomance of SRI and also the durabitity of coating, all complete as per direction of Engineer-in-Charge.
Grading roof for water proofing treatment with ement concrete 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.
Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear metre (expansive nature) for construction joints treatment of RCC structure, such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running metre. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage.
Wet areas Waterproofing Providing and applying two component acrylic polymer modified cementitious flexible waterproofing (BASF / Sika / Fosroc / MYK Arment) of approved brand over wet areas . The system shall include base preparation of cleaning, brushing and removal of flacky materials, grouting the porous area with cementitious grout, proper coving between slab and wall junctions and applying water proof material in two coats @ 0.75kg/M2/coat. Coating shall be done on the entire horizontal surface. and shall be continued vertically 300 mm above the wall level,etc., complete as per manufacturer's methodology and specification.(Plan area only shall be measured for payment.)
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminium sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places. Note:- 2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories (1) Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr (2) Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml. (3) Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml (4) Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm (5) Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test. Tests to be conducted on site. (6) Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in?Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Supply, Transportation, Installation, Testing and Commissioning of VRV/VRF/High COP minimum of one/Two/Three Out door units comprising of DC scroll/DC Twin Rotary, Inverter driven compressor, Air cooled condenser operation on R-134A/410A Refrigerant gas and on 415V, 50Hz, 3 phase AC supply. The multiple compressors offered shall have independent refrigerant circuit, also shall cut off automatically in part load condition. The unit shall have microprocessor controls. The out door units shall be installed on the space alloted in the drawings and scope shall include all supports for the out door units. Units shall be factory assembled and only the refrigerant piping shall be carriedout at the site. The noise levels for the out door unit shall be less than 65db(A). The price shall include the vibration isolator, all types of outdoor units connection piping (T-Shape and Y-shape) kits in pair excluding refrigerant pipe and refregirent gas for the following capacities 36 hp VRF ODU FOR Ground Floor
Same as item No. 260 above but 66 hp VRF ODU FOR 3 rd Floor
Same as item No. 260 above but 52 hp VRF ODU FOR 4 th Floor
Same as item No. 260 above but 48 hp VRF ODU FOR 5 th Floor
Same as item No. 260 above but 82 hp VRF ODU FOR 6 th Floor
Same as item No. 260 above but 92 hp VRF ODU FOR 7 thFloor
Same as item No. 260 above but 92 hp VRF ODU FOR 8th Floor
Same as item No. 260 above but 74 hp VRF ODU FOR 9 th Floor
Same as item No. 260 above but 80 hp VRF ODU FOR 10th Floor
Supply, Installation, Testing and Commissioning of ceiling mounted ductable type indoor units operating on single phase 220V, 50Hz AC supply comprising of prefilter fan,density&population sensor, section with low noise fan, multispeed motor coil section with DX coil, outer cabinet, drain water lift- Up mechanism, insulation, including all types of Refrigerant pipe joint kit connections, fresh air intake, with cordless remote controller etc., for the following capacities . as also an under frame of Gi 10 HP DSU - 3400 cfm
Same as item No. 269 above but 8 HP DSU - 3000 cfm
Same as item No. 269 above but 6 HP DSU - 2200 cfm
Same as item No. 269 above but 5 HP DSU - 1600 cfm
VRF Indoor units with cooling coils, fans, controls drain pumps control boxes and presentable plastic insulated casing and FA connections etc., etc to sizes as under:- 1 HP - 4 way compact cassette
Same as item No. 273 above but 2 HP - 4 way compact cassette
Same as item No. 273 above but 3 HP - 4 way compact cassette
Same as item No. 273 above but 4 HP - 4 way compact cassette
Same as item No. 273 above but 1 HP - 1 way compact cassette
Same as item No. 273 above but 2 HP - 1 way compact cassette
Same as item No. 273 above but 3 HP - 1 way compact cassette
Same as item No. 273 above but 4 HP - 1 way compact cassette
Supplying and Installing Refrigeration piping with Nitrile rubber (min 12mm thick) with Al foil faced insulation, supports etc., etc. 7 sets to complete the system. (length to be based on pipe routing as in drawing) (all pipes to be laid in a 450mm / 300mm / 150mm wide - GI preforted cable Tray 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Same as item No. 281 above but 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Same as item No. 281 above but 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
Same as item No. 281 above but 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
Same as item No. 281 above but 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Same as item No. 281 above but 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
Same as item No. 281 above but 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
Same as item No. 281 above but 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
Same as item No. 281 above but 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19mm thick insulation
Same as item No. 281 above but 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Same as item No. 281 above but 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Same as item No. 281 above but 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Same as item No. 281 above but 44.5 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supplying and Installing Drain piping – UPVC heavy duty 25mm diameter with expanded Nitrile rubber insulation (6mm) – length to be as in drawing (generally along the ref piping)- 7 set
Supplying and Installing Internal wiring, controls, switches knobs and suitable display face plates including for cordless remote for all the indoor units listed above – (7 Sets) 54 16amps 3 pin plug and shocket
Supplying and Installing Internal wiring, controls, switches knobs and suitable display face plates including for cordless remote for all the indoor units listed above – (7 Sets) 2.5 sq. mm ISI marked, FRLS PVC insulated, single core copper conductor cable with MS Conduit
Supplying and Installing Miscellaneous item like FA intake with VCD & fire damper, supports mounts, painting of equipment, etc. size as below Big -600 x 200
Supplying and Installing Supply air ducting out of GSS to areas as complete with sponge Neoprene / Rubber gaskets etc., etc. for FA, Unit plenum and Toilet exhaust 24 gauge
Same as item No. 298 above but 22 gauge
Same as item No. 298 above but 20 gauge
Supplying and Installing Acoustical insulation of ducts with 25 mm thick fibreglass crown 150 and perforated aluminium facing – 24 gauge thick - sq.m
Supplying and Installing Ducting insulation (Thermal) with 25 mm foamed Nitrile rubber insulation (Black seamless finish).
Supplying and Installing RA / SA outlets of extruded aluminium with powder coating - disc valves as used for FA. 400 x 300 - FA L (m - 10 Nos)
Supplying and Installing RA / SA outlets of extruded aluminium with powder coating - disc valves as used for FA. 600 x 600 - SA diffuser -
Supplying and Installing RA outlets of extruded aluminium with powder coating 600 x 600 RA Diffuser - whisker type
Supplying and Installing RA outlets of extruded aluminium with powder coating RA Grille Continuous
Supplying and Installing Miscellaneous items like gas / oil – supports for pipes cables etc etc. Gas
Supplying and Installing Miscellaneous items like gas / oil – supports for pipes cables etc etc. Cable tray support (Kg of steel)
Supplying and Installing Mounting ms stand with vibration isolation pads for the condensing unit out of 65 x 65 x 6mm angles to keep the unit 600 clear of the ground - duly painted with 2 coats of epoxy paint.
Toilet air outlets of extruded aluminium with powder coating disc valves used for FA and exhaust 150Ø Ex valves
Flexble ducts of gi to connect to the above exhaust valves into the rectangular ducts each to be 1000mm long - complete with proper edge fasteners, C clips etc etc.. 150Ø
Toilet exhaust fans - in line centrifugal fans to ratings as below: 500 @ 25mm SP(For toilet ex duty)
Same as item No. 312 above but 600 @ 25mm SP(For toilet ex duty)
Same as item No. 312 above but 800 @ 25mm SP(For toilet ex duty)
Same as item No. 312 above but 1000 @ 25mm SP(For toilet ex duty)
Same as item No. 312 above but 1600 @ 25mm SP(For toilet ex duty)
Centrifugal exhauster (cabinet type) with 3 phase external rotor motor (direct coupled) fan, DOL starter, drive and guard - all mounted on a common casing directly fixable to the wall / ceiling - fan size to be - (8000 @ 50mm SP)
cabinet type or axial for stair case pressurization with three phase external rotor motor (direct coupled) fan, DOL starter, drive and guard - all floor mounted supports- (22000 cfm @ 70mm SP)
Supply, installation, testing & commissioning of smoke spill Axial fans for the following capacities complete with TEFC motor,mounting bracket, Gravity louver, 900 mm long silencers at inlet with all supports, etc. The fan and motor shall be suitable for VFD operation. The fans shall be installed with spring vibration isolator or cushy foot mounting as to avoid transmission of vibration. The fan and motor shall be suitable for smoke evacuation and shall be rated for 250 Deg C for 2 hours fire with stand capacity with casing made of GI Sheet, motor, with impeller (Hub and blades) shall be constructed of die cast aluminum alloy. Impeller should have aerodynamic profile, Casing made of Galvanized steel. Direction of discharge and rotation position shall be as per the job requirement Please refer technical specification for further data. The noise level of the fans at rated speed shall not exceed 70dBA at 1m distance with inlet 20000CFM for Basement-1 exhaust (25 mm Total Static Pressure). Maximum sound power level at source (LWA) -80 DBA.
Same as item No. 319 above but 16000 CFM for Basement-1 Fresh air fan (25 mm Total Static Pressure). Maximum sound power level at source (LWA) -80 DBA.
Same as item No. 319 above but SITC of Induction 350dia JET VENT fans with motor (suitable for 300 Deg C for 2 Hours, 2 silencers, 2 bird screen, 1 bell mouth, mounting legs 2 Nos and fixing bolts.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC (2.0 mm thickness) conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC (2.0 mm thickness) conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Conduit Supplying and fixing of following sizes of PVC conduit (2.0 mm thickness) along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Conduit Supplying and fixing of following sizes of PVC conduit (2.0 mm thickness) along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 32 mm
10 Watt Recessed LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc. (refer catalogue no : Phillips DN295B LED10S-6500 PSU WH , Panasonic PDLM12107 or its equivalent)
10/12 Watt Surface mounted LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc. (refer catalogue no : Phillips SM250C LED12S- 6500 PSU WH , Panasonic PDLM10106P or its equivalent)
18/20 Watt Surface mounted LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of powder coated CRCA with high efficiency diffuser with driver, accessories wiring etc. (refer catalogue no : Phillips SM251C LED20S- 6500 PSU WH , Panasonic PDLM10206P or its equivalent)
20 Watt Recessed LED Downlighter with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc.(refer catalogue no : Phillips DN195B LED20S-6500 PSU WH S2, PanasonicPDLM12207 or its equivalent)
20W,2000 lumens T8,1200mm length LED retrofit tube light with aluminium anodised body, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322. (refer catalogue no : Phillips BN308C LED20S-6500 L60 PSU WH, Panasonic PBTM12208 or its equivalent)
IP65 20W,2000 lumens T8,1200mm length LED retrofit tube light with aluminium anodised body, input voltage AC 220 - 260 Volts with PF>0.9, Surge protection: 2KV,THD<10%, with inbuilt driver and frosted cover CCT: 3000K - 5700K, minimum CRI>70, .etc., complete as per IS 10322 (refer catalogue no : Phillips WT201C LED20S-6500 PSU L120, Panasonic PBTM05207 or its equivalent)
30/36 Watt Recessed LED 2 x 2 panel with minimum luminaire system efficacy of 100 lm/w having a color temperature of 5700K and housing should made up of powder coated CRCA with high efficiency diffuser with driver, accessories wiring etc.(refer catalogue no : Phillips RC380B LED36S -6500 G4 L60 W60 PSU OD, Panasonic PBLM10367 or its equivalent)
10 Watt Bulkhead LED light fixture with minimum luminaire system efficacy of 70 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc.(refer catalogue no : PhillipsWT202W LED6S CW PSU S2 PC, Panasonic PBHM01107 or its equivalent)
14 Watt Decorative Mirror Light LED light fixture with minimum luminaire system efficacy of 70 lm/w having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc (refer catalogue no : JaguarKWB-CHR-MB48012A or its equivalent)
Supply, installation, Testing and Commissioning of Recessed 4' Linear Led light fixture with minimum luminaire system having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc (Makes : Phillips/Panasoninc/Wipro or its equivalent)
Supply, installation, Testing and Commissioning of 8' Linear Led light fixture with minimum luminaire system having a color temperature of 5700K and housing should made up of pressure die cast aluminium with high efficiency diffuser with driver, accessories wiring etc (Makes : Phillips/Panasoninc/Wipro or its equivalent)
Supply, installation, Testing and Commissioning of twin aviation obstruction light with LED aviation light with Timer and required mounting arrangments and as per regulation with latest amendments as per direction of Engineer-in- Charge. (Makes : Phillips/Bajaj/Wipro or its equivalent)
Supply, installation, Testing and Commissioning of PIR ceiling motion sensor 360ø infrared detection, range 8 m Recommended fixing height: 3.0 mtr 3-wire with neutral IP 41 Light level threshold: 1 to 1000 lux Adjustable time delay: 5 s to 30 min Consumption: 0.4 W on standby Optimum distance between 2 sensors: 6 m Fixes directly to a false ceiling with mounting claws (included) or installed in a Batibox box, depth 50 mm Can be surface mounted on ceiling using accessory wirings etcc makes : Legrand/Bajaj/Havells.
Ceiling & Exhaust Fan Supply, Transportation of energy efficient fan, 1200 mm sweep, aluminium body,consuming 28 W, BEE 5 star rated, ceiling fan with Brush Less Direct Current(BLDC)motor, class of insulation: B,3 no's blades, 30 cm long down rod, 2 no's canopies, shackle kit, safety rope, copper winding, Power Factor greater than 0.90,Service Value (CMMAV) greater than 8.5, Air delivery minimum 235 CMM, 350 RPM( tolerance as per IS:374-2019), THD less than 10%. with remote or compatible to electronic step type regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230V, 50 HZ, single phase AC supply, earthing etc., including regulator and modular plate and cover all standard accessories etc., complete.
Supply of following sizes of 450 mm Sweep (900 RPM) Heavy duty Exhaust fan with Louver suitable for operation on single phase 230 Volt AC 50 Hz supply complete with all fixing accessories as required.
Power Sockets Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supply and fixing of Prewired Bank 3 Nos of 6/16A, Single Phase Universal Socket controlled by1No-16Amps single pole switch and with 8 module surface box (wrapround) and front plate fixing including all labour charges etc., complete.
Supply and fixing of 1Nos of 6/16A, Single Phase Universal Socket controlled by1No-16Amps single pole switch and with 3 module surface box (wrapround) and front plate fixing including all labour charges etc., complete.
Supplying and fixing 20A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supply, Erection, Installation Testing and Commissioning of 250A TPN, MCCB totally enclosed in MS frame coated boxes with metal housing.The erection rate shall include supply of angle iron framework and fixing accessories such as grip bolts/ grouting /welding to steel structures etc.(Makes : Schnieder ,Legrand ,L&T)
Supply, Erection, Installation Testing and Commissioning of 63A TPN,Isolator totally enclosed in Outdoor Type Weatherproof MS frame coated boxes with metal housing.The erection rate shall include supply of angle iron framework and fixing accessories such as grip bolts/ grouting /welding to steel structures etc.(Makes : Schnieder ,Legrand ,L&T)
Supply, Erection, Installation Testing and Commissioning of 63A TPN, MCCB totally enclosed in MS frame coated boxes with metal housing.The erection rate shall include supply of angle iron framework and fixing accessories such as grip bolts/ grouting /welding to steel structures etc.(Makes : Schnieder ,Legrand ,L&T)
Runs of Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in exisitng surface/ recessed conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Runs of Mains Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in exisitng surface/ recessed conduit as required. 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire
DISTRIBUTION BOARD Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board (IP-43), 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 8 way (4 + 24), Double door for Lighting DB and Emergency Lighting DB
DISTRIBUTION BOARD Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board (IP-43), 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 8 way (4 + 24), Double door for Power DB
DISTRIBUTION BOARD Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board (IP-43), 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 8 way (4 + 24), Double door for UPS DB
Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCCB V-TPN distribution board (IP-43), 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 12 way (4 + 36), Double door for Emergency V-TPN DB
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A 4P MCB incomer for Lighting DB
Supplying and fixing following rating, four pole, 415 V,MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A 4P MCB incomer for Power & Ups DB
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A 4P MCB incomer for Emegency Lighting DB
Supplying and fixing following rating, three pole, 415 V,MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A TP MCB incomer for UPS V-tpn Outgoings
Supplying and fixing following rating, three pole, 415 V,MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32A TP MCB incomer for Emergency V-tpn Outgoings
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A DP RCCB for Lighting DB
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A DP RCCB for Power & UPS DB
Supplying and fixing 5 A to 32 A rating, 240 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6-32A MCB outgoings for Lighting,Power, UPS DB & Emergency DB Outgoings.
Supplying and fixing of 8 way Cable End Boxes (IP 43) suitable for Lighting,Ups,Emergency and Power TPN DBs as MCB distribution board, 240 volts, on surface/ recess, complete with testing and commissioning etc. as required.
Supplying and fixing of 12 way Cable End Boxes (IP 43) suitable for Emergency Lighting,Ups VTPN DBs MCCB distribution board, 240 volts, on surface/ recess, complete with testing and commissioning etc. as required. .
LT CABLES : Supply and transportation of following XLPE insulated, 1100V grade armoured/flexible aluminium/copper cable as per specification confirming to IS:7098 (Part - I).1554-I laid in trench & existing cable tray including cost and conveyance of all materials and accessories with labor charges etc., 3.5C x 300 SQ.MM AL. AR. CABLE NOTE : Contractor required to take measurement before procuring the cables as per site condition.
Same as item No. 365 above but 3.5C x 240 SQ.MM AL. AR. CABLE
Same as item No. 365 above but 3.5C x 95 SQ.MM AL. AR. CABLE
Same as item No. 365 above but 3.5C x 95 SQ.MM CU FLX. CABLE
Same as item No. 365 above but 1C x 95 SQ.MM CU. FLX. CABLE
Same as item No. 365 above but 3.5C x 70 SQ.MM AL. AR. CABLE
Same as item No. 365 above but 3.5C x 25 SQ.MM AL. AR. CABLE
Same as item No. 365 above but 4C x 16 SQ.MM CU. FLX. CABLE
Same as item No. 365 above but 4C x 10 SQ.MM CU. FLX. CABLE
Same as item No. 365 above but 4C x 6 SQ.MM CU. FLX. CABLE
Same as item No. 365 above but 4C x 4 SQ.MM CU. FLX. CABLE
Same as item No. 365 above but 4C x 4 SQ.MM AL .AR. CABLE
Same as item No. 365 above but 3C x 4 SQ.MM CU. FLX. CABLE
Same as item No. 365 above but 3C x 2.5 SQ.MM CU. FLX. CABLE
LT CABLES TERMINATIONS : Supply and making one end termination with heavy duty double compression brass gland as per BS 6121:2005 ,IP 66 complete,SIBG type, heavy duty Alluminium/copper lugs duly crimped with crimping tool, PVC tape etc for following size of Armoured/flexible PVC insulated & PVC sheathed/ XLPE aluminium/Copper conductor cable of 1100 volt grade as required of size including cost and conveyance of all materials and accessories with labour charges etc., complete. 3.5C x 300 SQ.MM AL. AR. CABLE
Same as item No. 379 above but 3.5C x 240 SQ.MM AL. AR. CABLE
Same as item No. 379 above but 3.5C x 95 SQ.MM AL. AR. CABLE
Same as item No. 379 above but 3.5C x 95 SQ.MM CU FLX. CABLE
Same as item No. 379 above but 1C x 95 SQ.MM CU. FLX. CABLE
Same as item No. 379 above but 3.5C x 70 SQ.MM AL. AR. CABLE
Same as item No. 379 above but 3.5C x 25 SQ.MM AL. AR. CABLE
Same as item No. 379 above but 4C x 16 SQ.MM CU. FLX. CABLE
Same as item No. 379 above but 4C x 10 SQ.MM CU. FLX. CABLE
Same as item No. 379 above but 4C x 6 SQ.MM CU. FLX. CABLE
Same as item No. 379 above but 4C x 4 SQ.MM CU. FLX. CABLE
Same as item No. 379 above but 4C x 4 SQ.MM AL .AR. CABLE
Same as item No. 379 above but 3C x 4 SQ.MM CU. FLX. CABLE
Same as item No. 379 above but 3C x 2.5 SQ.MM CU. FLX. CABLE
Cable trays Supplying and installing following size of perforated with powder coating G.I cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors,tees,vertical/horizontrol bends, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required 150 mm width X 50 mm depth X 2.0 mm thickness with cover
Same as item No. 393 above but 250 mm width X 50 mm depth X 2.0 mm thickness with cover
Same as item No. 393 above but 300 mm width X 50 mm depth X 2.0 mm thickness with cover
Same as item No. 393 above but 450 mm width X 50 mm depth X 2.0 mm thickness with cover
Same as item No. 393 above but 600 mm width X 50 mm depth X 2.0 mm thickness with cover
Same as item No. 393 above but 800 mm width X 50 mm depth X 2.0 mm thickness with cover
Raceways & Junction Box Providing and laying 1.6 mm thick pregalvanized GI factory fabricated raceways of the following sizes including 2 mm thick GI covers, providing knock out holes and all required fixing accessories including 8 SWG GI earth wire complete as required including floor /wall supports, bends, access boxes and tap off boxes as per specification and cross over as per site requirement. Note:- Blue & Orange colour shall be considered for Power & Data raceway respectively. The item shall include the cost of chipping, cutting the floor for laying the raceway and making good the finish including chicken mesh complete as required as per site requirement. 150 mm wide x 40 mm deep raceway
Same as item No. 399 above but 200 mm wide x 40 mm deep raceway
Same as item No. 399 above but 300 mm wide x 40 mm deep raceway
Providing and fixing of 350 x 350 x 40 mm deep (Nominal size) floor junction box including providing 2 mm thick GI cover required as per specification
Providing and fixing of 250 x 250 x 40 mm deep (Nominal size) floor junction box including providing 3 mm thick GI cover required as per specification
Providing and fixing of 150 x 150 x 40 mm deep (Nominal size) floor junction box including providing 3 mm thick GI cover required as per specification
Supply & fixing of Lan socket outlet of approved make and design in 1.2 mm thick GI box long with modular base & cover plate for modular switches in recess etc. as required.earthing complete in all respect.
Supply, installation, testing and commissioning of following Category 6, IDC network switch with fibre port prepackaged with wiring block with legs with legs insert labels, label holders, jumper troughs, metal back panel, duct assembly, screws, washers and an instruction sheet for termination of incoming pairs. 48 port gigabit fully managed network switch panel
Supply, installation, testing and commissioning of following Category 6, IDC patch panel prepackaged with wiring block with legs with legs insert labels, label holders, jumper troughs, metal back panel, duct assembly, screws, washers and an instruction sheet for termination of incoming pairs. 48 port patch panel
Supply, installation, testing and commissioning of following Category 6, IDC network switch with fibre port prepackaged with wiring block with legs with legs insert labels, label holders, jumper troughs, metal back panel, duct assembly, screws, washers and an instruction sheet for termination of incoming pairs. 24 port gigabit fully managed network switch panel
Supply, installation, testing and commissioning of following Category 6, IDC patch panel prepackaged with wiring block with legs with legs insert labels, label holders, jumper troughs, metal back panel, duct assembly, screws, washers and an instruction sheet for termination of incoming pairs. 24 port patch panel
Supply installation testing and commisioning of 16 port fiber patch panel loaded(LIU) with couplers etc complete)
Supply installation testing and commisioning of SFP Module for optical fiber connectivity.
Supply , Installation, Testing and Comissioning of Wall mounted Communication rack in two sections viz rear wall mount Section and hinged front section with glass doors, swing handles ,lock , Top and Bottom Cable entries,Supports for mounting rack on wall , Cable managers, Fan tray with 2 x 230 Volt fans, Equipment mounting hardware, wire managers , Levelers with required 16A/5A power supply box for supplying power to hubs, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable, Blank panels , sliding shelves etc. 4U Rack
Supply , Installation, Testing and Comissioning of Wall mounted Communication rack in two sections viz rear wall mount Section and hinged front section with glass doors, swing handles ,lock , Top and Bottom Cable entries,Supports for mounting rack on wall , Cable managers, Fan tray with 2 x 230 Volt fans, Equipment mounting hardware, wire managers , Levelers with required 16A/5A power supply box for supplying power to hubs, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable, Blank panels , sliding shelves etc. 6U Rack
Supply , Installation, Testing and Comissioning of Wall mounted Communication rack in two sections viz rear wall mount Section and hinged front section with glass doors, swing handles ,lock , Top and Bottom Cable entries,Supports for mounting rack on wall , Cable managers, Fan tray with 2 x 230 Volt fans, Equipment mounting hardware, wire managers , Levelers with required 16A/5A power supply box for supplying power to hubs, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable, Blank panels , sliding shelves etc. 9U Rack
Supply , Installation, Testing and Comissioning of Wall mounted Communication rack in two sections viz rear wall mount Section and hinged front section with glass doors, swing handles ,lock , Top and Bottom Cable entries,Supports for mounting rack on wall , Cable managers, Fan tray with 2 x 230 Volt fans, Equipment mounting hardware, wire managers , Levelers with required 16A/5A power supply box for supplying power to hubs, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable, Blank panels , sliding shelves etc. 15U Rack
Supply installation testing and commisioning of 4 pair 23AWG Cat6 UTP ,2mtr/7 ft flexible ,double ended patch cords along with 2 nos of RJ 45 connectors with strain relief boots Compatible to T568A,T568B specifications including making connections to information outlets
Supply installation testing and commisioning of 4 pair 23AWG Cat6 UTP ,1mtr/3.2 ft flexible ,double ended patch cords along with 2 nos of RJ 45 connectors with strain relief boots Compatible to T568A,T568B specifications including making connections to information outlets
Supply, laying, testing & commissioning of Cat-6 cable of approved make for Data in existing conduit/raceways complete in all respect as required upto Data Server system.
EPABX System(Telephone) Supply & fixing of Telephone socket outlet of approved make and design in 1.2 mm thick GI box long with modular base & cover plate for modular switches in recess etc. as required.earthing complete in all respect. (which support 16 digital extensions, 224 analog extensions.)
Supply, laying, testing & commissioning of Cat-6 cable of approved make for Data/Voice system in existing conduit complete in all respect as required upto EPBAX//Data Server system. (which support 16 digital extensions, 224 analog extensions.)
Supply, Installation, Testing and Commissioning of high end IP Based digital Telephone (EPABX) system complied with following specifications: > IP @ Core, PCM/TDM switching, Non-blocking, > Must Support PRI, E1, Analog Junctions > Must Support PC Console, > Must support Mobile SIP (Android and I O.S) > Must support Voice Mail > Must support Card based GSM > Inbuilt Call Details Software with search engine software > 8 Analog Trunks > 1 PRI Trunk module, VOIP card > 16 Digital Extensions > 224 Analog Extensions > 1 Digital Key Phone with minimum 16 Keys (Must work only on 2 wires) > Inbuilt hot standby for CPU and PSU. > Compatibility to run on DC -48v source. > Expandable to 400 Ports wired or more at extra cost
Supply Installation Testing and Commissioning of IP Phone (40 Key) Backlit keypad Hands-free, full duplex, Headset support Easy to use soft keys/LCD prompts, Directory dialling, Navigation wheel, Call history, Backlit LCD screen, Bluetooth support
Supply Installation Testing and Commissioning of Server Rack 15 U
Supply Installation Testing and Commissioning of 48 Port Patch Panel
Supply Installation Testing and Commissioning of 24 Port Patch Panel
Supply Installation Testing and Commissioning of Fullymanaged Gigabit Network Switch 48 Port with fibre port
Supply Installation Testing and Commissioning of Fullymanaged Gigabit Network Switch 24 POE Port with fibre port.
Supply,Laying,installation,testing and commisioning Indoor, steel tape armoured multimode[62.5/125um ] glass Fiber Optic Cable as per latest ammendments of TIA /EIA 568B.3 , GR 20 CORE/ UEC 794-1/ EN 187000 Standards in existing MSPVC Conduits/ hume pipe including making terminations to active passive equipments with ferruling at both ends for identification with necessorry tools for Terminations and testing required
Providing independent earthing by exacavating a pit to a depth of 2.25Mtr in all soils as per size specified in the data for Sophisticated Electronic equipment with 600mm x 600mm x 3.15mm thick copper plate rigidly fixed to 19mm dia 'B' Class G.I Pipe of 2.5Mtr lengthwith funnel as per National Electric Code and earth connection from electrode GI strip of 40mm x 5mm x 200mm length to be bolted withnut bolts to G.I.pipe including 25mm x 3mm copper strip of 6Mtrs length connected from plate to GI strip including filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder from the bottom of the pipe and providing CC / Brick massonry chamber 450mmX450mmX400mm and covered with R.C.C. Slab including all accessories and labour charges etc complete as per IS specification 732/1982 (Part II).
Providing independent earthing for Important equipment with 40mm dia 'B' class 2.5m long G.I pipe and 19mm dia 'B' class G.I pipe of 0.3mtr. long connected with reducer providing G.I funnel with mesh enclosed in C.C/ brick massonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder from the bottom of the pipe giving earth connection from electrode through G.I strip of 40 x 6mm x 200mm length with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II)
Supply and fixing of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305)
Supply and fixing of 4Mtr Vertical air terminal with accessories:Providing of Air terminals as per IS-IEC -62305 part-3 16mm rod tapered to 10 mm aluminium rod : Meets the technical specification according to DIN EN 50164-2 (VDE 0815 part 202). Meets the requirement of VDE0185/305(IS/IEC 62305) 4Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load.
Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. OBO Type No. 165 MBG 8-10 ( 5218 70 0)
Providing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218 92 6 )
Supply and fixing of Roof conductor holder for parapet- Polyamide Conductor holder: With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder. Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance
Supply and fixing of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts .
Supply and fixing Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2nos/expansion piece ).
Accessories : System consist of Fang Fix with base and clamp, on the top air terminal is erected. OBO Type No. F-FIX 16 ( 5403 20 0 ).
Fang fix clamp made of SS, lightning tested for 100 KA 10/350 micro sec waveform.16 KG stone of 365 mm diameter, high level of stability.Quick and easy mounting of interception rod using anchors.Concrete, frost-resistant, can be stacked.OBO Type No. F-FIX S16 I ( 5450 08 0 )
Supply of conductor holder for ridge sheet as specified in drawing , Bottom section stainless steel (V2A) with Ø 8.5 mm slot made of Conductor holder of stainless steel (V2A) @ every 1mtr distance. OBO Type No. 159 VA-V (5217 07 5)
Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer OBO Type No. 271 8- 10 ( 5317 40 1 )
Enclosure for Test joint: RoHS Complied, IP66, 6mm², 500V, IK08, UV resistant, Halogen free Thermoplastic junction box ,installation of cables either directly through the 7 x M25 seals, polypropylene,Light grey. Junction box T 100, plug-in seal Clear internal dimensions: 136x102x57 mm OBO TYPE : T 100 (2007 077)
Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. OBO Type No. LSC I+II ( 5091 72 2 )
Supply and fixing of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor shall be of Hot Dipped & Cross sectional area of 90mm square According to DIN EN 50164-2 (VDE 0185 part 202) Meets the requirement of VDE0185/305(IS-IEC 62305) Zinc coating: 500 g/m square (Approx:70 micron coating) Should be tested and used exclusively for lightning protection earthing system and ring equipotential bonding.
Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. OBO Type No. 255 FL30 FT (5314 53 4 )
Providing of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts.OBO Type No. 166 LS 70 (5226570)
Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. OBO Type No.356 50 ( 2360 05 5 )
Supply and laying of CPRI tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 & is provided with universal clamp made of SS to connect rod with flat conductor . Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested . The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system
Supply, Installation, Testing & Commissioning of IP 2MP Mini Dome Network Camera , UL Listed, with all mounts and accesories as required. (PELCO model No. IMP231-1ERS or equivalent )
Supply, Installation, Testing & Commissioning of IP 2MP Bullet Camera , UL Listed, with all mounts and accesories as required. (PELCO model No. IBP232-1ER or equivalent )
Supply, Installation,Testing and Commissioning of 64 bit NVR Record and monitor up to 64 IP channels at 1920 fps @ 4CIF/VGA or 1920 fps @ 720p HD or 1920 fps @ 1080p (4 Mbps bitrate) HD. Network bandwidth/throughput supported per NVR.
Supply of Surveillance HDD of capacity 8TB Supporting for upto 64 cameras per drive with performance class of 5400/7200 RPM Class (for backup of 90 days) (Make: WD & Warranty 3 years)
Supply , Installation, Testing and Comissioning of Wall mounted Communication rack in two sections viz rear wall mount Section and hinged front section with glass doors, swing handles ,lock , Top and Bottom Cable entries,Supports for mounting rack on wall , Cable managers, Fan tray with 2 x 230 Volt fans, Equipment mounting hardware, wire managers , Levelers with required 16A/5A power supply box for supplying power to hubs, fans etc along with earth continuity kit, Mcb, indicator, moulded power supply cable, Blank panels , sliding shelves etc. 4U Rack
Same as item No. 453 above but 6U Rack
Same as item No. 453 above but 15U Rack
Supply,Installation of Gigabit 24 port Switch with fibre port IP multicast snooping and data-driven IGMP support and with minimum two 1000baseT RJ45 uplink ports and two 1000 baseT Fiber uplink ports and enclosure/rack for switch with mounting supports and all accessories. (183/190W or above switches) with high performance & capable of enhancing any type of business network.
Supply, Installation and commisioning of Gigabit 24 port PoE Switches with IP multicast snooping and data-driven IGMP support and with minimum two 1000baseT RJ45 uplink ports and twp 1000 baseT Fiber uplink ports and enclosure/rack for switch with mounting supports and all accessories. (190W or above switches) with high performance & capable of enhancing any type of business network.
Same as item No. 457 above but 8 port
Supply,laying ,testing and commisioning of 4-pair, Cat6 Solid to support 1Gbps with Cross (+) filler pair seperator & PVC sheath 23 AWG, STP Cable , Meets or exceeds ANSI/TIA- 568-C.2 and UL Listed &RoHS Compliant in the existing raceways /pvc conduits including making connections to information outlets and patch panels with ferruling at both ends for identifiation with necessary tools for punching stripping crimping and testing required etc., complete
Supply,laying ,testing and commisioning of 4-pair, Cat6 Solid to support 1Gbps with Cross (+) filler pair seperator & PVC sheath 23 AWG, UTP Cable , Meets or exceeds ANSI/TIA- 568-C.2 and UL Listed &RoHS Compliant in the existing raceways /pvc conduits including making connections to information outlets and patch panels with ferruling at both ends for identifiation with necessary tools for punching stripping crimping and testing required etc., complete
Supply of RJ45 modular plug supports 4 twisted pairs,meet wiring scheme with 50 micro-inch gold plating over 50 micro inch nickel plated on contact area & and terminates 24-26 AWG standed wires , wiring scheme T568A/T568B (100 jack box)
Supply, Transportation and installation of Desktop with fully loaded software as desired, with the following configuration. (Model : HP or its equivalent in Dell/Lenovo) 1. Processor:Intel® Core™ i7 processor (10th or higher generation) with Intel® HD Graphics 630 (3.4 GHz base frequency with Intel® Turbo Boost Technology, 6 MB cache) Intel H110 Chipset 2. Memory: 32 GB DDR4-2666 or higher SDRAM (1 x 8 GB) 3. Hard drive 2x2 TB 7200 rpm SATA 4. DVD:RW 9.5MM Optical Disk Drive, 1 audio line in; 1 audio line out; 1 HDMI; 1 RJ-45; 1 VGA; 4 USB 3.0; 4 USB 2.0 5. Operating Systems: Preloaded Windows 10 professional 64 bit with preloaded License. However,the product key should be mentioned in the installation report at the time of installation. 6. Accessories: With required Keyboard ,Mouse, connecting cables and driver media should be supplied 7. Warranty: 3 Year Standard On-Site Comprehensive Hardware Warranty (including O.S support, Spares- Parts/Service/Labour/On-site)
Supply and installation of 55" ULTRA HD LED MONITOR of high Resolution with HDMI ports & USB port capability with 16*7 camera portals. With 3 year warranty.
Supply,installation,testing and commissioning of 15 mtr HDMI cable
Supply, Installation, Testing and Commissioning of 15W Wall Mounted Speaker complete with connection (AHUZA/OMEGA or equivalent)
Supply, Installation, Testing and Commissioning of 6W Ceiling Mounted Speaker complete with connection (AHUZA/OMEGA or equivalent)
Supply, Installation, Testing and Commissioning of 1.0 Sq mm speaker cable etc., complete with connections
Supply,installation,testing and commissioning of 25 mtr HDMI cable
SITC of 2x125W Class-D Amplifier with 4 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection Approved Makes : Bosch / Honeywell / Ateis
SITC of Network Resource Interface, 4 channels network audio source, 32 dry contacts in and 8 try contacts out for Fire Alarm Interface
Supply, Installation, Testing & Commissionig of 12 Volume Controller.
Providing, fixing, installing, testing and commissioning of exhaust pipe of following dia fabricated out of 8 mm thick MS plate and all fixing accessories and hardwares. The exhaust pipes shall be insulated with 75mm thick mineral wool insulation wrapped in chicken mesh and clad with 24 gauge aluminium sheet as required. Exhaust pipe shall also be inclusive of required supporting structure including heat resistant paint etc complete in all respect as required for successful operation of DG set in compliance with CPCB norms. Expansion bellows shall be provided at necessary location. 250 mm dia
Supply, installation, testing and commissioning of intelligent Addressable network control Repeater panel woth OFC network media communication module on FACP network configuration to monitor and control all local fire alarm control panels located in individual buildings built in buzzer,opticl fiber connectivity and RS 485 port on CPU board with optical network software connectivity fire/fualt indicators audio visual signals battery and charger CPU 80 character display unit complete in all respects with all required accessories etc cmplete
Supply & fixing of Addressable type multisensor detector with heat and smoke combination .This detectors shall have inbuilt short circuit isolator modules as per BS5839 standards and Duly Approved by EN54/IS2189 standard for installation and product shall be UL/FM/Vds
VESDA Panel Aspiration Smoke Detection System Securiras Asd - Securiton.
Supplying, installation, testing & commissioning of intelligent aspiration detector for area coverage of minimum 5000 sq. ft. complete as required
Supply, installation, testing and commissioning of the Analog addressable rate of rise cum fixed temperature detector with mounting based LED, address switch to programme the detectors complete as required.
Supply, installation, testing and commissioning of the Fault Isolators for isolating shorted, dewired and loose circuits between two successive fault isolators with 1.5 km range siren and automatic resetting arrangement complete as required.
Supply, installation, testing and commissioning of loop sounders along with all fixing accessories
Supply, installation, testing and commissioning of the Addressable control relay modules complete as required as per specifications.
Supply, installation, testing and commissioning of the Addressable Monitor modules complete as required as per specifications.
Supply, installation, testing and commissioning of the Manual Call Point complete as required as per specifications.
Supply, installation, testing and commissioning of the Fire Alarm Hooter and Strobe suitable for recessed/surface mounted including addressing module complete in all respect as required
Supplying, installation, testing & commissioning of intelligent addressable duct detector including suitable Photo detector complete with base as required.
Supply, installation, testing and commissioning of the Fire fighter's Telephone Jack suitable for recessed/surface mounted including addressing module complete in all respect as required
Supply, installation, testing and commissioning of the Fire Alarm multi tap Speaker suitable for Ceiling / wall mounted including addressing module having an audible range of 25 meters complete in all respect as required.
Supply and fixing of following sizes of steel conduit alongwith the accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same incase of recessed conduit as required. 20mm dia
Supply and fixing of following sizes of steel conduit alongwith the accessories in surface/recess including painting in case of surface conduit or cutting the wall and making good the same incase of recessed conduit as required. 25mm dia
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm
Supply,Instalation.Testing and commissioning of fire Alarm management software system and graphical display interaface to network the installed fire alarm panels using a network manager program and the following shall be pre-equipped with : Prepration of graphics compatile to fire alarm monitoring software of buildings and connected with clave panels including layout of the building and wiring digrm of the fire alarm system Inter connecting the same with fire alarm software located at master panel testing the paramaters and operations of individual detectors and slave panels Establishig two way communication with master panel and slave panels
Supply installation testing and commissioning of desktop computer i7 processor with 32" LED monitor WITH 16GB RAM loaded 1TB Hard disk and A3 size inkjet printer with all required software to work with fire alarm system
Supplying, installing, testing & commissioning of electric driven Main Fire Pump suitable for automatic operation consisting of the following: complete in all respect as required. Horizontal split casing multistage centrifugal suction type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical Seal to ensure a minimum pressure 3.5 kg/cm2 at highest and farthest outlet at specified flow of 2850 lpm against a total head of 70 metres (FOR HYDRANT & SPRINKLER)
Supplying, installing, testing & commissioning of Diesel Engine driven main fire Pump suitable for automatic operation consisting of the following (as per specification). Horizontal split casing multistage centrifugal suction type pump of cast iron body & bronze impeller with stainless steel shaft, mechanical Seal to ensure a minimum pressure 3.5 kg/cm2 at highest and farthest outlet at specified flow of 2850 lpm against a total head of 70metres with diesel engine exhaust pipe included
Providing & fixing, testing and commissioning of electrical driven pressurisation pump (jockey pump) suitable for automatic operation and comprising of following: complete in all respect as required. Horizontally mounted centrifugal end suction type Jockey pump complete of cast iron body & bronze impeller with stainless steel shaft, mechanical Seal delivery of 500 lpm against a total head of 70 metres
Providing & fixing, testing and commissioning of pressure boosting system pump at terrace (booster pump)testing and commissioning of electric driven Terrace / Booster pump suitable for automatic operation and consisting of following : complete in all respect as required. a) Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 900 lpm at 45 Mtr head conforming to IS 1520 b) Suitable HP SQ cage induction motor TEFC type suitable for operation on 415Volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325 Jockey Pump (Hydrant and Sprinkler Pump) each feed shall contain the following : d) Suitable cement concrete foundation duly plastered with anti vibration pads. 1837 a 900 LPM, 45 Mtr Head
Providing and placing of 20KLD HDPE (at all floor levels)polyetheylene water storage tank with double layer approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet and outlets and over flow pipes but without fittings and base support for tanks
Supply and laying of XLPE insulated PVC sheathed aluminium conductor 1.1 kv grade (armoured) U.G. power cable following size 3 .5 core 150 sq. mm.
Supply and laying of XLPE insulated PVC sheathed aluminium conductor 1.1 kv grade (armoured) U.G. power cable following size 3 core 25 sq. mm.
Supply and laying of XLPE insulated PVC sheathed aluminium conductor 1.1 kv grade (armoured) U.G. power cable following size 3 core 16 sq. mm.
supply and laying of multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured under ground cable of 1.1 KV grade 4 x 2.5 sq. mm
End termination with brass compression gland & al.lugs for following sizes of PVC insulated, PVC sheathed / XLPE Al. conductor cables of 1.1 KV grade as required. 3 .5 core 150 sq. mm.
End termination with brass compression gland & al.lugs for following sizes of PVC insulated, PVC sheathed / XLPE Al. conductor cables of 1.1 KV grade as required. 3 core 25 sq. mm.
End termination with brass compression gland & al.lugs for following sizes of PVC insulated, PVC sheathed / XLPE Al. conductor cables of 1.1 KV grade as required. 3 core 16 sq. mm.
Fabricating and installing following size of perforated M.S. cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including painting with powder coating etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness
Providing and fixing 25 mm x 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode as per specifications complete as required.
Providing and fixing 25 mm x 5 mm G.I. strip on surface or in recess from earth connections as per specifications complete as required.
Providing and fixing 6 SWG dia G.I. wire on surface in recess for loop earthing complete as required.
Providing, fixing, testing and commissioning of precharged air vessel (size 250 mm dia & 1500 mm height of 8.0 mm thick MS sheet) for pressurization of hydrant / sprinkler system complete with pressure gauges, one no 25 mm dia drain valve, air release valve on top and flanged connection to riser with stop cock on the top, 50 mm dia inlet with isolating valve duly painted with syntheic enamel paint of approved shade from inside and outside complete as required.
Supplying, testing, installation & commissioning of pressure switches for Hydrant, Sprinkler, Standby and Jockey Pumps, including necessary wiring upto control panel & other materials.
Providing & fixing dial type (150 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows, stainless steel 'U' tube & ball valve etc as required.
Providing & fixing dial type (100 mm) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows, stainless steel 'U' tube & ball valve etc as required.
Providing & fixing electronic type water level indicator with LED panel mounted as required by the Engineer-Incharge complete with probes & all control wiring etc.
Supply, erection, testing and commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets,orifice plates etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 25mm dia
Supply, erection, testing and commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets,orifice plates etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 32mm dia
Supply, erection, testing and commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets,orifice plates etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 40mm dia
Supply, erection, testing and commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets,orifice plates etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 50mm dia
Supply, erection, testing and commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets,orifice plates etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 65mm dia
Supply, erection, testing and commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets,orifice plates etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 80mm dia
Supply, erection, testing and commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets,orifice plates etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 100mm dia
Supply, erection, testing and commissioning of 'C' class MS heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets,orifice plates etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete 200mm dia (In shaft)
Supply, erection, testing and commissioning of 'C' class MS heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets,orifice plates etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete 150mm dia (In shaft)
Supply, erection, testing and commissioning of 'C' class MS heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets,orifice plates etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete 50mm dia (In shaft)
Supply, Laying ,testing and commisioning of centrifugally Cast ductile iron pipes conforming to IS:8329:2000 class k9, with cement mortar Lining inside as per IS 455:2989 along with bituminous coating outside suitable for socket and spigot type (DISS)with neoprone rubber push on joints for following sizes and testing the joints for leakage (if any) and making good hydrant system with all required accesories etc 200mm dia.
Supply,erection,testing and commissioning of Gun metal single headed fire hydrant landing valve with flanged inlet, brass spindle controlled 63 mm dia female instantaneous outlet type. CI wheel, GM coupling, blank cap, chain, twist release type lug & all accessories.
Supply,erection,testing and commissioning of gun metal grooved end type butterfly valves conforming to IS:14846, PN 1.6 with flanges for pipe including bolts,nuts and rubber insertions etc., complete and of following sizes: 100 mm dia
Supply,erection,testing and commissioning of gun metal grooved end type butterfly valves conforming to IS:14846, PN 1.6 with flanges for pipe including bolts,nuts and rubber insertions etc., complete and of following sizes: 150 mm dia
Supply,erection,testing and commissioning of gun metal grooved end type butterfly valves conforming to IS:14846, PN 1.6 with flanges for pipe including bolts,nuts and rubber insertions etc., complete and of following sizes: 200 mm dia (Gear Operated)
Supply,erection,testing and commissioning of gun metal Sluice Valves with S.S Disc: Wheel operated conforming to IS:14846, PN 1.6 with flanges for pipe including bolts,nuts and rubber insertions etc., complete and of following sizes: 100 mm dia
Supply,erection,testing and commissioning of gun metal Sluice Valves with S.S Disc: Wheel operated conforming to IS:14846, PN 1.6 with flanges for pipe including bolts,nuts and rubber insertions etc., complete and of following sizes: 150 mm dia
Supply,erection,testing and commissioning of gun metal Sluice Valves with S.S Disc: Wheel operated conforming to IS:14846, PN 1.6 with flanges for pipe including bolts,nuts and rubber insertions etc., complete and of following sizes: 200 mm dia
Supply,erection,testing and commissioning of :Ductile iron body grooved end type check valve (NRV) etc., complete and of following sizes: 100 mm dia
Supply,erection,testing and commissioning of :Ductile iron body grooved end type check valve (NRV) etc., complete and of following sizes: 200 mm dia
Ductile Iron grooved end type `Y' strainer with SS 304 perforated metal removable basket including all fittings complete as required and suitable for system pressure. 200 mm dia
Supply, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 oC temperature, working pressure 15 Kg/cm2 and test pressure 20 Kg/cm2 for : 50 NB
Supply, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 oC temperature, working pressure 15 Kg/cm2 and test pressure 20 Kg/cm2 for : 100 NB
Supply, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 oC temperature, working pressure 15 Kg/cm2 and test pressure 20 Kg/cm2 for : 150 NB
Supply, fixing, testing & commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 oC temperature, working pressure 15 Kg/cm2 and test pressure 20 Kg/cm2 for : 200 NB
Providing, fixing, testing & commissioning of Ductile iron grooved end type Zone Control Riser Module with FM Approval complete with necessary fittings – Shut Off & Test & Drain Valve, Waterflow Detector complete with all acessories as required. 80mm dia
Providing, fixing, testing & commissioning of Ductile iron grooved end type Zone Control Riser Module with FM Approval complete with necessary fittings – Shut Off & Test & Drain Valve, Waterflow Detector complete with all acessories as required. 100mm dia
Providing, fixing, testing & commissioning of Ductile iron grooved end type Zone Control Riser Module with FM Approval complete with necessary fittings – Shut Off & Test & Drain Valve, Waterflow Detector complete with all acessories as required. 150mm dia
Providing & fixing non-percolating rubber reinforced lined (RRL) fire hose pipe (as per IS : 636) Type-A of 63 mm dia and 15 meter length. The hose shall be rated for brust pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked brass male & female coupling (IS:903) bound & rivetted to hose pipe with copper rivets & 1.5 mm copper wire
Providing gun metal ISI marked 63 mm. dia. male Instantaneous pattern short branch pipes with 15 mm dia. Nozzle as per IS : 903, suitable for hydrostatic test pressure 21 kg/sqcm and suitable for interconnections to hose pipe coupling as required.
Supplying and fixing First- Aid Hose Reel full swinging type with MS construction spray painted conform to IS 884. with following as required. 30 m length x 20 mm (nominal internal) dia water hose Thermoplastic (Textile reinforced ) type-2 ase per IS: 12585 , 20 mm (nominal internal) dia gun metal globe valve & nozzel, Drum and brackets for fixing the equipments on wall,Connection from riser to hose reel 40 mm ball valve & M.S. pipe including sockets, nipples, elbows etc.
Providing and fixing standard fire hose cabinet single door with frame (1200 mm x 2100 mm ) or (suitable to fit in the duct made of not less than 16 SWG 2mm thick MS sheet having glass hinged door (6 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words "FIRE HOSE" to be painted on the box.
Supply & fixing 63 mm dia Cotton Synthetic Fibre (RRL) 2 nos Woven rubber lined fire hose treated against rot with MYSTOX, conforming to IS 636 type 'A' bounded with male and female instantaneous G.M. couplings and of length of 15 M.
Supply & installation of cast iron body 2 way 63 mm dia male instantaneous inlet coupling complete with inbuilt NRV, cap and chain for fire brigade connection conforming to IS : 904 and making connection with fire fighting pipe or under ground water tank, completing the work in all respect as per the directions of the Engineer-in-charge.
Providing & fixing MS cabinet (to enclose above FB connection) fabricated from 2 mm MS 304 sheet with full front glass door and locking arrangement duly painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and suitably mounted on a raised masonry platform as required (Approx 0.75m x 0.6m x 0.25m)
Providing & fixing gun-metal fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS: 902-1974 complete with 100 mm dia GI suction pipe and 100 mm dia foot valve (to be connected to static tank). Provision of GI drop pipe and foot valve shall be made in all the fire water static storage tanks (GI pipe to be paid separately through appropriate item while cost of foot valve to be included).
Providing, fixing, testing & commissioning of MS air cushion tank on top of each riser fabricated from 6mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS: 4736-1968.
Providing & fixing 25mm dia air release valve with forged brass body full way ball valve type isolating valve, flanges / union, suitable for sprinkler / wet riser / down comer system with all necessary connections complete in all respects.
Supply, fixing, testing & commissioning of FM approved Installation Control Valve with Grooved Ends with Black enamel coated ductile iron body conforming to ASTM A-536, grade 65-45-12, aluminum bronze clapper, stainless steel spring and shaft, EPDM seal, and Nitrile seat O-rings. Valve internal parts shall be replaceable without removing the valve from the installed position. Water working pressure is 300 psi. Suitable for constant and variable pressure systems with optional retard chamber & as per manufacturer's specifications complete as required. 150 mm diameter
Supply, fixing, testing & commisioning of C.P. bronze / gun metal quick response type Sprinklers, comprises of 15mm dia, glass bulb type, UL / FM listed / approved. The jointing shall be done by teflon tape and the installation shall be complete as per the drawings with positioning of sprinklers as per final coordinated plan and requirement of IS : 15105, local fire service & Engineer-in-charge. Pendent Sprinkler 68°C
Supply, fixing, testing & commissioning of Braided FM & VDS approved Annular Corrugation Stainless Steel flexible sprinkler pipe drop pressure rated upto 200 psi. The drop shall consist of a BRAIDED type 304 stainless steel flexible tube, zinc plated steel Male threaded nipple for connection to branch-line piping, and a zinc plated steel reducer with a female thread for connection to the sprinkler head and with a numbering on the reducer to ease the process for vertical positioning of the sprinklers with Bracket arrangement as per the Ceiling Profile. The bracket assembly shall be one piece open gate bracket complete in all respect. 1000mm
Supply, fixing, testing & commissioning of Braided FM & VDS approved Annular Corrugation Stainless Steel flexible sprinkler pipe drop pressure rated upto 200 psi. The drop shall consist of a BRAIDED type 304 stainless steel flexible tube, zinc plated steel Male threaded nipple for connection to branch-line piping, and a zinc plated steel reducer with a female thread for connection to the sprinkler head and with a numbering on the reducer to ease the process for vertical positioning of the sprinklers with Bracket arrangement as per the Ceiling Profile. The bracket assembly shall be one piece open gate bracket complete in all respect. 1200mm
Supply, fixing, testing & commissioning of Braided FM & VDS approved Annular Corrugation Stainless Steel flexible sprinkler pipe drop pressure rated upto 200 psi. The drop shall consist of a BRAIDED type 304 stainless steel flexible tube, zinc plated steel Male threaded nipple for connection to branch-line piping, and a zinc plated steel reducer with a female thread for connection to the sprinkler head and with a numbering on the reducer to ease the process for vertical positioning of the sprinklers with Bracket arrangement as per the Ceiling Profile. The bracket assembly shall be one piece open gate bracket complete in all respect. 1500mm
Providing, fixing, testing & commissioning of Ductile iron grooved end type Zone Control Riser Module with FM Approval complete with necessary fittings – Shut Off & Test & Drain Valve, Waterflow Detector complete with all acessories as required. 100mm dia
Providing, fixing, testing & commissioning of Ductile iron grooved end type Zone Control Riser Module with FM Approval complete with necessary fittings – Shut Off & Test & Drain Valve, Waterflow Detector complete with all acessories as required. 150mm dia
Supply & fixing pressure reducing station consisting of forged brass pressure reducing valve, butterfly valve at both end and bypass arrangement, with pressure guage at inlet and outlet (PN 16) with SS seal, metallic brass diaphram system suitable for controlling outlet pressure of water having inlet range of maximum 12 kg/cm2 and outlet range of 2-6 kg/cm2, complete with screwed ends as required. 150 NB
Supply, installation, testing and commissioning ISI marked (IS:2878) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 filled to a filling rate of not more than 0.667 and walll suspension braket.
Supply and fixing of ABC stored pressure squeeze grip type fire extinguishers, 9 kg capacity, IS:15683 : 2006, filled with ABC Mono Ammonium Phosphate base powder- 90 complete with discharge hose and wall mounting bracket, 2mm Mild Steel, EPDM Rubbers, Pressure Guage, which work effectively on all class of fires (A, B, C & Electrical fires) with 5 years warranty Including transportation, all taxes and all labour charges etc complete.
Supply of round bottom G.I sheet bucket of 9 Ltrs. Capacity as per IS:2546 made out of 24 gauge GI sheet with extra handle at bottom duly painted inside and red out side with printed with FIRE Mark for stand and hook and filled with sand and arranged to existing stand or hook.Floor mounting stand for keeping 4No of fire bucket 1500mm length, 900mm height made out of 40x40x6mm angle iron welded with 4 hooks and duly painted with one coat of red lead and two coats of enamel paint.
Gas Flooding system for IT panel Extinguishing Agent : 2 Kg Clean Agent NOVEC1230(UL/FM with Zero Ozone Depletion Potential , EPA & SNAP Approved Can : Stored Pressure Type, Deep drawn and Argon welded , M.S, Sheet metal thickness 1.5 mm, 100% Hydraulic Pressure tested, conform to EN/PED standarda. Can shall be manufactured as per IS:15683 and complete tests of the body as per IS 15683, shall be demonstrated.(Vibration, tapping,drop test, cylic pressure test, temperature range test) Burst pressure shall be greater than 55bars. CE Marked Tube for automatic fire detection and suppression system made by special modified Polyamide (PA), Color Red RAL300, High grade quality, Inner diameter 4mm, OuterDiameter 6 MM, Pressurised with dry Nitrogen at 13.5/10.5 bar pressure UL approved as per UL 521 STANDARD FOR HEAT DETECTORS FOR FIRE PROTECTIVE SIGNALING SYSTEMS T Connection, Brass, Nickle plated, for 4x6 mm Sensor Tube, quick and easydisassembly using special tool, External Diameter tube 6mm. End of Line Plug for Automatic fire suppression tube used for fitting at the tube end to terminate the point. Fitting made by brass nickel plated material . End of Line adapter with Pressure gauge for Automatic fire suppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube includes check Valve, Pressure Gauge and fitting to connect to sensor tubing. Tube connection 6mm. Pressure Switch to monitor Pressure drop in the tube, switch point 5 Bars. MASTER CONTROL UNIT
Supply and fixing of Escape signage boards in Rigid Photo luminecent based glow in Dark rigid sheet with highintensity luminous properties with specificaiton of Cease Fire or its equivalent make Model-1ES01
Supply and fixing of fire Equipement signages for all the fire equipments on each floor
Supply and fixing of Flexible Bellows for fire pump room with all required accessories complete of following 200mm dia
Supply and fixing of Flexible Bellows for fire pump room with all required accessories complete of following 100mm dia
Supply and fixing of emergency Exit Light fixtures with 2 hrs battery back up using SMF Battery.complete with required accessories. - Minimum Size 600 x 300 both sides transparent. It shall be ceiling / wall mounting suitable to site condition complete with required accessories.
Supply and installation of RCC hume pipes of 300 mm dia & NP 3 Class with collars for road / below floor crossing of Fire water pipes. The rate shall includes excavation, PCC ( 1:4:8 100 mm thick)bed and ends shall be closed with Brick masonry work as directed by Engineer - in- Charge
Supplying and wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistant tape as per IS : 10221 with 15 mm overlap as per specificatios.
Supplying of fire stop silicon sealant for fire pipes with 4hrs fire rating as per specificatios.
Supplying, transportation, installation, testing and commissioning of Multilevel puzzle car parking system of MAC model no : M7PM or equivalent make, consisting of 2 units of 7 level with 3 pit level back to back parking system for occupying 54 cars in one unit and 25 cars in the other unit, having lifting capacity of 2 tons (per car weight ) and operated with Hydraulic Cylinder with rope roller & chain, power pack and motorized sliding operation having lifting time 4m / minute, sliding time 3m / minute per platform. Platform shall be of size 4600mm length and 2100mm width. The system shall be operated with 415 V , 3 phase power supply, 50 Hz and the sliding motor shall be of reputed company Radicon/ Transolo or equivalent and hydraulic power pack shall be 5 HP motor, National Company (100 litres Oil tank). Each parking unit shall be provided Safety guide frame and double poppet valve directly in Cylinder. The price quoted shall be for complete sysytem except civil works such as foundations for stack parking which shall be measured under relevant item of the BOQ
Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m : All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and at all lifts/heights, as directed by Engineer-in-charge. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms,at all lifts/heights, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lifts
Supplying and filling murrum in plinth, sub base course to roads etc., including transporting, unloading, spreading, watering proper consolidating with 10 tonne power roller (wherever 10 tonne power roller cannot be operated the consolidation shall be done using 1 tonne vibro roller or heavy duty powered earth rammer) in layers not exceeding 150mm thick and dressing the surface complete as directed (Degree of consolidation 95% proctor density).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 Coarse sand : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for all heights: Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for all heights: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to all heights and levels Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position M 25 grade ready mixed concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable / recoverable separately) All works upto plinth level
Consolidation of sub-grade with road roller of 8 to 10 tonne capacity including making good the undulations, etc; with earth and re-rolling the subgrade complete all as per specifications.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-incharge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately) Note:- Cement content considered in M-30 is @ 350 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer
Providing and mixing in the concrete, fibres of approved make Comprising of Graded Fibrillated 100% Virgin Polypropylene fibers @ 0.9 Kg per cum of concrete and Macro Synthetic Fibers 38 /45 mm length - conforming to IS:17161-2020, EN14889-2 & ASTM C 1579-13 at 3 Kg per cum of concrete.
Supplying and laying 200 microns plastic sheets below RCC
Providing and fixing 25mm thick expansion joint filler board using Supreme Capcell-HD-100, Semi-rigid UV resistant high performance laminated closed cell polyethelene foam joint filler in sheet form complete as directed.
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder , railings, brackets, gates and similar works
20mm thick plastering in sumps / OHT / Drains and similar locations with cement mortar 1:3 (1 cement: 3 coarse sand) with water proofing compound mixed as per manufacturer instruction, a floating coat of neat cement including benching, haunching, providing over flow pipes and proper slopes, all as directed by Engineer-in-charge. (including cost of water proofing compound)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 Coarse sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Same as item No 603 above but for 300 mm dia. R.C.C. pipe
Same as item No 603 above but for 450 mm dia. R.C.C. pipe
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C.pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 Coarse sand) including testing of joints etc. complete 450 mm dia RCC pipes.
Same as item No 606 above but for 600 mm dia RCC pipes.
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 3.5
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in- charge.
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Providing and fixing in Bore well Slotted PVC pipes conforming to IS :12818, including all specials, jointing with seal ring conforming to IS code, leaving 10 mm gap for thermal expansion etc., complete 200 mm diametre
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and at all lifts/heights, as directed by Engineer-in-charge. All kinds of soil
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depths, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m for all lifts: All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 3.5
Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 3.5
Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid seperately): 80 mm dia nominal bore
Design, supply, erection, testing and commissioning of Inbuilt RO cum water cooler of capacity 80 LPH (60-80-50) of approved make including all accessories for fixing. Cooling capacity :60 lph, Tank Storage : 80 ltrs, RO Purification : 50 LPH , No. of Faucet: 2 no( Cold & Normal) . With HRR(Upto 70 % Recovery ) And Digital Display to Show healthiness level of membranes .. Inlet requirements : Inlet TDS : below 1500 PPM (Hardness below 500PPM), Inlet pressure: 0.5 to 2.0 kg. ESS - for Protecting the purified water from recontamination in water storage tank, preventing slime formation in the cooler water and shall ensure 24 X 7 protection.
Providing & fixing, testing and commissioning of pressure boosting system pump at terrace (booster pump)testing and commissioning of electric driven Terrace / Booster pump suitable for automatic operation and consisting of following : complete in all respect as required. Horizontal type, multistage, centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal and flow of 900 lpm at 45 Mtr head conforming to IS 1520 Suitable HP SQ cage induction motor TEFC type suitable for operation on 415Volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325 M.S. Fabricated common base plate, coupling, coupling guard, foundation bolts etc as required. Suitable cement concrete foundation duly plastered with anti vibration pads. Makes of Pumps : Kirloskar / Mather&Platt. Makes of Motors : Siemens / ABB / Kirloskar 1837 a 900 LPM, 45 Mtr Head
Supply, Testing & Commissioning, fixing of following bare GI tapes including all necessary fixing accessories, insulators and effecting connections as per specifications. 75 x 10 mm thick GI Colour Code tape
Supply, Testing & Commissioning, fixing of following bare Copper tape including all necessary fixing accessories, insulators and effecting connections as per specifications. 50 x 6 mm thick Copper Colour Code tape
Supply, Testing & Commissioning, fixing of following bare Copper / GI tapes / wires including all necessary fixing accessories, insulators and effecting connections as per specifications. 50 x 6 mm thick GI Colour Code tape
Supply, Testing & Commissioning, fixing of following bare Copper / GI tapes / wires including all necessary fixing accessories, insulators and effecting connections as per specifications. 25 x 6 mm thick GI Colour Code tape
Supply, Testing & Commissioning, fixing of following bare Copper / GI tapes / wires including all necessary fixing accessories, insulators and effecting connections as per specifications. 25 x 3 mm thick GI Colour Code tape
Supply, Testing & Commissioning, fixing of following bare Copper / GI tapes / wires including all necessary fixing accessories, insulators and effecting connections as per specifications. 8 SWG G.I Wire
Providing, laying, testing and commissioning of following 1100 volts grade PVC insulated sheathed copper conductor unarmoured cable including copper thimbles, fixing hardware as required. Single core 6 sq.mm Green colour cable
Supplying and making Cable end termination of following 1100 volts grade PVC insulated sheathed copper conductor unarmoured cable including copper thimbles, fixing hardware as required. Single core 6 sq.mm Green colour cable
Supply, installation, testing and commissioning of lockable terminal box in 1.6mm thick with MS enclosure with transperant cover with 1 no. (300 mm length) 50 x 6 mm copper strip on epoxy insulators with 30 no. 8mm dia holes with 8mm x 25mm dia brass nut bolt with double washer.
Design, Fabricate , Supply, Testing and commissioning of HT metering Breaker 630A 11kV Outdoor Type Metering cubical VCB with required CT/PT and Trivector Meter all assembled in same breaker. The CT/PT shall be for the load of 630KVA ,11KV and shall be tested as per department requirement in consultation and engineer incharge of the project. The Trivector Meter Shall have the all communication port and all the features of partial automation with required accesories. This Metering Breaker is installed at the inside the building perimeter complete job including earthing and commissioning.
11/0.415 KV DRY TYPE TRANSFORMERS Supply, Transportation, Installation, Testing and Commissioning of 3 Phase, 50 Hz, 1250 KVA Dry type, Indoor type copper wound Transformer designed and manufactured as per IS 2026-1977 and IS 11171-1985, connected delta on primary side and Star on secondary side with additional neutral brought out on load side, 11000V / (433V / 415V) with HV off load tap changing + 5% to -5% in steps of 2.5%, temperature rise by the resistance 90⁰C complete with test reports with the following standard mountings. 1. Rated KVA : 1250 KVA (Cast Resin), 2. Service: Indoor, 3. Mounting : Floor, 4. Copper wound : Double. 5. Type of cooling : ANAN. 6. Insulation Class : Class F 7. Temperature rise by resistance : 90⁰C 8. Vector Group: Dyn 11 9. Primary Connection : Delta 10. Primary Volts : 11000 11. Primary Frequency : 50 12.Primary Phases : 3 13. Primary wires: 3 14. Secondary connection : Star 15. Secondary Volts : 433V / 415V 16. Secondary phases : 3 17. Secondary wires: 4 18. Taps on primary winding for primary voltage variation : +5.0% to - 10.0% in steps of 2.5% through links. 19. Terminal arrangement. a. HV: Cable end box b. LV : Cable end box 20. No load losses (Watts): As per IS specifications 21. Load losses (Watts): As per IS specifications 22. Impedance(Z%) : As per IS specifications 23. Fittings & Accessories. a. Rating and terminal marking plate b. Earthing terminals c. Lifting Lugs d. Winding temperature Indicator e. Separate neutral bushing f. Uni directional flat rollers.
Supply,Installation,Testing & Commissioning of 125 kVA UPS microprocessor controlled True Online double conversion, Stand Alone mode 3 Phase input and 3 phase 415V output with rectifier+inverter with integrated,Battery Circuit breaker, Inbuilt Static switch for bypass and inverter,Manual Maintenace bypass with SMF sealed maintenance free batteries for 30 minutes backup time with UPS & interconnectors, Rack,wire leads,interlinks and accessories and UPS to battery DC cable upto 30 meters with 3 years warranty etc complete for Work Stations, Fire Alarm, CCTV and Server. (Make : Vertive/APC / Numeric / Emerson.)
Supply and fixing in position 1000 mm wide, 2000 mm length Insulating rubber matts of 1.1 kV grade as per electricity rules (exact length rubber mats to be worked out as per site requirement)
Supply and fixing in position the approved “Shock Treatment Charts” written in English and Local Language. These charts shall be framed in teak wood frame and covered with glass.
Supply and installation of fire sand bucket of 9 Ltr. Cap. With bucket stand fabricated out of M.S. Sheet of 24 SWG including all accessories as required.
Supply and fixing in position the best quality Danger Boards of approved shape and size as specified by Local Electricity Authorities written in English & Local Languages.
Supply and fixing position the approved single line diagram framed on A3 size paper with glass frame and installed in main LT Panel Room.
Supply of first aid box with all accessories required for 11 kV equipment with 1 pair 11 kV rubber hand gloves of approved make.
Design, fabrication, assembling, wiring and supply, installation, testing and commissioning of LT Panel, Distribution Panels, fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in cubicle compartmentised modular 3b construction, free standing floor mounted with bottom cable entry, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels. Sub Floor Panels: Incomer-1 comprising of : 125A amps 4P Motorised MCCB breaker with over current, short circuit protection releases etc. - 1 Set, Multifunction meter for V, Hz & A with CT's - 1 Set, ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set, Incomer-2 comprising of : 125A amps 4P Motorised MCCB breaker with over current, short circuit protection releases etc. - 1 Set, Multifunction meter for V, Hz & A with CT's - 1 Set, ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Coupler: 125A amps 4P Motorised MCCB breaker with over current, short circuit protection releases etc. - 1 Set, Multifunction meter for V, Hz & A with CT's - 1 Set, ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : 125 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeve - 1 set, Outgoing comprising of : 63 amps TPN MCB - 8 Set, 40 amps TPN MCB - 6 Set Notes: All breakers shall be minimum 10 kA rating with Icu = Ics.
Design, fabrication, assembling, wiring and supply, installation, testing and commissioning of LT Panel, Distribution Panels, fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in cubicle compartmentised modular 3b construction, free standing floor mounted with bottom cable entry, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels. HVAC VRF ODU PANEL: Incomer-1 comprising of : 1250 amps 4 Pole Electrically operated fully draw out type air circuit breaker Ics 50 kA with microprocessor release unit. - 1 Set, Multifunction meter for V, Hz & A with CT's - 1 Set, ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set. Incomer-2 comprising of : 1250 amps 4 Pole Electrically operated fully draw out type air circuit breaker Ics 50 kA with microprocessor release unit. - 1 Set, Multifunction meter for V, Hz & A with CT's - 1 Set, ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Coupler: 1250 amps 4 Pole Electrically operated fully draw out type air circuit breaker Ics 50 kA with microprocessor release unit. - 1 Set Bus Bar comprising of : 1250 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeve - 1 set Outgoing comprising of : 100 amps TPN MCCB with Thermal Magnetic release unit along with VFD+Dol Starter,Contactor,Led Lamps,,push button etc - 40 Set Notes: All breakers shall be minimum 10 kA rating with Icu = Ics.
Design, fabrication, assembling, wiring and supply, installation, testing and commissioning of LT Panel, Distribution Panels, fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in cubicle compartmentised modular 3b construction, free standing floor mounted with bottom cable entry, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels. PHE PUMP PANEL. Incomer comprising of : 63 amps TPN MCCB with Thermal Magnetic release unit along with,push button etc - 1 Set, Multifunction meter for V, Hz & A with CT's - 1 Set, ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : 63 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeve - 1 set Outgoing comprising of : 32 amps 2 Pole MCB - 06 Set, 16 amps 2 Pole MCB - 02 Set Notes: All breakers shall be minimum 10 kA rating with Icu = Ics.
Design, fabrication, assembling, wiring and supply, installation, testing and commissioning of LT Panel, Distribution Panels, fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in cubicle compartmentised modular 3b construction, free standing floor mounted with bottom cable entry, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels. EXTERNAL LIGHTING PANEL. Incomer comprising of : 63 amps TPN MCCB with Thermal Magnetic release unit along with,push button etc - 1 Set, Multifunction meter for V, Hz & A with CT's - 1 Set, ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : 63 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeve - 1 set Outgoing comprising of : 32 amps 2 Pole MCB WITH 24 TSQ TIMER & Contactor- 05 Set Notes: All breakers shall be minimum 10 kA rating with Icu = Ics.
Design, fabrication, assembling, wiring and supply, installation, testing and commissioning of LT Panel, Distribution Panels, fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in cubicle compartmentised modular 3b construction, free standing floor mounted with bottom cable entry, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels. UPS PANEL Incomer comprising of : 250 amps TPN MCCB with Thermal Magnetic release unit along with,push button etc - 1 Set, Multifunction meter for V, Hz & A with CT's - 1 Set, ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : 250 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeve - 1 set Outgoing comprising of : 125 amps 4 Pole MCCB - 02 Set, 63 amps 4 Pole MCB - 13 Set.Notes: All breakers shall be minimum 10 kA rating with Icu = Ics.
Design, fabrication, assembling, wiring and supply, installation, testing and commissioning of LT Panel, Distribution Panels, fabricated out of (load bearing member of 2mm and non load bearing member 1.6 mm thick) CRCA sheet steel in cubicle compartmentised modular 3b construction, free standing floor mounted with bottom cable entry, dust and vermin proof with reinforcement of suitable size angle iron, channel, `T’ sections and / or flats wherever necessary. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. 2 Nos. earthing terminals shall be provided for all distrtibution panels. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. Lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel in the form of shop drawings before fabrication. Galvanised hardwares with zinc passivation shall be used in fabrication of panels. COMMON SERVICE PANEL Incomer comprising of : 160 amps TPN MCCB with Thermal Magnetic release unit along with,push button etc - 1 Set, Multifunction meter for V, Hz & A with CT's - 1 Set, ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set. Bus Bar comprising of : 160 Amps TPN Aluminium Bus Bar with colour coded heat shrinkable sleeve - 1 set Outgoing comprising of : 63 amps 4 Pole MCCB - 03 Set, 63 amps 4 Pole MCB - 13 Set.Notes: All breakers shall be minimum 10 kA rating with Icu = Ics.
RISING MAIN/ BUS DUCT Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following capacity Sandwich Type Busduct for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with metal clad enclosure having IP-54 rating and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 0.8 A / sq. mm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every meter and copper flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 2000 A, Isc = 50 kA for 1 second Indoor Type (Sandwich Type)
RISING MAIN/ BUS DUCT Supplying, installing by suspension on ceiling/along the wall, testing and commissioning of following capacity Sandwich Type Busduct for use on 3 phase 4 wire 415 V, 50Hz A.C. supply with metal clad enclosure having IP-54 rating and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos. aluminium bus bars having current density of 0.8 A / sq. mm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every meter and copper flexible for joints, continuous earthing with 2 Nos. aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as required 1250 A, Isc = 50 kA for 1 second Indoor Type (Sandwich Type)
Supply and Fixing of following Tap off box for Sandwich Type Busduct.630A 4P Tap off Box with MCCB. ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set.
Supply and Fixing of following Tap off box for Sandwich Type Busduct.160A 4P Tap off Box with MCCB. ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set.
Supply and Fixing of following Tap off box for Sandwich Type Busduct.125A 4P Tap off Box with MCCB and ON / OFF / TRIP indicating lights with control MCB - 1 Set, Phase indicating light protected by 2 amps MCB’s - 1 Set.
HT CABLE: Supplying,Installation.Testing and Commissioning of 3 core 240 sq.mm Al Conductor armoured cable 11kV grade XLPE(E) insulated Aluminium conductor armoured cables as per specification complete in all respect as required.
HT CABLE TERMINATIONS: Supplying and making OF 240 sq. mm indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required
Supplying,installation,testing and commissioning of 9 meter Height hot dip galvanised continously tapered (bolt fixing type) octagonal Single Arm Pole with top 70 mm dia and bottom 130 mm dia made of 3 mm thick H T sheet Steel conforming to grade S 355 complete with G I base plate of size 200 mm (L) X 200 mm (B) X 12 mm thickness welded at the bottom of pole complete with 4 Nos 16 mm dia 450 mm long foundation bolts confroming to EN 8 grade, inbuilt / Vandal resistance, weathproof electrical junction box having terminal block, MCB etc mounted on bakelite sheet for looping in /looping out of cables, with flush door having locking arrangement, earthing arrangement (at atleast 0.5 m height) and mounted on RCC foundation of size 500 mm x 500 mm x 1600 mm in ground and 200 mm above ground level with foundation bolt duly embeded before casting and supply and embedding of suitable size HDPE pipe sleeve for cable entry. complete including erection of Pole complete in all respect as per specification as required. (Makes: BAJAJ / VALMONT / TRANSRAIL/ LAASMA.)
Supply Installation , Testing & Commissioning of IP 65 70W LED Street Light with 7200lm Die cast aluminium housing with secondary lens optics with THD<10% and PF>0.95 with IP66 protection (Philips BRP409 LED CW 036 MR FG S1 PSU GR, Panasonic PSTM16708)
Supply Installation , Testing & Commissioning of IP65 60W LED Flood light with system lumen output100lm with dies cast aluminium housing in 5700K CCT and Heat resistant frosted glass with frame grillcover.(Philips BVP120 LED 70 CW FG S1 PSU GR, Panasonic PBYM05507)
Supply Installation , Testing & Commissioning of 25W gate Light with Die cast aluminium housing with secondary lens optics with THD<10% and PF>0.95 with IP66 protection. (Havells CORALPT25WLED757PSYMTOPC)
Supply Installation , Testing & Commissioning of 10W Bollard Light with Die cast aluminium housing with secondary lens optics with THD<10% and PF>0.95 with IP66 protection. (Philips BCP151 LED150/NW PSU 220-240V 7043, or its equivalent)
Supply Installation , Testing & Commissioning of 25W Post Top Lantern Light with 3.5 mtr Decoative Pole Die cast aluminium housing with secondary lens optics with THD<10% and PF>0.95 with IP66 protection.(PhilipsBGP161 LED2500/NW PSU 220-240V 7043 IN, or its equivalent)
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and at all lifts/heights, as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lifts
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for all heights: Foundations, footings, bases of columns, etc. for mass concrete
Same as item No 671 above but for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Same as item No 671 above but for Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all heights and levels Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position M25 grade ready mixed concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable / recoverable separately) All works upto plinth level
Same as item No 675 above but for All works above plinth level upto floor V level
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
20mm thick plastering in sumps / OHT / Drains and similar locations with cement mortar 1:3 (1cement: 3 coarse sand) with water proofing compound mixed as per manufacturer instruction, a floating coat of neat cement including benching, haunching, providing over flow pipes and proper slopes, all as directed by Engineer-in-charge. (including cost of water proofing compound)
White washing with lime to give an even shade : New work (three or more coats)
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 150 mm diametre S.W. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885
Providing M.S. foot rests including fixing in manholes with 20x20x 10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
Design, Supply, erection and Commissioning of packaged sewage treatment plant of capacity 35m3 per day of Ion Exchange / Thermax or approved equivalent brand , suitable for installing in basements where clear height available under the beam shall be 3.5m.The STP shall consist of bar screen chamber, oil and grease trap chamber equilisation tank,biocask, FAB Feed pumps including Motors, Air blowers including motors, FAB reactors, Tube settlers, Sludge holding tank, Chlorine dosing system, V Notch plate, Filter feed pumps, Activated Carbon filter, centrifuge system, gear box, motor, MCC panel, any other equipment as required for tertiary system of treatment including supply, erection and testing of inter connecting pipe works, cabling, earthing with cable tray etc., all complete for finished item of work to the satisfaction of Engineer-in-Charge (Civil works will be measured separately) NOTE: 1. The free trial runoff period for the STP shall be one month or till stabilization of STP units to provide desired treatment efficiencies which ever is later. , 2. The treatment shall be to the standards of tertiary treatment satisfying the following outlet parameters, BOD < 5 mg /l , COD < 30 mg/l, total suspended solids < 5 mg/l, PH value 6.5 - 8.0, oil and grease < 10 mg/l, temperature 25 - 30 degree centigrade. Only the following civil works shall be paid separately - 1) Bar screen pit 2) Oil & grease trap chamber 3) Equilisation tank 4) Chlorine contact tank 5) Filter feed tank 6) Treated water tank 7) Int. Sludge sump 8) Sludge holding tank 9) Drain Sump 10) Platforms for dosing tank and foundations for equipment. The items listed below shall be under the scope of supply i) Bar Screen (2 Nos) - Suitable for 35 KLD FAB, ii) Air grid for equalisation tank (1 Lot) - Suitable for 35 KLD FAB, iii) FAB feed pumps (2 Nos- 1 W+ 1 S) - Suitable for 35 KLD FAB, iv) Motors for FAB feed pumps (2 Nos- 1 W+ 1 S)- Suitable for 35 KLD FAB, v) Air Blowers (2 Nos- 1 W+ 1 S) - Suitable for 35 KLD FAB, vi) Motors for Air Blowers (2 Nos- 1 W+ 1 S) - Suitable for 35 KLD FAB, vii) Biocask media - 1 Lot - Suitable for 35 KLD FAB, viii) Biocask - Air distribution grid - 1 Lot - Suitable for 35 KLD FAB, ix) Biocask reactor - 1 No.- Suitable for 35 KLD FAB, x) Tube settler media (1 Lot) - Suitable for 35 KLD FAB, xi) Collection Trough (1 Lot) - Suitable for 35 KLD FAB, xii) Air grid for sludge holding tank (1 Lot) - Suitable for 35 KLD FAB, xiii) Hypo dosing system (1 No) - Suitable for 35 KLD FAB xiv) PAC dosing System (1 No) - Suitable for 35 KLD FAB, xv) PE dosing System (1 No) - Suitable for 35 KLD FAB, xvi) Filter feed pumps (2 Nos (1W+1S)) - Suitable for 35 KLD FAB, xvii) Dual media filter (1 No) - Suitable for 35 KLD FAB, xviii) Activated carbon filter (1 no) - Suitable for 35 KLD FAB, xix) Inter connecting piping and valves for air line (1 Lot) - Suitable for 35 KLD FAB, xx) Inter connecting piping and valves for sewage line (1 Lot) - Suitable for 35 KLD FAB, xxi) Instruments (1 Lot) - Suitable for 35 KLD FAB, xxii) Distribution board (1 no) - Suitable for 35 KLD FAB, xxiii) Electricals (1 Lot) - Suitable for 35 KLD FAB, xxiv) Centrifuge system (1 Lot) - Suitable for 60 KLD FAB, xxv) Pressure gauges (1 Lot), xxvi) Air Rotameter (1 No), xxvii) Level switches (1 Lot)
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, at all lifts/heights, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lifts
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Same as item No 689 above but for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Same as item No 689 above but for Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all heights and levels Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position M25 grade ready mixed concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable / recoverable separately) All works upto plinth level
Same as item No 693 above but for all works above plinth level upto floor V level
Providing and fixing above plinth level up to floor V level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete all as per specification / Drawings or as approved by Engineer-in-Charge 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder , railings, brackets, gates and similar works
Providing and fixing 18 to 20mm thick Polished Granite cladding with edge chamfering whereever required of approved shade stones of required size, backing filled with a grout of 12mm thick in cement mortar 1:3 (1 cement :3 Coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade complete for all heights and lifts as per drawing and directions of Engineer-in-charge. (To be secured to the backing by means of stainless steel cramps which shall be measured as a separate item)
Providing and fixing 18 to 20mm thick Rough Granite cladding with edge chamfering whereever required of approved shade stones of required size, backing filled with a grout of 12mm thick in cement mortar 1:3 (1 cement :3 Coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade complete for all heights and lifts as per drawing and directions of Engineer-in-charge. (To be secured to the backing by means of stainless steel cramps which shall be measured as a separate item)
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Supply, Installation, Testing and Commissioning of Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required :- Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2 and BIS approved. Solar Photovoltaic Module conversion efficiency shall not be less than 18%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years. Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. Inverter,ACDB and Data Monitoring System,complete with accessories. Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and cable tray other accessories,supports etc. as required. Lightning and surge voltage protection. Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.
TREES: Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 90 cm dia, and 90 cm deep
Supply and stacking of tree plants of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. Peepal
Supply and stacking of tree plants of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. Rain Tress
Supply and stacking of tree plants of ht 150-165 cm in bag size of 25 cm as per direction of the officer-in-charge. Sisso
ORNAMENTAL FLOWERING TREES Temple Tree
ORNAMENTAL FLOWERING TREES Neeli Gulmohar
ORNAMENTAL FLOWERING TREES Queens Crape
Plantation of Tree plants at site i/c watering and removal of unserviceable material’s as per direction of officer in charge (excluding cost of plant & water).
Maintenance of trees (out side of lawn area) of tree saplings, after plantation for 30 days for well establishment of tree saplings, jobs like making of basin at regular interval i/c watering, weeding, prunning & application of fertilizer etc, (excluding the cost of material ) and as per direction of officer in charge.
Anti termite treatment by digging holes 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 litter per hole in two time or more application to get the trees free from termite infection chemicals used chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge.
Regular maintenance of trees(out side of lawn area), jobs like making of basin at regular interval i/c watering,weeding,prunning & application of fertilizer etc, (excluding the cost of material ) and as per direction of officer in charge for 1 year.
SHRUBS Preparation of beds for shrubs by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
Supply and stacking of shrub plants of height 60-75 cm as per direction of the officer-in-charge Crepe Jasmine
Supply and stacking of shrub plants of height 60-75 cm as per direction of the officer-in-charge Night Flowering Jasmine
Supply and stacking of shrub plants of height 60-75 cm as per direction of the officer-in-charge Indian Boxwood
Plantation of shrub plants at site i/e watering and removal of unserviceable material’s as per direction of officer in charge (excluding cost of plant & water ).
Initial maintenance of shrubs (Out side of lawn area) for jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge for 1 month
Regular Maintenance of shrubs (Out side of lawn area) , for 1 year jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc, (excluding the cost of material ) and as per direction of officer in charge for 1 year
HEDGES Preparation of beds for hedging by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, levelling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately).
Supply and stacking of hedge plant saplings density @ 5 No of plants for 01 Rmt as per direction of the officer-in-charge
Plantation of hedge plants density @ 5 Nos of plants for 1 Rmt at site i/e watering and removal of unserviceable material’s as per direction of officer in charge (excluding cost of plant & water ).
Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/edge bed watering, manureing and applying insecticides and fungicides etc.(excluding the cost of materials ) and as per direction of officer in charge for 1 month
Regular maintenance of hedges by regular watering, Cutting of Hedge/ Edge including removing of cut material, cleaning, hoeing of hedge/ edge bed watering, manureing and applying insecticides and fungicides etc.(excluding the cost of material ) and as per direction of officer in charge for 1 year
LAWN Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts.
Anti termite treatment of lawn area through premise 30.50% I P. one litter premise diluted in 499 litters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical and as per direction of officer-in-charge. And as per direction of officer-in-charge.
Regular maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn including hoeing, weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and manure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide , Pesticide , to be paid seperately & other T & P material/articles shall be provided by the contractor.)and as per direction of officer in charge for 1 year.
POTTED PLANTS: Supply PVC pots of size top inside dia 30 cm, outer bottom dia 20 cm, total height 30 cm including bottom plate
Filling the empty pots of size 30 cm top dia, 15 cm bottom dia & 25 cm height with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on appropriate place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer in charge. (The cost of good earth, pots & manure will be paid separately.)
Supply and plantation of plant of height 30 to 45cm ht well developed, fresh & healthy with good fooliage as per direction of the officer-in-charge,
Maintenance of potted plant PVC pot in displayed at ground floor only in bungalow, office complex including application of good earth, manure, insecticide, pesticide and fertilizer, removing of dry parts by pruning, cleaning dry leaves and displaying in appropriate place and replacement of broken pots colouring of pots and change of location of pots and replacing with fresh plants as and when required ( Materials shall be provided by the department) as per direction of officer in charge
Supplying and stacking of good earth at site including royalty and carriage upto 5 k.m. lead complete (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site Manure including royalty and carriage upto 5 Km complete (manure measured in stacks will be reduced by 8% for payment)
Pipe Line:- Supply, fixing, testing and commissioning of 63mm dia rigided PVC pipes 4kgf/CM2 with ISI mark with all required accessories, outlet points etc., including earth work execution in all kind of soil, back filling and ramming as required and disposal of surplus earth within the site, as directed by the site In charge.
Making provision for facade cleaning by parapet mounted Jib system where cradle shall be suspended with a pair of parapet mounted jibs which shall be fixed to the parapet wall with the help of jib brackets placed at 2.5m c/c. Each jib bracket shall be fixed with the help of 6 Nos. M16 SS mechanical anchors. The vertical movement of the cradle shall be electrical and the horizontal movement shall be manual by shifting the jib left to right or right to left vice versa (Parapet mounted Jib and double suspension standard cradle shall not be in the present scope) Providing and fixing parapet mounted jib brackets
Making provision for facade cleaning by parapet mounted Jib system where cradle shall be suspended with a pair of parapet mounted jibs which shall be fixed to the parapet wall with the help of jib brackets placed at 2.5m c/c. Each jib bracket shall be fixed with the help of 6 Nos. M16 SS mechanical anchors. The vertical movement of the cradle shall be electrical and the horizontal movement shall be manual by shifting the jib left to right or right to left vice versa (Parapet mounted Jib and double suspension standard cradle shall not be in the present scope) Providing and fixing M16 mechanical anchors of Hilti or equivalent make for bracket fixing
Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete secant piles of grade M-30 of 600mm diameter and length, to carry safe working load not less than specified, excluding the cost of steel reinforcement and concrete but including the cost of boring with bentonite solution,cost of shoe and the length of pile to be embedded in the hard rock strata etc. all complete. which involves below mentioned activities. a) Driving a metal casing, permanent or temporary with a shoe at the tip and displacing the material laterally. b) Providing steel reinforcement cage with cover blocks etc. which shall be paid under the respective steel item c) Providing M 30 grade concrete using tremie method which shall be paid under the respective concrete item d) Excavating around the pile for a depth of 1m post concrete and breaking 1m of the top of the pile, removing the debris to a location as directed by Engineer in Charge. Note : 1) Chipped off concrete shall not be measured for payment. 2)The Contractor shall submit to the Engineer a pile installation programme. The proposed sequence and timing of pile installation shall be such that the installation works shall not cause any damage to adjacent piles. Piling works shall not commence until approval of the Engineer has been obtained. 3) Piles shall not be bored into other piles which have recently been cast and which contain workable or partially set concrete that a flow of concrete or instability could be induced or damage caused to any installed piles. 4) The Contractor shall also carry out necessary grouting or sealing using suitable materials to control and prevent collapse of the boreholes or lost of drilling fluid or lost of concrete during installation of secant piles
Providing and Laying in position Ready mixed cement concrete of M-30 grade for piles using tremie method including pumping of concrete to site of laying, curing, carriage for all leads etc complete . Top of piles shall be chipped off to desired level as directed by Engineer in-charge. Chipped of concrete shall not be measured & paid and chipped concrete shall be disposed off as directed by the Engineer In Charge.
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Note: 3. Contractor shall submit minimum three copies of load test reports to the Engineer-in-Charge. (i) Single pile upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity)
Lateral load testing of single pile in accordance with IS Code of practice IS : 2911 (Part IV) for determining safe allowable lateral load on pile : Upto 50 tonne capacity pile
Som Projects Pvt. Ltd.
KALPANA STRUCT CON PRIVATE LIMITED
Dev Engineers
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.26 MB
rfpfinal.pdf
Tender Documents • 1.45 MB
BOQ_136222.xls
BOQ • 0.93 MB
appendixseventwobookone.pdf
Additional Documents • 37.73 MB
appendixsevenvolone.pdf
Additional Documents • 3.44 MB
appendixseventwobooktwo.pdf
Additional Documents • 35.26 MB
Download all tender documents and submit your bid