Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC PLOT NO F AND G RAKBA DARAKHERA PROFESSOR COLONY NAGAR PARISAD THANESAR KURUKSHETRA HARYANA 136 118 | ₹1.4 Cr | L1 | Accepted-AOC LOA issued |
| 2 | L2₹1.6 Cr+₹25.0 L (17.9%)Rejected-Finance B 1703 MODERN INDUSTRIAL ESTATE BAHADURGARH HARYANA 124507 | BAHADURGARH | JHAJJAR | HARYANA | 124507 | ₹1.6 Cr+₹25.0 L (17.9%) | L2 | Rejected-Finance L2 |
Tender Value
₹1.6 Cr
EMD Value
₹3.2 L
Closing Date
15 Apr 2025, 5:00 pmClosed
VISHWNATH KHICHI
ED - Karnal
Construction of the building of MCH block at Civil Hospital Distt. Panipat (Pdg. Balance HVAC only).
2025_HRY_437492_1
202524F6B95F 2230 4398 942F 73379B9AD3DF665BAR
Open Tender
Electrical Works
Works
90 days
Panipat
2 documents required · 2 mandatory
₹15,000
₹3.2 L
Yes
16 May 2025
31 Mar 2025
16 Apr 2025
1 Apr 2025
15 Apr 2025
1 Apr 2025
Amount
[24.14.10]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 10. 6 Sq mm 3 core (Arm.) [Through Rate]
[24.14.16]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 16. 10 Sq mm 3 core (Arm.) [Through Rate]
[24.14.70]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 70. 120 Sq mm 3.5 core (Arm.) [Through Rate]
FLOOR MOUNTED AIR HANDLING UNITS WITHOUT HEATING COIL Supply, Installation, Testing and Commissioning of factory fabricated Indoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with 0.8 mm thick precoated galvanised sheet outside and 0.8 mm thick 275 GSM Galvanised Steel sheet inside with Backward curved direct driven plug type Metallic construction in supply with fan section with fan motor with IE3 rating and suitable for 415 plus 10%, 3 Phase, 50 Hz along with IP 20 VFD, 6 RD cooling coil with coil section, prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% before cooling coil, fine filter ( EU-7 / F7 ) / MERV-13 section with Synthetic fibre media with frame material made out by Aluminium anodized with flange rigid media with efficiency 99 % at 3µ (micron) in supply . The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor and belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU panel shall be insulated with 48 plus /-2 mm thick injected fire retardent PUF of density 40 plus /-2 Kg/m³ . The motor and fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling / heating coil, filters should not exceed 500 FPM. The capacities of airhandling shall be as follows NOTE: 1. Magnehelic differential pressure gauge required with fine filter and same shall be included in AHU. 2. AHU, Fans and Coil should be AHRI / EUROVENT Certified 3. Noise Level should not be exceed dB70 @ 1 Meter 4. GA drawing and technical Data sheets should be get approval before dispatch 9500 CFM / 65 mmwg St. Pressure
CEILING SUSPENDED AIR HANDLING UNITS WITHOUT HEATING COIL Supply, Installation, Testing and Commissioning of factory fabricated Indoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with 0.8 mm thick precoated galvanised sheet outside and 0.8 mm thick 275 GSM Galvanised Steel sheet inside with Backward curved direct driven plug type Metallic construction in supply with fan section with fan motor with IE2 rating and suitable for 415 plus 10%, 3 Phase, 50 Hz along with IP 20 VFD, 4 RD cooling coil with coil section, prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% before cooling coil, fine filter ( EU-7 / F7 ) / MERV-13 section with Synthetic fibre media with frame material made out by Aluminium anodized with flange rigid media with efficiency 99 % at 3µ (micron) in supply . The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor and belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU panel shall be insulated with 25 plus /-2 mm thick injected fire retardent PUF of density 40 plus /-2 Kg/m³ . The motor and fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling / heating coil, filters should not exceed 500 FPM. The capacities of airhandling shall be as follows NOTE: 1. Magnehelic differential pressure gauge required with fine filter and same shall be included in AHU. 2. AHU, Fans and Coil should be AHRI / EUROVENT Certified 3. Noise Level should not be exceed dB 55 @ 1 Meter 4. GA drawing and technical Data sheets should be get approval before dispatch 1200 CFM / 60 mmwg St. Pressure
CEILING SUSPENDED AIR HANDLING UNITS WITHOUT HEATING COIL Supply, Installation, Testing and Commissioning of factory fabricated Indoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with 0.8 mm thick precoated galvanised sheet outside and 0.8 mm thick 275 GSM Galvanised Steel sheet inside with Backward curved direct driven plug type Metallic construction in supply with fan section with fan motor with IE2 rating and suitable for 415 plus 10%, 3 Phase, 50 Hz along with IP 20 VFD, 4 RD cooling coil with coil section, prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% before cooling coil, fine filter ( EU-7 / F7 ) / MERV-13 section with Synthetic fibre media with frame material made out by Aluminium anodized with flange rigid media with efficiency 99 % at 3µ (micron) in supply . The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor and belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU panel shall be insulated with 25 plus /-2 mm thick injected fire retardent PUF of density 40 plus /-2 Kg/m³ . The motor and fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling / heating coil, filters should not exceed 500 FPM. The capacities of airhandling shall be as follows NOTE: 1. Magnehelic differential pressure gauge required with fine filter and same shall be included in AHU. 2. AHU, Fans and Coil should be AHRI / EUROVENT Certified 3. Noise Level should not be exceed dB 55 @ 1 Meter 4. GA drawing and technical Data sheets should be get approval before dispatch 2000 CFM / 60 mmwg St. Pressure
CEILING SUSPENDED AIR HANDLING UNITS WITHOUT HEATING COIL Supply, Installation, Testing and Commissioning of factory fabricated Indoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with 0.8 mm thick precoated galvanised sheet outside and 0.8 mm thick 275 GSM Galvanised Steel sheet inside with Backward curved direct driven plug type Metallic construction in supply with fan section with fan motor with IE2 rating and suitable for 415 plus 10%, 3 Phase, 50 Hz along with IP 20 VFD, 4 RD cooling coil with coil section, prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% before cooling coil, fine filter ( EU-7 / F7 ) / MERV-13 section with Synthetic fibre media with frame material made out by Aluminium anodized with flange rigid media with efficiency 99 % at 3µ (micron) in supply . The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor and belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU panel shall be insulated with 25 plus /-2 mm thick injected fire retardent PUF of density 40 plus /-2 Kg/m³ . The motor and fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling / heating coil, filters should not exceed 500 FPM. The capacities of airhandling shall be as follows NOTE: 1. Magnehelic differential pressure gauge required with fine filter and same shall be included in AHU. 2. AHU, Fans and Coil should be AHRI / EUROVENT Certified 3. Noise Level should not be exceed dB 55 @ 1 Meter 4. GA drawing and technical Data sheets should be get approval before dispatch 2500 CFM / 60 mmwg St. Pressure
CEILING SUSPENDED AIR HANDLING UNITS WITHOUT HEATING COIL Supply, Installation, Testing and Commissioning of factory fabricated Indoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with 0.8 mm thick precoated galvanised sheet outside and 0.8 mm thick 275 GSM Galvanised Steel sheet inside with Backward curved direct driven plug type Metallic construction in supply with fan section with fan motor with IE2 rating and suitable for 415 plus 10%, 3 Phase, 50 Hz along with IP 20 VFD, 4 RD cooling coil with coil section, prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% before cooling coil, fine filter ( EU-7 / F7 ) / MERV-13 section with Synthetic fibre media with frame material made out by Aluminium anodized with flange rigid media with efficiency 99 % at 3µ (micron) in supply . The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor and belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU panel shall be insulated with 25 plus /-2 mm thick injected fire retardent PUF of density 40 plus /-2 Kg/m³ . The motor and fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling / heating coil, filters should not exceed 500 FPM. The capacities of airhandling shall be as follows NOTE: 1. Magnehelic differential pressure gauge required with fine filter and same shall be included in AHU. 2. AHU, Fans and Coil should be AHRI / EUROVENT Certified 3. Noise Level should not be exceed dB 55 @ 1 Meter 4. GA drawing and technical Data sheets should be get approval before dispatch 3000 CFM / 60 mmwg St. Pressure
CEILING SUSPENDED AIR HANDLING UNITS WITHOUT HEATING COIL Supply, Installation, Testing and Commissioning of factory fabricated Indoor Type Double Skinned air-handling unit horizontal type with fabricated out of extruded aluminium (1.6 mm thickness min.)section with 0.8 mm thick precoated galvanised sheet outside and 0.8 mm thick 275 GSM Galvanised Steel sheet inside with Backward curved direct driven plug type Metallic construction in supply with fan section with fan motor with IE2 rating and suitable for 415 plus 10%, 3 Phase, 50 Hz along with IP 20 VFD, 4 RD cooling coil with coil section, prefilter (EU-4) section with non woven synthetic washable media of 10µ (micron) particle size with an efficiency of 90% before cooling coil, fine filter ( EU-7 / F7 ) / MERV-13 section with Synthetic fibre media with frame material made out by Aluminium anodized with flange rigid media with efficiency 99 % at 3µ (micron) in supply . The polished stainless steel drain pan of 1.25 mm thick duly insulated with 13 mm thick nitrile rubber under cooling coil shall be provided. Motor and belt drive package/ direct driven arrangement, belt guard etc for belt driven blower without face and bypass dampers. The AHU panel shall be insulated with 25 plus /-2 mm thick injected fire retardent PUF of density 40 plus /-2 Kg/m³ . The motor and fan assembly shall be mounted on aluminium extruded section .Marine light with limit switch shall be provided . The complete AHU shall conform to standard spec.The face velocity across cooling / heating coil, filters should not exceed 500 FPM. The capacities of airhandling shall be as follows NOTE: 1. Magnehelic differential pressure gauge required with fine filter and same shall be included in AHU. 2. AHU, Fans and Coil should be AHRI / EUROVENT Certified 3. Noise Level should not be exceed dB 55 @ 1 Meter 4. GA drawing and technical Data sheets should be get approval before dispatch 4000 CFM / 60 mmwg St. Pressure
INSULATED CHILLED / HOT WATER PIPING (Nitrile rubber insulation) - DSR: 16.2 `Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled / hot water piping inside the building (with necessary clamps, steel wire rope hangers/ vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive or Chemically cross linked polyethlyne foam of class``O``(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. and complete as per specifications including repairing of damage to building etc. and as required complete in all respect. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 200 mm dia.(32 mm thick insulation)
INSULATED CHILLED / HOT WATER PIPING (Nitrile rubber insulation) - DSR: 16.2 `Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled / hot water piping inside the building (with necessary clamps, steel wire rope hangers/ vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive or Chemically cross linked polyethlyne foam of class``O``(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. and complete as per specifications including repairing of damage to building etc. and as required complete in all respect. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 150 mm dia. (32 mm thick insulation)
INSULATED CHILLED / HOT WATER PIPING (Nitrile rubber insulation) - DSR: 16.2 `Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled / hot water piping inside the building (with necessary clamps, steel wire rope hangers/ vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive or Chemically cross linked polyethlyne foam of class``O``(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. and complete as per specifications including repairing of damage to building etc. and as required complete in all respect. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 125 mm dia.(32 mm thick insulation)
INSULATED CHILLED / HOT WATER PIPING (Nitrile rubber insulation) - DSR: 16.2 `Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled / hot water piping inside the building (with necessary clamps, steel wire rope hangers/ vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive or Chemically cross linked polyethlyne foam of class``O``(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. and complete as per specifications including repairing of damage to building etc. and as required complete in all respect. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 100 mm dia. (32 mm thick insulation)
INSULATED CHILLED / HOT WATER PIPING (Nitrile rubber insulation) - DSR: 16.2 `Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled / hot water piping inside the building (with necessary clamps, steel wire rope hangers/ vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive or Chemically cross linked polyethlyne foam of class``O``(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. and complete as per specifications including repairing of damage to building etc. and as required complete in all respect. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 80 mm dia.(32 mm thick insulation)
INSULATED CHILLED / HOT WATER PIPING (Nitrile rubber insulation) - DSR: 16.2 `Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled / hot water piping inside the building (with necessary clamps, steel wire rope hangers/ vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive or Chemically cross linked polyethlyne foam of class``O``(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. and complete as per specifications including repairing of damage to building etc. and as required complete in all respect. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 65 mm dia(32 mm thick insulation)
INSULATED CHILLED / HOT WATER PIPING (Nitrile rubber insulation) - DSR: 16.2 `Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled / hot water piping inside the building (with necessary clamps, steel wire rope hangers/ vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive or Chemically cross linked polyethlyne foam of class``O``(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. and complete as per specifications including repairing of damage to building etc. and as required complete in all respect. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 50 mm dia(32 mm thick insulation)
INSULATED CHILLED / HOT WATER PIPING (Nitrile rubber insulation) - DSR: 16.2 `Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled / hot water piping inside the building (with necessary clamps, steel wire rope hangers/ vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive or Chemically cross linked polyethlyne foam of class``O``(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. and complete as per specifications including repairing of damage to building etc. and as required complete in all respect. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 40 mm dia. (32 mm thick insulation)
INSULATED CHILLED / HOT WATER PIPING (Nitrile rubber insulation) - DSR: 16.2 `Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled / hot water piping inside the building (with necessary clamps, steel wire rope hangers/ vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive or Chemically cross linked polyethlyne foam of class``O``(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. and complete as per specifications including repairing of damage to building etc. and as required complete in all respect. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 32 mm dia(19 mm thick insulation)
INSULATED CHILLED / HOT WATER PIPING (Nitrile rubber insulation) - DSR: 16.2 `Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled / hot water piping inside the building (with necessary clamps, steel wire rope hangers/ vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class `O` insulation applied by suitable adhesive or Chemically cross linked polyethlyne foam of class``O``(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc. and complete as per specifications including repairing of damage to building etc. and as required complete in all respect. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 25 mm dia(19 mm thick insulation)
INSULATED CHILLED / HOT WATER PIPING (Expanded Polystrene insulation) - DSR: 16.3 `Supplying, laying/ fixing, testing and commissioning of followingnominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 80 kg/cum density resin bonded fiber glass or 144 Kg/ cu m density mineral wool (non Combustible) pipe section insulation covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing ltstrip(as per IS:1322 as amended up to date ) at joints and repairing of damage to building etc. as per specifications and as required. ` Note:- The Pipes of sizes 150mm and below shall be M.S. `C` class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 200 mm dia.(75 mm thick insulation)
Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class `O` applied by suiatable adhesive, as per specifications and as required complete in all respect.DSR : 16.5 32 mm
Supplying, laying, fixing, testing and commissioning of following thickness closed cell elastrometric nitrile rubber of class `O` applied by suiatable adhesive, as per specifications and as required complete in all respect.DSR : 16.5 19mm
INSULATED VALVES - DSR : 16.7 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal and O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified. DSR : 16.7.1 From and above 200 mm dia shall be with Gear operated 200 mm
INSULATED VALVES - DSR : 16.7 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal and O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified. DSR : 16.7.1 From and above 200 mm dia shall be with Gear operated 100 mm
INSULATED VALVES - DSR : 16.7 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal and O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified. DSR : 16.7.1 From and above 200 mm dia shall be with Gear operated 80 mm
INSULATED VALVES - DSR : 16.7 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal and O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified. DSR : 16.7.1 From and above 200 mm dia shall be with Gear operated 65 mm
INSULATED VALVES - DSR : 16.7 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal and O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified. DSR : 16.7.1 From and above 200 mm dia shall be with Gear operated 50 mm
BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation and PN 16 pressure rating for chilled / hot water circulation as specified. DSR : 16.7.2 80 mm
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified.DSR : 16.7.4 65 mm
`Supply, Installation, Testing and Commissioning of following sizes electronic, self- alancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve (PIDB / High Rangeability Valve) in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar Minimum. The modulating valves cost included with Digital Thermostat alongwith necessary wiring. DSR : 16.11.4 ` 50 mm
`Supply, Installation, Testing and Commissioning of following sizes electronic, self- alancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve (PIDB / High Rangeability Valve) in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar Minimum. The modulating valves cost included with Digital Thermostat alongwith necessary wiring. DSR : 16.11.4 ` 40 mm
`Supply, Installation, Testing and Commissioning of following sizes electronic, self- alancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve (PIDB / High Rangeability Valve) in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar Minimum. The modulating valves cost included with Digital Thermostat alongwith necessary wiring. DSR : 16.11.4 ` 32 mm
`Supply, Installation, Testing and Commissioning of following sizes electronic, self- alancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve (PIDB / High Rangeability Valve) in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar Minimum. The modulating valves cost included with Digital Thermostat alongwith necessary wiring. DSR : 16.11.4 ` 25 mm
`Supply, Installation, Testing and Commissioning of following sizes electronic, self- alancing, pressure independent type dynamic balancing valve with integrated 2 way modualating control valve (PIDB / High Rangeability Valve) in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm and above. Valves should have pressure rating of 25 Bar Minimum. The modulating valves cost included with Digital Thermostat alongwith necessary wiring. DSR : 16.11.4 ` 20 mm
Supply, Installation,testing and commissioning of Ball valves(full open port type) threaded type BSPT internal with Strainer with SS304 and 3mm perforated complete with heavy duty PN16 bronze forged body, chrome plated bronze ball etc.and as specified in standard specification 25 mm
Supply, installation, testing and commissioning of auto air vent valve with cock or ball valve of following sizes:- 15 mm dia auto air vent valve
Supply, installation, testing and commissioning of auto air vent valve with cock or ball valve of following sizes:- 25 mm dia auto air vent valve
Rectangular / Square Ducting ( Site fabrication ) - DSR:16.12.2 Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports/ steel wire rope hangers etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.00 mm sheet
`Supply , Installation, Testing and Comissioning of ducting made from aluminium sheet metal fabricated as per IS:655 and as per approved drawings and designs including the cost of hangers/ steel wire rope hangers, supports , angle , expansion fasteners , closed cell neoprene gasket TandP etc. as required of following gauge:- All as per pre approved by Engineer in charge. - ` 0.80mm (22 G)
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. - DSR:16.20 a) Fire damper
Drain Piping Supply and installation of Rigid UPVC piping complete with U trap, fittings, elbows, bends and supports / steel wire rope hangers as per specifications and duly insulated with 6 mm thick closed cell Nitril rubber with factory laminated 7 mil glass cloth or Chemically cross linked polyethlyne foam of class`O`(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc.as per specifications. 50 mm dia ( Working pressure - 6Kg/cm2)
Drain Piping Supply and installation of Rigid UPVC piping complete with U trap, fittings, elbows, bends and supports / steel wire rope hangers as per specifications and duly insulated with 6 mm thick closed cell Nitril rubber with factory laminated 7 mil glass cloth or Chemically cross linked polyethlyne foam of class`O`(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc.as per specifications. 40 mm dia (Working pressure - 6Kg/cm2)
Drain Piping Supply and installation of Rigid UPVC piping complete with U trap, fittings, elbows, bends and supports / steel wire rope hangers as per specifications and duly insulated with 6 mm thick closed cell Nitril rubber with factory laminated 7 mil glass cloth or Chemically cross linked polyethlyne foam of class`O`(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc.as per specifications. 32 mm dia (Working pressure - 10Kg/cm2)
Drain Piping Supply and installation of Rigid UPVC piping complete with U trap, fittings, elbows, bends and supports / steel wire rope hangers as per specifications and duly insulated with 6 mm thick closed cell Nitril rubber with factory laminated 7 mil glass cloth or Chemically cross linked polyethlyne foam of class`O`(XLPE) with Aluminium PE foil for as per given below pipe size. The joints shall be sealed with 50 mm x 1 mm thick self adhesive tape at the joints etc.as per specifications. 25 mm dia (Working pressure - 10Kg/cm2)
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. As per DSR - 16.13
Supplying and fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required. As per DSR 16.16
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core. As per DSR 16.17
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring and removable core. As per DSR 16.18
Duct Accoustic Lining Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. or anti-microbial Chemically cross linked polyethlyne foam of class`O`(XLPE)complete as required and as per specifications. As per DSR 16.21
Duct External Insulation Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class `O`) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation or anti-microbial Chemically cross linked polyethlyne foam of class`O`(XLPE) with Aluminium PE foil complete as per specifications and as required. Joints shall be sealed with self adhesive tape. 19 mm As per DSR 16.23.1
`Supplying and fixing of Underdeck insulation on RCC slab ceiling with approved sample of Class ``O`` closed cell Nitrile Rubber Insulation with 25 mm Thickness and density 40-55 Kg/Cum .Thermal Conductivity not exceeding 0.035 W/mK at an average Temperature of 0°C. Material shall have fire performance acc. to BS 476 Part 7 and Part 6, water vapour diffusion resistance ( µ factor ) shall be greater than 7000 and tested from third party for the parameteres.Insulation material shall be factory laminated with Aluminium Foil. `
Supply, Installation, testing and commissioning of Ball valves(full open port type) threaded type BSPT internal without Strainer complete with heavy duty PN16 bronze forged body, chrome plated bronze ball etc.and as specified in standard specification 40 mm dia.
Supply, Installation,testing and commissioning of Ball valves(full open port type) threaded type BSPT internal with Strainer complete with heavy duty PN16 bronze forged body, chrome plated bronze ball etc.and as specified in standard specification 25 mm dia.
Site fabrication GSS Duct - DSR: Item No.-16.12.2 Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet (24 Gauge) - DSR Item No.16.12.2.1
Site fabrication GSS Duct - DSR: Item No.-16.12.2 Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet (22 Gauge) - DSR Item No.16.12.2.2
DSR : 16.7 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal and O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified. DSR : 16.7.1 From and above 200 mm dia shall be with Gear operated.40 MM DIA
Supply,Installation, Testing and Commissioning of Air Cooled Modular type Reversible Heat Pump 36 TR Actual Cooling capacity ( plus /- 5% tolerance) comprsing of hermetic scroll compressors driven by suitable KW Sq.Cage induction motor complete with Shell and Tube type Evaporator duly insulated with 1 inch thick closed cell insulation material, Air cooled condenser made of copper tubes and aluminium fins , refrigerant piping, Refrigerant R410a and Oil (First Charge), Microprocessor based control panel and accessories etc, DOL starter,suitable for 400 V plus /- 10 % 3 Ph 50 Hz supply, Expansion Valve, Microprocessor based automatic and safety controls all mounted on a M.S. frame duly epoxy coated. Machine should be compact and moduler design to allow connection of multiple machines to make them behave as one unit and the overall set to continue working in case of breakdown of one module. Location:Panipat (Haryana) GA Drawing and Technical Data sheets should be get Approval before Dispatch Summer design conditions Ambient Temp : 43 Deg C Chilled water temperature In - 12.2° C (54°F) Chilled water temperature Out - 6.7° C (44°F) CHW Flow - 86 GPM Pressure drop not to exceed 20 feet Evaporator Fouling Factor - 0.0001 FPS IKW/TR at above design conditions not to exceed - 1.40 Winter design conditions Ambient Temp : 7 Deg C Hot water temperature In - 40 ° C Hot water temperature Out - 45° C Hot Water Flow Rate - 105 gpm Power input ( including fans) not to exceed - 46 kW Heating capacity = 135 - 140 KW `Matching highly efficient Cooler of Shell andTube type only. Refrigerant piping fittings, valves, accessories to inter connect compressor, condenser, chiller and expansion valve. Control panel with display comprising of Controls. It shall also be equipped with protection and monitoring devices such as H/L Pressure switch/ Thermal and Current Overload Protector DP/ Flow switches at inlet and outlet of chiller, water drain and air purge valves, wherever required. Rubber Below Flexible type with MS flanges at inlet and oulet connections of the evaporator. suction line and chiller insulation Frame work for mounting the above condenser, chiller, compressor and motor with base plate complete with antivibration pads/ springs.Initial/ first charge of refrigerant gas and compressor oil duly charged at factory. ` The package chiller shall be BMS compatible including necessary interface card suitable for transferring data to BMS. Chiller shall be provided with Rubber Bellow Expansion joints with MS Flanges for water connection in IN and OUT Required RCC Foundation with Antivibrartion Sandwitched type 12 mm thick Rubber Pads(18G sheet in between rubber pads for positioning of chiller (size shall be as per Manufacturer recommendation) Price shall be included of chillers port charges, port handling charges, other local duties, loading, transportation/insurance upto site, and all other taxes and incidentals complete till delivered at site. (Both Working )
CHILLED WATER PUMPS: Primary Circuit: Supply, Installation, Testing and Commissioning of Chilled Water duty centrifugal Vertical inline split coupled pumps with outside mechnical seal, complete with motor, drain valves and other accessories (except suction and discharge shut off valves, suction strainer, discharge check valves and drain piping which are covered under separate item). Pumps shall have mechanical seal and CI casing and Bronze Impeller, SS Shaft. The pump motor shall be of IE-3 class efficiency, TEFC Squirrel cage class -F insulation, suitable for 415 Volts ± 10%, 50 cycles, 3 phase power supply. The quoted price shall include cost of M.S supports for mounting both pump with motor and coupling guard etc. Pumps shall be complete as per specifications and shall have operating parameters as given below. The internal components of pumps including mechanical seal shall be suitable to sustain a temperature of 122°F. Pump shall be with PN-16 ratings.Vendor shall be provide with antivibration arrangement for pumps as per specification if applicable. Note:- Pump`s motor should be BMS Compatible Vendor shall be submit Pump performance curve and efficiency curve alongwith offer GA drawing and technical Data sheets should be get approval before dispatch The above mentioned pumps shall include following: 1 No.- Pump with minimum 58 - 60 % Efficiency 1 No. - Suitable HP TEFC squirrel cage induction type IE3 motor with class `F` insulation 1500 rpm synchronous speed, operating on 415 plus 10% volts, 3 phase, 50 Hz A.C. supply. Rubber Below Flexible type with MS flanges at inlet and oulet connections of the pump Lot- RCC Foundation with Anivibration pads. Water flow rate: 170 USGPM, Head : 24 mtrs Final Head furnished by vendor. The mentioned head is indicative purpose. (01 Working plus 01 Standby)
Dual Plate Type Wafer Swing Check Valves with Fittings like Flanges, Gaskets, Nuts and bolts, etc. suitable for PN-1.6 65 MM DIA
Water Flow Switch (Anergy/Honeywell)
Auto Air Purging Valve (Anergy)
Pressure Gauge 4` Dial (0 To 6 Kg/CM2)
6` StemType Thermometers (0 To plus 50OC) (Make: Fiebig/Guru)
SITC of open expansion tank of cap. 500 Litres duly insulated as per the specifications of CHW pipe insulation. (Make: Sintex/Polyplast)
`Supply, Installation, Testing and Commissioning of Intelligent Anti Fouling Condenser System with Anti Fouling arrangement on chiller by automatic condenser Tube cleaning System. The system shall be upto 04 numbers of Chillers at a time with a Common Skid for the required number of chillers in the plantroom. The system shall have one Injection/Collection pump, Motorized Valves, Energy Meter, Flow Meter, Temp. Sensors and complete with all accessories and Low side activities of piping connections of Ball traps and Ball collectors on the Chillers. The Common Skid piping, Ball Trap Size to suit chiller capacity requirement i.e. 03 Nos x 150 TR.`
Providing and fixing perforated cable trays (14 SWG) duly epoxy painted as per approved shades, complete with supports, tees, elbows, risers and all necessary hardwares etc. 450 mm x 40 x 40 x 2 mm thick
Providing and fixing perforated cable trays (14 SWG) duly epoxy painted as per approved shades, complete with supports, tees, elbows, risers and all necessary hardwares etc. 300 mm x 40 x 40 x 2 mm thick
Hemcool Engineers (BID ID -1240885)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .