HQ CWE PATHANKOT
SPECIAL REPAIR TO ELECTRIC SUPPLY SYSTEM AT SUB AREA CANTEEN COMPLEX UNDER GE (WEST) PATHANKOT
2025_MES_701354_1
CWE/P-69/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE WEST PATHANKOT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE WEST PATHANKOT
₹30,200
Yes
14 Jun 2025
13 Mar 2025
14 Apr 2025
13 Mar 2025
12 Apr 2025
28 Mar 2025
Amount
Supply,installation ,testing and commissioning of 200 kVA transformer step down outdoor type, 11/0.433 kV,(at no load),oil immersed confirming to IS 1180(PART-I) 2014 Energy Efficiency level-2 complete with standerd fittings copper wound 3 phase 4 wire 50 c/s oil immersed naturally cooled with external cooling tube ,delta connected on HT side and star connection on LT side with tapping on HT side to vary secondary voltage (+ )2.5 % to ( + ) 7.5 % in steps including first filling of transformer oil as per IS-1180 Part -I 2014 & BEE certified having dielectric strength not less than 50 kV on existing plateform, complete all as specified and directed. Note: (i) Routine test as per IS 1180 shall be carried out at the works.Type test including temperature rise test shall also be carried out at works .Site tests are also to be carried out in presence of company rep. All the tests whether at works/ at site are to be conducted in presence of MES rep and all test certificate duly signed by all concerned to be submitted by the contractor to the dept. (ii) The equipment should carry a guarantee of 30 months from the date of despatch or 24 months from date of completion of the contract ,which ever is later. Any defect during this period will be attended in a period of three days including spares and labour without any extra cost to Govt.
M&L for earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.225 meter deep below ground level ) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level the earth eletrode surounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on akk sides abnd including GI strip 32x 6 mm bolted ( with GI nuts , bolts & check nuts ) and riveted to earth (Plate) electrode at one end and connected to main swtich board / panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of each pit to top of electrode and 40 mm GI pipe meduim grade for earth strip protection complete with earth pit in PCC1:2:4 type B2 using 12 mm graded crushed stone aggregate, RCC cover, funnel , wire mesh including necessary excavation and earth work in any type of soil, returing filling in and removal of removal of surplus soil all as specified. Notes: 1. Earth strip & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels.
Supply testing laying/ fixing of 25 sqmm 4 core size XLPE insulated screened , pvc bedded, galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor alongwith wall/poles/roof etc using fixing accessories such as couplers, lock nuts, saddles pipe hook etc, including taking down of old UNSV cable, complete all as specified and directed.
All as per srl item No 4 above but for 16 sqmm 4 Core size.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, Bracke sketch fitting, ceiling roses, lamp holders, brackets, pendants, regulators, sockets, light fitting etc. removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by EIC. Note:- The damaged surfaces to be made good with plastering (1:6). & applying colour wash in required coats to matching with existing surfaces as directed by Engineer-in-charge. Cost of the same deem to be included in quoted rates and nothing extra on this account admissible.
M&L for Modular point wiring for one light/one fan controlled by one switch with 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS cable with and including PVC concealed conduit ISI maked heavy duty for one light fan/bell point controlled by one switch including Modular cover plate and modular metallic flush boxes of suitable way modular boxes and cover plates including PVC green insulated unsheathed 1.5 sqmm multistrand copper conductor FRLS cable as continous earthwire and connecting to earth duly, complete all as specified and directed. Note: (a) Insulation test of point wiring (b) colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
All as per Srl item No 7 above but for one 5 pin 5 Amp socket outlet point on inedpendent board controlled by one switch SP, one way 5 Amp, 240Volts.
All as per Srl item No 7 above but for one 5 pin 5 Amp socket outlet point on same board controlled by one switch SP, one way 5 Amp, 240Volts.
M&L for Modular point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable with in and including PVC concealed conduit heavy duty 20mm dia with all fittings including Modular cover plate and modular metallic flush boxes of suitable way modular boxes and cover plates suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed.
M&L for Modular point wiring with 4 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable with in and including PVC concealed conduit heavy duty 20mm dia with all fittings including Modular cover plate and modular metallic flush boxes of suitable way modular boxes and cover plates suitable for 5 pin 15 amps socket outlet/metal earth plug socket ,including 4 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface to match with the existingsurface complete all as specified and directed.
S&F Modular switch 1 way 6 A, 1 module complete all as specified and directed.
S&F Modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F Modular Socket 6A/ 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular Socket, 16A - 2/3 pin combined 2 module complete all as specified and directed.
S&F in replacement of existing unsv sheet metal enclosure with sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 20 amps 240 volts, complete with one single pole MCB of 20 amps 'C' curve complete all as specified and directed.
S&F lamp holder/ batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed.
M&L for ceiling rose, PVC/Polycarbonate, insulated body, surface Bakelite 65mm dia three terminals all as specified and as directed.
S&F of Modular Fan regulator 6A 1 module , complete all as specified and directed.
S&F LED Bulb B22 type ,14 watt white ,complete all as specified and directed.
S&F 20W surface / wall mounted batten LED luminair, extruded aluminium housing with PC diffuser and ind electronic driver with high efficiency long life, CRI = 80 (Minimum), PF > 0.95, luminous efficacy > 100 lumens/Watt operating voltage 140V-240V, CCT (K) > 6500, THD < 10% complete including 20W LED tube rod with all accessories internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed
S&F LED luminaire 600 mm X 600 mm , 35/36 watt 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver holder & driver & LED lamp suitable for roof ceilingincluding connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Taking down old unserviceable ceiling fan by disconnecting the electric connection and dismantling the blades and removing from ceiling/roof of bldg by descrewing the nut, bolt etc complete all as specified and refixing the same in existing position duly complete in all respect and as directed.
S&F of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 6 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification, complete all as specified and directed.
S&F MCB SP 240V, 50Hz, 10 KA, 'B' curve of rating 6 to 32 Amp, complete all as specified and directed.
S&F MCB SPN 240V, 50Hz, 10 KA, 'B' curve of rating 40 Amp, complete all as specified and directed.
S&F bldg secuirty light fitting energy saving high efficiency LED street light fitting 35 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 32 mm dia bent to shape having length on less than 1.5 mtr fixing with clamp etc and making connections using cord flexible 3 core copper cable of size 23/ .0076 from ceilling rose/ PVC connector to light fittings or, complete all as specified and directed.
S&F in replacement sub Main Wiring with two PVC insulated unsheathed multistrand FRLS flexible copper conductor cable of size 2x4 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 4 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed.
S&F in replacement sub Main Wiring with two PVC insulated unsheathed multistrand FRLS flexible copper conductor cable of size 2x6 sqmm and one PVC insulated multistrand unsheathed FRLS flexible copper conductor cable of size 6 sqmm (green colour) as earthing lead connecting to main earthing dolly drawn in and including non metallic PVC concealed conduit 20mm dia complete and making good to disturbed surface complete of wall/floor with cement mortar and finishes to match the existing surface complete all as specified and directed.
S&F in replacement of old unsv sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB FOUR POLE 100 AMPS AC 415 VOLTS 25 KA=01 NO as incoming and 12 nos. MCB SP 40 Amps, C series as outgoing (Note :- (i)The DB shall be VTPN series of Schenieder Cat Part No:- A9HVD04L or equivalent in any of the make mentioned in list of product . (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(iv) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (vi) MCCB's and MCB's should have a same make as of DB.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (Earth pit not less than 2.25 metre deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as showin in electrical plate No.5 of SSR Part-I (2009) including filling of charcoal dust, common salt all around Earth plate upto 150 mm, 20mm bore GI medium grade watering pipe, 15 mm bore light grade earth lead protection pipe upto main board, funnel with wiremesh, 40 mm thick RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregrate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including test on completion. Notes: 1. Earth strip & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. 3. Soil shall be free from stone, boulders, aggregate, gravels.
Notes: The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum.
JAI DURGA CONSTRUCTION CO (BID ID -3277035)
dadwal engineers (BID ID -3281002)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .