Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹5.9 L+₹25,232 (4.43%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹6.6 L+₹89,988 (15.8%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹6.7 L+₹1.0 L (17.9%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT ADMITTED |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
26 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) (AF) Chimney Hills, Bangalore
Asst Garrison Engineer I AF Chimney Hills Chikkbanavara Post Bangalore, PIN- 560 090
REPAIRS TO EXTERNAL ELECTRIC SUPPLY SYSTEM TO OTM AND MD ACCN AT 58 SU AF STATION CHIMNEY HILLS
2020_MES_382483_1
8396/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE (I) (AF) Chimney Hills, Bangalore
As per tender documents
8 documents required · 8 mandatory
₹500
AGE (I) (AF) Chimney Hills, Bangalore
₹12,000
Yes
26 Mar 2021
6 Oct 2020
28 Oct 2020
6 Oct 2020
26 Oct 2020
13 Oct 2020
6 Oct 2020 - 12 Oct 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified. Note : A deduction of 10% shall be made from total computed volume of filling to cater for bulkage irrespective of machinery used for ramming.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as directed.
Supply, laying, jointing, testing and commissiong LT under ground, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, heavy duty electric cables with stranded aluminium conductor 1100 volts grade confirming to IS, laid in trenches, ducts, passing through pipes or fixed to wall with suitable clamps/saddles etc., including cable glands, terminal socket and connecting of size 2 Core x 10 Sqmm including taking out/down old damaged/unserviceable LT UG XLPE cable complete all as specified and as directed.
All as per item No. 4, here in before but for LT UG XLPE cable of size 4 Core x 10 Sqmm including taking out/down old damaged/unserviceable LT UG XLPE cable complete all as specified and as directed.
All as per item No. 4, here in before but for LT UG XLPE cable of size 4 Core x 16 Sqmm including taking out/down old damaged/unserviceable LT UG XLPE cable complete all as specified and as directed.complete all as specified and as directed.
All as per item No. 4, here in before but for LT UG XLPE cable of size 3.5 Core x 35 Sqmm including taking out/down old damaged/unserviceable LT UG XLPE cable complete all as specified and as directed.complete all as specified and as directed.
All as per item No. 4, here in before but for LT UG XLPE cable of size 3.5 Core x 95 Sqmm including taking out/down old damaged/unserviceable LT UG XLPE cable complete all as specified and as directed.complete all as specified and as directed.
Supply and laying common burnt clay, building bricks, sub class 'B' designation 75 and laid in trenches for cable protection as specified and directed.
Supply and spreading in layers, clean, dry, fine stone dust in trenches for cable cushioning to LT UG cable all as specified in clause 19.75 of SSR part -I complete all as specified and directed
Supply and laying galvanised steel pipe 25mm bore dia light grade including all fittings complete laid in trenches or in floor, for road crossing/fixed on wall/on pole for protection of LT UG cables all as specified and as directed
All as per item No. 11, here in before but for galvanised steel pipe 50mm bore dia all as specified and as directed
All as per item No. 11, here in before but for galvanised steel pipe 80mm bore dia all as specified and as directed
Supply and fix straight through heat shrinkable jointing kit suitable for 3.5/4 Core, 25 to 95 sqmm LT UG cable 1100 Volts complete all as specified and directed
All as per item No. 14, here in before but suitable for 3.5 Core, 120-185 Sqmm LT UG cable 1100 Volts complete all as specified and directed
All as per item No. 14, here in before but suitable for 3.5 Core, 240-400 Sqmm LT UG cable 1100 Volts complete all as specified and directed
Supply and fix in replacement of Air circuit breaker with microprocessor release IPR1 + 4 pole, 1250 Amps, 415 volts, 50 KA breaking capacity, electrical operated and fixed type complete all as specified and directed. Make : Havells/L&T/Seimens
Supply and fix in replacement on load change over switch gear in sheet metal encloser, rated current 400 Amps capacity, 4 pole complete all as specified and directed.
Supply and fix in repairs MCCB 04 Pole, 25 to 100 Amps, 415 Volts, 50 Hz, breaking capacity 16 KA, fixed TM range, including spreader links on both sides complete all as specified and as directed.
All as per item No. 19, here in before but, 125 Amps, breaking capacity 16 KA complete all as specified and as directed.
Supply and fix in repairs MCCB 04 Pole, 200 Amps, 415 Volts, 50 Hz, breaking capacity 36 KA, adjustable thermal setting, including spreader links on both sides complete all as specified and as directed.
All as per item No. 21, here in before but, 250 Amps, breaking capacity 36 KA complete all as specified and as directed.
All as per item No. 21, here in before but, 400 Amps, breaking capacity 36 KA complete all as specified and as directed.
M/S SRI BALAJI ENTERPRISES
Sri Lakshmi Venkateswara Enterprises
ANAND REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .