| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹13.8 L+₹25,062 (1.85%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
2 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (AF) Shillong
GE (I) (AF) Shillong Elephant Falls Camp PO Nonglyer Shillong-793009
CA NO. GE(I)(AF)/SHL/ 2022-23 REPAIR TO CLEANING OF SEWAGE SYSTEM INCLUDING SEPTIC TANKS, MANHOLES AND OTHER SEEWAGE RELATED WORKS AT AF STATION LATIKOR PEAK UNDER GE (I) (AF) SHILLONG
2022_MES_516711_1
8011/22/SHL/2022/23
Open Tender
Civil Works - Others
Item Rate
270 days
LAITKOR PEAK SHILLONG
For Enlisted Contractors Class E Category a ii and for unenlisted contractors meeting enlistment criteria for required Class and Category
7 documents required · 7 mandatory
₹500
GE (I) (AF) Shillong
₹30,000
Yes
23 Jun 2022
5 Apr 2022
4 May 2022
5 Apr 2022
2 May 2022
19 Apr 2022
5 Apr 2022 - 12 Apr 2022
60 days
Amount
Note : All unserviceable materials obtained out of demolition/dismantling/taking down (other than those for which credit catered under Schedule of credit) shall be disposed of outside MoD Land. Quoted rates against respective item shall deemed to include for same.
Demolition of brick work/PCC block masonry or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thickness below or above ground level and removal all rubbish material complete all as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) in any position not otherwise specifically provided for and removal all rubbish material complete all as directed.
Taking down chowkats with shutters (without taking off shutters from the frames) & removing from site area exc 1.5 Sqm & n. exc 4.00 sqm each complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Refixing/Repair/Fixing of hardware of joinary items viz, door/window handles, tower bolt, hinges, door stopper, door closer, mesh, glass, bedding/putty, nails, plywood et complete all as specified and directed. Note : 1. Contractor shall resolve the complaint within 48 hours after the requirement has been notified. 2. If contractor fails to attend the complaint within 48 hours then a penal recovery shall be charged as under:- Delay after 48 hours (a) one day - Rs. 500/- (b) Two days - Rs 1000/-, (c ) Three days and more - Rs 1500/-
Dismantling of PVC(SWR) drain pipe alongwith fittings and accessories and taking out from walls, floors or from trenches, if required complete all as specified and directed for following sizes:- (Note :- The length shall be measured along the centre line including fittings and accessoires}.
75mm dia
110mm dia
Dismantling of cast iron (sand cast) soil, waste and vent pipe upto 100mm bore alongwith fittings and accessories jointed in cement mortar and taking out from walls, floors or from trenches, if required including removing vegetation growth around pipes as required, making good surface to match with existing including necessary scaffolding complete all as specified and directed. (Note :- The length shall be measured along the centre line including fittings and accessoires).
Demolition and breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar including PCC bedding and haunching etc complete all as specified and directed.
150mm bore SGSW pipe
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, pipe lines etc. in soft/ loose soil, complete all as specified & directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3m in depth or not exc 10sqm on plan & getting out for foundation etc or for shafts wells, cesspits, manholes pier holes, sewage line etc in soft / loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in soft / loose soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for precast cement concrete block masonry 1:3:6 Type C-1 using 20mm graded stone aggregate with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M & L for cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in lintels upto 1.5m clear span, steps, seismic and other similar bands, bed plates, road side kerbs, coping/cills, bed block for embedding hold fast etc including necessary form work, weathering, slightly rounded or chamfered angles and throating complete all as directed.
M & L providing precast cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces joint as directed and setting in CM 1:4 complete all as specified and directed. (Note :- Reinforcement shall be measured and paid for separately under respective items of the BOQ.)
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto complete all as specified and directed.
M & L for TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with mild steel square tube, In opening complete all as per specifications and drawings as applicable to item 08095 given in SSR Part – II (2010).
S & F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppy and fixing in the frame at site complete all as per specifications and drawings as applicable to item 08080 given in SSR Part–II.
S & F butt hinges, medium weight, colled rolled mild steel & ISI marked complete all as specified and directed for following sizes:-
100mm long.
S & F 100mm long aluminium anodized barrel tower bolt of extruded section ISI marked complete all as specified and directed.
S & F 100mm size extruded aluminium alloy handles, fabricated type, anodised, ISI marked complete all as specified and directed.
M & L for 25 mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate as in levelling coarse of floors, surfaces finished even and fair complete all as specified and directed.
M & L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in sub base complete all as specified and directed.
M & L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes complete all as specified and directed.
M & L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
M & L for Pavement floor vitrified tiles of size 300x300x10mm thick (Endura tiles of Johnson or equivalent makes listed in List of Makes) set, jointed and pointed in neat cement slurry and pointed with grey cement and pigment to match the colour of tiles in floor complete all as specified and directed.
M & L for 15mm thick rendering in CM 1:4 on stone masonry surfaces or on other than fair faces of brick masonry surfaces, finished even and smooth without using extra cement complete all as specified and directed.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed for following sizes:-
75mm bore
110mm bore
S & F PVC (SWR) bend of any radius with oval access door complete all as specified for following sizes:-
75mm bore
110mm bore
S & F in repairs PVC (SWR) bend of any radius with oval access door complete all as specified for following sizes:-
75mm bore
110mm bore
S & F cast iron(sand cast), soil, waste and vent pipe in any length with or without ears with cement joints , fixed to wall complete all as specified and directed for following sizes :-
75 mm dia
100 mm dia
S & F cast iron(sand cast), soil, waste and vent pipe in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed for following sizes:-
75 mm dia
100 mm dia
S & F in repairs PVC (SWR) junction, single (single T) equal or unequal complete all as specified and directed for following sizes:-
75 mm dia
110 mm dia
S & F in repairs PVC (SWR) Nahani trap 75mm dia outlet with stainless steel grating suitable for floor trap including jointing to waste pipe fixed in cement concrete 1:2:4, type B-1 complete all as directed.
M & L for salt glazed stoneware drain pipes grade 'A' ISI marked 150mm internal diameter laid in trenches and jointed complete all as directed.
M & L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in bedding to SGSW/NP-2 drain pipe of any dia including packing under and haunching against the sides of the pipes after they are laid and tested complete all as specified and directed.
S & F in repairs vitreous China squatting pan (Orissa pattern) water closet (white) of size 580 mm x 440 mm with integral foot rests, 'P' or 'S' trap, including connection to trap, flushing pipe and antisyphonage pipe etc and including provision of PCC (1:5:10) type E-2 lean concrete in filling, making good to floor (excluding flushing cistern and flush pipe etc) complete all as specified and directed.
S & F in repairs white Vitreous china wash down water closet pan (pedestal pattern) including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device including flush pipe and fixing bolts (excluding flushing cistern) etc complete all as specified and directed.
Cutting in to existing manholes / septic tank for connecting new drains making good to 150mm/200mm bore pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and pipe reforming benching as required complete all as specified and directed.
Cleaning away all grass vegitation, saplings, shruss, brush wood, under growth , roots and trees not exceeding 15 cm girth(measured one metre above ground level) and removing rubbish upto a distance of 50 mtr all as directed by the Engineer-in-Charge.
M & L for cleaning and clearing of blocked pipe between floor/nahani trap and Gully trap or between water closet and First Manholes by removing accumulated sludge/mud including cleaning and clearing of floor/nahani trap and Gully trap or water closet and First Manholes on either side and disposing off the accumulated sludge/mud, excavating pit and safely buried the same in pit, top portion of pit covered with soil and excess soil spreaded evenly or removed to a distance not exceeding 50m, appllying bleaching powder @ 1 Kg/Sqm of covered area to maintain hygine complete.
Cleaning and clearing of underground sewage line (including manholes by taking off manholes covers and re-fixing the same after cleaning) of any description, underground and any depth by removing any type of blockage including de-silting and de-choking cleaning of blockage manually by rodding and removing the silt/sludge & other deposits and transporting the same in covered van/trolley for disposal at place as directed, excavating pit and safely buried the same in pit, top portion of pit covered with soil and excess soil spreaded evenly or removed to a distance not exceeding 50m, appllying bleaching powder appllying bleaching powder @ 1 Kg/Sqm of covered area to maintain hygine complete. Note for item Nos. 42.00 & 45.00 : 1. Contractor shall clean within 48 hours after the requirement has been notified. 2. If contractor fails to attend and removev blockage within 48 hours then a penal recovery shall be charged as under:- Delay after 48 hours (a) one day - Rs. 1000/- (b) Two days - Rs 2000/-, (c ) Three days and more - Rs 5000/-
M & L for cleaning and clearing of existing septic tanks any size/depth by bailing out effluent, removing the silt/sludge & other deposits mechanically with combined high pressure water jetting cum suction (vacuum) type machine mounted on LCV/HCV and having facilities of high pressure water thermoplastic fiber braided water jetting hose and through conical/round shape nozzle pipe and flushing after cleaning and removing the silt/sludge & other deposits and transporting the same in covered van/trolley for disposal at place as directed, excavating pit and safely buried the same in pit, top portion of pit covered with soil and excess soil spreaded evenly or removed to a distance not exceeding 50m, appllying bleaching powder appllying bleaching powder @ 1 Kg/Sqm of covered area to maintain hygine and writing particulars of cleaning done with synthetic enamel paint on septic tanks complete all as directed. (Notes :- (i) Volume occupied by silt/sludge & other deposits (Semi solids) shall only be measured and paid for against the item. (ii) Volume occupied by effluent (liquid above silt/sludge & other deposits) shall not be measured and paid. However quoted rates shall be deemed to be includde for bailing out of effluent.)
M/S INSHA ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .