Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.6 LAccepted-Finance | ₹66.6 L | L1 | Accepted-Finance Lowest Bidder |
| 2 | L2₹66.7 L+₹5,042.90 (0.08%)Rejected-Finance | ₹66.7 L+₹5,042.90 (0.08%) | L2 | Rejected-Finance Second Lowest Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Under clause 4.4 A b of ITB of section 2 , Clause 1.3.1 of section 3 under Clause 8 a of NIT under clause 4.4. B b i of Appendix to ITB , clause 4.4 B a ii of ITB of Section 2 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Under section 2 clause 4.4 B a ii of ITB , Under clause 4.4 A b of ITB of section 2, Clause 4.4 B b i of Appendix to ITB, Clause 32 32.5 of ITB of section2 and clause 50 g of Part 1 of General conditions of contract of section 4, clause 4.4 |
| Sl No | Description | Qty | Unit | M/s Lohit Nguba H2 | shri Dakke Nyicyor H1 |
|---|---|---|---|---|---|
| 1.00DEVELOPMENT OF SITE | |||||
| 1.01 | Excavation in Soil by Manual Means .
Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres. | 943.64 | Cum | 271.72 ₹2,56,405.86 Lowest | 271.72 ₹2,56,405.86 Lowest |
| 1.02 | Excavation in Ordinary Rock by Manual Means
Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with in all lifts and leads upto 1000 metres | 1,415.46 | Cum | 375.88 ₹5,32,043.1 Lowest | 375.88 ₹5,32,043.1 Lowest |
| 1.03CONSTRUCTION | |||||
| 1.04 | Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders up to 30 cm size, saturated soil and rock), lift up to 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m. | 105.85 | Cum | 334.29 ₹35,384.26 Lowest | 334.92 ₹35,450.95 |
| 1.05 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete. | 254.52 | Cum | 1,178.5 ₹2,99,956.53 | 1,178.05 ₹2,99,842 Lowest |
| 1.06 | Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering. | 108.85 | Cum | 5,986.59 ₹6,51,628.35 Lowest | 5,986.59 ₹6,51,628.35 Lowest |
| 1.07 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centering, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). | 23.86 | Cum | 10,871.38 ₹2,59,445.48 Lowest | 10,871.83 ₹2,59,456.22 |
| 1.08 | Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement | 46.99 | Cum | 921.09 ₹43,281.1 Lowest | 921.09 ₹43,281.1 Lowest |
| 1.09 | Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size). | 55.53 | Cum | 12,480.7 ₹6,93,003.35 Lowest | 12,480.7 ₹6,93,003.35 Lowest |
Tender Value
₹66.8 L
EMD Value
₹66,850
Closing Date
1 Sept 2025, 9:00 amClosed
EE, RWD Likabali
O/o EE RWD Likabali Lower Siang District AP
Government Inter village (IV) school at Yachugi in Lower Siang District, Arunachal Pradesh
2025_RWDAP_2679_1
(2025-26)/Gensi/2
Open Tender
Civil Works
Item Rate
Lower Siang
Please refer Tender documents.
5 documents required · 5 mandatory
₹15,000
Yes
EE RWD Likabali
₹66,850
Yes
Likabali, Lower Siang
20 Sept 2025
18 Aug 2025
1 Sept 2025
18 Aug 2025
1 Sept 2025
18 Aug 2025
18 Aug 2025 - 25 Aug 2025
25 Aug 2025
Amount
DEVELOPMENT OF SITE
Excavation in Soil by Manual Means . Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres.
Excavation in Ordinary Rock by Manual Means Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with in all lifts and leads upto 1000 metres
CONSTRUCTION
Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders up to 30 cm size, saturated soil and rock), lift up to 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centering and shuttering.
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centering, shuttering and reinforcement in :a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc and removal of form work for :a) Foundation, footings, bases of columns etc. and mass concrete.
Reinforcement of RCC work including bending, binding and placing in position complete.a) Mild steel bars.
Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architecturaldrawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) :
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick &2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge.Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar each 591.90
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.b) Ornamental grill.
Providing approved best available local wood (Class-B-II) work in frames of doors, Windows clearestory Windows and other frames.
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.a) 300 x 16 mm
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
12 mm cement plaster 1 : 6 (1 cement : 6 fine sand).
15 mm cement plaster 1 : 6 (1 cement : 6 fine sand) on the rough side of single or half brick wall.
Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
ELECTRIFICATION
SUB-HEAD-1 (WIRING)
Rates of only ISI marked M.S. conduit, FR PVC insulated copper conductor single core cables, moulded plate type switches in passivated box and FR PVC insulated earth wire have been taken in the following items unless otherwise specified and as per specification.Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as requiredWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper.Light Points conductor single core cable etc. as required.Light Points
Group A
Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Fan pointsGroup B
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
i)2 x 1.5 sq. mm
ii)2 x 6 sq. mm
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
SUB-HEAD-II (FITTINGS & ACCESSORIES)
ERRECTION OF FANS & LIGHT FIXTURES
Supply and fixing circular/ hexagonal M.S. sheet ceiling fan box with clamp of internal dia 140mm, 73 mm height, 3mm thick rim top lid of 1.5mm thick M.S sheet lidss shall be screwed into M.S. box by means of 3mm round headed screws, clamps shall be made of 12 mm dia M.S bar bent to be shape as per standard drawing with over all length as 80 cm
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supplying and fixing PVC batten/ angle holder including connections etc. as required
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
SUPPLY OF FANS & LIGHT FIXTURES
Light/fan fixtures :-
Supply and of following type fluorescent/CFL fixtures shall be complete with Electronic Ballast, PF improvement capacitor, Control gear box. Bipin Rotor type lamp holder, starter, starter base, all pre wired upto the terminal block. All fixtures shall be supplied with lamps.(make Philips or equivalent/Wipro/Thron).1 x 18 W FTL, Wall mounted type indoor light fixture
Supplying and of 1200 mm sweep ceiling fan with 300/600 mm standard down rod and electrical connection as required etc.Exhaust fans
Supply of heavy duty type exhaust fans of following size sweep with gravity louvers shutters including all accessories/installation materials required make HAVELS/USHA.450 mm sweep 900 rpm
Providing and supplying of Cashing bit of size 50mm thick
SUB-HEAD-III (DB's AND MAIN SWITCH)
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 A TP&N
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).6 way , Double door
supplying and fixing 5A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker,Single pole and neutral
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 A
SUB-HEAD-IV (EARTHING)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
LIGHTENING PROTECTION
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for vertical run)
Providing and fixing testing joint, made of 20 mm x 3 mm thick gi strip, 125 mm long with 4 Nos. brass bolts, nuts check nuts and spring washers etc. complete as required.
Providing and laying GI tape, 32 mm x 6 mm thick from earth electrode directly in ground as required.
BUBASR BOX-WALL MOUNTED.Busbar 200Amp, 4P, 25kA, Aluminium busbars Outgoing,4 Nos. Holes in 3 phase and Neutral busbar with hardwares suitable for outgoing cable connections upto 4Cx16 Sqmm Al Arm Cable.BUBASR BOX-WALL MOUNTED as described above
Meter Box Connection
M/s Lohit Nguba (BID ID -7889)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .