Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 CrAccepted-AOC | ₹23.0 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹24.8 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹24.8 Cr | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹18 Cr
EMD Value
₹15 L
Closing Date
25 Mar 2023, 6:00 pmClosed
Chief Engineer Navy Visakhapatnam
CHIEF ENGINNER NAVY STATION ROAD VISAKHAPATNAM
PROVISION OF DEFICIENT SINGLE SAILOR LIVING ACCOMMODATION APPROX 157 MEN AND ALLIED FACILITIES FOR JUNIOR SAILORS AT INS ADIYAR CHENNAI
2023_MES_578736_1
88742
Open Tender
Civil Works
1095 days
ADIYAR CHENNAI
AS PER NIT
8 documents required · 8 mandatory
₹3,000
Assistant Garrison Engineer (I), Navy, Chennai
₹15 L
Yes
16 Nov 2023
2 Feb 2023
27 Mar 2023
2 Feb 2023
25 Mar 2023
7 Mar 2023
Amount
Schedule "A" Part – I to Schedule "A" Part – XVIII: NOTE: Schedule "A" Part – I to Part – XIX are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES", as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "SITE CLEARANCE / SITE DEVELOPMENT/ EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "PILE FOUNDATION ", as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "ROADS /PATH/HARD STANDING/CULVERT", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "RAIN WATER HARVESTING", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for"LIFT ", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for "DG SET", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for "FIRE FIGHTING", as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for "SOLAR WATER HEATER", as listed in Schedule "A" Part – XV
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION", as listed in Schedule "A" Part – XVI
Lumpsum price worked out by the contractor for "TV/TELEPHONE", as listed in Schedule "A" Part – XVII
Lumpsum price worked out by the contractor for "WATER COOLER/ AIR CONDITIONING", as listed in Schedule "A" Part – XVIII
Schedule "A" Part - XIX: [Miscellaneous Items] [Pile Foundation, Internal Electrification, Site clearance/site development/ earth work/ exacavaton, External Water Supply, External Electrification, Road/Path/ Culvert/Hard standing, Area Drainage, Sewage disposal, Fire fighting system, Lifts, Aviation Light, DG Set, Refrigeration/ Air conditioning/ RO water Purifier, lightening protection and TV/Telephone ]
PILE FOUNDATION
450 mm dia Boring for Bored cast in chiselling/ cutting through for boring for cast in situ piles in soft rock and getting out and disposal of spoil to a distance 50 metres complete all as specified and as directed.
600 mm dia Boring for Bored cast in chiselling/ cutting through for boring for cast in situ piles in soft rock and getting out and disposal of spoil to a distance 50 metres complete all as specified and as directed.
450 mm dia Boring for Bored cast in chiselling/ cutting through for boring for cast in situ piles in hard rock and getting out and disposal of spoil to a distance 50 metres complete all as specified and as directed.
600 mm dia Boring for Bored cast in chiselling/ cutting through for boring for cast in situ piles in hard rock and getting out and disposal of spoil to a distance 50 metres complete all as specified and as directed.
Controlled Concrete, M35 Grade, Design Mix [using 20 mm graded stone aggregates] as in piles and complete all as specified and as directed. Note:- Pile shall be casted as mentioned in drawings. However, for payment purpose the length of pile shall be measured up to cut off level only. The unit rate/ Lumpsum price quoted shall be deemed to include this aspect.
Carrying out Initial load [Compression] test on 450mm dia piles, complete all as specified and directed.
Carrying out Initial load [Lateral] test on 450mm dia piles, complete all as specified and directed.
Carrying out Initial load [Compression] test on 600mm dia piles, complete all as specified and directed.
Carrying out Initial load [Lateral] test on 600mm dia piles, complete all as specified and directed.
Carrying out routine load test [Compression] on 450mm dia piles, complete all as specified and directed.
Carrying out routine load test [Lateral] on 450mm dia piles, complete all as specified and directed.
Carrying out routine load test [Compression] on 600mm dia piles, complete all as specified and directed.
Carrying out routine load test [Lateral] on 600mm dia piles, complete all as specified and directed.
Carrying out initial pullout test on 450mm dia piles, complete all as specified and directed.
Carrying out initial pullout test on 600mm dia piles, complete all as specified and directed.
Carrying out low strain integrity test on 600mm dia piles including analysing the results complete all as specified and directed.
Carrying out low strain integrity test on 450mm dia piles including analysing the results complete all as specified and directed.
M&L for MS pipe liner fabricated out of 6mm thick plain MS plate confirming to Fe-410 S by welding the joints, strengthening wherever required, providing stiffners, lifting hooks including all T&P required, shifting the same from position to positions required, driving in true vertical alignment in position to the required level for piles complete, all as specified and directed. Note: MS Pipe liner shall be casted as mentioned in drawing. However for payment purpose, the depth of pile liner shall be measured up to cut off level only irrespective of the depth provide for retaining concrete/ bentonite slurry. The unit rate/lumsum price quoted shall be deemed to include for the above aspect.
Internal Electrification
All as per Serial Item No. 37 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per Serial Item No. 37 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
All as per item No.37 here-in-before but controlled by two two way switch complete all as specefied and directed.
Supply and fixing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] without remote including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed.
Supply and fix LED lamp 07 watts CDL complete all as specified and as directed.
Supply and fixing exhaust fan, 250mm sweep, sturdy engineering plastic body, heavy duty with louvers, AC single phase, 230 volts, 50 Hz, 1200 RPM, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
Supply and fixing exhaust fan, 300 mm sweep, metallic body, 900 RPM heavy duty with louvers, AC single phase, 230 volts , connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
Supply and fixing smart three phase four wire dual source prepaid energy meter BIS 15884 marked in existing meter board/ floor panels with pre payment capacity touch keypad based digital having current range 10-60 Amps, 415 Volts, accuracy class 1.0 alongwith parallel home display split unit with in-built load control switch, containing provision for TOD and RTC, in-built feature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tarrif slabs, happy hours and holiday definition complete all as specified and as directed.
S & F LED security light fitting with tube 10 Watts new generation energy saving & environmental friendly long life versatile, pressure die cast aluminium luminiare with mid power LED as lighting source and HF electronic driver, pre-wired and connecting up with with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade bracket of 32 mm dia bend to shape for fixing on wall/ pole with suitable MS bracket nuts, bolts etc., complete all as specified and directed.
S & F MCCB DB, vertical double door, TPN, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of CCB FP 40 Amps, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surface complete all as specified and as directed.
M & L for sub-main wiring with 6.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 6.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 25 mm dia PVC conduit complete all as specified and as directed. Note :(i) Two run of 6.0 Sqmm + one run of 6.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for sub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 20 mm dia PVC conduit complete all as specified and as directed. Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick GI strip [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth strip upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relavent item.
Supply and fix mirror light LED type 10 watts 2 feet long complete all as specified and as directed.
SEWAGE DISPOSAL/ ROAD/PATH/HARD STANDING/ AREA DRAINAGE
Removal of excavated surplus soil outside MD land complete all as specified and directed.
S&F Precast factory made SFRC Cover extra heavy duty [rectangular] of Grade [EDH-35] conforming to IS 12592-2002, set in cement mortar (1:4) including cover complete all as specified and directed.
External Electrification
M&L for LT made out of powder coated CRCA sheet 3.15 mm thick CPRI approved outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear including nuts/ bolts etc., to be made of rust proof material including tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, 400 Amps capacity busbar confirming to IS 8623 complete with necessary internal electric connection as required, provision and including the following.
M&L for LT made out of powder coated CRCA sheet 3.15 mm thick CPRI approved outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear including nuts/ bolts etc., to be made of rust proof material including tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, 400 Amps capacity busbar confirming to IS 8623 complete with necessary internal electric connection as required, provision and including the following.
Supply and fix weather proof cable junction box suitable for outdoor installations with knockout cable entry, looping in box PVC of size 155mmx210x92 mm comprising of connector -01 No including mounting arrangements and lugs etc. complete all as specified and as directed.
Supply and fix GI bracket made made out of 40 mm dia medium grade GI pipe 1.2 metre long bent to angle 135 degree along with suitable size clamps, bolts, nuts etc., including painting with two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and as directed.
M & L for Submain wiring with 1.5 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 1.5 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through suitable dia PVC conduit complete all as specified and as directed. Note :(i) Two run of 1.5 Sqmm + one run of 1.5 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
External Water Supply
M&L for cutting the existing 80 mm dia GI pipe for additions and alterations including necessary fittings and fixtures complete all as specified and as directed.
Supply, install testing & commissioning of submersible pump of 7.5 HP capacity, electric driven, 415 Volts, TP suitable for UG Sump of 40 metre head including all fixing arrangements complete all as specified and as directed.
M&L for LT FPB made out of powder coated CRCA sheet 2.00 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear including nuts/ bolts etc., to be made of rust proof material including tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, over load protection with adjustable relay complete with necessary internal electric connection as required, provision and including the following.
Supply and lay flat submersible cable of size 10 Sqmm 3 core, PVC insulated industrial cable, with multi stranded copper conductor, 1100 Volts grade suitable for submrsible pump complete all as specified and as directed.
M & L for 100 mm dia ductile iron pipe spigot and socket type centrifugally cast (spun) all as per IS:8329-2000, Class K9 including provision of specials, such as tee's, elbows, bends, reducers, taper pieces and jointing material complete all as specified and directed.
DG SET
Supply and installation of silent Diesel Engine driven generating set 75 KVA, 415 volts, 3 phase, 4 wire, with multifunctional panel having overload/short circut/ low oil/ engine over speed/ water/ oil empty indicator and alarm system and AMF panel with onload auto changeover of load, engine and Alternator as per IS complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms fitted with complete retrofit system and foundation as specified by OEM and Engineer in Charge etc with and including the following; (a) 12 Volt battery along with copper connecting lead. (b) Fuel storage tank with fuel pipe (c) Multi functional panel having the following safety features from over load / short circuit over /under voltage, low lube oil /engine over speed /water and oil temperature with indication & alarm system. (d) Digital Voltmeter, Ammeter, frequency meter, RPM indicator, KWH meter & hour meter. (e) DG set will be enclosed in a factory made Acoustic canopy as per ISI. Note: (i) The rate includes the cost of foundation and all necessary civil work as per manufacturer drawing. (ii) The rate includes the cost for 12 Hrs load test as specified, including diesel and provison of load for testing. (iii) Contractor shall handover user manual, tools kit, test certificate of manufacturer.
M&L for LT made out of powder coated CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear including nuts/ bolts etc., to be made of rust proof material including tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, 400 Amps capacity busbar confirming to IS 8623 complete with necessary internal electric connection as required, provision and including the following.
Fire fighting System/ Fire Alarm
Supply, install, testing & commissioning of 2 way fire brigade inlet connection of wet riser consisting of two Nos 63 mm bore instantaneous stainless steel male coupling with cap and screwed by chain, two Nos, built in stainless steel Non return valves and one No. 100 mm butterfly valve as per BS 5155 including suitable MS cabinet made out of 3 mm thick MS sheet with front door having 3 mm thick glass panels and locking arrangements suitably mounted on wall including painting with two coats of postal red synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
Supply and fixing CP hose pipe 63mm internal dia 30 metre length as per IS 8423 with hose coupling gun metal 63 mm heavy duty pair of male and female coupling on either sides of hose pipe complete all as per IS 903 as required for the site in each floor complete all as specified and directed.
Supply, install, testing & commissioning of fire pumps control panel made out of CRCA sheet 2 mm thick with 63 Amps, 3 phase, 4 wire, 500 Volts and provision for fixing starter complete all as specified and directed.
Supply and fixing fully automatic star delta starter 15 HP complete all as specified and directed.
Supply and fixing perforated GI cable tray of size 100x50x1.6mm thick including mounting accessories and painting with synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for MS channel structural steel support made from wall and from floor hitek supports made out of MS channels sections for fixing of MS pipe in wall/roof complete all as specified and directed.
Supply and fix 6kg fire extinguisher dry chemical powder [ABC] type complete all as specified and directed.
Supply and fix 4.5kg fire extinguisher Co2 type complete all as specified and directed.
Supply and fix 9kg/ litre fire extinguisher water stored pressure type complete all as specified and directed.
Supply and fix MS rectangular fire bucket stand with canopy for accommodate 04 Nos fire buckets duly with two coats of postal red synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
Supply and fix 9 litre fire extinguisher mechanical foam type complete all as specified and directed.
M & L for wiring with 1.5 sqmm nominal area one single core PVC insulated unshethed multi-stranded FRLS copper conductor cable drawn through 20 mm dia PVC conduit complete all as specified and as directed. Note :(i) One run of 1.5 Sqmm + one run of PVC conduit shall be measured as an one Unit.
TV/ TELEPHONE
S & F telephone socket [JACK TYPE] RJ 11-1 with shutter module complete with all accessories complete all as specified and directed.
S & F TV co-axial socket 1 module complete with all accessories complete all as specified and directed.
REFRIGERATION/ AIR CONDITIONING/ RO WATER PURIFIER
Supply and fix refrigerator, electric driven [single phase], doulbe door not less than 300 litres, BEE, 5 star rated complete all as specified and directed.
Supply and fix power unit for 1.5/2 tonne capacity AC including electri connections complete all as specified and directed.
Supply and fix RO + UF + TDS water purifier to remove chemicals, salts, viruses and other dissolved impurities, purification capacity not less than 20lts/hr and not less than 8 litres capacity storage glass body/plastic body complete all as specified and directed.
Design, Supply, Install, Testing and Commisioning of Passenger Lift, with capacity of 8 Nos. passangers, Speed 1.5 metre/sec, Lift with single speed motor 415 Volts, 3 Phase, AC 50Hz supply conforming to IS-14665, suitable to serve G + 10 upper floors with AC Variable Voltage and Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (Electric motor driven mechanism), sliding stainless steel doors, Automatic Rescue Device(ARD) System (with+/-5mm with suitable dry maintenance free battery, automatic power operated Centre Opening & Sliding stainless door of 16 gauge with 3D infrared sensor in full height of door and built-in announcing system without hand set (03 Nos, One each in car, machine room and Near Ground floor landing door) complete all as specified including necessary joists for mouting machine in machine room and all civil works required with erecion of lift incl auto fan, LED lights, emergency lights all as specified . The lift shall be provided with and including the following:- (a) Alarm speaker for alarm system to be fixed, stop button in car with rechargeable arrangement for battery, (b) Four sleek circular LED lights fitting in false ceiling, (c) Overload warning indicator both audio and visual type with tripping system having relay etc. (d) Set of three Nos limit switches at the bottom and top most position of lift. (e) Display indicating panel, power control cables (f) Testing of Govt approved lift inspector (h) Marking on lift's pit and lift room (i) Mirror of 6mm thickness of suitable size on one wall inside the car
(k) Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed on all the floors) and stop button in car with rechargeable arrangement for battery. (l) Aluminium chequered plate (3mm thick) as flooring. (m) Car size shall be conforming to IS-3534-1976 and body to be of stainless steel of 16 gauge mirror finish with stainless steel hand rail (n) Front door, operations with a minimum time of 10 seconds and upto a maximum timeof 30 seconds. (o) Hand rail, Specification plate (p) Wire rope of adequate size as per relevant IS and as per manufacturer specification (q) Suitable earthing pit earthing of lift as per IS and as required technically. (r) One sleek circular PVC heavy duty fan in false ceiling. (s) Fire man switch (t) Automatic rescue device during power failure with capacity of battery designed for 45 minutes including manual operation provision (u) Other standard fixtures and fittings like guide rails, sheaves, counter weight with guard, buffers, gears, brakes, control panel, motor, locks, governor, car operational panel, power control and trailing cables complete. Note :- The rate quoted shall be Including the rate for comperhensive maintenance period for two years after completion of the work.
All as per Serail Item No.84 here-in-before for suitable for 13 passengers (884 Kgs) with all accessories/ connected items should be suitable for 13 Nos passengers (884 Kgs)
M & L for cutting existing road/PCC/drain of size 150 mm wide 230 mm deep for laying under ground cable making good to match with the existing surface with PCC 1:3:6 type C1 [using 20 mm graded stone aggregate] including necessary earth work complete all as specified and as directed.
Aviation Light
Supply and fix Aviation obstruction light LED type 60 W including standard fixing arrangements complete all as specified and as directed
Supply and fix LT panel out door type for street light comprising of Astronomical time switches 415 volts, single phase, 20 Amps MCBs, 32A TP Contactor including fixing accesories complete all as specified and as directed. Make: Cat No. IHXTS0306A of Havells or its equivalent in Philips/Bajaj/Wipro/GE
SCHEDULE 'A' PART-XX PHASE -II OUTSOURCING OF 8 & 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 84 & 85 DURING FIRST YEAR OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8 & 13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year during Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XXI PHASE -III OUTSOURCING OF 8 & 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 84 & 85 DURING SECOND YEAR OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8 & 13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year during Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XXII PHASE -IV OUTSOURCING OF 8 & 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 84 & 85 DURING FIRST YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8 & 13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year after expiry of Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XXIII PHASE -V OUTSOURCING OF 8 & 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 84 & 85 DURING SECOND YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8 & 13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year after expiry of Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XXIV PHASE -VI OUTSOURCING OF 8 & 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 84 & 85 DURING THIRD YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8 & 13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 3rd year after expiry of Defect liability period complete all as specified and as directed.
Notes for item Nos. 89 & 93 : (i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge. (ii) The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 Hours and Second Shift shall be from 1430 Hours to 2230 Hours. (iii) In case of non function of passenger lift, the Goods Lift installed in the same building shall be operated as directed. (iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 2 to 3 years items under BoQ shall be deemed to be including the same. (v) The unit rate is deemed to include for maintaining log books, record of repair /replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors. (viii) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc.
(ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job. (x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same. (xi) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. "Name of the firm and designation" on front and on the back of the T-shirt along with protective clothing/ gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. (xii) INSURANCE: The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations.
SCHEDULE 'A' PART-XXV PHASE -VII FIRST YEAR COMPREHENSIVE MAINTENANCE OF 8 & 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 84 & 85 AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+10 upper floors all as mentioned vide SI No. 84 of BOQ during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts (844 Kgs) to serve G+10 upper floors all as mentioned vide SI No. 85 of BOQ during 1st year after expiry of defects liability period all as specified and directed
SCHEDULE 'A' PART-XXVI PHASE -VIII SECOND YEAR COMPREHENSIVE MAINTENANCE OF 8 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 86 AFTER EXPIRY OF DEFECT LIABILTY PERIOD..
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 84 of BOQ second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 85 of BOQ second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
SCHEDULE 'A' PART-XXVII PHASE -IX THIRD YEAR COMPREHENSIVE MAINTENANCE OF 8 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 86 AFTER EXPIRY OF DEFECT LIABILTY PERIOD..
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 84 of BOQ, third year after expiry of defects liability period and After completion of second year Comprehensive Maintenance.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 85 of BOQ, third year after expiry of defects liability period and After completion of second year Comprehensive Maintenance.
Note for SL No: 94 to 99:- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation. (iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engr -in-Charge. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid