Commissioner, Dindigul City Municipal Corporation
9/13, Main road, Corporation Office, Dindigul
Construction of class rooms at Paraipatti School
2023_MAWS_367560_7
853 / 2023/ E4
Open Tender
Civil Works
Works
90 days
paraipatti school
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹31,000
Yes
14 Sept 2023
7 Sept 2023
14 Sept 2023
7 Sept 2023
14 Sept 2023
7 Sept 2023
Amount
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand, silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water wherever necessary refilling the sides of foundation with excavated soilother than sand in layers of 15cm thick well rammed and completed, cleaning and levelling the site etc.,complete - Narrow Foundations - Upto 2.00m Depth
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel, stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand, silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water wherever necessary refilling the sides of foundation with excavated soilother than sand in layers of 15cm thick well rammed and completed, cleaning and levelling the site etc.,complete - Open Earth Work excavation
Supplying and filling in foundation and basement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBGmetal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation - Plinth Beam
Centering for soffits of RCCslabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm clc )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/c) complying with standard specification and directed - For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCCboxing, etc.
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BGstiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13cm dia spaced at not more than 75cm centre to centre etc. complete complying with the standard specificaiton. - For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
Providing and laying in position Standardised Concrete Mix M- 20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCCitems of works with minimum cement contenet of 325KgI cum and maximum water cement ratio of 0.55 including admixture (Plasticiser I super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCCfloor I roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarseand Fine aggregates to be used should comply with the requirements of IS standards. - Upto Basement
Supply and fabrication of steel required for all RCC items of works involved in the schedule, cost of steel at site fabrication, labour charges for cleaning the rods straightening, cutting, bending, tying grills, including overlapping to the required length whenever necessary and placing the reinforcement in position as as per design given and specified in the drawings, including cost of binding wire, provision of spacer bars, cover blocks and all other incidental charges etc complete as per standard specification
Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9"X43/8"X23/4"standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessaryfor obtaining required elevation shall be done without extra cost) - Upto Basement
Brick work in CM 1:5 (one cement & Five Crushed Stone Sand (M- Sand)) using II class ground moulded bricks of size 9"X43/8"X23/4" standard specification including finishing, curing, etc., complete complying with standard specification (Masonry projections wherever necessaryfor obtaining required elevation shall be done without extra cost) - Ground Floor
Manufacturing supplying and fixing of MILD STEELWindow made out of 40 x 40 x 6 mm M.Sangle for outer frame, 35 X 35 X 5mm M.S.Anglefor outer frame of shutter. The entire shutter area shall be covered with CRC sheets (18 G) with 5Nos,of stiffners using M.S.Flats of size 25 X 6mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash butt welding or any other suitable method. rovisiontowards 3Nos, of Hinges incase of single shutters / 6Nos,of Hinges incaseof Double shutters of 125 X 31 X 1.25mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop lNo. The frame shall be provided with 6Nos,of Hold fast of 200mm length using 50 X 6mm M.S.Flat.The entire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemendal officers. (The rate is inclusive of cost of dismantling the masonry or making holes in R.C.Cand redoing the same to the original condition) - Size 0.90 X 1.20m
Fabricating Supply and fixing and position of MS doors with single leave. The door outer frame will be 40x40x6mm MS angle, the shutter frame will be 35x35x6 mm, MS angle intermediate stiffner will be 35x35x6 mm with cross stiffner 25x 25x5 mm flats covered with 18 gauge M.S. sheet with necessary hinges, tower bolts, aldrop length 30mm and hold fast etc., complete with one coat red oxideprimer. - Size 1.00 X2.10m
Special ceiling plastering in all floors and finishing the exposed surface of RCCitems of work such as slab, beam, sunshade, facia, canopy slab, staircase waist slab, landing slab etc., with cement mortar 1:3 (One cement and three plastering sand (PSand)) 10mm thick including hacking the surfaces and providing cement mortar noslnq, beading for sunshade, staircase, step, landing slab etc., including neat finishing and curing etc., complete complying with standard specification and as directed by the departmental officers.
Plastering with cement mortar 1:5 (One cement and five plastering sand (P- Sand)) 12mm thick in all floors including cost and conveyance of all materials to site etc,complete as per standard specflcatlons
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32:12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers etc., complete as per standard specification.
Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three plastering sand (PSand)) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete
Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement
Dadooing walls with Glazed tiles of sizes 305mm X 200mm X 6mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P- Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed.
White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. -100sq.m S.I.333
Painting two coats of newly plastered wall surface with approved cement paint over cement plastered wall surface, ceiling and including preparing the surface, clean removal of dirt and including necessary plaster of parts putty wherever required and cost of painting materials, brushes, preparation of surfaces and scaffolding charges etc., complete complying with standard specflcatlon and as directed by the departmental officer
Painting the new iron work with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat and including cost of painting materials, brushes, putty, preparation of surfaces and scaffolding charges etc., complete complying with standard spedtlcation and as directed by the departmental officer.
Supplying and filling the basement with Carted Good Earth 5Km away from the site and filling in layers of not more than 15cm thick well rammed watered and compacted - etc., complete complying with standard specification.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Providing& fixing PVC RAIN WATER DOWN FALL PIPE of 110mm dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with adepth of 110mm. The pipe is to be fixed by means of "U" clamps at the centre of pipes to be fixed.ll0mm dia PVCPipe [4 Kg/SqCm]
Solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for paneling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm, with suitable rebate for housing the shutter and should have provision to fix AL drops, tower bolt hinges and lock plates inclusive of cost of all materials etc. complete complying with thew standard specifications.
Providing and fixing louvered ventilator fabricated from roll formed sections made of galvanized steel colour coated or reported they still as per IS 513 D quality galvanized as per IS 277 with the zinc of 120 grams per sqm) with the total coated thickness of Paint specification: court at sections should be with primer court of epoxy primer of 5-7 microns thick, Finish painted with polyester paint of 12 - 16 microns thick, Dimensions of the sections: the section for external frame should be 57 mm x 33 mm Fixing details: the section should be cut to length joint with profile to profile component Accessories: glass holding planes made of glass filled nylon Glass: louveres to be provided with 4 mm pin headed glass Grill: ventilator should be provided with grill made of 10 mm square MS bar to 12 mm x 5mm flat at 4 inch intervals. Total grill unit should be powder coated and fix it to ventilator frame with screws.The frames should be fixed to brick or concrete / Masonry walls and floor by means of self expaning screws
Supplying and fixing in position best approved of BIS quality PVC Waste water pipes having a pressure of 6 kg. / sq.cm including cost of special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 6.0 meter pipe length, etc., complete complying with standard specification.
110mm dia pipe
90mm dia pipe
Supply and delivery and fixing of HDPE tank as per IS 12701 / 1996 including loading,unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., 1000 litres capacity
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
25mm Gun metal Gate Valve
32mm Gun metal Gate Valve
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
SD Tap
Pillar Tap
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.
Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges up to 4 meter height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works.
Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements
Coupler
25 mm Dia
32 mm Dia
Elbow
25 mm Dia
32 mm Dia
25 mm Dia
32 mm Dia
25 mm Dia
32 mm Dia
End Cap
25 mm Dia
32 mm Dia
Reducer
20 mm x 15 mm
25 mm x 20 mm
32 mm x 25 mm
Reducer Tee
20 mm x 15 mm
25 mm x 20 mm
32 mm x 25 mm
Reducer Elbow
20 mm x 15 mm
25 mm x 20 mm
32 mm x 25 mm
Jet Nipple
25 mm Dia
32 mm Dia
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
PVC Elbow
110mm dia
75mm dia
PVC Elbow with Door
110mm dia
75mm dia
PVC Tee
110mm dia
75mm dia
PVC Tee with Single Door
110mm dia
75mm dia
PVC "Y" with Single Door
110mm dia
90mm dia
Supplying and fixing in position Indian Water Closet (Oriya type) of size 580 x 440mm White/Color glazed earthen ware of approved quality and brand with "P" or "S" trap conforming to BIS with Sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two Sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of Sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three Sand ) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
Providing rain water harvesting using 3 No.of RCC well rings of 90cm inner dia (clear) with 5cm wall thickness made out of cement concrete 1:2:4 using 20mm hard broken jelly to a height of 30cm each supplying and fabricating 16 No. of 6mm dia MS rod vertically and 3 No. of 6mm dia MS rod circumferentially tied together with 18 guage binding wire for well rings including necessary earth work excavation 1m dia to a depth of 1m, supplying and filling 40mm HBG inside the erected well ring to a depth of 90cm, and top covered with RCC circular perforated cover slab of 1m dia and 5cm thick which inclusive of cost and fabrication of 6mm M.S reinforcement at 15 cm spacings on both directions and one 6mm M.S rod ties at the edge of the slab circumferentially including cost of moulding, curing, finishing and well placing in position and disposing off excavated earth with all initial leads and lifts in places as shown by the Departmental officers etc., complete in all respects.
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVCinsulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoriesinflush with wall with 3mm thick hylum sheet cover with TW switch box and SA F.T. switch with continuous earth wire connection of 14 SWGTC wire for making good of the concealed portion with suitable colour for PVCconcealed light point / Fan point (For Electronic regulator). SD23
Wiring with 2 x 1.5 sqmm (22 /0.3 ) PVCinsulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories inflush with wall with 150 x 100 x 113 mm TW switch box with 3mm hylum sheet cover for 5A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWGTC wire and making good of the concealed portion with suitable colour for concealedPVCplug point. SD38
Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVCrigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour. SD54
Supply and fixing of single box type 4'36 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVCunsheathed Copper leads from terminals to the fitting SD87
Supplying and fixing of 1200mm ( 48" ) sweep AC ceiling fan complete with regulator with 1M down rod including S & F of fan clamp with side plates and crossarm SD 107
Earthing as per P.W.D. standard with an earth electrode of 2Mtr. Class'B' GI pipe of dia not less than 32mm complete with necessarymasonry work.SD 234
Supply and fixing of 3 phase4 wire 4 way ICDBof 32 A per way with 100 A TPN MCswitch with suitable trunking box Ms cable entry boxes and internal connection on suitable angle iron frame work with earth connection SD. 175
Supply and fixing of Horizontal type 4 way triple pole neutral MCBdistribution board in sheet steel enclosure with 40 A 4 pole MCBisolater as incoming and 12 Nos. 6A to 32 A SP MCBas outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDBand MCB'sshould be with the lSI mark (lik standard make) SD.179
Supply and run of 2 of No.8 SWG GI wire for guarding with cradle with No.8 SWG GI wire at the equal interval of 1.5m SD.75
Supply and run of 4 X 6 sq.mm (84/0.3) 7/20sqmm PVC unshealed copper cable in suitable PVCrigid pipe concealed on wall and ceiling withcontinuos earth wire connection of 14 SWG TC wire with painting of suitable colour SD68
Geophysical survey charges
Drilling of bore well 150mm dia in any kind of soil or hard rock for a requiring depth using rig heavy duty compressorr equipment mounted on a vehicle including conveyance of all items to site Fuel cost, labour charges and with one supporting vehicle complete etc.
Supply and fixing of 180 mm dia PVC casing pipe
Labour charges for inserting PVC casing pipes assembly in the drilled hole including jointing pipe etc. competed as directed by the Departmental officer
Supply and laying of 32mm HDPE hose pipe
Supply and laying of 25mm HDPE hose pipe
Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 %
Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/ 50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately).
Labour charges for the erection of 6HP submersible pumpset in borewell/openwell including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter,Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
Supply and laying of 4sq.mm. 3core PVC insulated and sheathed flat type copper cable conforming to IS 694/1990
G UDAYAKUMAR
stage.html
html • 0.02 MB
finance_438315.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .