Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹76,400Qualified Make: kent
Model: kent 25 lph 218A NEMI SAGAR COLONY VAISHALI NAGAR JAIPUR DAUSA RAJASTHAN 303326 | DAUSA | RAJASTHAN | 303326 | Make: kent
Model: kent 25 lph | L1 | Qualified | |
| 2 | L2₹76,840+₹440 (0.58%)Qualified Make: kent
Model: kent 25 lph 181 SATYA APARTMENT SANGRAM COLONY C SCHEME JAIPUR RAJASTHAN 302001 | JAIPUR | RAJASTHAN | 302001 | Make: kent
Model: kent 25 lph | L2 | Qualified | |
| 3 | L3₹77,156+₹756 (0.99%)Qualified Make: kent
Model: kent 25 lph GURJAR KI THADI JAIPUR RAJASTHAN 302020 | JAIPUR | RAJASTHAN | 302020 | Make: kent
Model: kent 25 lph | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
29 Jun 2018, 6:00 pmClosed
Potable water purification system Potable Water Purification System ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier Ultraviolet (UV) LAMP Yes Yes
No Ultra Voilet (UV) Lamp power consumption 600 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 1 INPUT PARAMETERS Input Water TDS 1000 1000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 25-35 25-35
30-40
90-100
70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - Output water capacity (Litre/Hour): 25 25 Arsenic and Floride removal capability false 1/3 Misc
warranty etc Thin-film composite membrane Yes Yes
No High Pressure Pump Yes - Raw water/Chemical Raw water/Chemical Cleaning PUMP No Yes
No Pre Filter Vessels: Yes Yes
No Micron Filter Yes Yes
No Membrane Housing Yes Yes
No Auto cut Yes Yes
No No of candles (Nos) 3 Installation Type Wall mounted Wall mounted Warranty period ( for free replacement of machine 2 2
3
1 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2
1 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes Yes Chloride & Flouride removal facility No No Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 - - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Udai Raj Meena 321611
GOVT COLLEGE TODABHIM
BIRAI KA THADA
PADLA ROAD
TODABHIM-321611 2 15 EMD 2/3 Required No ePBG Required No
255560
GEM/2018/B/36323
Potable water purification system
15 days
Rajasthan; Karauli
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Potable water purification system Potable Water Purification System ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier Ultraviolet (UV) LAMP Yes Yes | - | - | - |
| No Ultra Voilet (UV) Lamp power consumption 600 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 1 INPUT PARAMETERS Input Water TDS 1000 1000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 25-35 25-35 | - | - | - |
| 30-40 | - | - | - |
| 90-100 | - | - | - |
| 70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - Output water capacity (Litre/Hour): 25 25 Arsenic and Floride removal capability false 1/3 Misc | - | - | - |
| warranty etc Thin-film composite membrane Yes Yes | - | - | - |
| No High Pressure Pump Yes - Raw water/Chemical Raw water/Chemical Cleaning PUMP No Yes | - | - | - |
| No Pre Filter Vessels: Yes Yes | - | - | - |
| No Micron Filter Yes Yes | - | - | - |
| No Membrane Housing Yes Yes | - | - | - |
| No Auto cut Yes Yes | - | - | - |
| No No of candles (Nos) 3 Installation Type Wall mounted Wall mounted Warranty period ( for free replacement of machine 2 2 | - | - | - |
| 3 | - | - | - |
| 1 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2 | - | - | - |
| 1 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm Yes Yes Chloride & Flouride removal facility No No Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 - - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Udai Raj Meena 321611 | - | - | - |
| GOVT COLLEGE TODABHIM | - | - | - |
| BIRAI KA THADA | - | - | - |
| PADLA ROAD | - | - | - |
| TODABHIM-321611 2 15 EMD 2/3 Required No ePBG Required No | - | - | - |
Exempted
29 Jun 2018
26 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_255560.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .