| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L1 | Accepted-AOC Being lowest reasonable | |
| 2 | L2₹14.1 L+₹94,886 (7.24%)Rejected-Finance 45 PIR BABA TARUSHAW ROAD HALWARA AD LUDHIANA 141106 | HALWARA | LUDHIANA | PUNJAB | 141106 | L2 | Rejected-Finance Being not lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Past of the firm unsatisfactory |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
21 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Halwara
GE (AF) Halwara
REPAIR AND MAINT OF COOLING APPLIANCES IN TECH AND DOMESTIC AREA AT AF STN BARNALA UNDER GE AF HALWARA
2020_MES_405859_1
GE/HAL-65/2020-21
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS E CATEGORY b i
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹28,000
Yes
13 Feb 2021
22 Dec 2020
23 Jan 2021
22 Dec 2020
21 Jan 2021
6 Jan 2021
60 days
Amount
M&L for servicing and cleaning of window / split type AC unit of any size/capacity by removing dust with suitable method, cleaning of air filters, tightening of loose wire, nuts, bolts, washers, servicing of condenser motor/blower by oiling/ greasing, welding/bracing as required, replacement of worn out rubber bushes of condensor motor, setting of grill alignment & knobs, checking for any leakages, provision of thermocoal for air tightness, testing etc complete all as specified and directed.
Supply and fix in replacement blower motor Single shaft, suitable for Split type AC 1.5/2 Ton single ended or double ended shaft as per existing one complete all as specified and directed.
Supply and fix in replacement blower motor double shaft, suitable for window type AC 1.5/2 Ton single ended or double ended shaft as per existing one complete all as specified and directed.
Supply and fix in replacement out door fan motor suitable for Split type AC 1.5/2 Ton out door unit single ended or double ended shaft as per existing one complete all as specified and directed
Removing the unserviceable compressor from window type AC and supply and fix new compressor suitable for 1.5 Ton window type AC of original manufacturer/authorised dealer under replacment scheme all including fixing in original position including gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge. Note : (i) Purchase vouchers and gurantee of one year of compressor from the original manufactuers/authorised dealers shall be obtained and submitted by the Contractor while claming payment of compressors under replacement scheme. (ii) Credit of old compressor as per credit sch shall be deducted.
Removing the unserviceable compressor from Split type AC and supply and fix new compressor suitable for 1.50 Ton Split type AC of original manufacturer/authorised dealer under replacment scheme all including fixing in original position including gas charging, pressure testing, cleaning, condensing and cooling coils, welding, bracing and also including required length of capacity tube and strainer/filter and painting of base plate complete all as per existing one and as directed by Engr-in-Charge.
All as per Sl item No 6 here-in-before but for 2.00 Ton Split type AC
Shifting of window/Split type A/C, any type / any capacity, any make with necessary addition / alteration to window / wall complete all as specified and directed by Engr - in - charge.
Dismantling of cooling coil for repairs of 1.5/2 Ton capacity window type/split type AC made up of copper tubing and copper/aluminium cooling fins including brazing, welding etc , replacement of copper/aluminum tubing/fins with new one as per site requirement, refixing in original position and testing etc complete all as specified and directed by Engr in charge.
S&F in replacement of starting capacitor of 80 to 120 Mfd, 50 Hz , suitable for 1.5/2 Ton capacity AC.
S&F in replacement running capacitor 36 to 60 Mfd 50Hz , suitable for 1.5/2 Ton capacity AC.
S&F in replacement of capacitor 3 to 6 Mfd ,50Hz suitable for condenser motor of 1.5/2 Ton capacity AC.
S&F in replacement over load protector suitable for 1.5 /2 Ton capacity AC.
S&F in replacement starting relay box type suitable for 1.5/2 Ton capacity AC
S&F in replacement of thermostat suitable for Window/Split 1.5/2 Ton capacity AC.
M&L for blower motor blade suitable for Window Type AC 1.5 TR in replacement complete all as specified and directed.
M&L for blower motor blade suitable for Split Type AC 1.5/2 TR in replacement complete all as specified and directed.
S&F in replacement of Electronic Power Control Box ( LED Display) for window type AC 1.5 TR complete all as specified.
S&F in replacement of Electronic Power Control Box (LED Display ) with Remote for Split Type type AC 1.5/2.00 TR complete all as specified.
M&L for Evaporator unit (cooling coil) for window type AC 1.5 Ton capacity in replacement with and including brazing fixing etc complete all as specified and directed.
M&L for Evaporator unit (cooling coil) suitable for Split type AC 1.5 Ton capacity in replacement with and including brazing fixing etc complete all as specified and directed.
M&L for Evaporator unit (cooling coil) suitable for Split type AC 2.0 Ton capacity in replacement with and including brazing fixing etc complete all as specified and directed.
M&L for copper discharge tube of size 3/8" , duly nylon insulated in replacement complete all as specified and directed.
M&L for copper suction tube of size 5/8" duly nylon insulated in replacement complete all as specified and directed
M&L for copper discharge tube of size 1/4" , duly nylon insulated in replacement complete all as specified and directed.
M&L for copper discharge tube of size 1/2" , duly nylon insulated in replacement complete all as specified and directed.
M&L for blade of condensor fan motor for window type AC of capacity 1.5/2 Ton as in replacement complete all as specified and directed.
S&F sheet metal enclosure, single pole neutral enclosure with a two pin and earth metal clad plug top and socket in repairs complete with one Single pole and neutral MCB 20 A, 240 V complete all as specified and directed.
Wiring for circuit / sub main wiring alongwith earth wire with 2 x4.0 Sqmm size PVC insulated unsheathed 1100 volts grade single core stranded ( multistrand ) copper conductor cable (FR) cable in surface/recessed as required in PVC casing caping including PVC casing & caping including its all necessary fittings and accessories, one continuous run of PVC insulated unsheathed 2.5 sqmm stranded copper conductor cable as earth wire and connected to earth dolly, complete all as specified and directed by Engr in charge. Note- Two run of wire 4 Sqmm and one run of wire 2.5 sqmm drawn in casing & caping will be measured as one length for the purpose of payment.
Tracing out leakage from suction line, discharge line, evaporation condenser, filter, capillary tube by suitable method including bracing, welding, replacement of filter strainer charging line and filling of gas as directed by Engr-in-Charge, again testing of AC any capacity/ make for leakage proof and refixing in position complete as directed by Engineer-in-Charge.
S&F in replacement front grill of window type A/C of capacity 1.5 / 2 Ton as directed by Engr-in-Charge.
S&F Voltage stabalizer 5 KVA copper Wound suitable for Window/split type AC 2 TR including installation as in replacement complete all as specified.
S&F Voltage stabalizer 4 KVA copper Wound suitable for Window/split type AC 2 TR including installation as in replacement complete all as specified.
S&F in replacement of pencil type driers made in brass heavy duty suitable for window/split type ACs complete all as specified.
S&F in replacement of pin Valve /gas charging Valve suitable for window/split type ACs complete all as specified.
S& in replacement Copper caplary tube size 0.34 to 0.80 inch complete all as specified and directed.
Supply only Brass Nuts (1/4" Dead Nuts )
Supply only Flair Brass Nuts (1/2" Nuts )
Supply only Flair Brass Nuts (1/4" Nuts )
Supply only Flair Brass Nuts (5/8" Nuts )
Supply only Copper Pipe Insulation size 1/2"
Supply only Butane Cartage 414 ml Gas for Brazing/welding AC
Supply only Bakalight Connector ( for ACThree Connection )
Supply only Gas 134-A in small cartage 450 Grams each
Supply only Copper Pipe Insulation size 1/4"
Supply only Copper Pipe Insulation size 5/8"
Supply only Brass Thimble for AC compressure (100 Piece packet )
Supply only Copper Brazining Rod
Supply only self adhesive taps (Brown Cello Tape) size 50mm X 30 mtr complete all as specified.
Supply only PVC insulation tap 25 mm X 25 mtr complete all as specified.
Drain PVC pipe, 25 mm bore 2.5 M in length with two Nos mild steel clamps necessary brass screws as in replacement and complete specified and directed.
Supply only Copper caplary tube size 0.34 to 0.60 inch complete all as specified.
S&F in replacement of starting capacitor of 50+6 Mfd, 50 Hz , AC suitable for 1.5/2 Ton A/C
S&F in replacement of starting capacitor of 45+6 Mfd, 50 Hz , AC suitable for 1.5/2 Ton A/C
S&F in replacement of starting capacitor of 45+2 Mfd, 50 Hz , AC suitable for 1.5/2 Ton A/C
S&F in replacement Blower for indoor split AC As per Existing complete all as specified.
M&L for copper Condenser unit (cooling coil) in replacement suitable for window type AC 1.5 Ton capacity with and including brazing fixing etc complete all as specified and directed.
M&L for copper Condenser unit (cooling coil) in replacement suitable for Split type AC 1.5/2 Ton capacity with and including brazing fixing etc complete all as specified and directed.
WATER COOLERS Checking of Water cooler of any make / capacity in location and position at any site in Technical / Domestic Area Halwara including necessary servicing comprising of cleaning drain water system, cleaning condensor, cleaning condesor fan motor, cleaning storage, water tank cleaning and testing for proper functioning of water cooler complete all as specified and directed.
Removing of defective compressure sealed unit from water cooler storage type 40/80 Ltr per hours for repair, cutting supply and fixing new compressor sealed unit complete of same capacity and make of model AV-100 of Tecumesh or equivalent model of make as approved by GE including instaling with existing system by brazing etc. Flushing of complete system with CO2 gas to dedect any leakage if any including charging of refrigent approved M12/134A or as per recommendation of manufacture to its full capacity including connecting and testing complete all as directd. Note-Cost of minor spares require to make the cooler functional shall deemed to be included in quoted rate.
Taking down the existing unserviceable blower moter motor HP-1/32 from water cooler of cap 40 Litrs/hrs and supply and fixing new blower moter single phase AC 230 volts of same capacity complete all as specified.
Supply and fix in replacement starting relay suitable for water cooler 40/60/120 /150 Ltr/hrs cooling capacity.
Thermostat switch with knob for water cooler, having cooling capacity 40/60/80/120/150 Ltrs/hr as in replacement complete all as specified.
Starting capacitor 40/60 Mfd oil filled 240 volt AC Supply as in replacement complete all as specified.
Drain PVC pipe, 25 mm bore 70 cms in length with two Nos mild steel clamps necessary brass screws as in replacement and complete specified and directed.
All as per item No. 66.00 but size 32 mm bore suitable for 60/80 Ltrs/Hrs water cooler and not more than 1.00 metre.
Drain water tray made out of 24 gauge stainless Steel sheet of size of 30x12x5 cm deep with necessary GI screws and PVC drain water connection arrangement of size not less than 25 mm dia as in replacement complete all as specified.
Water storage tank top lid made out of 22 gauge mild steel sheet of existing shape and size for water cooler cap 40 to 80 Ltrs, plastic sheet of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with synthetic enamel paint approved colour to match the existing colour complete as in replacement all as specified and directed.
Worn out bottom base of water cooler foundation frame made out of 1.6mm thick MS sheet for water cooler, & frame work made out of angle iron25x25x3 mm, 1.6 mtr in length including cutting welding brazing soldering , making holes for sealed unit , condenser with condensor fan motor , including painting black colour ( two coats ) synthetic enamelled paint over a coat of red oxide primer as in replacement etc and finishing all as directed by Engineer-in-Charge.
Water cooler body back sheet made out of 22 gauge mild steel sheet size of approx size 1120x600 mm including painting with two coats of synthetic enamel paint over a coat of primer, screws etc. as in replacement complete all as specified and directed by Engineer-in-Chage
CP push cock,15mm bore made of brass chromium plated self closing horizontal type with CP adaptor and nipple complete as in replacement all as specified.
Checking of leakage in the storage water tank of cooler of cooling cap 40/60/80 Ltr/hour and making good by soldering / brazing to prevent leakage spots incl. cleaning of water tank and testing as complete all as specified. (NOTE : work is to be carried out in existing position as and where machine lyes in defence area)
Starting capacitor 60/80 Mfd oil filled 240 volt AC supply as in replacement complete all as specified
Running capacitor of 15 Mfd oil filled as in replacement complete all as specified
Running capacitor of 10 Mfd oil filled as in replacement complete all as specified
Running capacitor of 2.5 Mfd oil filled as in replacement complete all as specified.
PVC float valve 15 mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball complete with check nut/socket/GI nipple as in replacement complete all as specified and directed by Engineer-in-Charge.
Aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 40 Ltr/hr water cooler as in replacement complete all as specified.
Condenser unit complete suitable for 40/60 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed as in replacement complete all as per direction of Engineer-in-Charge
Copper filter and capillary tube of water cooler cooling capacity 40/80 Ltr/hrs as in replacement complete all as specified.
PVC insulated and PVC sheathed flexible cable , multistranded copper conductor 3 core 2.5 Sq mm cross sectional area superior quality as in replacement complete all as specified.
MCB DB 2 way duly fitted with MCB SPN-20 A, 240 V as in replacement complete all as specified.
Scratching out the existing paint with emery paper and filling up the cavaties/scratch with primer and appling spray painting using synthetic enameld paint (shades as per Required water cooler of capacity 150/120/80/60/40/Ltrs and anticorrosive black paint to compressure and base including Genral servicing complete all as directed
REFRIGERATORS / DEEP FREEZER Removing of defective compressure sealed unit from Refrigeratorsr 165 to 286 Ltrs, cutting and supply and fixing new complete of same capacity of Tecumseh compressor sealed unit complete or equivalent make, instaling with existing system by brazing etc. Flushing of complete system with CO2 gas to detect any leakage if any including charging of refrigent approved M12 or as per recommendation of manufacture to its full capacity including connecting and testing complete all as directd. Note - Cost of minor spares require to make the equivalent functional shall deemed to be included in quoted rate.
Removing of defective compressure sealed unit from Deep Freezer 310 Litrs, cutting and supply and fixing in replacement new compressor sealed unit complete of same capacity and make of model of Tecumesh or equivalent mode of make copeland instaling with existing system by brazing etc. Flushing of complete system with CO2 gas todetect any leakage if any including charging of refrigent approved M12 or as per recommendation of manufacture to its full capacity including connecting and testing complete all as directd . Note-Cost of minor spares require to make the equivalent functional shall deemed to be included in quoted rate.
Cooling chamber for any type and make of refrigerator of capacity 165 to 286 litrs as in replacement complete all as specified .
Thermostat switch with knob for Refrigirater as in replacement complete all as specified.
Starting relay suitable for compressure of Refrigeraters of any capacity as in replacement complete all as specified
Door gasket of best quality suitable for 165/286 litres cap. Refrigerator as per manufacturer's instruction as in replacement and directed by Engr-in-Charge.
Bulb pin/screw type, 230 Volts suitable for 165/286 Ltrs Cap. Refrigerator as in replacement complete all as specified.
Door lock with keys-2 nos. for any capacity of refrigerator as in replacement as per sample approved by GE.
PVC Vegetable /Fruit tray and suitable for 165/286 Ltrs Cap. Refrigeraator as in replacement complete of matching size and pattern.
Supply and fixing bottom stand of refrigerator as in replacement all as directed by Engr-in-Charge.
Evaporator assy with screw, jointing of tubes etc and testing of cap, 165 to 286 Ltrs refrigerator as in replacement complete all specified.
DESERT COOLERS Taking out and refixing after repairs, including rewinding of Desert Cooler fan motor of any make of cap. 1/5 HP with super enameled copper winding wire of appropriate size and testing complete all as specified.
Desert Cooler fan motor cap. 1/5 HP three speed, 1400 RPM single phase with fan blade, bracket supporting stand as in replacement complete all as specified.
Bush for cooler fan motor as per existing sample as in replacement complete all as specified.
Shaft for cooler fan motor as per existing sample as in replacement complete all as specified.
Capacitor 4.00 mfd for cooler fan motor as in replacement complete all as specified.
Bottom tank of Desert Cooler made out of 18 gauge PGI sheet including necessary , painting the new surfaces to match with existing surface outside and inside sourface with approved quality paint including leakage testing complete as in replacement all as specified and directed by Engineer-in-charge.
Front grill ( horizontal and vertical members moveable) of the Desert Cooler made out of Essiting gauge PGI sheet as in replacement complete all as specified.
Side/rear panel made out of Existing gauge PGI Sheet with suitable handles including painting to match with the existing desert cooler as in replacement complete all as specified and directed by Engineer-in-charge. (As per sample kept in GE Office)
Painting to old steel surfaces of Desert cooler capacity up to 6000 cfm with one coat of synthetic enamel spray paint (hammer tone paint) of approved colour on external surface and one coats of anti corrosive black paint inside the Body tank and side grills on internal surfaces including scraping/rubbing with wire brush on old and writing of MES No etc complete all as specified and directed by Engineer-in-Charge. Note : The work shall be carriedout at the site / EM yard as per requirement.
Submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt as in replcement complete all as specified. Make : RADO KR-1900 or equivalent as per approved by GE.
Wood wool pad for Desert Cooler of Sutable size (set of three pads) superior quality including binding properly with GI earth wire with grill as in replacement complete all specified.
PVC water distribution cup of one inlet and 3 outlets with MS nuts and bolts as in replacement complete all as specified.
PVC elbow suitable for Desert Cooler as in replacement complete all as specified.
PVC pipe 15 mm dia heavy duty for Desert Cooler Pump as in replacement complete all as specified.
GI Nipple 15mm dia 6 inch long for Desert Water cooler as in replacement complete all as specified. .
Fan Blade as per Exiting Size of heavy duty mild steel for deser cooler as in replacement complete all as specified.
3 pin plug top cap 15 Amp single phase AC Supply 240 Volts as in replacement complete all as specified.
3 pin plug top cap 5 Amp single phase AC Supply 240 Volts as in replacement complete all as specified.
Supply and charging refrigerant R 22
Supply and charging gas - 32
Supply and charging Nitrogen gas
CHOUDHARY ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .