Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 and Most Reasonable | |
| 2 | L2₹5.9 L+₹53,465.02 (9.91%)Rejected-Finance | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹6.0 L+₹59,741.13 (11.1%)Rejected-Finance | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹6.4 L+₹95,844.52 (17.8%)Rejected-Finance | L4 | Rejected-Finance Being Not L1 | |
| 5 | L5₹6.6 L+₹1.2 L (23.0%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Being Not L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
20 Jun 2024, 6:00 pmClosed
AGE(I) DALHOUSIE PIN-176305
AGE(I) DALHOUSIE PIN-176305
CERTAIN REPAIR REPLACEMENT OF US SECURITY LIGHT STREET LIGHT AND MISC WORKS AT GEMINI TICCA AND BALLON AREA AT DALHOUSIE
2024_MES_656367_1
9041/2024-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE(I) DALHOUSIE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) DALHOUSIE
₹18,000
Yes
AGE(I) DALHOUSIE
2 Sept 2024
29 May 2024
27 Jun 2024
29 May 2024
20 Jun 2024
13 Jun 2024
29 May 2024 - 8 Jun 2024
8 Jun 2024
Amount
Labour only for checking the serviceability of different spares / components / parts of security light fittings (T-5, HPSV, HPMV, Metal Halide,LED LIGHT fittings etc, any wattage/capacity) of any description and in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed by Engineer-in-Charge. NOTES FOR SCH `A’ ITEM NO 1:- (i) Fixing element of the new replaced part(s) is deemed to be included in the rates quoted by the contractor for above item and new parts shall be measured and paid separately as supply only against respect items of Sch ‘A’. (ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site. (iii) Required screws, insulating tapes, internal wiring wire , gaskets and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition.
PVC flat twin core unarmoured Aluminium cable of size 2.5 Sqmm all as specified. Make- Havells/Finolex/polycab
PVC flat twin core unarmoured Aluminium cable of size 6.0 Sqmm all as specified. Make- Havells/Finolex/polycab
PVC flat twin core unarmoured Aluminium cable of size 10 Sqmm all as specified. Make- Havells/Finolex/polycab
Supply and Fix in replacement of Street Light fitting LED 45 W with all assessories,/ electric connectins all as specified. Make Crompton Greaves/ BAJAJ/SURYA
Supply and Fix in replacement of Street Light fitting LED 50 W with all assessories,/ electric connectins all as specified. Make Crompton Greaves/ BAJAJ/SURYA
Supply and Fix in replacement of Street Light fitting LED 72 W with all assessories,/ electric connectins all as specified. Make Crompton Greaves/ BAJAJ/SURYA
Supply and laying in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip of wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sq mm 3.5 Core.Make : Finolex/Universal/PolyCab
Supply and Laying in replacement of 1100 volts grade heavy duty PVC insulated armoured and PVC sheathed AL conductor laid in trenches/ passing through pipes or fixed on poles of size 25sqmm 3.5 core complete all as specified. Make : Finolex/Universal/PolyCab
Supply and Laying in replacement of 1100 volts grade heavy duty PVC insulated armoured and PVC sheathed AL conductor laid in trenches/ passing through pipes or fixed on poles of size 16sqmm 2 core complete all as specified. Make : Finolex/Universal/PolyCab
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying/taking out cables etc.n exc 10 sq m on plan and getting out , all as specified.
. Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer all as specified.
Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete all as specified. Note - for measurement purpose punned thickeness 18 CM shall be considered
Brick protection to underground cable with sub class bricks, well burnt, laid flat along the length of cable, all as specified.
M & L for junction box hot press moulded SMC of inside dimension size 270x225x135mm and outside dimention 320x260x165mm with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having aluminium bus bar of 100 amps capacity for TPN on necessary base plate and porcelain base including necessary flat iron clamps with nuts, bolts & washers all as specified and directed. Make- Sintex Industries Ltd or equivelent make.
Supply and fixing in replacement of Thermal magnetic release MCCB 4 pole 415 volt rapturing capacity 25 KA of size 200 amp complete all as specified .Make legrand Cat No 420218/equivalent in L&T/ Siemens
Supply and fixing M&L in replacement of Thermal magnetic release MCCB 3 pole 415 volt rapturing capacity 16 KA 0f size 160 amp complete all as specified .Make legrand Cat no4202 07/equivalent in L&T/ Siemens
Supply and fixing M&L in replacement of Thermal magnetic release MCCB 3 pole 415 volt rapturing capacity 16 KA 0f size 100 amp complete all as specified .Make legrand Cat no4202 05/equivalent in L&T/ Siemens
Marerial and labour for two coat of silver painting above one coat of red oxide including scratching/ brushing, removing of old rusted paint and rusted areas of steel tubular pole 11 mtr long all as directed.
Marerial and labour for two coat of silver painting above one coat of red oxide including scratching/ brushing, removing of old rusted paint and rusted areas of steel tubular pole 09 mtr long all as directed.
Earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.65 Mtr below normal ground level connected to GI strip 32 x 6 mm size and earthing lead protected with 50 mm bore GI pipe, light grade, filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1 : 3 : 6 type C1. using 20 mm graded crushed stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion. Note : GI strip upto 7.5 m length is included in the unit rate quoted by the contractor and beyond this length shall be measured & paid separately.
Dismantling of old security light bracket including cutting of welding, if required, fixed to steel tubular pole at any height with electric connectin and refixing the security light on the new bracket on the same pole all as directed. Notes : 1. The old unserviceable bracket shall be isued to the contractor under Schedule of Credit. 2. The new bracket shall be measured and paid separately under the respective item.
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done atleast 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
Re-stretching of aluminium conductor any size and length complete including removing kinks and providing new binding wire /Jumper where required all as specfied and directed by Engineer-in-charge.
SEALINE BUILDERS
M/S MALHI CONSTRUCTIONS
dinesh enterprises
M/S SHRI RAM BUILDERS
Eshaan Construction Co.
M/S WALIA ENGINEERS
M/s Shakti Electric Works
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .