| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.0 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹17.3 L+₹3.3 L (23.6%)Rejected-Finance RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹18.8 L+₹4.9 L (34.7%)Rejected-Finance BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | 3 | Rejected-Finance Not Lowest | |
| 4 | 4₹19.3 L+₹5.3 L (37.9%)Rejected-Finance | 4 | Rejected-Finance Not Lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Sept 2022, 6:00 pmClosed
CWE Bathinda
HQ CWE Bathinda
REPAIR/ MAINTENANCE OF DG SETS AND CONNECTED ITEMS INSTALLED AT VARIOUS LOCATION UNDER GE (UTILITY) BATHINDA AT BATHINDA MIL STN
2022_MES_545831_1
CWE BTD 8118/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BATHINDA
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (U) Bathinda
₹50,000
Yes
8 Oct 2022
17 Aug 2022
15 Sept 2022
17 Aug 2022
13 Sept 2022
1 Sept 2022
17 Aug 2022 - 1 Sept 2022
Amount
M & L for 'B' check of DG Sets of capacity 20KVA to 63KVA complete as per following :-(i)Draining out engine/lubricant oil, flushing including filling fresh oil after drain out old oil by skilled tradesman of DG set including replacement of oil pan /chamber gasket. (ii)S& F in replacement lubricant oil filter element. (iii) S&F in replacement fuel filter element. (iv) S & F bypass filter element. (v) checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc.(vii) Checking of belt tension and adjusting as per requirement. (viii) Checking hose and fuel pipe and fix new if required. Note:- Cost of Engine/ lubricating oil, oil Filter element, fuel filter, bypass filter element are included in this item and nothing shall be paid extra on this account.
All as per item No 1 above but DG set capacity 100 KVA to 225 KVA complete all as specified
All as per item No 1 above but DG set capacity 250 KVA to 380 KVA complete all as specified
All as per item No 1 above but DG set capacity 500 KVA complete all as specified
M & L for repairing decarburizing manifolds exhaust system and connected items of exhaust muffler / silencer including necessary nuts, bolts and washers necessary welding etc with necessary masonry works as required complete all as specified and directed. Note :- Any building/ civil work for support of manifolds exhaust system will be included in this item and nothing shall be paid extra on this account.
M&L for calibration of fuel injector pump of DG Set for 20 KVA to 63 KVA capacity and replacement of flowing unserviceable parts of the pump complete all as specified and directed:- Note:- New parts provided as per site requirement shall be measured and paid separately as supply only in this BOQ.
Supply only Element . Make as per existing : Mico
Supply only Delivery valve . Make as per existing : Mico
Supply only Bearing of existing one. Make as per existing : Mico
Supply only Pump seal. Make as per existing : Mico
M&L for calibration of fuel injector pump of DG Set for 100 KVA to 200 KVA capacity and replacement of flowing unserviceable parts of the pump complete all as specified and directed:- Note:- New parts shall be measured and paid separately as supply only in this BOQ.
Supply only Element . Make as per existing : Mico
Supply only Delivery valve . Make as per existing : Mico
Supply only Bearing of existing one. Make as per existing : Mico
Supply only Pump seal. Make as per existing : Mico
M&L for calibration of fuel injector pump of DG Set for 250 KVA to 380 KVA capacity and replacement of flowing unserviceable parts of the pump complete all as specified and directed:- Note:- New parts shall be measured and paid separately as supply only in this BOQ.
Supply only Element . Make as per existing : Mico
Supply only Delivery valve . Make as per existing : Mico
Supply only Bearing of existing one. Make as per existing : Mico
Supply only Pump seal. Make as per existing : Mico
Disconnecting and dismantling of DG set of 43 KVA carefully without damaging any parts and move it to the another site within 5 Km range making all necessary connections like earth connections, electric supply wire connection, battery charging connections etc complete for fully functioning and testing the DG Set complete all as specified and directed.
Taking out the self starter 24 Volt of DG Set capacity 100 KVA to 380 KVA and shifting to workshop for rewinding of armature including replacement of unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified. Note:- Major parts will be measured and paid under relevent item suitable for as per existing make.
Supply and fixing in replacement steel pinion. Make as per existing : Lucas.
Supply and fixing in replacement Clutch assy. Make as per existing : Lucas.
Supply and fixing in replacement Solenoid switch. Make as per existing : Lucas.
Supply and fixing in replacement Carbon brush. Make as per existing : Lucas.
Taking out the self starter (12 Volt) of DG Set capacity 20 KVA to 63 KVA and shifting to workshop for rewinding of armature including replacement of unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified.
Supply and fixing in replacement steel pinion. Make as per existing : Lucas.
Supply and fixing in replacement Clutch assy. Make as per existing : Lucas.
Supply and fixing in replacement Solenoid switch. Make as per existing : Lucas.
Supply and fixing in replacement Carbon brush. Make as per existing : Lucas.
Taking out the charging alternator of DG Set capacity 100 KVA to 380 KVA and shifting to workshop for rewinding of armature including replacement of unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified. Note:- Major parts will be measured and paid under relevent item suitable for as per existing make.
Taking out the charging alternator of DG Set capacity 20 KVA to 63 KVA and shifting to workshop for rewinding of armature including replacement of unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified.
Supply and fixing in replacement of air cleaner filter for DG Set capacity 250 KVA to 380 KVA complete all as specified.
Supply and fixing in replacement of air cleaner filter for DG Set capacity 100 KVA to 225 KVA complete all as specified.
Supply and fixing in replacement of air cleaner filter for DG Set capacity 7.5 KVA to 62.5 KVA complete all as specified.
M&L for cleaning of diesel tank of DG Set of any capacity including replacement of worn-out pipe line and measuring scale and fixing in original position and make it leak proof with necessary clamps complete all as specified and directed.
Supply and fixing in replacement battery Terminals heavy duty Copper.(Positive & Negative) complete set.
Supply and fixing in replacement battery Copper cable Red having length not less than 2.0 mtr and size 50 Sqmm with plug complete.
Supply and fixing in replacement battery Copper cable black having length not less than 2.0 mtr and size 50 Sqmm with plug complete.
Supply & fixing K cool super plus-50-50 PREMIX of 1 Ltrs sealed Packing all as specified.
Supply and fixing in replacement Radiator hose pipe for DG Set complete all as specified.
Supply and fixing in replacement Fuel pipe for DG Set complete all as specified.
Supply and fixing in replacement oil seal set suitable for DG Set of any capacity complete all as specified.
Supply and fixing in replacement fan belt set suitable for DG Set of any capacity of existing size complete all as specified.
Taking out the water pump assembly for capacity 20KVA to 63 KVA and shifting to workshop for repairing and resurfacing including replacement of small & big bearing,impeller, cover plate and water seals complete all as specified and directed Engineer –in-charge.
Taking out the water pump assembly capacity 100KVA to 200 KVA and shifting to workshop for repairing and resurfacing including replacement of small & big bearing, impeller, cover plate and water seals complete all as specified and directed Engineer –in-charge.
Taking out the water pump assembly capacity 250KVA to 380 KVA and shifting to workshop for repairing and resurfacing including replacement of small & big bearing, impeller, cover plate and water seals complete all as specified and directed Engineer –in-charge.
Servicing repair/ maintenance of DG set capacity 100 KVA, removing tappet cover and cylinder heads from DG set, grinding and polishing of cylinder heads, grinding of valve sets, grinding of inlet and exhaust valve after fixing new seats, calibration of injector, refitting cylinder head and tappets covers, changing of oil and replacement of following parts including testing the DG sets on load complete all as specified. Note:- Spare parts will be paid separately under respective items as supply only.
Supply only Bearing as per existing.
Supply only inlet and exhaust valve pair as per existing.
Supply only Valve sheet insert as per existing
Supply only inlet and exhaust valve guide as per existing.
Labour only for alignment of piston assy complete.
Supply only Cylinder liner with joint ring
Supply only Set of joint
Supply only Gasket for head
Supply only Gear oil seal
Supply only Oil seal all .
Supply only Thermostat element
Supply only Hose set
Supply only Lub oil cooler
Supply only Lub oil pressure guage
Supply only Flexible pipe
Supply only Sensor unit complete as per existing make and model.
Supply only Starter ring.
Supply only WP assy.
Supply only head assy
Supply only K oil premium.
Supply only Fuel pipe.
Servicing repair/ maintenance of DG set capacity 320 KVA, removing tappet cover and cylinder heads from DG set, grinding and polishing of cylinder heads, grinding of valve sets, grinding of inlet and exhaust valve after fixing new seats, calibration of injector, refitting cylinder head and tappets covers, changing of oil and replacement of following parts including testing the DG sets on load complete all as specified. Note:- Spare parts shall be measured and paid separately under respective items as supply only.
Supply only Bearing as per existing cat part.
Supply only inlet and exhaust valve pair as per existing cat part.
Supply only Valve sheet insert as per existing cat part.
Supply only inlet and exhaust valve guide as per existing cat part.
Supply only piston assy complete as per existing cat part.
Supply only Cylinder liner with joint ring
Supply only Set of joint
Supply only Gasket for head
Supply only Gear oil seal
Supply only Oil seal all.
Supply only Thermostat element
Supply only Hose set
Supply only Lub oil cooler
Supply only Lub oil pressure guage
Supply only Flexible pipe
Supply only Sensor unit complete as per existing make and model.
Supply only Starter ring.
Supply only WP assy.
Supply only head assy
Supply only K oil premium.
Supply only Fuel pipe.
Material and Labour for earthing complete with galvanized iron of street or earth plate Each electrode of size 60 x 60 x 0 .63 cm thick buried directly in ground. Vertically total depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI earth strip 32 x 6 mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer (including making of test point with GI strip of size 25 x 4 mm) including GI protection pipe 40 mm light grade dia for protection of strip upto test point all as directed GI pipe medium grade 20 mm bore for watering including providing funnel and wire mesh CI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40 mm graded stone aggregates complete including excavation and earth work, all as specified and show in plate No 3 of SSR-2009 Part - I, PCC pit shall be provided at least 50 cm away from the earth pit and not just on earth pit including testing on completion.
M & L for painting of exhaust pipe of DG sets with heat resistant paint of approved quality including preparation of surface of exhaust pipe complete all as specified and directed.
Supply and filling distilled water for lead acid battery all as specified.
Taking out unserviable asbestos rope from the exhaust pipe cleaning the exhaust pipe, supply and wrapping new asbostos rope of suitable size and wrapping with wire mesh and plastering with plaster of pairs/ white cement for smooth finishing including replacement of gasket and tightening of all nut and bolts all as specified and directed.
Disconnecting the battery 12 Volts 180 AH from the DG set shifting to workshop for further dismantling for repair/replacement of cells, plates, reconditioning, filling of electrolyte of required specific gravity and charging the battery, after repair shifting the batteries from workshop to E/M installation fixing to the DG set and testing complete all as directed by Engineer-in-charge.
Disconnecting the battery 12 Volts 120 AH from the DG set shifting to workshop for further dismantling for repair/replacement of cells, plates, reconditioning, filling of electrolyte of required specific gravity and charging the battery, after repair shifting the batteries from workshop to E/M installation fixing to the DG set and testing complete all as directed by Engineer-in-charge.
Disconnecting the battery 12 Volts 75 AH from the DG set shifting to workshop for further dismantling for repair/replacement of cells, plates, reconditioning, filling of electrolyte of required specific gravity and charging the battery, after repair shifting the batteries from workshop to E/M installation fixing to the DG set and testing complete all as directed by Engineer-in-charge.
S&F Battery charger 24 volt 10 Amps based on SMPS technology provides constant current with reverse protection and indicator. The charger shall support all brand batteries and compatible with 12 v 40 AH to 12 V 250 AH lead acid and alkaline batteries complete all as specified and directed by Engineer-in-Charge.
S& F 12 volts 180 AH battery with float guide to indicate Electrolyte level,spill proof, moulded handles, top vented lid with anti splash guards fitted with coin flush vent plugs, spark arrestor fitted in float to restrict fumes and acid during operation complete all as directed by Engineer-in-charge.
S&F in replacement display unit of 63 KVA DG Sets. Display Board features of microprocessor based KG 934 controller :- (i) Engine parameter display:- Engine oil pressure, Engine temp, lab oil temp, canopy temp, Battery voltage, Engine RPM, Engine Running Hrs, Fuel level indicator, %of tank capacity. (ii)Engine protection:-Low oil pressure, High/low battery voltage, High engine temp, low radiator coolant level, Engine over speed, Engine under speed, low fuel level in diesel tank, Battery charging indicator. (iii)Electrical parameter display:-voltage, line to line, line to neutral, DG load current, Gen load voltage, frequency, load power factor, KW, KVA (iv) Electrical protection:-Over voltage, under voltage, over KVA, over Current.
S&F in replacement display unit of 100 KVA DG Sets. Display Board features of microprocessor based KG 934 controller :- (i) Engine parameter display:- Engine oil pressure, Engine temp, lab oil temp, canopy temp, Battery voltage, Engine RPM, Engine Running Hrs, Fuel level indicator, %of tank capacity. (ii)Engine protection:-Low oil pressure, High/low battery voltage, High engine temp, low radiator coolant level, Engine over speed, Engine under speed, low fuel level in diesel tank, Battery charging indicator. (iii)Electrical parameter display:-voltage, line to line, line to neutral, DG load current, Gen load voltage, frequency, load power factor, KW, KVA (iv) Electrical protection:-Over voltage, under voltage, over KVA, over Current. Note:- Cost of repair/ replacement of concerned plug/ wires is deemed to be included in this job. Nothing extra shall be paid on this account.
S&F in replacement display unit of 200 KVA DG Sets. Display Board features of microprocessor based KG 934 controller :- (i) Engine parameter display:- Engine oil pressure, Engine temp, lab oil temp, canopy temp, Battery voltage, Engine RPM, Engine Running Hrs, Fuel level indicator, %of tank capacity. (ii)Engine protection:-Low oil pressure, High/low battery voltage, High engine temp, low radiator coolant level, Engine over speed, Engine under speed, low fuel level in diesel tank, Battery charging indicator. (iii)Electrical parameter display:-voltage, line to line, line to neutral, DG load current, Gen load voltage, frequency, load power factor, KW, KVA (iv) Electrical protection:-Over voltage, under voltage, over KVA, over Current. Note:- Cost of repair/ replacement of concerned plug/ wires is deemed to be included in this job. Nothing extra shall be paid on this account.
S&F in replacement display unit of 320 KVA DG Sets. Display Board features of microprocessor based KG 934 controller :- (i) Engine parameter display:- Engine oil pressure, Engine temp, lab oil temp, canopy temp, Battery voltage, Engine RPM, Engine Running Hrs, Fuel level indicator, %of tank capacity. (ii)Engine protection:-Low oil pressure, High/low battery voltage, High engine temp, low radiator coolant level, Engine over speed, Engine under speed, low fuel level in diesel tank, Battery charging indicator. (iii)Electrical parameter display:-voltage, line to line, line to neutral, DG load current, Gen load voltage, frequency, load power factor, KW, KVA (iv) Electrical protection:-Over voltage, under voltage, over KVA, over Current. Note:- Cost of repair/ replacement of concerned plug/ wires is deemed to be included in this job. Nothing extra shall be paid on this account.
S&F in replacement Governor Card for 320 KVA DG set complete all as specified.
S&F in replacement Governor Card for 200 KVA DG set complete all as specified.
S&F in replacement Governor Card for 125 KVA DG set complete all as specified.
S&F in replacement Governor Card for 62.5 KVA DG set complete all as specified.
S&F in replacement Governor Card for 25 KVA DG set complete all as specified.
S&F in replacement magnetic pick up sensor for 320 KVA DG Set complete all as specified.
S&F in replacement magnetic pick up sensor for 200 KVA DG Set complete all as specified.
S&F in replacement magnetic pick up sensor for 125 KVA DG Set complete all as specified.
S&F in replacement magnetic pick up sensor for 62.5 KVA DG Set complete all as specified.
S&F in replacement magnetic pick up sensor for 25 KVA DG Set complete all as specified.
M & L for cleaning of DG sets including removing of oil grease and spot washing carefully with soda water preparation of old painted surface and painting to the DG sets of capacity 20 to 62.5 KVA with two coats of spray painting of approved make and colour of first grade paint and marking SM/MES No as per existing all as specified and directed.
M & L for cleaning of DG sets including removing of oil grease and spot washing carefully with soda water preparation of old painted surface and painting to the DG sets of capacity 100 to 200 KVA with two coats of spray painting of approved make and colour of first grade paint and marking SM/MES No as per existing all as specified and directed.
M & L for cleaning of DG sets including removing of oil grease and spot washing carefully with soda water preparation of old painted surface and painting to the DG sets of capacity 250 to 380 KVA with two coats of spray painting of approved make and colour of first grade paint and marking SM/MES No as per existing all as specified and directed.
S & F in repair on load change over switch 800 Amps, 415 volts, four pole modular construction confirm to IS/IEC 60947-3 with door interlock and padlock facility in steel sheet enclosure of size 3.15 mm thickness including mounting arrgments for fixing on wall/ wooden/ floor mechanically operated including disconnecting electric connection and dismantling existing change over switch complete all as specified and directed.
All as per item No. 58 here-in-before but 630 Amps
All as per item No. 58 here-in-before but 400 Amps
All as per item No. 58 here-in-before but 320 Amps
All as per item No. 58 here-in-before but 250 Amps
All as per item No. 58 here-in-before but 200 Amps
All as per item No. 58 here-in-before but 160 Amps
All as per item No. 58 here-in-before but 125 Amps
All as per item No. 58 here-in-before but 100 Amps
All as per item No. 58 here-in-before but 63 Amps
M & L for servicing of main panel 24 volts DC and 440 Volt AC supply operated system locating by fault and replacement of unserviceable parts and components complete all as specified and directed as per the following:-(a) Repair of worn out / faulty internal wiring DC/AC with adequate and suitable size copper conductor wire, connected with proper copper lugs and terminals through protection pipe/ casing. (b) Replacement of worn out faulty internal wiring of controls and timers indicating / measuring instruments through various control fuses and relays with suitable and adequate size of copper conductor wire connected with suitable copper lugs and terminals. (c) Replacement of worn out small control fuses, indicating lamps, voltmeter, Ammeter, power meter, CT complete and various types of copper thimble, lugs terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order. (d) Material and labour for painting of Panel metallic body surface with one coat of superior quality synthetic enamel paint of approved colour and first quality including replacement of worn out rubber bedding. (e) Testing of system on load. Note:- Supply only spare parts for replacement where required shall be measured and paid separately) of various capacity of DG sets installed at various locations of capacity 63 KVA-02 Nos.
Supply only Digital Volt Meter (0-500 Volts)
Supply only Digital Amp Meter (0-200 Amps)
Supply only Digital power meter
Supply only Set of 3 CTs complete.
S&F in replacement radiator fan assembly along with hub suitable for DG set of any capacity complete all as specified.
Opening the coupling of DG Set of capacity 250 to 380 KVA, the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including M & L for replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully functional complete all as specified.
Opening the coupling of DG Set of capacity 20 to 63 KVA the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including M & L for replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully functional complete all as specified.
Opening the coupling of DG Set of capacity 100 to 250 KVA the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including M & L for replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully functional complete all as specified.
Servicing of radiator assembly of DG Set 100 to 250 KVA and replacement of minor parts to make it operational including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re-fixing after testing complete and making it leak proof including replacement of worned out tubular hoses alongwith clip etc complete all as specified and directed.
Servicing of radiator assembly DG Sets 20 KVA to 63 KVA and replacement of minor parts to make it operational including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re-fixing after testing and making it leak proof complete all as specified.
Servicing of radiator assembly DG Sets 260 KVA to 380 KVA and replacement of minor parts to make it operational including descaling of tubes with solution and chemicals and compressed air blast including transportation to workshop and back and re-fixing after testing and making it leak proof complete all as specified.
S & F in repair AVR system high performance completely sealed rugged and compact design with over voltage protection and low speed protection function and other surge protection complete suitable for DG set of capacity 25 KVA
S & F in repair AVR system high performance completely sealed rugged and compact design with over voltage protection and low speed protection function and other surge protection complete suitable for DG set of capacity 63 KVA
S & F in repair AVR system high performance completely sealed rugged and compact design with over voltage protection and low speed protection function and other surge protection complete suitable for DG set of capacity 100 KVA
S & F in repair AVR system high performance completely sealed rugged and compact design with over voltage protection and low speed protection function and other surge protection complete suitable for DG set of capacity 125 KVA
S & F in repair AVR system high performance completely sealed rugged and compact design with over voltage protection and low speed protection function and other surge protection complete suitable for DG set of capacity 200 KVA
S & F in repair AVR system high performance completely sealed rugged and compact design with over voltage protection and low speed protection function and other surge protection complete suitable for DG set of capacity 320 KVA
S & F in repair AVR system high performance completely sealed rugged and compact design with over voltage protection and low speed protection function and other surge protection complete suitable for DG set of capacity 40 KVA
S & F in repair MCCB 4 Pole with electronic release ( microprocessor based) of capacity 630 Amps Ics=50%Icu with line load reversibility and double break roto active mechanism complete all as specified and directed by Engineer-in-Charge.
S & F in repair MCCB 4 Pole with electronic release ( microprocessor based) of capacity 400 Amps Ics=100%Icu with line load reversibility and double break roto active mechanism complete all as specified and directed by Engineer-in-Charge.
S & F in repair MCCB 4 Pole with electronic release ( microprocessor based) of capacity 250 Amps Ics=100%Icu with line load reversibility and double break roto active mechanism complete all as specified and directed by Engineer-in-Charge.
Taking out the turbo charger kit for 20 KVA to 62.5KVA DG Set and shifting to workshop for repair including opening and cleaning of compressor housing, exhaust manifold, inlet manifold, turbine housing with necessary chemicals and replacement of turbine wheels, common shaft, compressor wheel, pressure sensing hose, waste gate capsule , waste gate flap valve etc complete and reinstalling the same all as specified and directed. Note:- Cost of spare parts to be replaced if required is included in the quoted rate of this item. Nothing extra shall be paid on this account.
Taking out the turbo charger kit for 100 KVA to 200KVA DG Set and shifting to workshop for repair including opening and cleaning of compressor housing, exhaust manifold, inlet manifold, turbine housing with necessary chemicals and replacement of turbine wheels, common shaft, compressor wheel, pressure sensing hose, waste gate capsule , waste gate flap valve etc complete and reinstalling the same all as specified and directed. Note:- Cost of spare parts to be replaced if required is included in the quoted rate of this item. Nothing extra shall be paid on this account.
Taking out the turbo charger kit for 200 KVA to 380KVA DG Set and shifting to workshop for repair including opening and cleaning of compressor housing, exhaust manifold, inlet manifold, turbine housing with necessary chemicals and replacement of turbine wheels, common shaft, compressor wheel, pressure sensing hose, waste gate capsule , waste gate flap valve etc complete and reinstalling the same all as specified and directed. Note:- Cost of spare parts to be replaced if required is included in the quoted rate of this item. Nothing extra shall be paid on this account.
Supply and laying in replacement XLPE insulated LT cable of cross sectional area 35 Sqmm 3.5 core, 1100 Volt grade, heavy duty with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel strip or wire and over all PVC sheathed conforming to IS-7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed. Note:- Earth work will be measured and paid separately as per site requirement in this BOQ.
All as per ser item No. 89 here-in-before but size of cable 50 Sqmm 3.5 core complete.
All as per ser item No. 89 here-in-before but size of cable 95 Sqmm 3.5 core complete.
All as per ser item No. 89 here-in-before but size of cable 120 Sqmm 3.5 core complete.
All as per ser item No. 89 here-in-before but size of cable 185 Sqmm 3.5 core complete.
All as per ser item No. 89 here-in-before but size of cable 240 Sqmm 3.5 core complete.
All as per ser item No. 89 here-in-before but size of cable 300 Sqmm 3.5 core complete.
Excavation in trenches in soft / loose soil not exc 1.5 mtr wide and not exc 1.5 mtr deep for pipes / foundation etc for laying cable, shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 mtr depth and getting out in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge.
Returning filling in, including spreading , leveling, watering and well ramming in layers each not exceeding 25cm thick in soft / loose soil complete all as specified and as directed.
Removal of surplus excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
M & L for local sand cushioning,230 mm thickness with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick before laying of cable and 150mm thick after laying of cable and punned down to 180mm after laying complete. Note:- Punned thickness shall be considered for payment purpose.
Supplying and laying PCC cable cover 250 x 150 x 40 mm , ISI marked, class LV Type -1. Make - Topaz/ Mahtab
Dismantling the alternator of DG set, AC 3 Phase, capacity of 20 KVA to 40 KVA, 440 Volt, 1440 RPM, 50 Cycle of any make and type from the DG set and after disconnecting electric cable connection and earthing etc and transportation to civil workshop and back for minor repair and rewinding the alternator stator after cleaning with super enameled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, proving all high grade material and class 'B' varnish for insulation, reassembling the complete alternator and re-fixing at site with electric cable connection, earthing and testing of DG set on full load at site after coupling with DG set up to entire satisfaction of Engineer-in-charge.
All as per ser item No. 101 here-in-before but capacity of 62.5 to 100 KVA complete.
All as per ser item No. 101 here-in-before but capacity of 125 to 250 KVA complete.
All as per ser item No. 101 here-in-before but capacity of 320 to 380 KVA complete.
S & F in replacement battery copper cable black having length not less than 0.5 metre and szie 50 Sqmm with both sides plug complete.
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ
TARA ENTERPRISES
RS ENTERPRISES
MODERN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .