Executive Engineer (E)
BSNL, Electrical Division, ALTTC, Ghaziabad
Repairing of Electrical Installation, AC units and AFD system in T.E. Bldg at Fatehpur Sikari, Patholi, T.E Sanjay Place and IQ at MW Bldg Tora, OA Agra.
2025_BSNL_863384_1
27/EEE/BSNL/ED/GZB/2025-26
Open Tender
Miscellaneous Works
Item Rate
60 days
Agra
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
Account Officer Cash, B.S.N.L, Ghaziabad
₹2,658
2 Jul 2025
5 Jun 2025
17 Jun 2025
5 Jun 2025
16 Jun 2025
5 Jun 2025
( Electrical work at T.E Patholi) SITC of 20 Watt 1200 mm LED tubelight fitting complete with all accessories etc. as required. (M/s Bajaj/ Surya,/ Philips or Similar superior make)-
Supplying & Fixing of follwing piano type switch & sockets in place of faulty components in existing Switch board , Power points i/c connections etc as required. (a) 5/6 Amp single way Switch
b) 3Pin 5/6 Amp Socket outlet
c) 15/16 Amp Switch
d) 6pin 15/16 Amp Socket outlet
e) 3pin 5Amp Ceiling Rose
f) Brass Batten Holder
g) 12 watt LED lamp
h) 200mmx250mmx60 deep MS box i/c phenolic laminated sheet cover etc
i) Phenolic laminated sheet cover in front suitable for 180mmx100mm x60 mm deep MS box etc
j) 200mmx250mmx60 deep PVC box i/c phenolic laminated sheet cover etc
Supplying & Fixing of 100 Amp wall mounted Alumn Busbar box for three phase supply in sheet steel encosure i/c fixing , connection etc as reqd
Dismantalling of Old faulty TPN switch , Bus bar box , faulty changeover switch , DBs, cablings etc & kept the same in safe custody of site incharge etc as required
Rectification of electrical Fault in wiring i/c tracing the fault in wiring , switch boards , Distribution board , fans fitting etc as required
Providing & Fixing of power supply cable 4 x 16 Sqmm PVC insulated PVC sheathed Alumn conductor armored cable of 1.1 KV grade i/c supply of cable , laying , etc complete as required ( ISI Make )
Supplying and making end termination with brass compression gland and aluminium lugs for following size of existing PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required a) 4x16 sq. mm
b) 4x16 sq. mm without gland
Providing & Fixing of Electric Geyser having storage capacity of 15 Ltrs i/c Inlet pipe , outlet pipe , testing & commissioning etc as required at M/W Bldg Tora , Agra .
Supplying of Energy Efficient 30 Watt LED Street Lights fitting, output lumens not less than - 2625 lm and IP-65 Protection fitting i/c fixing on existing wall bracket and connection with 1.5 sq.mm. FRLS PVC insu. cu. condr/ single core cable & earthing etc. as reqd. (conn. for copper cable Approx. 2 mtrs.)complete etc. as required. (M/s Havells 30W Endura Sundown / Syska make ).
Providing ready made wall bracket for street light fitting for suitable size i/c fixing clamps, nut and bolts etc. as required.
Supplying and Laying of 2x1.5 sq. mm. copper conductor armoured cable PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade on surface / recess / ground etc as required
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
(Electrical work at T.E Fatehpur Sikari, Agra) SITC of 20 Watt 1200 mm LED tubelight fitting complete with all accessories etc. as required. (M/s Bajaj/ Surya,/ Philips or Similar superior make)-
Supplying & Fixing of follwing piano type switch & sockets in place of faulty components in existing Switch board , Power points i/c connections etc as required. (a) 5/6 Amp single way Switch
b) 3Pin 5/6 Amp Socket outlet
c) 15/16 Amp Switch
d) 6pin 15/16 Amp Socket outlet
e) 3pin 5Amp Ceiling Rose
f) 4way Sheet steel Enclosure
g) 63 Amp 4pole MCB (M/s MDS Legrand or SS make)
h) Brass Batten Holder
i) 12 watt LED lamp
j) Electronic fan regulator ISI Marked
k) 25 mm PVC Casing & Capping
Rewinding & overhauling of following eletric fans , replacement of bushes , bearing , shaft i/c capacitor etc complete as required. (Note :- Dismantalled copper wire shall be property of contractor , quote the rates accordingly ) a) 1200/1400 mm ceiling fan single phase, 240 volt
Supplying & Fixing of 125 Amp 415 Volt TPN Switch disconnector fuse Unit ( M/s L&T Make : FN-125 or SS make) with sheet steel enclosure , HRC fuses and all accessories i/c connection etc complete as required
Dismantalling of Old faulty TPN switch , Bus bar box , faulty changeover switch , cablings etc & kept the same in safe custody of site incharge etc as required
Proding & fixing of 63 Amp on load changeover swtich in sheet steel enclosure in place of defective off load changeover switch i/c dismantalling , connections etc as required ( M/s HPL Socomec make or SS make )
Rectification of electrical Fault in wiring i/c tracing the fault in wiring, switch boards, Distribution board, fans fitting etc as required
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. a) Upto 35 Sqmm (32 mm)
Providing & Fixing of power supply cable 4 x 16 Sqmm PVC insulated PVC sheathed Alumn conductor armored cable of 1.1 KV grade i/c supply of cable , laying , etc complete as required ( ISI Make )
Supplying and making end termination with brass compression gland and aluminium lugs for following size of existing PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required a) 3½ X 35 sq. mm (32 mm)
b) 3½ x 35 sq. mm (32 mm) without gland
Repairing of 1.5TR Split AC unit i/c replacing of following faulty component ,leak testing , Gas charging , serciving , connection etc as reqd (a) General Servicing of 1.5 TR SAC units at site of different make and model i/c removing from existing position if reqd, dismantling of faulty parts, cleaning the air filter, cleaning the condenser and evaporator coil with help of water pressure spray gun , lubrication of moving parts, complete checking, testing and minor faults rectification i/c replacement of knobs/ wiring kit (if required), setting of thermostat, preparing report including tightness of all electrical connections from SP MCB in DB to DP MCB/Plug & socket to stablizer to AC unit etc as reqd.
b) Charging of Refrigerant gas R-22 /R-32/410 up to specified pressure(as per manufacturer's recommendation) in 1.5 TR Split AC units and pressure testing by nitrogen, vaccumisation for 2 hours, purging with gas and testing commissioning of the AC unit etc. as reqd. Note: One job consists of charging of Gas in one compressor i.e. One complete air conditioning circuit only.
c) 40/50 MFD Running Capacitor aluminum case
d) Repairing / replacenment of Indoor & outdoor PCB for LG make non- Invertor type Split AC Unit etc
Providing Painting with red colour on fire pipes in entire bldg , Fire panel , 02 Nos Fire extingusher ( Co-2 type) etc as required
Repairing of existing main control panel i/c cleaning and replacement of faulty components , connections, testing etc as reqd (a) Repairing of Control card i/c replacement of diode , IC , resistence etc
b) Repairing of Power supply card i/c replacement of diode , capacitor , resistence etc
c) Repairing of Zone card i/c replacement of IC , LED etc
Repairing of electric charging circket i/c replacement rectifier plate , transformer etc
Repairing of fire hooters i/c replacement of speaker & hooter card etc
S/F of 26 AH ,12 Volt maintenance free battery ( Exide make -EP26 AHOR SS make)
M/S MOHIT ENGINEERS (BID ID -3231742)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .