Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST AND REASONABLE BID | |
| 2 | L2₹14.0 L+₹1.4 L (11.1%)Rejected-Finance WARD NO 13 NEW SURATGARH | SURATGARH | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹17.3 L+₹4.7 L (37.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹17.6 L+₹5.0 L (39.9%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹18.0 L+₹5.4 L (42.5%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
5 Sept 2023, 6:00 pmClosed
Lt Col Priyesh Srivastava
GE (AF) SURATGARH
REPAIR / REPLACEMENT OF MCB, DBs, GEYSERS ALONGWITH ALLIED E/M WORKS AT AF STN SURATGARH
2023_MES_612800_1
8103/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹40,000
Yes
20 Sept 2023
8 Aug 2023
7 Sept 2023
8 Aug 2023
5 Sept 2023
22 Aug 2023
Amount
BOQ (REPAIR / REPLACEMENT OF MCB, DBs, GEYSERS ALONGWITH ALLIED E/M WORKS AT AF STN SURATGARH)
Taking down DB/main switch of any size and making good disturbed surface of wall/floor, complete all as specified and directed by Engineer-in-Charge. Note - Temporary power supply shall be provided by contractor.
Taking down unserviceable submain wiring aluminium and making good the disturbed surfaces of walls/ floor etc matching with the existing surface, complete all as specified and directed by Engineer-in-Charge.
S&F for Sub main wiring (concealed ) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 25 mm dia non-metallic PVC conduit fixed in wall including 2.5 sq mm copper earth continuity wire, accessories and connecting to earth dolly, complete all as specified and directed by Engineer-in-Charge. Note :- 2 runs of 4 Sqmm, 1 runs of PVC conduit & 1 runs of 2.5 Sqmm cable shall be measured as single unit length.
M&L for Sub-main wiring in (existing concealed PVC conduit) with two single core 4 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonry including 2.5 sq mm copper earth continuity wire, accessories and connecting to earth dolly , complete all as specified and directed by Engineer-in-Charge. Note :- 2 runs of 4 Sqmm, 1 runs of 2.5 Sqmm cable shall be measured as single unit length.
M&L for Sub-main wiring in (existing concealed PVC conduit) with two single core 6 sq mm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly , complete all as specified and directed by Engineer-in-Charge. Note :- 2 runs of 6 Sqmm & 1 runs of 4 Sqmm cable shall be measured as single unit length. Note for item No.3 to 5 :- The disturbed surfaces of wall for concealing the wiring shall be make good by applying cement plaster, putty and colour wash etc matching with the existing surfaces.
S&F Sheet metal enclosure with socket plug top single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amps , 240 Volts, complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal Vertical TPN double door DB 4 Way, 415 Volt, TPN with 200 Amps rated bus bar complete with MCCB TPN 100 Amps, 16 kA, DPX 160 series as incoming and MCB's SP 40 Amps, 10 kA - 06 Nos as out Going and complete all as specefied and directed.
S&F Sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 12 way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal enclosures for SPN DB's with double glazed door for incorporating MCBs,IP-43 , 8 way with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and directed by Engineer-in-Charge.
S&F Sheet metal enclosures for DB's for incorporating MCBs, TPN, 4 way, IP-43 double glazed door with 200 amps rated busbar, 240 volts, as per IS-8623, complete all as specified and directed by Engineer-in-Charge.
S&F MCB TPN four poles, 63 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F MCB TPN four poles, 100 Amps, breaking capacity 10 KA 'C' curve confirming to IS-8828, 415 volts, 50 HZ including making necessary incoming and outgoing electrical connection with suitable size of copper lugs etc fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 63 amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F MCB SP, 6 to 32 Amps, C series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F for single phase temperproof digital meter equipped with 6 digit ultra bright LED counter, direct operation upto 5-30 Amp (without CT), operating on 220 volt single phase, direct read without multiplication factor, latest microcountroller based technology, Mains LED to indicate presence of auxillary supply, error indication for faulty / reverse connections etc reassembling to make meter serviceable, complete all as directed by Engineer-in-Charge. Make :- HPL/L&T/siemens/Benlo.
M&L Earthing complete with G I earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 4 dia G I wire by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. including replacement of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
Taking down carefully geyser of any capacity of any make any type after removing electric and water connections from existing system for carrying out repairs and re-fixing the same after carrying out necessary repairs to original place complete all as directed by Engineer-in-charge. Note:- Repairs will be measured and paid seprately in respective items of BOQ.
M&L for painting of geyser of any make/shape/capacity with two coats of white synthetic super enameled paint after preparation of surface including marking of MES No by black enameled paint, complete all as specified and directed by Engineer-in-Charge.
S&F Hot & Cold connection pipe, 15 mm dia, 45cm long with chromium plated adopter and washer at both ends including taking out old unserviceable PVC / CP connection, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of heating element spiral / circular type of capacity 2 kW, ISI marked including rubber washer of geyser 50 Litre capacity geyser, complete all as specified and directed by Engineer-in-Charge . Make : ISI Marked as approved by Engineer-in-charge. Note:- Heating element shall be providing as per existing geyser.
S&F in replacement of heating element spiral / circular type of capacity 1.5 kW, ISI marked including rubber washer of geyser 25 Litre capacity geyser, complete all as specified and directed by Engineer-in-Charge . Make : ISI Marked as approved by Engineer-in-charge. Note:- Heating element shall be providing as per existing geyser.
S&F in replacement of thermostat swtich, ISI marked suitable for 25/50 litre capacity geyser ,complete all as specified and directed by Engineer-in-Charge.
S&F bib taps fancy type chromium plated, 15 mm cast copper alloy with crutch handle or butter fly handle screwed down , screwed for iron pipe and fixed as in repair, complete all as specified and directed by the Engineer in Charge.
S&F stop valve 15 mm dia cast copper alloy fancy type chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair , complete all as specified and directed by Engineer-in-Charge.
Cutting existing 15/20 mm dia steel tubing for alteration and addition (each cut measured ) including screwing existing steel tubing for alteration and addition or lengthening screw on pipe to form connector , complete all as specified and directed by Engineer-in-Charge.
S&F PVC insulated copper (flexible) conductor of size 2.5 Sqmm 3 core and connected to geyser including taking down old unserviceable cable of any size complete all as directed by Engineer-in-charge.
Replacement of apparatus plate/assembly plate of geyser with nut ,bolts,clamps,washer ,etc of geyser suitable for record /ditz make or any other make and any capacity including PRV & NRV system complete all as specified and directed.
S&F apparatus plate bottom cover in two halves made out of GI sheet dully painted with two coats of synthetic enemal paint white in colour fixed with nut, bolts, clamps, washer etc of geyser of any capacity, fixed in repair, complete all as directed by Engineer-in-charge.
Welding with new brass studs for holding of heating element with replacement of suitable element holding clamps - 3 Nos, complete all as directed by Engineer-in-charge.
M&L for indicator lamp round/flat type of size & shape as per existing suitable for 25/50 litre capacity geyser working on 230 Volts AC Supply including necessary connections etc, fixed as in repair, complete all as directed by Engineer-in-charge.
Detecting the leakage from geyser of any capacity and arresting the same by brazing / soldering complete all as directed by Engineer-in-charge.
S&F Anchor fastening of suitable size for fixing of geyser of any capacity, complete all as specified and directed.
S&F vent pipe using medium grade GI tubing 20 mm dia fixed to wall /ceiling upto level not less than 15 cm from OH tank top level including necessary fittings fixtures ,clamps ,except tee etc , complete all as specified and directed by Engineer-in-Charge.
S&F plug top 20 / 32 Amp suitable for any type of geyser connection, complete all as specified and directed by Engineer-in-Charge.
S&F NRV of 15mm dia, complete all as specified and directed by Engineer-in-Charge.
S&F steel water tubes, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors, fixed as in repair, complete all as specified and directed by the Engineer in Charge.
S&F water heater outer shell (cover) of capacity 25 liter made out of MS sheet as per existing make, including taking out old unserviceable outer cover, complete all as specified and directed by Engineer-in-Charge.
S&F water heater outer shell (cover) of capacity 50 liter made out of MS sheet as per existing make, including taking out old unserviceable outer cover, complete all as directed by Engineer-in-Charge.
S&F water heater inner tank of capacity 25 ltr made out of copper suitable to with stand water pressure upto 8 bar with fittings and fixed including taking out old unserviceable inner tank, complete all as specified and directed by Engineer-in-Charge.
S&F water heater inner tank of capacity 50 ltr made out of copper suitable to with stand water pressure upto 8 bar with fittings and fixed including taking out old unserviceable inner tank, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing of electric water heater, vertical storage type steel inner tank and heating element upto 2 KW AC Single phase 230 volt , 50 Hz of storage capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, etc including provn of flexible 3 core copper wire of size 4 sqmm from power point to water heater including required hold fast 10 CM long with washers complete all as specified and directed by Engr-in-charge etc.
Contract Amount shall be derived after deducting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
AGGARSAIN BUILDERS
SHARMA CONSTRUCATION COMPANY
MISHRA CONSTRUCTION COMPANY
M/s Rohit Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .