Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.6 LAccepted-AOC RATNA RAJ BUILDING 1ST FLOOR 262 BIDHAN ROAD OPP TERA HOTEL WEST BENGAL | MEDINIPUR WEST | WEST BENGAL | 712122 | ₹44.6 L Quoted ₹45.8 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹47.7 LRejected-Finance | ₹47.7 L | L2 | Rejected-Finance Not Lowest Bidder |
| 3 | L3₹48.0 LRejected-Finance MAJUMDER COLONY BURDWAN ROAD SILIGURI DIST DARJEELING WB PIN 734 014 | DARJEELING | WEST BENGAL | 734014 | ₹48.0 L | L3 | Rejected-Finance Not Lowest Bidder |
| 4 | L4₹48.3 LRejected-Finance | ₹48.3 L | L4 | Rejected-Finance Not Lowest Bidder |
| 5 | L5₹48.7 LRejected-Finance | ₹48.7 L | L5 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | KD SAHA and CO.INDIA L2 | M/S Vaishno Constructions L8 | M/S Joy Construction L5 | ENGINEERING AND CONSTRUCTION CO. L1 | SRI A B SEN L4 | MESSERS BEE GEE CONSTRUCTION L6 | Prahalad Rai L7 | M/S P. RAI CHOUDHURY AND CO. L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for providing precast cement concrete PCC (1:3:6) type C0 (using 12.5mm graded stone aggregate) louvres and jallies, 25mm thick (measured solid), including all mould- ings but excluding frame Set in cement mortar 1:4 complete all as specified and directed. | 40 | Sqm | 405 ₹16,200 | 400 ₹16,000 | 405 ₹16,200 | 400 ₹16,000 | 405 ₹16,200 | 404 ₹16,160 | 404 ₹16,160 | 401 ₹16,040 |
| 2.00 | M&L for cement concrete 1:3:6 type C2,using 40mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and directed. | 28 | Cum | 6,000 ₹1.7 L | 6,000 ₹1.7 L | 6,100 ₹1.7 L | 5,900 ₹1.7 L | 6,200 ₹1.7 L | 6,110 ₹1.7 L | 6,110 ₹1.7 L | 6,100 ₹1.7 L |
| 3.00 | M&L for Providing, cement concrete 1:2:4 type-B1 in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed. | 1 | Cum | 7,000 ₹7,000 | 7,000 ₹7,000 | 7,100 ₹7,100 | 6,800 ₹6,800 | 7,200 ₹7,200 | 7,210 ₹7,210 | 7,210 ₹7,210 | 7,200 ₹7,200 |
| 4.00 | Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed. (Pidiproof of Dr.fixit or equivalent) | 2 | Ltr | 155 ₹310 | 160 ₹320 | 155 ₹310 | 150 ₹300 | 165 ₹330 | 163 ₹326 | 163 ₹326 | 160 ₹320 |
| 5.00 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. | 5 | Cum | 7,300 ₹36,500 | 7,000 ₹35,000 | 7,100 ₹35,500 | 7,200 ₹36,000 | 7,200 ₹36,000 | 7,266 ₹36,330 | 7,266 ₹36,330 | 7,250 ₹36,250 |
| 6.00 | M&L for brickwork with old size fly ash bricks, straight or curved on plan to any radius as in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. | 5 | Sqm | 1,250 ₹6,250 | 1,250 ₹6,250 | 1,220 ₹6,100 | 1,240 ₹6,200 | 1,270 ₹6,350 | 1,268 ₹6,340 | 1,268 ₹6,340 | 1,260 ₹6,300 |
| 7.00 | M&L for MS work in posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 and similar work complete all as specified and directed. | 1,260 | Kg | 146 ₹1.8 L | 160 ₹2.0 L | 165 ₹2.1 L | 148 ₹1.9 L | 164 ₹2.1 L | 165 ₹2.1 L | 165 ₹2.1 L | 155 ₹2.0 L |
| 8.00 | M&L for MS framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. | 120 | Kg | 159 ₹19,080 | 160 ₹19,200 | 165 ₹19,800 | 160 ₹19,200 | 165 ₹19,800 | 169 ₹20,280 | 169 ₹20,280 | 165 ₹19,800 |
| 9.00 | S&F Mild steel screw bolts Diameter of neck in 5 to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and n exc 15cm long complete all as specified and directed. | 4 | Kg | 190 ₹760 | 180 ₹720 | 185 ₹740 | 180 ₹720 | 185 ₹740 | 190 ₹760 | 190 ₹760 | 185 ₹740 |
| 10.00 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. | 240 | Kg | 118 ₹28,320 | 130 ₹31,200 | 132 ₹31,680 | 115 ₹27,600 | 125 ₹30,000 | 120 ₹28,800 | 120 ₹28,800 | 118 ₹28,320 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Sept 2025, 6:00 pmClosed
GARRISON ENGINEER
Bengdubi Military Station PO-Bengdubi, Dist-Darjeeling, Pin 734424
REPAIR MAINTENANCE REPLACEMENT OF STREET LIGHT POLES UG CABLE JUNCTION BOX SEARCH LIGHT AND OTHER CONNECTED ITEMS AND ALLIED WORKS FOR CERTAIN UNITS AND B ZONE ALONGWITH MISC BR WORKS UNDER AGE EM AND AGE BR I OF GE BENGDUBI
2025_MES_728345_1
8712/E8
Open Tender
Civil Works
270 days
GARRISON ENGINEER BENGDUBI
Please refer NIT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER
₹90,000
Yes
10 Dec 2025
4 Sept 2025
27 Sept 2025
4 Sept 2025
25 Sept 2025
18 Sept 2025
5 Sept 2025 - 11 Sept 2025
Amount
M&L for providing precast cement concrete PCC (1:3:6) type C0 (using 12.5mm graded stone aggregate) louvres and jallies, 25mm thick (measured solid), including all mould- ings but excluding frame Set in cement mortar 1:4 complete all as specified and directed.
M&L for cement concrete 1:3:6 type C2,using 40mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and directed.
M&L for Providing, cement concrete 1:2:4 type-B1 in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones,bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed.
Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed. (Pidiproof of Dr.fixit or equivalent)
M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for brickwork with old size fly ash bricks, straight or curved on plan to any radius as in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
M&L for MS work in posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 and similar work complete all as specified and directed.
M&L for MS framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S&F Mild steel screw bolts Diameter of neck in 5 to 10mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and n exc 15cm long complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F MS framed work confirming to Fe 410 -W quality A as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all as specified and directed.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (each line wire to be measured)
S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (each line wire to be measured)
Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and directed.
M&L for 75mm thick PCC type D2,1:4:8 using 40mm graded stone aggregate as in sub base of PCC floor/path complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for two coats of synthetic enamel paint over one coat of red oxide on new steel surfaces of any description over 10cm in width or girth including preparation of surfaces complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of cement concrete in ground floor and paving n.exc 15 cm thickness( below or above ground level) complete all as specified and directed.
Demolition of cement concrete (reinforced ) of any description and in any position not exceeding 15 cm thick, including removal complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of fencing any type complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground Posts embedded in natural ground complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size nconfirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over and including 25mm thick sand filling layer well rammed and compacted complete all as specified and directed,
M&L for pre polished cement concrete chequred tile with grey cement and no pigment of approved quality size 300X300X 25mm thick on floors over and including 20 mm thick screed bed cement mortar 1:6 set and jointed in neat cement slurry and pointed with colour to match the tiles complete all as specified and directed.
M&L for rendering 20 mm thick in two layers of 10mm thick and 10mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface finsihed even and smooth (without using extra cement) mixed with water proofing compound as per manufacture instruction etc. complete all as specified and as directed. Notes : WPC shall be measured and paid seperately under respective item of this schedule.
M&L for rendering 10 mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instruction on fair surfaces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and directed. Note :- The water proofing compound shall be measured and paid separately under respective item of this schedule.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkai resistant primer complete all as specified and directed.
Disconnecting and taking down existing any type of street/ security/flood lights fitting of any make or any capacity for repairs or replacement of burnt / worn out accessories (LED driver, SPD etc) by using ladder or any other system from GI bracket of LT pole/ of any height, size or decorative swan neck type pole/ bracket and refixing the same after cleaning, general overhauling ,repairing and making serviceable and refixed the same in same location or any other location and testing with replacement of cable if required complete all as specified and directed. Note :- (a) Contractor should have to recevied complaint through day to day from MES Power House and attend the complaint within 24 hrs. (b) Spare parts and connection cable will be measured and paid seperetly on relevant items as under this BoQ.
Supply only Surge Protection device (SPD) 10 KV, 5KA 240 volts water seal type suitable for LED industrial and outdoor street/security light fitting above 90 watt complete all as specified and directed.
Supply only LED outdoor drivers of capacity 60/72/75 watt 240 volts suitable for outdoor street/security/flood light including all necessary fixing accessories complete as per site existing make and model of light fitting complete all as specified and directed. Note : Make of driver shall be same as per make of light fitting.
Supply only LED outdoor drivers of capacity 80/90 Watt 240 volts suitable for outdoor street/security/flood light including all necessary fixing accessories complete as per site existing make and model of light fitting complete all as specified and directed. Note : Make of driver shall be same as per make of light fitting.
Supply only LED outdoor divers of capacity 100/120/140 Watt 240 volts suitable for outdoor street/security/flood light including all necessary fixing accessories complete as per site existing make and model of light fitting complete all as specified and directed. Note : Make of driver shall be same as per make of light fitting.
Supply only LED outdoor divers of capacity 150/200 Watt 240 volts suitable for outdoor flood light including all necessary fixing accessories complete as per site existing make and model of light fitting complete all as specified and directed. Note : Make of driver shall be same as per make of light fitting.
Supply only PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) of size 1.5 Sqmm 3 Core (Nominal Area) from pole junction box to light fitting with suitable size copper cable lugs and connector all complete as specified and directed.
Supply only PVC insulated and sheathed (ISI marked) stranded alluminium conductor 4.0 Sqmm size, 2 core flat cable for street light connection from fitting connector to over head line including all fixing arrangement, complete all as specified and directed.
Supply and erecting steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9.0 meter long) complete, Including disconnecting and taking out old damage Steel/PCC pole all as directed. Note : Excavation & Earth work and PCC foundation/base shall be measured and paid separately under relevant items of this BoQ.
Taking down old unserviceable Security/street/flood light fittings of any type/model including associated accessories from 8.5/9 mtr pole/Top of the building/ other similar situation and keep in safe costudy for depositing the in MES store yard complete all as specified and directed.
Supply and fixing LED light fitting for street/security lighting energy saving & environmental friendly long life versatile pressure die-cast aluminium housing with toughened glass and individual high lumen LED with secondary optics of capacity 60 Watt with minimum 120 Lm/watt, 240 volts AC 50 Hz BIS mark potted driver , IP 66 protection suitable for 40 mm dia GI pipe bracket including five years on site warranty from manufacturer complete all as specified and directed.
Supply and fixing LED light fitting for street/security lighting energy saving & environmental friendly long life versatile pressure die-cast aluminium housing with toughened glass and individual high lumen LED with secondary optics of capacity 70/72 Watt with minimum 120 Lm/watt, 240 volts AC 50 Hz BIS mark potted driver , IP 66 protection suitable for 40 mm dia GI pipe bracket including five years on site warranty from manufacturer complete all as specified and directed.
Supply and fixing LED light fitting for street/security lighting energy saving & environmental friendly long life versatile pressure die-cast aluminium housing with toughened glass and individual high lumen LED with secondary optics of capacity 90 Watt with minimum 120 Lm/watt, 240 volts AC 50 Hz BIS mark potted driver , IP 66 protection suitable for 40 mm dia GI pipe bracket including five years on site warranty from manufacturer complete all as specified and directed.
Supply and fixing LED flood light fitting energy saving & environmental friendly long life versatile pressure die-cast aluminium housing with toughened glass and individual high lumen LED with secondary optics of capacity 150 Watt with minimum 120 Lm/watt, 240 volts AC 50 Hz BIS mark potted driver , IP 66 protection including five years on site warranty from manufacturer complete all as specified and directed.
Supply and fixing LED light fitting for street/security lighting energy saving & environmental friendly long life versatile pressure die-cast aluminium housing with toughened glass and individual high lumen LED with secondary optics of capacity 200 Watt with minimum 120 Lm/watt, 240 volts AC 50 Hz BIS mark potted driver , IP 66 protection suitable for 40 mm dia GI pipe bracket including five years on site warranty from manufacturer complete all as specified and directed.
Refixing of Security/street/flood light fittings of any type/model including associated accessories to 8.5/9 mtr pole/Top of the building/ other similar situation obtained from item no 40.00 complete all as specified and directed.
Supply and fixing LED Post top light fittting luminaires 40/45 Watts IP 65 type made in die-cast aluminium housing with decorative opal/clear polycarbonate diffuser complete with control gear box suitable for 50 mm dia post and all accessories duly prewired and connecting to junction box and testing complete all as specified and as directed.
Supply & fixing LED bollard 9/10 watts IP 65 rated inverted pyramid tripod type with robust design and efficient 360 degree light distribution made in die-cast aluminium housing with decorative opal polycarbonate diffuser complete with control gear box and all accessories duly prewired and connecting to junction box and testing complete all as specified and as directed.
M & L for decorative type single arm street light bracket made out of mild steel medium grade MS pipe 125 mm dia 0.40 mtr length suitable for fixing into top of the steel tubular pole and mild steel medium grade 40 mm dia 1.40 mtrs length and shape by cutting, welding and well finishing with drilling, hole, jointing of neccessary 6 mm sheet metal corner support top cover and also inside the pipe and fixing with 12 mm dia 03 nos nuts & bolts duly welded at bottom parts for tightening bracket on pole including necessary painting with two coats aluminium paint over a coat of red oxide primer and necessary cutting/hole to existing pole and dismantling of old unserviceable bracket of any size and shape complete all as specified and as directed. Note : Design and drawing of street light bracket may required to submit before fabrication for approval of accepting officer.
M & L for decorative type single arm street light bracket made out of mild steel medium grade MS pipe 80 mm dia 0.40 mtr length suitable for fixing into top of the steel tubular pole and mild steel medium grade 40 mm dia 1.40 mtrs length and shape by cutting, welding and well finishing with drilling, hole, jointing of neccessary 6 mm sheet metal corner support top cover and also inside the pipe and fixing with 12 mm dia 03 nos nuts & bolts duly welded at bottom parts for tightening bracket on pole including necessary painting with two coats aluminium paint over a coat of red oxide primer and necessary cutting/hole to existing pole and dismantling of old unserviceable bracket of any size and shape complete all as specified and as directed. Note : Design and drawing of street light bracket may required to submit before fabrication for approval of accepting officer.
M & L for decorative type double arm street light bracket made out of mild steel medium grade MS pipe 125 mm dia 0.40 mtr length suitable for fixing into top of the steel tubular pole and mild steel medium grade 40 mm dia two nos 1.40 mtrs length each arm and shape by cutting, welding and well finishing with drilling, hole, jointing of neccessary 6 mm sheet metal corner support top cover and also inside the pipe and fixing with 12 mm dia 03 nos nuts & bolts duly welded at bottom parts for tightening bracket on pole including necessary painting with two coats aluminium paint over a coat of red oxide primer and necessary cutting/hole to existing pole and dismantling of old unserviceable bracket of any size and shape complete all as specified and as directed. Note : Design and drawing of street light bracket may required to submit before fabrication for approval of accepting officer.
M & L for street light bracket made out of GI pipe light grade 40 mm dia 1.5 metre length bent to shape and reduced to required size at top upto 1.5 metre length by cutting, welding and well finishing including MS clamp of flat iron of size 40x6 suitable length 2 sets complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats of aluminium paints over a coat of red oxide primer including dismantling of old unserviciable one complete all as specified and as directed.
Refixing street light bracket of any size, shape or description to the any size of pole obtained from respective items to new place or existing place alongwith new nuts, bolts and washer complete all as specified and as directed.
Supply and fixing pole mounted SMC junction box/bus bar chamber for loop IN/OUT connection of street light cable of size 295x195x100 mm high heat distoration temperature, non-fusing , shockproff, rustproof, 100 % weatherproof, fire retardant- class FV-O as per IS 11731 Part-II and suitable locking arragement with three phase and neutral aluminium busbar of size 20X3 mm of length 170 mm wrapped with PVC sleeves with maintained the colour code, MCB DIn rail channel for mouting of one no MCB SP and provision of making holes with GI nuts, bolts & washers for cable connections mounted on hydrograpic insulators with nuts & bolts at both ends of busbar and fixed on pole steel/PCC with suitable two nos flat iron clamp 25x4 mm with nuts and bolts (duly painted with two coats of aluminium paint over a coat of red oxide primer) and dismantling of old unserviceable one complete all as specified and as directed.complete all as specified and directed.
Supply and fixing in repair PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) of size 1.5 Sqmm 3 Core (Nominal Area) from pole junction box to light fitting with suitable size copper cable lugs and connector all complete as specified and directed.
Supply and fixing in repair PVC Sheathed multi stranded unarmed copper conductor cable LT 1100 volt grade Conforming to IS 7098 FRLS (inner sheet) of size 2.5 Sqmm 3 Core (Nominal Area) from pole junction box to light fitting with suitable size copper cable lugs and connector all complete as specified and directed.
Supply and fixing in repair PVC insulated and sheathed (ISI marked) stranded alluminium conductor 4.0 Sqmm size, 2 core flat cable for street light connection from fitting connector to over head line including all fixing arrangement, complete all as specified and directed.
Supply and fixing in repair of Three phase 8 KW automatic street light control switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation should be based on Natural Light Lux level. Switching off illuminance level should be of minimum 30 Lux and Switching on illuminance should be less than or equal to 10 LUX. The sensor should also have part night operation facility of min 4 hrs to maximum 12 hrs. The circuit shall have a provision for manual over ride operation. The sensor along with suitable power contactors and incoming-outgoing MCBs should be enclosed in a pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP 66 complete all as directed by GE.
S & F in replacement power contactor 3 pole, 40 Amps capacity panel mounting with entry terminals complete all as specified and directed.
Supply and fixing in repair MCB TPN 50 to 63 amps 10 KA ,C-series including connection with suitable size aluminium / copper lugs complete all as specified and directed .
Supply and fixing in repair MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs complete all as specified and directed .
Supply and fixing in repair MCCB adjustable thermal magnetic release type, 4 poles, 415 Volts, Lcu = 100% Ics, 25 KA breaking capacity of rating 63 Amps including all fixing accessories with both ends spreader links complete all as directed.
Dismantling of ACSR or AAC conductor from LT service feeder or distribution line complete all as specified and directed.
Dismantling cross arms of MS channels or angle sections etc complete all as specified and directed.
Dismantling insulators any type any sizes complete all as specified and directed.
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .
Supply,laying & fixing in repair double wall corrugated (DWC) pipes of size 63 mm outer dia conforming to IS 16205 (Part-24) including all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc all as specified and directed by GE.
Relaying of old serviceable brick as in cable protection complete all as specified and directed.
M&L for taking out old unserviceable cable of any size , GI pipe protection, bricks including separating serviceable bricks & set aside and removing un-serviceable bricks from position all complete as specified and as directed.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm 4 core with all fixing & connecting accessories such as aluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe brick protection etc shall be measured and paid separately under relevant items of this schedule 'A' part).
All as per item no.70.00 but Size 16 Sqmm X 4 core
Relaying of old serviceable UG cable of any size obtained from item no 69.00 complete as specified and as directed.
Excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as specified and as directed.
Excavating in trenches exceeding 1.5 m wide and not exceeding 3 m depth and not less than 1.5 m in depth for laying of cables & foundation of poles , stay assembly and getting out in any type of soil complete all as specified and directed .
Returning filling including spreading levelling watering & well Ramming in layers not exc 25 cm complete all as specified and as directed.
Removing excavated material not exceeding 50 mtr & deposited where direceted at a level not exceeding 1.5 mtr above the ground level complete all as specified and as directed.
M/L for bricks common burnt sub class B designation for protection of cable complete all as specified and as directed.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
M&L for cement concrete 1:4:8 type D2, using 40mm graded stone aggregate as in foundations filling and mass concrete complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete.
M&L for RCC(Nominal mix) type B1, 1:2:4 (using 20mm graded stone aggregate) as in foundation,including afts, footings, foundation beams plinth beams bases for columns etc. complete all as specified and directed.
M&L for RCC(Nominal mix) type B1, 1:2:4 (using 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts etc. complete all as specified and directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical to rough finished surface complete all as specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete, square, rectangular or polygonal in shape complete all as specified and directed.
Supply and fixing in repair epoxy resin 4 way terminal connector with nuts, bolts and washer for 16 sqmm UG cable including fixing to stret light junction box complete all as specified and as directed.
M&L for repair of street light pole junction box including decarbonisation and tightening the loose connection of end terminals of street light fitting, Flood light, Post top lanten of any size/capacity at any height and refixing the same with PVC 2 way connector after the cleaning refreshing the join etc and make the light functional complete all as specified and directed.
Supply, fixing and testing in repair of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 16 to 10 sqmm 4 core cable complete all as specified and as directed.
Supply, fixing and testing in repair polyolefin heat shrink LT cable sleeve with colour coding (Red, Yellow, Blue & Black) suitable for 1100 volts grade for XLPE, armoured, aluminium conductor of cable size 10 to 16 sqmm complete all as specified and as directed.
M&L for alignment of galvanised lantern carriage arrangement for luminaires of high mast pole any size and any location with the help of hydra or other source which are locked/disalignment due to wind complete as specified and directed.
M&L for rewinding of reversible Motor capacity 1.5 HP any make used for lowering and hosting the carriage of luminaires for repair complete as specified and directed.
M&L in replacement of Motor capacity 1.5 HP for hosting and loweing of lantern carriage for repair of light from high mast pole complete as specified and directed.
Supply and fixing in repair LED type 8 watt double aviation light IP 65 on high mast pole/water tank/high rising building complete all as specified and directed.
(Note : The Scope of Work contained in 'Sch of Credit' amounting to Rs. 1,04,465.00 (refer Tender Srl Page No 29). The Quoted sum shall be arrived at after deducting the amount of “Sch of Credit” from the total amount of the ‘BoQ’
KD SAHA and CO.INDIA (BID ID -3431461)
M/S P. RAI CHOUDHURY AND CO. (BID ID -3435157)
SRI A B SEN (BID ID -3433892)
M/S Joy Construction (BID ID -3432615)
MESSERS BEE GEE CONSTRUCTION (BID ID -3434335)
Prahalad Rai (BID ID -3435153)
M/S Vaishno Constructions (BID ID -3432240)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid