| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹47.6 LAdmitted-Finance | -6.66% | ₹47.6 L | L1 | Admitted-Finance |
| 2 | L2₹47.9 LAdmitted-Finance | -6.06% | ₹47.9 L | L2 | Admitted-Finance |
| 3 | L3₹49.9 LAdmitted-Finance | -1.99% | ₹49.9 L | L3 | Admitted-Finance |
Tender Value
₹60.1 L
EMD Value
₹1.2 L
Closing Date
30 Apr 2026, 6:00 pmClosed
Executive Engineer
PWD Electrical Division I Jaipur
Electrical Repair and Maintenance Work towards installation of ACs at Bani Park Court Campus, Jaipur Metro court I, Jaipur
2026_CEPWD_554439_3
NIT NO 02 of 2026-27 EE PWD E-I Jaipur
Open Tender
Electrical Works
60 days
Jaipur
Please refer tender documents
2 documents required · 2 mandatory
₹1,000
Through Egras Challan in Office ID 4222
₹1.2 L
Yes
In the Chamber of Executive Engineer
2 May 2026
27 Apr 2026
1 May 2026
27 Apr 2026
30 Apr 2026
27 Apr 2026
28 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. 20 mm | 1,500 | Mtr. | 33 | ₹49,500 |
| 2 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. 25 mm | 2,300 | Mtr. | 47 | ₹1,08,100 |
| 3 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. 32 mm | 800 | Mtr. | 70 | ₹56,000 |
| 4 | Add extra in item no. 11.1 to 11.4 for Laying Charges for cable through Manual Boggi by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required. | 100 | Mtr | 133 | ₹13,300 |
| 5 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.240.0 Sq. mm.3.5 core | 15 | Mtr | 1,523 | ₹22,845 |
| 6 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.400.0 Sq. mm.1 core | 90 | Mtr | 826 | ₹74,340 |
| 7 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.400.0 Sq. mm.3.5 core | 570 | Mtr | 2,372 | ₹13,52,040 |
| 8 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.35.0 Sq. mm.3.5 core | 800 | Mtr | 323 | ₹2,58,400 |
| 9 | Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. | 750 | Mtr | 31 | ₹23,250 |
| 10 | Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 185 sq. mm and upto 400 sq. mm fixed with 50 mm x 5 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. | 550 | Mtr | 120 | ₹66,000 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx