| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being L1 and Most reasonable | |
| 2 | L2₹5.3 L+₹20,850 (4.11%)Rejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being Not L1 | |
| 3 | L3₹6.5 L+₹1.4 L (28.4%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance Being Not L1 | |
| 4 | L4₹7.5 L+₹2.4 L (47.2%)Rejected-Finance 58 1ST FLOOR PATEL NAGAR BATHINDA | BATHINDA | BATHINDA | PUNJAB | L4 | Rejected-Finance Being Not L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical Documents are not in Order, Requisite Category not found. |
Tender Value
Refer Docs
EMD Value
₹16,400
Closing Date
28 Nov 2022, 6:00 pmClosed
AGE(I) DALHOUSIE
AGE(I) DALHOUSIE PIN-176305
SPL REPAIR TO METER BOXES, TPN / SPN DISTRIBUTION BOARD AND SUBMAIN WIRING/ CIRCUITS AT ORS MD ACCN AT MH PHASE-I AREA BLDG NO. 27 51 52 53 54 56 57 58 59 60 61 62 AND 63 AT MH UNDER AGE I MES DALHOUSIE
2022_MES_560347_1
8913/2022-23/E8
Open Tender
Civil Works
Item Rate
120 days
AGE(I) DALHOUSIE
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) DALHOUSIE
₹16,400
Yes
AGE(I) DALHOUSIE
15 Mar 2023
29 Oct 2022
30 Nov 2022
29 Oct 2022
28 Nov 2022
14 Nov 2022
29 Oct 2022 - 9 Nov 2022
9 Nov 2022
Amount
Material and labour factory made sheet metal enclosure dust and vermin proof made out of 2.00mm thick Ms sheet of size 100x60x25 cm depth with double door hinged shutter and locking arrangement for fixing DBs,KWH meter etc flushed/semi flushed /grouting on wall as per site requirement including DIN rail channel for mounting of MCB,s SP/SPN. And provide in 4 rows TPN aluminium bus bar channel of rating 200 Amps duly mounted on 'F' class insulator with colour coded heat shrinkable sleeves and powder coated paint with suitable for one no for incoming of FP MCCB with internal connection of 16 sq mm multistrand copper wire with copper lugs from MCCB to Busbar etc. after prepration of surfaces with suitable glass vision panel complete all as directed (Note: Unit rate shall be inclusive of making good the area not exceeding 0.6 sqm and not exceeding 0.125m depth for filling the hollow existing surface with half bricks in CM (1:4) including taking down old unsv any type of sheet metal enclosure or main switch complete all as specified and as directed by Engr-in- charge.
S&F in repair Moulded case circuit Breaker (MCCB) TP Fixed type capacity 63 Amps ,415 Volts 50 HZ 10 KA including making necessary connection with spreader, link and copper lugs including taking down old unserviceable MCCB/ main switch of any capacity and make complete all as specified and as directed. Make:- C&S / Havells /Legrand /Indoasian/Standard
Supply & Fixing in replacement Sheet metal enclosure for DB,s, double door (when MCB,s to be used) single pole & neutral 08 way with 200 amps rated bus bar 240 volts with fixing arrangements. Make- C&S/Havells/Indoasian/Legrand
Supply and fixing inreplacement MCB single pole and neutral 6 to 32 Amps, 240 volts complete all as specified and directed.
Supply and fixing MCB single pole 6 to 32 Amps, 240 volts all as spd and directed. Make C&S, Havells, Legrand, L&T
M & L for power point 3 pin switch socket 15 Amp with PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm on independent board including one run of 2.5 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in concealed PVC conduit of appropriate size and best quality ISI marked, including suitable size of copper lugs and all other required accessories as specified in preamble 1(a) to 9(q) of Section-19 od SSR Part-ii under " Point wiring" fixed on wall including sunk cast iron terminal boxes grouting/ flushing on wall for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover, complete all as specified and directed by Engr-in-charge.
M & L for sub main wiring with 6.0 sqmm copper conductor cable multistrand, PVC sheathed four run (as phase and neutral) and two run 4.0 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in drawn in one PVC concealed conduit wiring in Brick machinary / Stone machinary wall complete including cutting, chasing, pinning and making good the disturbed surfaces by using cement mortor 1:3 of wall by providing cement plaster and matching the surfaces by white wash / colour wash all as per existing finishes complete all as specified and directed by Engr-in-charge.
Disconnecting/ Dismantling of Electric Energy Meter of any capacity from site and keep it in safe custody and refix with Submain/circuits the same in its existing position etc complete al as specified and as directed by Engr-in-Charge.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600x600x6.00mm thick burried directly in ground any type of soil including rocky soil also(earth pit not less than 2.25 Mtrs below ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to GI earth lead wire of 4.0 mm dia by means of bolts, nuts, check nuts, as earth lead complete including 40 mm bore dia protection pipe GI medium grade upto 7.5m length, watering pipe 15mm bore dia GI medium grade 1.70m length, charcoal & salt filling, necessary earth work in any type of soil including rocky soil also, concrete pit, funnel removal of surplus soil upto 50m distance all as per electrical plate No.3 of SSR Part I and connected to earthing test point, main board including testing on completion all as specified and directed.
M/S SHRI RAM BUILDERS
VIRAT CONSTRUCTIONS
M/S RUDRA CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .