Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | ₹22.5 L | L1 | Accepted-AOC THE LOWEST TENDERER |
| 2 | L2₹23.6 L+₹1.1 L (4.85%)Rejected-Finance | ₹23.6 L+₹1.1 L (4.85%) | L2 | Rejected-Finance NOT THE LOWEST TENDERER |
| 3 | L3₹29.4 L+₹6.9 L (30.5%)Rejected-Finance PLOT NO 8 PREMA APARTMENT VEDANTNAGAR CHHATRAPATI SAMBHAJINAGAR 431 007 M S | CHHATRAPATI SAMBHAJINAGAR | CHHATRAPATI SAMBHAJINAGAR | MAHARASHTRA | 431007 | ₹29.4 L+₹6.9 L (30.5%) | L3 | Rejected-Finance NOT THE LOWEST TENDERER |
| 4 | L4₹29.7 L+₹7.1 L (31.7%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | ₹29.7 L+₹7.1 L (31.7%) | L4 | Rejected-Finance NOT THE LOWEST TENDERER |
| 5 | L5₹37.9 L+₹15.3 L (68.1%)Rejected-Finance | ₹37.9 L+₹15.3 L (68.1%) | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹87,600
Closing Date
15 Mar 2023, 6:00 pmClosed
GE MH AND RH KIRKEE
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Kirkee Pune 411003
REP REWIRING OF OTM MD ACCN INCL REPAIR REPLACEMENT OF ELECTRIC ENERGY METER CEILING FAN EXHAUST FAN GEYSER SOLAR WATER HEATER IN INSP ORG AND REPAIR MAINT OF DG SET AMF PANEL AND ITS CONNECTED WORKS IN DGQA LOCATION UNDER GE MH AND RH KIRKEE
2023_MES_581669_1
8343/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE MH AND RH KIRKEE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KIRKEE
₹87,600
23 May 2023
17 Feb 2023
17 Mar 2023
17 Feb 2023
15 Mar 2023
3 Mar 2023
17 Feb 2023 - 8 Mar 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking into credit and making good disturbed surfaces of walls, floors etc all as directed.
M&L for point wiring complete with 1.5 Sqmm 1100 volts grade single core FRLS PVC insulated unsheathed cable with multi stranded copper conductor as per IS 694 (1990) drawn through and including PVC casing & capping of suitable size on walls/ ceiling etc and including one continuous run of 1.5 sqmm PVC insulated Multistranded copper cable green colour as earth continuity conductor connected to common earth dolly including 1.22 mm thick pressed steel terminal boxes of suitable thickness, 3mm thick laminated sheet cover to house switch/ regulators etc for all as specified and directed.
One fan/light /bell point controlled by one 5 Amps one way switch/bell push
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
All as per item No 2 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated copper cable (green colour) as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as directed.
All as per item No 2 here-in- before but with 4 Sqmm PVC insulated multistranded copper conductor with 4 sqmm PVC insulated copper cable (green colour) as earth continuity conductor for Power Socket on independent board all as directed.
M&L for point wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 V grade multi stranded copper conductor as per IS 694 (1990) drawn through non metallic rigid PVC conduit and accessories in surface of walls/ceilings/concealed 1.5 Sqmm dia multistranded copper cable as earth continuity conductor (green colour) connected to common earth dolly, including 1.22 mm thick pressed steel terminal boxes of suitable thickness, 3 mm thick laminated sheet cover to house switch/regulators etc all as specified and directed.
One fan/light /bell point controlled by one 5 Amp one way switch/bell push
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
All as per item No 5 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated copper cable (green colour) as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as directed.
All as per item No 5 here-in- before but with 4 Sqmm PVC insulated multistranded copper conductor with 4sqmm PVC insulated copper cable (green colour) as earth continuity conductor for power Socket on independent board on the existing/new PVC surface conduit all as directed.
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 4 sqmm 1100 volt grade drawn into PVC Cassing capping of suitable size including 4 sqmm. PVC multi standard copper conductor FRLS cable in green colour for continious earthing on surface including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note: Two runs of single core cable 4 Sqmm, one run of earth wire 4 Sqmm and one run of PVC casing caping shall be measured as one unit length.
M&L for sub main wiring but using two single core multistranded PVC insulated copper conductor FRLS Cable of size 6 sqmm 1100 volt grade drawn into PVC Cassing capping of suitable size including 6 sqmm. PVC multi stranded copper conductor FRLS cable in green colour for continious earthing on surface including chislling/cutting of wall, floor, making hole through wall & making good disturbed surfaces of wall/floor/ceiling to match with existing surface including taking down old unserviceable/burnt wiring of any type or size all as directed by Engr-in-Charge. Note: Two runs of single core cable 6 Sqmm, one run of earth wire 6 Sqmm and one run of PVC casing caping shall be measured as one unit length.
Supply and fix ceiling rose surface bakelite with three terminals complete including taking down rusted metal box and necessary platering work and finish with existing wall paint all as specified and directed.
Supply and fix switch piano type one way 6 Amps flush type, 240volt AC all as specified and directed.
Supply and fix socket outlet 2 in1,3 pin 5 Amps all as specified and directed.
Supply and fix switch socket combination(SSC) 2 in 1, 3 pin, 5 Amps flush type, 240volt AC all as specified and directed.
Supply and fix switch piano type 16 Amps flush type, 240volt AC all as specified and directed.
Supply and fix socket outlet 2 in 1, 3/ 5 pin 16 Amps flush type all as specified and directed.
Supply and fix switch socket combination(SSC) 2 in 1, 3/5 pin, 16 Amps flush type, 240volt AC all as specified and directed.
Supply and fix bell push, flush type, 6 Amp flush type, 240volt AC all as specified and directed.
Supply and fix switch piano type two way 6 Amps flush type, 240volt AC all as specified and directed.
Supply and fix bell push, Modular type, 6 Amp flush type ,240volt AC all as specified and directed.
Supply and fix in repair modular switch 1 way 6A 1 module complete all as specified and directed.
Supply and fix in repair modular switch 2 way 6A 1 module complete all as specified and directed.
Supply and fix in repair modular socket 6A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular socket 6A /16A 2/3 pin combined 2 module complete all as specified and directed.
Supply and fix in repair modular fan regulator,120 watt - 2 module complete all as specified and directed.
S & Fix in repair stepped type electronic fan regulator 120 watt ,240 olt flush type on the existing phenolic laminated sheet
Supply and fix in repair electric bell Ding Dong, AC 230 volts complete all as specified and directed.
Supply and fix in repair Modular white cover plate with frame 1module complete all as specified and directed.
Supply and fix in repair Modular white cover plate with frame 2 module complete all as specified and directed.
Supply and fix in repair Modular white cover plate with frame 3 module complete all as specified and directed.
Supply and fix in repair Modular white cover plate with frame 4 module complete all as specified and directed.
Supply and fix in repair Modular white cover plate with frame 6 module complete all as specified and directed.
Supply and fix in repair Modular white cover plate with frame 8 module complete all as specified and directed.
Supply and fixing replacement of RCCB 63 A , four pole, 100 mA all as specified and directed by Engr-in-chrge. Make: Hager/L & T/Standard
Supply and fix in industrial wall mounted plug socket in repair suitable fotr IP 44 degree of protection of 32Amps rating 3p+N +E all as specified and directed. Make: L&T cat part DBPPS563SD or other equivalent make all as specified and directed
S & F sheet metal enclosures in repair for double door distribution board factory made duly painted 12 way SPN and neutral 240 v with 200 amps rated bus bar, suitable for fixing MCB /Isolators all as specified
S & F sheet metal enclosures in repair for double door distribution board factory made duly painted 8 way SPN and neutral 240 v with 200 amps rated bus bar, suitable for fixing MCB /Isolators all as specified
S & F sheet metal enclosures in repair for double door distribution board factory made duly painted 8 way TPN and neutral 415V with 200 amps rated bus bar, suitable for fixing MCB /Isolators all as specified
S & F in repair of capacity MCCB 125 Amps, 4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity
Supply and fixing miniature circuit breaker (MCB) in repair of single poles and current carrying capacity 5 to 32 AMP240V, 10 KA 'B' curve , in the MCB DB Complete with connection testing and commissioning.
All as per item No 39 above but SP 40 AMP.
All as per item No 39 above but SPN 32 Amps.
All as per item No 39 above but SPN 40 Amps.
All as per item No 39 above but TPN 63Amps.
Labour only for attending MES complaints received through Mobile App/complaint slip with 01 skilled electrician and 01 Helper for one shifts from 0830 Hrs to 1730 hrs on all working days at CQA EE tech, CQA residential,MAnu vihar, Gunta vihar, CQAFE tech, NBC wing, VQAWL, SQAEL, DI cell<CQAME tech Aea etc Note: - (i) The complaints shall be entered in complaint slip by JE E/M / MCM. (ii) The complaint slip shall be returned to JE E/M on completion of the work with stores consumed. (iii) Any delay in attending the complaints for more than 03 days, a penalty of Rs 50/- per complaint shall be adhered to the contractor. (iv) The details of stores consumed, complaint slip are to be produced during the RAR bills. (v) T & P, minor spares like nuts, bolts, screws, washers required for attending the complaints shall be provided by the contractor. (vi) Job card register and complaint register should provided by contractor to note down the MES complaint
Taking down carefully old unserviceable existing Aluminium strip of size 25 mm x 3 mm and Supply & fix Aluminium strip 25 mm x 3 mm complete with saddles and fixing screws for fitting the strip all as specified and directed.
Taking down carefully old unserviceable existing Galvanised iron strip 32 mm x 6 mm and Supply & fix Galvanised iron strip 32 mm x 6 mm complete with saddles and fixing screws for fitting the strip all as specified and directed.
M&L for Air terminations single pointed Aluminium rod 12 mm dia in repair and 300 mm long with necessary fixing arrangements on roof including taking down old all as directed.
M&L for Air terminations single pointed copper rod 12 mm dia in repair and 300 mm long with necessary fixing arrangements on roof all as directed.
Supply and fix test point terminal block in repair made out of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. head screw including taking down old all as spcified and directed by Engr- in - Charge.
M &L for repair, replacement of damaged, rusted cast iron/pressed steel terminal boxes on inside wall S & F Cast iron/pressed steel terminal boxes 60 mm deep 75 mm x 75 mm Square size and cutting sheet for mounting removed existing and new switches, sockets, fan regulator, etc with 3 mm thick plastic laminated sheet cover making surface good with cement plaster or POP all as specified and directed by Engr-in-charge.
All as per item No 50 Above 100mmx100mm above
All as per item No 50 Above 150 mm x 75 mm above .
M & L for Hot water water supply pipe duly insulated with glass wool and aluminium cladding on GI pipe complete15 mm bore all specified and directed by engr in charge.
S & F in repairs wall mounted extruded aluminium housing high quality indoor batten LED tube 20 watt colour temperature 6500 K (4" long) lumen 2000 -3000, PF> 0.95, THD less 10% diffused connecting with three core flexible copper wire from connecto to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge.
S & F in repairs wall mounted extruded aluminium housing high quality indoor batten LED tube 10 watt colour temperature 6500 K (4" long) lumen 2000 -3000, PF> 0.95, THD less 10% diffused connecting with three core flexible copper wire from connecto to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge.
S & F in repairs recess mounting LED flat panel light fitting 36 watt, 2 x 2 , 600mm x 600 mm size with efficient LEDs lumen 2000 -3000, PF> 0.95, THD less 10% including necessary eletric connection with PVC insulated multistranded copper cable os size 1.5 sqmm 3 core from ceiling rose to fitting terminal complete all as specified and directed.
S & F in repairs recess mounting LED flat panel light fitting 18/20 watt, 1' x 1', 300 x 300 mm size with efficient LEDs lumen 2000 -3000, PF> 0.95, THD less 10% including necessary eletric connection with PVC insulated multistranded copper cable os size 1.5 sqmm 3 core from ceiling rose to fitting terminal complete all as specified and directed.
All as per item No 56 above circular in size 18/20 watt as per existing site requirement but not less then 6'' dia
S & F in repair wall mounted high quality indoor wall bracket light cylinderical/ oval shape aesthetically designed fitting with B22 lamp holder and 12 Watt bulb temp range 4000k to 6500 K as per site requirement connecting with three core flexible copper wire as directed by Engr-in-charge.
S & F for repair and replace of unserviceable LED driver suitable for 36/40 watt LED panel light fitting 2 x 2 size on site all as specified and directed by Engr-in-Charge.
Taking down old unserviceable Bldg security light S&F fix high efficent LED building security light 30 watt, 230 V, lumen 2000 -3000, PF> 0.95, THD less 10%, made of pressure dia cast aluminuim housing with high power LEDs, lens and toughened glass IP 66 connecting with three core flexible copper wire from connecto to ceiling rose.
S & F in repair bracket for mounting building security light made out of 40 mm dia medium grade GI pipe bend in angle with holding MS clamps two nos each bracket of size 25x3 mm including screw etc for fixing all as specidfied and directed by Engr in charge
Taking down old unserviceable MH high bay light S & F high effiicient suspended type 150 watt, 230v, lumen 4000 -6500, PF> 0.95, THD less 10% LED bay light of die cast aluminium housing with lens embedded PC cover IP 66 with effficany not less then 120 lm/W, as per IS -10322 , high voltage cut off,open and short circuit protection including constant voltage and current LED driver all as directed. Note: Making arrangement for T & P to fixing of bay light is incluidng quoted rate.
Material and labour for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete.
M & L for repairs / re-fixing on existing or new location to storage type electric water heater (geyser) of storage capacity 25/35/50 ltrs of any make comprising of the following works mentioned here under againt Ser Nos (a) to (g) at different locations:- (a) Cost of major items such as thermal cutout, safetly valve, heating eliment, PVC pipes etc shall be measured and paid separately under relevant item of this schedule as supply only. (b) Inspection, taking down, opening (dismantling) descaling, brushing, cleaning of storage tank. (c) Examine water tightness of storage tank after cleaning. (d) Carry out operation of all stop cocks, pressure reducing valves etc. to ensures free movement of the working parts. (e) S & F Replacement of the rubber / PVC gasket to ensure water tightness. (f) Checking of safety valve (g) Testing of geysers after repairs.
Supply only thermal cutout ISI marked temp range 50-80/90 degree as required at site for geyser of capacity 25/35/50 Ltr of any make all as directed by Engr-in-charge
Supply only safety valve/high pressure valve ISI marked as per site requirement or all as per directed by Engineer-in-Charge.
Supply only heating element of rating 1/1.5 KW,240 volt as required at site including rubber washers all as specified and directed by Engr-in-charge.
Supply only heating element of rating 2 KW 240 volt as required at site including rubber washers all as specified and directed by Engr-in-charge.
Supply only of PVC pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 60 cm long for cold water connection all as specified and directed by Engr-in-Charge
Supply only metal braided PVC/CP pipe with brass hexagonal adopters both side, suitable for 15 mm dia pipe 45 CM long for hot water connection all as specified and directed by Engineer-in-charge.
S&F in repairs, non return valve 15 mm dia of brass, ISI marked all as specified and directed by Engineer-in-charge.
M & L for repairing, replacment of unserviceable copper container of capacity 25/50 Ltrs of solar water heater of any type after completion of work testing the heater all as specified and directed by Engr-in-Charge
M & L for repairing, replacment of unserviceable copper container of capacity 25 Ltrs of water heater (gyser) of any type after completion of work testing the heater all as specified and directed by Engr-in-Charge
S & F stop valve , cast copper alloy screw down high pressure crutch handle, screwed both end for iron pipe suitable for 15 mm bore all as specified and directed by Engr-in-Charge
M & L for rewinding of ceiling fan of 1200/1400 mm sweep of any make by opening the fan cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection, varnishing, making electric connection with pvc insulated multistranded copper conductor cable of size 0.5 Sqmm 3 core to fan connector and testing complete all as specified and directed by Engr-in-Charge.
All as per item No 70 above but Exhaust Fan of sweep 275-300 mm
All as per item No 70 above but Exhaust Fan of sweep 350-450 mm
All as per item No 70 above but Air circulator of sweep 350-450 mm
Taking down unserviceable ceiling fans of any make and type servicing, over hauling, oiling greasing the requisit parts and rectifying the defects including replacement of unserviceable parts and testing and reinstalling at same or any other location as directed at site by Engineer-in-charge. Notes: - (i). The unit rate is deemed to include the cost of taking down carefully fans from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard and refixing in same as different locations after repair etc complete all as directed by Engineer-in-charge. (ii) Cost of major items such as wonding, ball bearing, gun metal bush, capacitors, canopy, blades and repair/ rewinding /painting etc shall be measured and paid separately under relevant item of this schedule as supply only. (iii) Minor items or works like tightening loose connections in switch, binding insulation tape to the naked wires, replacement of unserviceable clamps, nuts and bolts, split pins, rubber reel,greasing, washers, including flexible twin core copper wire of suitable size from existing ceiling rose to fan etc complete shall be provided without any extra cost and cost of these minor items or works shall be deemed to be included in the unit rate quoted rates against this item and nothing extra shall be paid on this account.
Supply only ball bearing (DE/NDE) to match the existing make suitable for 1200/1400 mm sweep ceiling fan including greasing complete all as specified and directed by Engr-in-Charge.
Supply only capacitor 2.5 mfd for ceiling fan all as specified and as directed.
Supply only gunmetal bush suitable size for ceiling fan 1200 /1400 mm sweep complete all as specifed and directed by Engr-in-Charge.
All as per item No 74.00, but exhaust fan 275 to 450mm sweep.
Supply only ball bearing suitable for 275-450 mm exhaust fan complete all as specified and directed
Supply only capacitor 4 mfd for exhaust fan all as specified and as directed
Supply and replace, rubber yoke, MS Clamps, bolts nuts with split pin suitable for ceiling fan 1200 /1400 mm sweep complete all as specified and as directed by Engr-in-charge.
supply and replace fan down rod 1 feet long with white enammbeled painted with both side hole for hanging fan of sweep 1200/1400mm sweep all as specifeied and directed by Engr in charge
supply and replace fan down rod rod 2 feet long with white enammbeled painted with both side hole for hanging fan of sweep 1200/1400mm sweep all as specifeied and directed by Engr in charge
Supply and fix fan canopy set off white /white coloured as per colour of ceiling fan of sweep1200/1400mm all as specified and directed.
Fixing in repair aluminium strip 25 mm x 3mm complete with saddles and screws for fitting the strip.
Supply and replace hylum sheet 3 mm thick for Junction boxes, circuit boxes for various size and refixing the existing switches, sockets, regulators cut in to requied sizes including fixing with new cadmium plated screws and cup washers complete all as specified and as directed.
M & L for replacement of PVC polycarbonate rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100 x 100 mm and 50 mm deep make cutting for fixing existing switches, sockets, regulators and make necessary connection and testing complete all as specified and directed by Engr-in-Charge.
All as per item No 82 above but 200 x 150 x 50 mm deep
All as per item No 82 above but 250 x 200 x 50 mm deep
All as per item No 82 above but 150 x 150x 50 mm deep
Decarbonizing of indoor MCB / meter box any type removing unserviceable MCCBs, burnt busbars, unserviceable indicator lamps, unserviceable Ammeter, unserviceable Volt meter , replacing burnt, damaged bus bar of any size and fixing proper hanging front and rear openings, welding of hinges including welding of brokieng MS sheet using extra sheets replace burnt thimbles with new existing size thimbles replacing with new MCCB & MCBs, powder coating painting with suitable 'U' type gasket to make it dust and vermin proof, providing fancy locks incluidng dismantling the existing connected cables and re-connecting the same cables complete all as specified and directed by Engr -in- charge. Note : (i)MCCBs,indicator lamps,Ammeter, Volt meter, will be measured & paid separately as supply only . (ii) necessary MS sheet and welding incuding sealing the meter with sealing Lead/PVC seal with MES Emblum empossing on it all are inclusive coated rate. (iii) Required size of neutral bus bars including coated rate. (iv) Required size of copper cable for connecting MCBs and meters are including quoted rate.
M&L for point wiring complete with 1.5 Sqmm 1100 volts grade single core FRLSH PVC insulated unsheathed cable with multi stranded copper conductor as per IS 694 (1990) drawn through and including Stove enamelled conduit of suitable size on walls/ ceiling etc and including provn of 1.5 sqmm PVC insulated Multistranded copper cable as earth continuity conductor connected to common earth dolly including 1.22 mm thick pressed steel terminal boxes of suitable thickness, 3mm thick laminated sheet cover to house switch/ regulators etc for all as specified and directed.
One fan/lightpoint controlled by one flame proof switch
One switch socket outlet 5 Amps on independent board
One socket outlet 5 Amps on the same board
All as per item No 87 here-in-before but with 2.5 Sqmm PVC insulated multistranded copper conductor cable including 2.5 sqmm PVC insulated copper cable as earth continuity conductor for one switch socket outlet 15 Amps on independent board all as directed.
S & F Switch flame proof rotary type with termination box in LM6, 6 A, single pole 250 V, complete all as specified and directed.
S & F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16 A, 250 V 2 P+Earth complete all as specified and as directed.
M & L for repair and replacement of LED post top gate light 20W aluminium housing, clear acrylic diffuser, spun aluminium pole -cap complete with accessoires with suitable size 60 mm outer dia GI pipe and plastering work all as specified and directed cat ref cat ref HLPT-S04-20 CW Halonix make or equivalent make of Philips / jaguar
M & L for repair and replacement of LED inverter bulk head wall mounted light 10W with inbuilt long life lithiem battery IP-65 complete with accessoires all as specified and directed
M & L for rewinding of flame proof ceiling fan of 1200/1400 mm sweep of any make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection,capacitor base and testing complete all as specified and directed by Engr-in-Charge. Note: Bearing, fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule.
M & L for rewinding of flame proof exhaust fan of 275-300 mm sweep of any make by split opening the fan carrying cutting the burnt winding and cleaning the slots and rewinding with super enamelled copper winding wire appropriate gauge including connection,capacitor base and testing complete all as specified and directed by Engr-in-Charge. Note: Bearing, fan canopy, capacitor, down rod etc will be measured and paid separately under relevant item of schedule.
Maintenance and servicing of DG sets once in a month including attending faults on call basis for normal repairs including replacement of defective & worn out parts by new spares such as filters, gaskets, V-belts, Engine oil, Coolant, rubber hoses, door hinges/ lock, worm drive clamps, nuts, bolts and cleaning of alternator and attending faults of AMF panels etc and greasing of bearings of engine and alternator, checking of batteries, adding distilled water, checking and topup of oil and coolant levels etc for the following capacities of DG sets all as directed by Engineer-in Charge. Note : 1. Spares required for above maintenance shall be measured and paid separately under relevant item. 2. Servicing to be carried out as per manufacturer instruction
DG set of capacity 160 KVA, Location : CAQ EE Make : GREAVES .
DG set of capacity 100 KVA Location : NBC lab Make : CUMMINS
DG set of capacity 100 KVA Location: CQAFE Make :kirloskar
DG set of capacity 100 KVA Location : CQAME Make : model RB 66 of Kirloskar
DG set of capacity 62.5 KVA Location : CQAME Make : Model RB66 of Kirloskar
DG set of capacity 50 KVA, Make :Kirloskar
DG set of capacity 40 KVA, Location: Pump House CQAEE Make :GREAVES
DG set of capacity 10 KVA Location : SQAEL wing Make:GREAVES
Supply only diesel filter element with O ring, suitable for following capacities of DG sets:-
DG set 10 KVA
DG set 40/50 KVA
DG set 62.5 KVA
DG set 100 KVA
DG set 160 KVA
Supply only oil filter element with 'O' ring, suitable for following capacities of DG sets :-
DG set 10 KVA
DG set 40/50 KVA
DG set 62.5 KVA
DG set 100 KVA
DG set 160 kVA
Supply only by pass filter element with 'O' ring suitable for following capacities of DG sets :-
DG set 100 KVA
DG set 160 KVA
Supply only air filter element suitable for following capacities of DG sets:-
DG set 10 KVA
DG set 40/50 KVA
DG set 62.5 KVA
DG set 100 KVA
DG set 160 kVA
Supply only fan belt suitable for following capacities of DG sets :-
DG set 10 KVA
DG set 40/50 KVA
DG set 62.5 KVA
DG set 100 KVA
DG set 160 kVA
Supply only belt for battery charging alternator for DG set 160/100 kVA capacities of DG sets
Supply only rubber hose pipe set for water/Air circuit complete with clamps, suitable for following capacities of DG sets :-
DG set 10 KVA
DG set 40/50 KVA
DG set 62.5 KVA
DG set 100 KVA
DG set 160 kVA
Supply only engine oil, multi grade 15W / 40.
Supply only Petroleum jelly.
Supply only distilled water for lead acid battery
Supply only for coolent for DG Sets.
M&L cleaning/removing dirt and impurities particles of diesel tank and replacing damaged parts, nuts and bolts including cleaning and rectifying leakages of diesel and cleaning of fuel pipe for effective function of plant complete all as directed.
S & F in repair water temperature gauge including sensor and cable complete all as directed.
Dismantling of radiator from the DG set for overhauling & cleaning descaling with acid removal of leakage, welding brazing & refixing it duly repaired complete all as directed by Engineer- in- Charge for the following capacities DG sets:-
DG set 10 KVA
DG set 40/50 KVA
DG set 62.5 KVA
DG set 100 KVA
DG set 160 kVA
Calibration of FIP and injectors from the authorised dealer including petty repairs to make the FIP functional for the following capacities of DG sets including necessary spares required for smooth functioning of FIP:-
DG set 10 KVA
DG set 40/50 KVA
DG set 62.5 KVA
DG set 100 KVA
DG set 160 KVA
M&L for repair / overhauling of self starter including replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc. and varnishing complete all as directed for the following capacity:-
12 Volts self starter for DG set of capacity 10/40/50/62.5 KVA
12 Volts self starter for DG set of capacity 160/ 100 KVA
M & L for repairing of battery charging alternator engine mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, carbon brushes for the following capacities complete all as directed:-
12 Volts capacity for DG sets of capacity upto 160KVA.
M&L repair of water pump including replacement of repair kit. for 160/100 KVA DG Set
M&Lrepair of water pump including replacement of repair kit. for 62.5/50/40 KVA DG Set
Supply and fix in repair lead acid battery 12 Volts 180 AH with initial charging and having indicators to know the status of level of electrolyte complete all as directed.
Supply and fix in repair lead acid battery 12 Volts 150 Ah with initial charging and having indicators to know the status of level of electrolyte complete all as directed .
Supply and fix in repair lead acid battery 12 Volts 100 Ah with initial charging and having indicators to know the status of level of electrolyte complete all as directed.
Supply and fix in repair lead acid battery 12 Volts 80 Ah with initial charging and having indicators to know the status of level of electrolyte complete all as directed.
Supply and replace AVR for 160/100 KVA DG Set
Supply and replace AVR for 62.5/50/40 KVA DG Set
Supply and fix in repair voltage monitor regulator 10 KVA to 160 KVA DG set complete as per existing DG sets all as directed
M & L for Top Overhauling only of DG set of following capacity of Kirloskar / Cummins / Greaves and including replacement of gaskets etc complete all as specified and all spare parts required to complete the work to the entire satisfaction of Engineer-in-charge .
DG set 10 KVA
DG set 40/50 KVA
DG set 62.5 KVA
DG set 100 KVA
DG set 160 KVA
Supply and fix in repair solenoid valve suitable for following capacity DG sets for smooth functioning of DG sets complete to the satisfaction of Engineer-in-Charge
DG set 10 KVA
DG set 40/50 KVA
DG set 62.5 KVA
DG set 100 KVA
DG set 160 kVA
Supply and fix in repair microprocessor based multifunction relay suitable for DG sets operation upto capacity till 160 KVA showing the various parameters such as Volt, Ampere, frequency, RPM etc complete all as directed
M&L for dismantling the existing unserviceable alternator up to 160 KVA DG set and Transporting the same to authorised service centre removing the short circuited winding wire fully, cleaning the armature slots carefully and rewinding fully with same gauge copper winding wire, insulating with same grade and class insulating material, varnishing drying out setting back the alternator and transporting back in location, fitted to the DG set including connecting up testing and commissioning all as directed.
M&L for preparation of old painted surfaces of the Canopy/ Frame/ Exhaust Manifold/ Silencer of DG Sets complete degreasing and spray painting the same with two coats of approved synthetic enamel heat proof upto 100 Degree celcius paint of approved shade complete all as directed.
Taking out turbocharger from 160/100 KVA DG Set any make model, cleaning/removing dirt and impurities particles of turbo charger impeller and replacing damaged parts, washers, nuts and bolts and including rectifying leakages completely for effective function of DG Set and re-fix in same position and testing complete all as directed.
M&L for dismantling of lub oil tank replacement of the gaskets and refixing at original position including checking and repair to leakages in the engine side, replacement of unserviceable gasket complete all as directed
M&L servicing/repair of turbo charger including replacement of repair kit for 160 KVA DG Set
Supply and replacement of relay card for 160/100 /62.5 KVA DG Set
M&L for maintanance of AMF panel for 160/100 KVA DG Sets (On call bases or as and when required) including detailed check up, rectification of fault & maintenance /calibration of relays, replacing relays, resistors, contactors etc. to be done for Main power control panel for DG Set panel to keep the same functional all the time complete as directed.
Supply and fix 3 Pole contactor of variable 400 amp capacity coil 230 Volts with 2 NO + 2 NC and having mechanical inter locking arrangement with adjacent contactor for 160/100 KVA DG set
Supply and fix 3 Pole contactor of variable 250 Amps capacity coil 230 Volts with 2 NO + 2 NC for 62.5/50/40 KVA DG panel and having mechanical inter locking arrangement with adjacent contactor
Servincing of change over panel of capacity 250/150/100 Amps 3 Nos on half yearly basis compete installed at CQA all as specified and directed. Note : (i) Normal hardware required during servicing i.e. nut, bolt, washer, ferrul, are included in quoatated rate. (ii) cleaning material i.e. blower, rust cleaner, polish paper, grease, cotton west, thinner, are included in rate
Supply and fix door hinges of DG of any size and any capacity
Supply and fix door glass of DG of any size and any capacity
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to 32x6 mm GI strip as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber, MS funnel, wire gauge. CI cover with frame, 15 MM dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata, returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 5 of MES Sch Part I, connected to earthing test point all as specified and directed on testing on completion.
Kedar Electricals
ASHWAMEDH ENGINEERS
metro electrical services
SHREE VAIBHAV ELECTRICALS
M/S. OM ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .