Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 CrAccepted-AOC | ₹3.3 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹3.6 Cr+₹33.2 L (10.1%)Rejected-Finance 15 HOSHIYAR SINGH PARK KIRBY PLACE DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹3.6 Cr+₹33.2 L (10.1%) | L2 | Rejected-Finance Other than lowest. |
| 3 | L3₹3.8 Cr+₹52.6 L (16.0%)Rejected-Finance | ₹3.8 Cr+₹52.6 L (16.0%) | L3 | Rejected-Finance Other than lowest. |
| 4 | L4₹3.8 Cr+₹55.7 L (17.0%)Rejected-Finance | ₹3.8 Cr+₹55.7 L (17.0%) | L4 | Rejected-Finance Other than lowest. |
| 5 | L5₹3.9 Cr+₹60.9 L (18.6%)Rejected-Finance | ₹3.9 Cr+₹60.9 L (18.6%) | L5 | Rejected-Finance Other than lowest. |
Tender Value
₹3.1 Cr
EMD Value
₹3.8 L
Closing Date
22 Dec 2022, 6:00 pmClosed
CE Delhi Zone
HQ CE Delhi Zone Delhi Cantt-10
ADDN / ALTN TO BOUNDRY WALL AT 1WEC, WEE WKSP, DAS AND EETSU UNDER GE (CENTRAL) DELHI CANTT-10
2022_MES_527622_1
CEDZ/TOKEN-37 OF 2022
Open Tender
Civil Works
Item Rate
270 days
Delhi Cantt
As per Tender documents
8 documents required · 8 mandatory
₹2,000
GE (Central)
₹3.8 L
Yes
9 Aug 2023
3 Jun 2022
24 Dec 2022
3 Jun 2022
22 Dec 2022
15 Dec 2022
Amount
Excavating over areas, n exc 1.5 m deep and getting out in soft & loose soil complete all as specified and directed.
Excavating over areas, exc 1.5 m deep but n exc 3 m deep and getting out in soft & loose soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft & loose soil.
M&L PCC in foundations, filling and mass-concrete type E-2 (1:5:10) using 40 mm graded crushed stone aggregate complete all as specified and directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L RCC M-25 design mix using 20 mm graded aggregate in Columns, pillars, piers, posts and struts etc complete all as specified and directed.
RCC M-25 design mix as in Beams, cantilevers, bressumers, lintel over 1.5 m span etc complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks, M 7.5 grade exc. 10 cm in width and setting in CM 1:6, etc complete all as specified and directed.
M&L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering & well ramming in layers n. exc 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated soil exc. 50m but n exc 100m & depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter Fair finished surfaces of concrete flat etc complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns, and stanchions Rough finished surfaces of concrete Square, rectangular or polygonal etc complete all as specified and directed.
Formwork to sides & soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors & beams etc. Fair finished surfaces of concrete flat
M&L Mild steel TMT bars 10mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
M&L Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed.
M&L for 10 mm thick Rendering in CM (1:4) on fair faces of Brick or concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified and directed.
M&L for preperation of new surfaces of wall and applying two coats of cement base paint, white or tinted complete all as specified and directed.
Dismentling wrought iron or mild steel work such as grill/roof purlin etc not otherwise provided for complete all as specified & directed.
Demolition of brick work masonary, built in cement mortar. Note: The rate quoted by contractor shall be deemed to include carefully taking out bricks, seprating cleaning and stacking.
Demolition of cement concrete of any description and in any position, provided for complete all as specified.
S&F 110 mm PVC (SWR) pipes single socked in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
Frame work such as compound girders and stanchors, lattice girders, watch tower, aerial masts, staging for water tanks, and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, dusset plates, etc complete of grade confirming to Fe-410-W (Gde E-250) quality-B.
M&L for cutting shurbs wild growth/trees n exc 30 cm girth and removing complete vegetation growth from walls including taking out roots from roof/brick work and making good the disturbed surface with PCC 1:2:4 type B0/ brick bats and dispossing off the rubbish from outside MoD land complete all as specified.
M&L for cement concrete type B-2 using 40 mm graded stone aggregate (1:2:4) as in surface channels, drains etc.
M& L for forming fair finshed drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
M&L for Granite (of any type) tiles 20 mm thgick machine cut, bedded and jointed with grey cement slurry and pointed with white cement to match the shade of granite stone including 20 mm thick screed bed in CM 1:6 complete all as specified.
M&L for cement concrete 1:2:4 type B usng 12.5 mm graded stone aggregates as in roof kerbs, or mud stops, rounded or chamfered on edges, coping complete all as specified.
M&L prepration of new steel surfaces of any description over 10 cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide primer.
Description of Work / Item(s)
Amount
Supplying, install and erect in true vertical position steel tubular swaged welded pole in replacement of PCC poles , 9.0 meter long, conforming to IS-2713 part-II, type 410 SP-31, complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial taper, pole cap, bolts, nuts, washers & screws etc., pole made out of ERW M.S. tubing including of holes of reqd Nos and size for fixing of cross arms, GI pipe medium grade 40mm bore, 1.00 mtr long for cable protection up to height of pole box etc. and GI bracket made of GI pipe medium grade 40 mm bore , 1.5 mtr long for fixing of street light fitings alongwith clamps, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bends at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No the black paint by stenciled letters/figures of 8cm height complete all as specified and directed. Note: Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately in respected items.
S&F LED street light Fitting 70 watt LED, IP-66 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughned clear glass cover for lamp and control gear compartment with high voltage surge protection device up to 4.5 KV, prewired conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified and directed.
S&F KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 32A including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body Incluiding MS clamp of size 25x3 mm with suitable size nut, bolts & washer complete all as specified and directed.
M&L for laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 16 sqmm 4 Core all as per IS , specified & directed by Engr-in-charge.
M&L for laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 25 sqmm 4 Core all as per IS complete all as specified and directed.
M&L for earthing complete with galvanized Steel earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 meters below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and incl galvanized iron strip 25X4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or controll board GI pipe light grade 20mm bore for watering funnel with wire mesh PCC chamber pit in PCC 1:3:6 type C-1 40mm yhick Precast RCC -25 cover reincorced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50m complete all as sprecified and shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
M&L for earthing for poles and other machinery/eqpt in repair using GI wire as earth lead and MS galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron wire 4.00 mm dia with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt 15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protectetion, funnel with wire mesh including testing on completion, complete all as specified and directed as shown in electrical plate No 3 of SSR Part-I 2009.
Supply, drawing, connecting & testing of 3 core, 1.5 Sqmm PVC insulated and PVC rounded sheathed, copper conductor (flexible) industrial cable 1100 Volts grade conforming to IS-694 on steel tubular pole/PCC Pole from KIOSK box to light fittings including PVC conduit of suitable size and providing suitable lugs complete all as specified and directed. Note: Steel tubular pole shall be measured and paid separetely.
Excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation,laying of cable or pipe ( where provided for protection of cable or fixing with poles and stays) and getting out in any type of soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and exc. 1.5 in depth for foundation of poles, stay assy etc. and getting out in hard / dense soil complete all as specified and directed.
Removing surplus excavated soil to a distance n.exc. 50 metre and depositing where directed at a level n.exc.1.5 metre high from the starting point complete all as specified and directed.
Returning, filling in trenches in soft/loose soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed.
M&L for sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete all as specified and directed.
Supply and laying brick old size, sub class 'B' brunt bricks laid in trenches as cable cover across the cable in trenches complete all as specified and directed.
M&L for Plain cement concrete (PCC) type C2 1:3:6 using 40mm graded aggregate stone for making foundation of Pole/stay assembly complete all as specified and directed.
M&L for Plain cement concrete (PCC) type D2 1:4:8 using 40mm graded aggregate stone for making copings of Poles etc complete all as specified and directed.
M&L forPlain cement concrete (PCC) type B1 1:2:4 using 20mm graded aggregate stone for making copings of Poles etc complete all as specified and directed.
Shivom Projects Private limited
Global Enterprises
M/s Puja Construction Company
JYOTI ENTERPRISES
AMIT ASSOCIATES
M/S ANIL KUMAR
tarun construction co
MINHAS CONSTRUCTIONS
M/s Puja Construction Company
tarun construction co
AMIT ASSOCIATES
MINHAS CONSTRUCTIONS
Global Enterprises
M/S ANIL KUMAR
Shivom Projects Private limited
JYOTI ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .