Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC 01 KHUMRIYAL KUPWARA KHUMRIYAL KUPWARA KUPWARA JAMMU KASHMIR 193223 | KUPWARA | JAMMU AND KASHMIR | 193223 | L1 | Accepted-AOC L1 QUOTED | |
| 2 | L2₹11.7 L+₹1.7 L (17.4%)Rejected-AOC DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L2 | Rejected-AOC L2 QUOTED | |
| 3 | L3₹12.8 L+₹2.9 L (28.7%)Rejected-AOC KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L3 | Rejected-AOC L3 QUOTED | |
| 4 | L4₹12.9 L+₹3.0 L (29.6%)Rejected-AOC DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L4 | Rejected-AOC L4 QUOTED | |
| 5 | L5₹19.5 L+₹9.5 L (95.5%)Rejected-AOC | L5 | Rejected-AOC L5 QUOTED |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
4 Nov 2019, 6:00 pmClosed
GE AF SRINAGAR
GE AF SRINAGAR,AIR FORCE STATION,SRINAGAR-190007
REPAIR/ ROUTINE MAINTENANCE OF DG SETS INSTALLED AT VARIOUS LOCATIONS UNDER GE (AF) SRINAGAR
2019_MES_287732_1
GE(AF)-29/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SRINAGAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF SRINAGAR
₹30,000
Yes
15 Feb 2020
7 Oct 2019
5 Nov 2019
7 Oct 2019
4 Nov 2019
21 Oct 2019
7 Oct 2019 - 14 Oct 2019
Amount
Servicing of DG Set 625 KVA of any Make, checking entire system as per manufacturer's catalogue such as checking all parts for serviceeablility, taking down defective parts such as fuel filter assy, by pass filter assembly, lub oil filter assembly, air cleaner assy, flexible hose pipe, coolent etc and replacing the same with same size, make and capacity of parts, draining out the old used burnt engine oil from the sump cleaning all serviceable filters and oil sump with cleaning solution such as petrol/ diesel and refilling new engine oil upto required level and including testing to DG Set to entire satisfaction of Engr-in Charge. Note:- (i) Spare parts/ Engine oil/ check kit/ filter shall be measured and paid for saperately under respective items of BOQ (ii) Servicing shall be carried out by authoried dealer of manufacturer. (iii) Minimum 6 months gap/ 200 hrs of run whichever is earlier shall be considered for next service (iv) Repair Guarantee for replaced parts/servicing of DG Set shall be for six month/200 hrs from the date of service.
All as per item No 1 here-in-before but for DG set 500 KVA.
All as per item No 1 here-in-before but for DG set 400 KVA.
All as per item No 1 here-in-before but for DG set 250 KVA.
All as per item No 1 here-in-before but for DG set 200 KVA.
All as per item No 1 here-in-before but for DG set 160 KVA.
All as per item No 1 here-in-before but for DG set 140 KVA.
All as per item No 1 here-in-before but for DG set 125 KVA.
All as per item No 1 here-in-before but for DG set 100 KVA.
All as per item No 1 here-in-before but for DG set 82.5 KVA.
All as per item No 1 here-in-before but for DG set 75 KVA.
All as per item No 1 here-in-before but for DG set 62.5 KVA.
All as per item No 1 here-in-before but for DG set 55 KVA.
All as per item No 1 here-in-before but for DG set 50 KVA.
All as per item No 1 here-in-before but for DG set 30/31.25 KVA.
All as per item No 1 here-in-before but for DG set 15 KVA.
All as per item No 1 here-in-before but for DG set 10 KVA.
All as per item No 1 here-in-before but for DG set 7.5 KVA.
Supply only element lubricant oil filter suitable for 625 KVA DG set
Supply only element lubricant oil filter suitable for 500 KVA DG set
Supply only element lubricant oil filter suitable for 400 KVA DG set
Supply only element lubricant oil filter suitable for 250 KVA DG set
Supply only element lubricant oil filter suitable for 200 KVA DG set
Supply only element lubricant oil filter suitable for 160 KVA DG set
Supply only element lubricant oil filter suitable for 140 KVA DG set
Supply only element lubricant oil filter suitable for 125 KVA DG set
Supply only element lubricant oil filter suitable for 100 KVA DG set
Supply only element lubricant oil filter suitable for 82.5 KVA DG set
Supply only element lubricant oil filter suitable for 75 KVA DG set
Supply only element lubricant oil filter suitable for 62.5 KVA DG set
Supply only element lubricant oil filter suitable for 55 KVA DG set
Supply only element lubricant oil filter suitable for 50 KVA DG set
Supply only element lubricant oil filter suitable for 30/31.25 KVA DG set
Supply only element lubricant oil filter suitable for 15 KVA DG set
Supply only element lubricant oil filter suitable for 10 KVA DG set
Supply only element lubricant oil filter suitable for 7.5 KVA DG set
Supply only fuel filter element with set of 'O' Ring for 625 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 500 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 400 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 250 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 200 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 160 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 140 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 125 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 100 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 82.5 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 75 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 62.5 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 55 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 30/31.25 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 15 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 10 KVA DG set.
Supply only fuel filter element with set of 'O' Ring for 7.5 KVA DG set.
Supply only super bypass filter element suitable for 625 KVA DG set
Supply only super bypass filter element suitable for 500 KVA DG set
Supply only super bypass filter element suitable for 400 KVA DG set
Supply only super bypass filter element suitable for 250 KVA DG set
Supply only super bypass filter element suitable for 200 KVA DG set
Supply only super bypass filter element suitable for 160 KVA DG set
Supply only super bypass filter element suitable for 140 KVA DG set
Supply only super bypass filter element suitable for 125 KVA DG set
Supply only super bypass filter element suitable for 100 KVA DG set
Supply only super bypass filter element suitable for 82.5KVA DG set
Supply only super bypass filter element suitable for 75 KVA DG set
Supply only super bypass filter element suitable for 62.5 KVA DG set
Supply only super bypass filter element suitable for 55 KVA DG set
Supply only super bypass filter element suitable for 30/31.25 KVA DG set
Supply only super bypass filter element suitable for 15 KVA DG set
Supply only super bypass filter element suitable for 10 KVA DG set
Supply only super bypass filter element suitable for 7.5 KVA DG set
Supply only air filter element inner & outer suitable for 625 KVA DG set
Supply only air filter element inner & outer suitable for 500 KVA DG set
Supply only air filter element inner & outer suitable for 400 KVA DG set
Supply only air filter element inner & outer suitable for 250 KVA DG set
Supply only air filter element inner & outer suitable for 200 KVA DG set
Supply only air filter element inner & outer suitable for 160 KVA DG set
Supply only air filter element inner & outer suitable for 140 KVA DG set
Supply only air filter element inner & outer suitable for 125 KVA DG set
Supply only air filter element inner & outer suitable for 100 KVA DG set
Supply only air filter element inner & outer suitable for 82.5 KVA DG set
Supply only air filter element inner & outer suitable for 75 KVA DG set
Supply only air filter element inner & outer suitable for 62.5 KVA DG set
Supply only air filter element inner & outer suitable for 55 KVA DG set
Supply only air filter element inner & outer suitable for 50 KVA DG set
Supply only air filter element inner & outer suitable for 30/31.25 KVA DG set
Supply only air filter element inner & outer suitable for 15 KVA DG set
Supply only air filter element inner & outer suitable for 10 KVA DG set
Supply only air filter element inner & outer suitable for 7.5 KVA DG set
Supply only Gasket Set for 250 KVA DG set
Supply only Gasket Set suitable for 200 KVA DG set
Supply only Gasket Set suitable for 160 KVA DG set
Supply only Gasket Set suitable for 125 KVA DG set
Supply only Gasket Setsuitable for 100/82.5/75/62.5 KVA DG set
Supply only Gasket Set suitable for 55/50 KVA DG set
Supply only Gasket Set suitable for 30/31.25 KVA DG set
Supply only Gasket Set suitable for 15/10/7.5 KVA DG set
Calliberation of FIP complete after replacement of defective worn out parts for the capacity of DG Set 250 KVA complete all as specified and directed by Engineer-in-Charge (i) Bearing bush (ii) Plunger spring (iii) Pump element (iv) Delivery valve and spring (v) Banjo bolt and Benjo (vi) Sealing ring (vii) Oil seal (viii) Gasket (ix) Overflow valve etc
All as per item No 97 here-in-before but for DG set 200 KVA.
All as per item No 97 here-in-before but for DG set 160 KVA.
All as per item No 97 here-in-before but for DG set 140 KVA.
All as per item No 97 here-in-before but for DG set 125/100 KVA.
All as per item No 97 here-in-before but for DG set 82.5/75/62.5/55 KVA.
All as per item No 97 here-in-before but for DG set 31.25/30 KVA.
All as per item No 97 here-in-before but for DG set 15/10/7.5 KVA.
Supply and changing engine oil 15W/ 40, Make: Kirloskar / Castrol/ HP
Supply and fixing only pipe hose flexible with 2 Nos clamps of same size/ model/ capacity as per existing complete all as specified and as directed.
Supply and changing coolent all as specified and as directed. Make: Servo/ Shell/ Castrol/ HP
Supply and changing distilled water in for filling in batteries all as specified and as directed.
S&F in replacement automatic voltage regulator suitable for 100 to 250 KVA DG set including connections of AVR with panel with and including PVC insulated multistranded copper wires of suitablesize complete all as specified and as directed. Make: Kirloskar/ Crompton/ National/ Universal/ AE
S&F in replacement maintenance free lead acid battery 12 volts 180 AH complete all as specified and as directed. Make : Bosch/ Amaron/TATA GREEN
S&F in replacement maintenance free lead acid battery 12 volts 130 AH complete all as specified and as directed. Make : Bosch/ Amaron/TATA GREEN
S&F in replacement PVC transparent flexible pipe, superior quality, of 10mm dia approximate length 2 RM, tightening the same with two Nos of jublee clips on both ends,complete all as specified and as directed.
Servicing of self starter after disconnecting the same from DG sets, transporting to workshop, strip opening the same and replacing the defective parts/ winding including testing after repair/servicing and refixing in orginal position of capacity 7.5 KVA to 62.5 KVA complete all as specified and directed.
All as per item No 113 here-in-before but of capacity 70 KVA to 140 KVA
All as per item No 113 here-in-before but of capacity 160 KVA to 250 KVA
S&F in replacement off load change over switch, 63 Amp capacity, 3 phase, 4 pole, 415 volts, 50Hz, side handle operated, with and including MS sheet metal enclosure having advance neutral complete all as specified and as directed. Make:- C&S/ Havells/ Standard
All as per item No 116 here-in-before but 100 Amp
All as per item No 116 here-in-before but 200 Amp
All as per item No 116 here-in-before but 400 Amp
M&L for servicing/ cleaning of MS diesel tank of DG set 250 KVA/160KVA/125 KVA/ 50 KVA/31.25 KVA KVA by draining out the diesel from tank, cleaning the tank with soap water/ suitable solution and painting the external surface with one coat of synthetic enamel paint of existing colour including repalcement of drain valve, outlet pipe complete all as specified and as directed.
S&F in replacement, indicator lamp assembly (set of three) red, yellow, blue complete all as specified and as directed.
S&F in replacement, battery leads copper conductor single core of length 2 x 1.5m of suitable size for 12volt/ 24volt DC with brass terminal heavy duty complete all as specified and as directed.
Repair/Replacement of battery charger by replacing the worn out and defective items complete all as specified and as directed.
S&F in replacement, battery charger with auto cut off indicater suitable for 2x12 volts DC complete all as specified and as directed. Make : Sintrac/ Elak
Dismentling/ taking down complete radiator assembly of DG set 250 KVA and transporation to workshop for repair by :- (i) Opening the radiator assembly with brazing/ welding for repair/ services. (ii) Cleaning of all water tube with diluted solution of HCL & cleaning with water preasure & removing the sludge and dust from inside the tank by flushing out. (iii) Repair of fins by soldring/ brazing. (iv) Repair of bottom brass water tank by soldring/ brazing. (v) Repair of radiator hose assembly. (vi) Fixing the complete radiator assembly to its orignal position and testing complete
All as per item No 125 here-in-before but DG set 200 KVA.
All as per item No 125 here-in-before but DG set 160 KVA.
All as per item No 125 here-in-before but DG set 140 KVA.
All as per item No 125 here-in-before but DG set 125 KVA.
All as per item No 125 here-in-before but DG set 100 KVA.
All as per item No 125 here-in-before but DG set 82.5/70/62.5/55 KVA.
All as per item No 125 here-in-before but DG set 31.25/30/15/10/7.5 KVA.
S&F in replacement, water temp gauge circular dial complete all as specified and as directed. Make : AE/ VIDEO
S&F in replacement, fan belt suitable for 7.5/10/15 KVA DG set complete all as specified and as directed. Make : - Dollup/ Fenner
All as per item No 134 here-in-before but suitable for 30 KVA DG set complete all as specified and as directed.
All as per item No 134 here-in-before but suitable for 55/62.5/70 KVA DG set complete all as specified and as directed.
All as per item No 134 here-in-before but suitable for 82.5/100 KVA DG set complete all as specified and as directed.
All as per item No 134 here-in-before but suitable for 125 KVA DG set complete all as specified and as directed.
All as per item No 134 here-in-before but suitable for 140 KVA DG set complete all as specified and as directed.
All as per item No 134 here-in-before but suitable for 160 KVA DG set complete all as specified and as directed.
All as per item No 134 here-in-before but suitable for 200 KVA DG set complete all as specified and as directed.
All as per item No 134 here-in-before but suitable for 250 KVA DG set complete all as specified and as directed.
Disconnection of electric connection from DG set control penal, dressing of cable including replacement of burnt out aluminium lugs and fixing with new lugs, nuts bolt complete all as specified and as directed.
Supply and Fixing in replacement of Self Starter of Capacity 24 Volt suitable for Kirloskar /Cummins Dg set all as specified and directed by Engineer in Charge.
Supply and Fixing in replacement of Self Starter of Capacity 12 Volt suitable for Kirloskar /Cummins Dg set all as specified and directed by Engineer in Charge.
M&L in repairs to AMF Panel/Control panel of DG Set by replacing following parts and commissioning and testing the panel complete all as specified and directed by Engineer-in-Charge
Contactor 3 pole 400 Amp Capacity Make: L & T, Siemens , Schiender
Contactor 3 pole 325 Amp Capacity Make: L & T, Siemens , Schiender
Contactor 3 pole 225 Amp Capacity Make: L & T, Siemens , Schiender
Contactor 3 pole 70 Amp Capacity Make: L & T, Siemens , Schiender
Contactor 3 pole 32 Amp Capacity Make: L & T, Siemens , Schiender
Relay 12 volt 8 Pin
Relay 24 Volt 8 Pin
On Relay Eloctronic Timer complete all as specified and directed by Engineer-in-Charge.
Line voltage Monitoring Relay 3 Phase 415 Volt complete all as specified and directed by Engineer-in-Charge.
Energy Starting Relay 12 Volt complete all as specified and directed by Engineer-in-Charge.
Repair/Replacement of start/Stop Switch complete all as specified and directed by Engineer-in-Charge.
Replacement of Engine Control Unit complete all as specified and directed by Engineer-in-Charge.
Replacement of solenoid switch complete all as specified and directed by Engineer-in-Charge.
Replacement of Turbo charger kit complete all as specified and directed by Engineer-in-Charge.
Repair/Replacement of worn out/defective part of Dynamo kit complete all as specified and directed by Engineer-in-Charge.
Opening the silencer from the Gen Set shift to market for repair , descaling the fins with caustic soda , cleaing and washing the same including repairing of broken parts by bronzing /welding of cap 125 to 250 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Note for all above items: (i)Two Mechanic for the repair of DG set shall be deployed by the contractor during working hours. The each DG set to be repaired within 24 hours, failing to which penalty of Rs 1000/- will be imposed per day till the each DG set is repaired. (ii) All repair work shall be carried out only by authorised person qualified in the relevant trade (iii) Make of components replacement if not specifically mentioned in the relevant item same shall be of the existing make.
M/S ASHRAF CONSTRUCTIONS
M/S RATHER CONSTRUCTION CO
M/s Jaipal Associates
M/S A.R.TANTARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .