GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
Special repair to certain bldgs and Provn of one UPS of AGE E/M and AGE B/R Dett-B under GE 862 EWS
2023_MES_574007_1
GER-72/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Class D a(i)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹94,800
Yes
20 Feb 2023
9 Jan 2023
8 Feb 2023
9 Jan 2023
6 Feb 2023
24 Jan 2023
Amount
Sch 'A' Part-I (B/R works) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directe
Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
M&L for brick work using old size bricks sub class 'B', straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4, complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregates as in sub base of floors and mass concrete, complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (premium quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M&L for vitrified tiles light shade (premium quality) 10 mm thick (square/ rectangular) polished, area of each tiles n exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 350x250x7mm / 450x350x7mm thick, (premium quality) on vertical surface of wall such as dado, skirting, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick screed bed in cement mortar 1:3, complete all as specified and as directed.
M&L for Machine cut kota stone slab(mirror polished) flooring 18-20mm thick as in floors and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 20 mm thick in cement mortar (1:4) complete all as specified and directed.
Description all as per srl item No. 09 above but skirting and dado etc
M&L for 75mm thick plain cement concrete, type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) as in plinth protection, laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight), complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4, type B-1 (20mm graded crushed stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like after demolition of cement concrete etc, complete all as specified and directed
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L formwork to soffits of suspended slabs such as roof slabs, landings and similar work, n exc 200mm thick (Horizontal and sloping) for rough finished surface of concrete, complete all as specified and directed.
M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide,for rough finished surfaces of concrete, complete all as specified and directed.
Taking down cement or cement lime plaster, any description on any walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on other than fair faces of brick work, finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening, complete all as specified and directed.
Complete removal of existing treatment of old plastered surface of walls, preparing surface including washing rubbing down and stopping of distemper surface and applying two coats of distemper oil emulsion over one coat of chalk whitening, complete all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work, finished the surface even and smooth without using extra cement, complete all as specified and directed.
Complete removal of existing treatment of wall/roof surfaces including cornices and chajjas etc and applying two coats of exterior weather proof paint in camouflage of two and more colours pattern over and including a coat of primer including 1mm thik wall care putty, complete all as specified and directed by Garrison Engineers.
M&L for prepartion of old decorated plastered surface in ceiling etc by brooming down with steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy oil and greasy spots and applying one coat of white wash on ceiling, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 Sqm and not exceeding 4.0 Sqm each removing form site, complete all as specified and directed.
Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing from site, complete all as specified and directed.
S&F for pressed steel door frame of size 125x60 mm with one or more rebates incl necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-0 using 20mm graded crushed stone agregate complete all as specified and directed.
S&F for factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F for factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
S& F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvinsed wire staples , complete all as specified and directed.
S& F in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks, or galvinsed wire staples , complete all as specified and directed.
S&F for solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square, complete all as specified and shown on drwaing in SSR Part-II (2020) directed.
S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & shown in drawing mentioned in SSR Part-II 2020, complete all as specified and directed.
S&F for 4 mm thick sheet glass ordinary quality and glazing with oil putty / wooden beads in squares n . exc 0.50 sqm in each pane complete after hacking out old broken glass all as specified and directed.
M&L for preparation of new wooden surfaces of any description exc 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description exc 10 cm in width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for preparation of old steel surfaces of any description exc 10 cm in width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
M&L for precast cement concrete 1:2:4, type B-0 (12.5mm grade crushed stone aggreagte) as in embedding hold fasts as directed including necessary form work as reuired, complete all as specified and directed.
S&F for 100mm long mild steel butt hinges medium weight colled rolled (ISI marked), complete all as specified and directed.
M&L for 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked), complete all as specified and directed.
M&L for 125 mm long extruded aluminium alloy handles size fabricated type anodised (ISI marked), complete all as specified and directed.
M&L for 300mm long (lenth of bolt) aluminium alloy, anodised, sliding door bolt with hasp, stapl (bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolt of extruced sections or cast aluminium alloy anodised (ISI marked) complete all as specified and directed.
S&F 140mm long floor door stopper of aluminium alloy anodised body and tongue with hard drawn steel spring, complete all as specified.
Taking down old unserviceable GI pipe of 15 /20mm bore with all fittings etc, complete all as specified and directed.
S&F for 15 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
S&F for 20 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors etc, complete all as specified and directed.
Fixing only 15 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors, complete all as specified and directed.
Fixing only 20 mm bore galvanised iron GI tubing medium grade with all fittings such as bends, socket, tee, elbow, union, nipple, short pieces and fixed to walls, ceilings or laid in floors, complete all as specified and directed.
S&F in repair 15mm bore bib tap cast copper alloy, chromium plated, fancy type, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule, complete all as specified and directed.
S&F in repair 15mm bore stop valve (angle valve), cast copper alloy chromium plated screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete as in repair all as specified and directed.
M&L in repair 15mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes after taking down of valve, complete all as specified and directed.
M&L in repair 20mm bore gun metal, gate / globe valve with iron wheel head screwed on both sides for iron pipes after taking down of valve, complete all as specified and directed.
S&F for in repair sinks with draining board made out of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
S&F in repair 32mm dia waste coupling PTMT (half or full threaded), minium weight 60 gms) fixed to stainless steel sinks, complete all as specified and directed.
S&F in repair for chromium plated tubular towel rail 20 mm dia "D" type 60 cm long between flange aluminium anodised including one pair of brass chromium plated brackets, complete all as specifed and directed.
S&F in repair for 125 mm dia PTMT grating doom with waste hole for waste pipe (minium weight 40 grm), complete all as specified and directed.
S&F in repair for PVC connection 15 mm x 600 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore, complete all as specified and directed.
S&F in repair 20 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair vitreous China wash basin, white, flat back, size 550x 400mm including waste coupling waste pipe and brackests, complete all as specified and directed.
S&F for 15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, brass chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
S&F in repair for vitreous China water closet (squatt pan) Orrisa pattern 580x440 mm size pan, white, with front or back inlet with integral 'foot rests including provn of lime concrete bedding including connections to flushing cistern with flush pipe, complete all as specified and directed.
S&F in repair for 10 ltrs capacity (PVC), valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, complete all as specified and directed.
S&F in repair for 500 ltr capacity three layer (ISI marked) rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including 20mm bore ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floor or tranches as in weep hole, complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) bend any radius, complete all as specifed and directed by Engr-in-Charge.
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to wall or in floor or trenches as in weep hole, complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) bend any radius, complete all as specifed and directed by Engr-in-Charge.
S&F in repair 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement and connecting to waste pipe, complete all as specifed and directed.
S&F for steel ventilators with top hung shutter including hinges, steel peg stay complete all as specified and directed.
S&F in repair for stainless steel curtain rod of 20mm dia, complete all as specified and directed.
S&F for bracket and finials of stainless steel of fancy type (colour and design approved by GE) curtain rod stainless steel 20mm dia including fixing to walls with MS full screws (including fixing of wooden pieces of required size of walls) complete as in repair all as specified and directed .
M&L for rendering 10 mm thick on concrete surface of ceiling in cement mortar 1:3 other than fair faces finished the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for complete removal of existing water proofing treatment over RCC roof, projections of any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with wire brush including removing debris from the site and depositing in low lying area where directed and providing following :- (a) Rendering 10mm thick in cement mortar 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 2% by weight of cement. (b) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (c) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (d) Provide polymeric water proofing membrane ISI marked laid with overlaps, bonded with hot blown bitumen, and laid by torch application method, end overlaps shall not be less than 150mm and side lap 75mm. Polymeric water proofing membrane should be five layered with centre core as 90 micron high molecular high density polyethylene film, min weight 3 Kg per sqm. APP membrane shall laid acorss the slop from lowest line of sloping roof towards ridge. (e) Over the APP membrane, apply a coat of semi hot blown 85/25 penetration grade bitumen confirming to IS-702 @ 1.20 Kg/ sqm and blinded with fine sand in dry condition @ 0.50 Kg / Sqm dusted over the bitumen coat Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (ii) Ponding test shall be conducted for 72 hrs as directed.
M&L for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Gde E-165 complete all as specified and directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth in in any type of soil, for foundation, etc, or for shafts, wells, drain pipes n.exc 10 Sqm on plan and getting out, complete, all as specified and directed.
Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick ,complete all as specified and as directed.
Removing excavated material ,not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting poin, complete all as specified and directed.
Demolition and breaking up existing sewage (SGSW / AC pipes) and the like, 150 mm bore set in cement mortar and removing demolished material to a distance exc 500m and n exc 1000m, complete all as specified and directed by Engr-in- Charge.
M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi-tred/stopped ends etc, complete all as specified and directed.
M&L for 150 mm internal dia Salt-Glazed stone ware drain pipes grade 'A' laid in trenches over concrete bedding jointed in cement mortar 1:1 and tested ,complete all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2 ,using 40 mm graded stone aggregate, as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore SGSW pipe, complete all as specified and directed.
M&L for plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete complete all as specified and directed.
M&L for plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in apex stone, coping, benching, hold fasts, manhole covers, bed block, surface channel and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work ,complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed.
S&F for pressed steel door frame of size 105x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-0 using 12.5mm graded stone agregate complete all as specified and directed.
S&F for box type steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for box type steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S&F in repair for viterous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, (excluding fixing bolts, flushing cistern) and inlcuding flush pipe set of CP jet with PVC pipe of superior quality complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of chalk whitening, complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of distemper oil emulsion over a coat of chalk whitening, complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided including existing water proofing treatment, complete all as specified and directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc.) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications, complete all as specified and directed.
M&L for point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVC conduit medium grade of 25mm width complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making good the diturbed surfaces compete all as specified and directed. (Note:- Three run of copper conductor of required size and one run of casing capping measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth)
Description all as per Serial item No 92 above but for one 3 pin 6 Amp socket outlet on independent board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 92 above but for one 3 pin 6 Amp socket outlet on same board controlled by one 6 amp switch, complete all as specified and directed.
Description all as per Serial item No 92 above but for one bell point controlled by one bell push, complete all as specified and directed.
Description all as per Serial item No 92 above but for one light point controlled by 2 way switches, complete all as specified and directed.
Description all as per Serial item No 92 above but for one 3 pin 16 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistraind copper cable with 2.5 sqmm single core multistraind FRLS copper cable as earthling lead complete all as specified and directed.
M&L for switch piano, flush type single pole, one way 6 Amp, 240 volts, complete all as specified and directed.
M&L for switch piano, flush type single pole, two way 6 Amp, 240 volts complete all as specified and directed.
S&F for bell push flush type single pole one way 6 amps 240 volts complete all as specified and directed.
S&F for switch socket combination 2 in 1, 5 pin, 6 amp flush type complete all as specified and directed.
S&F for switch socket combination 2 in 1, 5 pin, 16 amp flush type complete all as specified and directed.
M&L for switch outlet combination 2 in 1, 3 pin, 5 Amp 230 volts flush type complete all as specified and directed.
M&L for ceiling fan regulator elctronic, flush type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed.
S&F for call bell AC, 230 volts, single pole, ding-dong sound type complete all as specified and directed.
S&F for ceiling rose 3 phase/PVC/polycarbonate isolated body surface bakelite 2 to 3 terminals complete all as specified and directed.
Taking down, servicing and refix of exhaust fan including painting complete, in situ with synthetic enamel paint, including copper winding of sweep 250mm, completed all as specified and directed.
Taking down, servicing and refix of ceiling fan, sealing cable end and painting of ciling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc, completed all as specified and directed.
M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed.
M&L for LED Tube light fitting, complete with 1x 10 watts 2 feet, 220V, AC decorative box type with driver, holder in and including LED tube light connection complete prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height complete as in repair all as specified and directed.
S&F for environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10 watt 6000 K inbuilt LED luminaire comprising of high brightness LEDs, IP54 protection including connecting electrically using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete as in repair all as specified and directed.
S&F in repair LED security light fitting 35 watts, 230 volts, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resisitant including thermal managament in multiple optics complete with IP 65 /66 with all accessories and necessary fixing arrangement on wall at any height including three core 0.5 sqmm copper cable from connector to fitting and after taking down old unserviceable light fittings of any type complete as in repeir all as specified and directed
S&F for MCB distribution board TPN 4 way, double door 415 volts duly painted with epoxy based powder coated painting suitable for mounting MCB TP/FP as incomer of rating upto 63 Amps, FP and MCB SP/TP as outgoings complete with 200 Amps rated busbar, neutral bar, earth bar connecting cable links with top and bottom removable gand plate with IP 42 protection including removing old unserviceable item complete as in repairs all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as in repair all as specified and directed. (Note:- MCBs will be measured separately.)
M&L for MCB SP 240 volts any rating from 6 to 32 amps, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB SPN, 240 volts of rating 63 Apms, 'C' series/curve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 4 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 4 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable sub main wiring items complete all as specified and directed. (Note : - 02 run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable and 01 run of PVC casing and caping shall be measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth).
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2009 including testing on completion complete all as specified. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 250mm x 150mm x 40mm, complete all as specified and as directed.
M&L in repair for 50mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for protection, complete all as specified and directed.
S&F for decorative LED Bollard light with opal diffuers and aluminium reflector outdoor type LED Bollard light 8W, IP 65 lihgt including all accessories and connecting materials such as clamps, brackets, nut bolts reducer etc with base PCC 1:2:4 fixed on wall/floor and making electrical connection with copper cable complete as in repair all as specified and directed.
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 6 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 70 sqmm 3.5 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
Supply, insallation, testing and commissioning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50 Hz Indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation, factory fabricated made out of 3.2mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The panel shall have front and rear opening, locking arrangement, bus bar chamber and switch gear compartment, hinged door with rubber gasket, botton cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, aluminium bus bar duly covered with heat shrink sleeves colour coded duly fixed on DMC/SMC insulators, aluminium strip connection from bus bar to outgoing MCCBs and copper conductor cable of adequte size of MCBs, housed in a separate bus bar chamber and control wiring adequate size and length, outgoing MCCBs shall have extended bus bar links and panel mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in foundation design subject to approval of GE as per as site requirement. The minimum depth height width of panel is 450x1200x1200 mm respectively, minimum claerance from ground level is 450 mm including removing old unserviceable item complete all as specified and directed and comprising of following :- (a) MCCB, 160 Amps, FP, 35 KA, 415 volts, 50 Hz - 01 No (Adjustable type, as thermal magnetic release as in coming) (b) MCCB, 100 Amps, FP, 16 KA, 415 volts, 50 Hz - 03 Nos ((Adjustable type, as thermal magnetic release) (c) MCCB, 63 Amps, FP, 10 KA, 415 volts, 50 Hz - 02 Nos ((Adjustable type, as thermal magnetic release) (d) MCB, 40 Amps, DP, 10KA, 415 volts, 50 Hz, "C" Series - 1 Nos (e) Digital voltmeter (0-500V) with CTs and VSS-01 set, Digital Ammeter (0-100A), with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 400 Amps rating - 01 set (Note: LT panel drawing to be approved by GE duly recommended by Engr-in-Charge).
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m deep below normal ground level connected to and including 25X4mm thick galvanised iron strip by means of bolts, nuts, checknuts and washers of galvanised iron or steel all as specified in electrical plate No 3 of SSR (2010) part-I including 40mm bore GI pipe light grade for protection of earth strip and PCC 1:2:4 type B-1 as in pit, Precast RCC earth pit cover 8 cm thick reinforced with 8mm dia TMT bars @150mmc/c and two handles, excavation and earth work in any type of soil and alternate layers of charcoal, common salt and 20mm bore galvanised medium grade steel tubing for watering with one end fixed with cast iron funnel and wire mesh and testing on completion complete all as specified and directed. (Note:-Earth strip and protection pipe upto board is included in the rate quoted)
Supply, install, test and commissiong on-line UPS (Uninterrupltible Power supply ) of 5.5 KVA having system with input voltage 160 to 260 volts, single phase and output voltage 230 volts single phase with automatic static switch and manual bypass arrangement including SMF battery bank for one hour back up at full load having IGBT sine weighted PWM technology, forced cooling type internally prewired complete with all accessoreis and including digital type multifunction meter for battery ON/ Off switch, manual bypass switch for servicing purpose static switch for automatic transfer to mains in case of inverter failure, LED indicating lamps for mains and for output U,V,W. The UPS shall have protectio against output under/over voltage over load/shoart circuit, input over/under voltage, input phase fail/reversal, low battery over temperture, IGBT fuse protection, and the system shall be housed in MS sheet steel cabinet having wheels with IP-21 protection and duly painted with powder coated paint. The UPS shall be an upright, free standing with removable side covers hinge mounting front and back doors. AC filter chokes & transformers are mounted on the bottom plate of the cabinet. Cable entry holes shall be provisioned at bottom side of the cabinet. Battery stand alongwith necessary battery interconnection by providing copper cables. The UPS shall meet the techncial parameters such as input voltage 230 volts (+/-) 1% : Frequency 50 HZ (+/-) 6%. Power factor 0.8 lag to unity at output, voltage output 230 voltas phase to neutral, voltage adjustment (+/-) 10% of normal voltage, Regulation (+/-) 1% for 10 % to 100 % load variation area and (+/-) 1% for (+/-) 15 % input supply variation, voltage balance (+/-) 2% for balanced load and (+/-) 3% for 50 % unbalanced load , over load at 125 % for 5 minutes and 150 % for 10 second complete all as specified and directed.
Supply,laying, jointing and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 sqmm 2 core laid in trenches, ducts, pipes, on poles and connection with necessary cables lugs, glands nut bolts complete after taking down old unserviceable cable all as specified and directed. (Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).
M&L for MCB SPN, 240 volts rating of 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L for MCB two way centre off change over switch, DP 240 volts of rating from 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in repair for MCCB, FP, 415 volts, 63 Amp with ruptring capacity 25 KA, adjustable type, 50 Hz, complete all as specified and directed.
M/s Anil Engineers & Builders
M/S BADRI NATH GUPTA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .