| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹48.6 L+₹1.3 L (2.85%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹49.0 L+₹1.8 L (3.73%)Rejected-Finance 1476 SARASWATI COLONY CHERITAL JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹49.8 L+₹2.5 L (5.37%)Rejected-Finance 1257 SCHEME NO 5 NEAR HB COLLEGE VIJAY NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹60.0 L+₹12.7 L (27.0%)Rejected-Finance 712 GORAKHPUR JABALPUR 482001 MP | JABALPUR | MADHYA PRADESH | 482001 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
13 Dec 2021, 6:00 pmClosed
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR /MAINT OF LIGHT FITTINGS , FIXTURE ,SUBMAIN WIRING AND OTHER RELATED MISC WORK UNDER GE (W) JABALPUR
2021_MES_488274_1
8390/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹99,000
18 Dec 2021
15 Nov 2021
15 Dec 2021
15 Nov 2021
13 Dec 2021
29 Nov 2021
16 Nov 2021 - 26 Nov 2021
Amount
Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed by Engineer-in-Charge.
S&F in repairs Sub main wiring with two single core PVC Insulated cable two run of size 4 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 2.5 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete etc all as specified & directed. Note : - Two run of 4 Sqmm & one run of 2.5 Sqmm cable shall be measured as one unit run.
S&F in repairs Sub main wiring with two single core PVC Insulated cable two run of size 6.0 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 25 mm dia with all conduit accessories and one run of 4.0 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire complete etc all as specified and directed. Note : - Two run of 6 Sqmm & one run of 4 Sqmm cable shall be measured as one unit run.
S&F in repairs Sub main wiring with two single core PVC Insulated cable two run of size 2.5 Sqmm multi-strand copper conductor FRLS cable 1100 volts grade drawing in and including PVC conduit, medium grade not less than 20 mm dia with all conduit accessories and one run of 1.5 Sqmm multi-strand copper conductor FRLS cable as continuous earth wire including making good disturbed surface to match existing complete etc all as specified & directed. Note : - Two run of 2.5 Sqmm & one run of 1.5 Sqmm cable shall be measured as one unit run.
Material & Labour for point wiring with three layer PVC Insulated 1.5 Sqmm multi-strand copper conductor FRLS cable 1100 Volts grade drawn into and concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-strand copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar 1:3 to match with the existing surfaces complete all as specified & directed by Engineer-in-charge.
(a) One light/ Fan / Bell Point controlled by one switch.
(b) One socket point 5 Amp controlled by one switch on same board.
(c) One socket point 5 Amp controlled by one switch on Independent board.
(d) One light point controlled by two way switch.
Ditto all as per above items but with 1100 Volts grade copper stranded conductor FRLS cable of size 2.5 Sqmm main & with 1.5 Sqmm earth multi-strand copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
S&F call bell ding dong sound type suitable for AC 240 volt single pole complete all as specified & directed. Make anchor
S&F switch bell push flush type suitable for 5 Amp 230 Volt of polycarbonate body complete all as specified & directed.
S&F Ceiling rose surface type 60x30 mm three terminals of polycarbonate body complete all as specified & directed.
Supply & Fixing in repairs Smart bright Batten Series, LED luminaire using LEDs 22 watt with diffuser, 2400 lumen which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded polycarbonate housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification
Supply & Fixing in repairs Smart bright Batten Series, LED luminaire using LEDs 20 watt with diffuser 2200 Lumens , which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded polycarbonate housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets (supplied along with The Luminaire has been tested as per Standard Specification IEC 60598-2-1 / IS: 10322(Parts/Secl), report has established conformity of the product(s) to the requirements of the Standard/Specification
S & F in reparis LED Mirror light fitting 2 ft T5 9/10 watt aluminium housing complete with fixing arrangements on wall all as specified and directed.
S&F in replacement of decorative wall light fitting made up of Polycarbonate ,Cylindrical shape ,with LED lamp 9 Watt complete with fixing arrangements on wall all as specified and directed. Make: CITY 1 OF HAVELLS or equivalent in Bajaj/Philips
S&F in replacement Bulk head endura LED light fitting complete 10 watt LED and making necessary electric connection to ceiling rose with copper conductor of suitable size and accessories & length complete all as specified & directed.
S&F in reparis LED light fitting square 600x600mm CM Not less than 36 watt along with fixture Surface / Recessed /Pendent mounting LED luminaries with diffuser channel Luminaires ers, connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge.
Supply & fixing in repair LED light down lighter by recess mounted 8 to 12 watt as required at site with fixing arrangemnts complete on ceiling all as specified & directed .
Supply & fixing in repair LED light down lighter by surface mounted 15 watt as required at site with fixing arrangemnts complete on ceiling all as specified & directed .
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make : Legrand /Schneider / Semens
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 4 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make : Legrand /Schneider / Semens
S&F in replacement sheet metal enclosure MCB DB double door [Acrylic], Triple pole and neutral, 440 volts, 4 way with 200 Amp, 10 KA breaking capacity rated copper bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.Make : Legrand /Schneider / Semens
S&F in replacement MCB Triple Pole and Neutral 63 Amps,10KA breaking capacity complete all as specified & directed.Make: Legrand /Schneider/ Semens
S&F in replacement MCB Single Pole and Neutral 240Volt, 40 Amps,10KA breaking capacity complete all as specified & directed.Make: Legrand /Schneider/ Semens
S&F in replacement MCB Single Pole 240Volt, 6 to 32Amps,10KA breaking capacity complete all as specified & directed.Make:Legrand /Schneider/ HPL
S&F in replacement 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathed of PVC tape and over all PVC sheathed in service connection, one twin core 10 Sqmm stranded aluminium conductor cable flat or circular complete all as specified and directed.
Supply & fix in replacement of LED Security Light Luminaire 25 watt 6000K with .high power LED cool white,CRI 75,+/- 5% supply voltage 220/240/50 Hz, light engine driver base.pole adapter,powder coated pressure die cast aluminium with heat resistant toughened glass IP 66 Rating with lens type,GI pipe 40 mm dia medium Grade not less than with 1.2 m.long in any shape with 2 nos of pole fitting clamps made out of MS flat , nuts and bolts and painting with aluminium paint. complete all as specified and as directed..Make: Surya cat part no :Lexon SLE UL 25W IP66 or HAVELLS Cat part no LHDAUU7PA7J025 VLUMINA or Equ in philips,luker.
Supply & Fixing in repair single pole and netural sheet metal enclosure with a two pin and earth plug and socket complete with 01 number single pole MCB 20 Amps complete all as specified & directed. Make :- Legrand/ Havells/ ANCHOR
Supply & Fixing in replacement switch piano flush button type single pole one way 5 Amps (duly marked for light / fan etc on the body of switch) of polycarbonate complete all as specified & directed.
Supply & Fixing in replacement socket outlet 2 in 1, 5 Pin 5 Amp flush type of polycarbonate body complete all as specified & directed.
Supply & Fixing in replacement Switch socket combination 2 in 1, 3 pin / 5 Amp and 15 Amps flush type universal of polycabonate body complete all as specified & directed.
Supply & Fixing in replacement Ceiling Fan regulator electronic type 450 Watt capacity of ploycarbonate body ISI marked complete all as specified & directed.
S&F in replacement PVC conduit 25mm medium gradeas required at site for passing through submains complete with all fittings such as tee, bends,elbow, saddle etc and making good the disturbed surfaces etc (Cutting , chasing,finishing shall be included in this Item complete all as specified.
S&F in replacement of modular switch 6-10 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F in replacement of modular switch 16 Amps one module 230 volts AC as per existing model/make complete all as specified and as directed
S&F in replacement of modular socket, 6A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed.
S&F in replacement of modular socket, 6/16A -2/3 pin combined 2 module, 230 volts AC as per existing model/make complete all as specified and as directed .
S&F in replacement modular fan regulator, 2 Module 4 step 180w heavy duty 230 volts as per existing model/make complete all as specified and as directed.
S&F in replacement modular bell push switch piano, flush type, 6 Amps complete all as specified and as directed.
S&F in repairs LED Bulb 230V AC 9 watt cool day light 6500K having maximum height 1020mm heavy duty complere all as specified and directed by Engineer-in -charge.
Supply & Fixing in repairs RCBO four Pole 240Volt, 63 Amp,300 MA protection for earth over load and short circuit complete all as specified & directed. Make : Legrand 411379 / Siemens / GE
Supply & fixing in replacement of integral post top lantern complete with black ABC plastic spigot, spun aluminium funnel shape with clear acrylic cover light opening on canopy with baffles and accessories and suitable for LED min 15Watt lamp complete all as specified and directed . Havells cat part No RUBYMINIPT15WLED757PSYMTOPC or equivalent make of Bajaj/C&S/Suriya
S&F in replacement of sheet steel enclouser distribution boards, double door factory made TPN Vertical 4 way 3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulated copper jumpers of suitable size from the MCCB to the out going circuits one incoming MCCB 100 amps and MCB TP 63 A -02 Nos,MCB SP -04 Nos circuits comprising of 3 phase 4 wire of suitable rating all as specified and directed.Legrand /Schneider M9/ Semens
Supply & fixing electronic energy meter tamper proof design digital technology of SINGLE phase 2 wire 1 x 240 volts 50 HZ 0.4% basic current for direct connected meter and 0.2% of basic current for CT operated meter with LCD display class-1 accuracy as per IS : 13779 Microprocessor based single phase energy meter of 10--60 Amp / 5 Amp CT operated with CT with optical communication port complete with all accessories complete all as specified & directed at site. Make :SARAL OF SECURE OR equivalent in,HPL Havells or as approved by GE.
Supply & fixing electronic energy meter tamper proof design digital technology of THREE phase 4 wire 3 x 240 volts 50 HZ 0.4% basic current for direct connected meter and 0.2% of basic current for CT operated meter with LCD display class-1 accuracy as per IS : 13779 Microprocessor based single phase energy meter of 10--60 Amp / 5 Amp CT operated with CT with optical communication port complete with all accessories complete all as specified & directed at site. Make :Sprint 350 of SECURE OR equivalent in,HPL Havells or as approved by GE.
S&F in repairs Recess/ Surface mounted IP20 PIR movement detector with a built-in switch for lighting. It should be able to take lighting load of 6A. It should control office area of around 20sq.mtr for small movement and 50sq.mtr for large movements. It should have smart daylight sensing for additional savings through daylight override and daylight switching. It should have timer knob (1 to 30 min setting) and light detection knob (100 to 1500 Lux setting) on the bottom face for ease of controlling after installation as well. Smart timer should extend the delay time by 10 mins if movement is detected shortly after switch-off. It should have a retractable shield. Operating temperature +5 to +50 Degree Celsius. It should have EMC compliance IEC (EN) 60669-2-1, Immunity IEC (EN) 61547 And Immunity IEC (EN) 55015 & IEC (EN) 55022, Class B. Max power consumption of 1.2W at standby. Make Philips LRM1071 or Bajaj/ Crompton
Material & Labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete. Note:- If earth resistance of earthing is not found satisfactory it will be redone by the contractor without any extra cost to Govt.
Supply & Fixing in repairs RCBO double Pole 240Volt, 32 Amp,30 MA protection for earth over load and short circuit complete all as specified & directed. Make : Legrand 411395/ Siemens / GE
M/s Ajayshwar Singh Rana
RAINA SALES AND SERVICES
Sachdeva Enterprises
RAVI TEJ BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .