Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 114 BASEMENT MALL ROAD KINGSWAYS CAMP NORTH WEST DELHI DELHI 110009 | NORTH | DELHI | 110009 | Admitted-Finance |
| 2 | Admitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | Admitted-Finance |
| 3 | Admitted-Finance 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹65,787
Closing Date
18 Mar 2021, 2:00 pmClosed
Director, DSCI
Delhi State Cancer Institute Dilshad Garden Delhi
Replacement of old defective Cooling Tower and Condenser pipe line, Air Handling unit and other associated low side work for the existing 3 x 390 TR HVAC plant at Delhi State Cancer Institute (East), Dilshad Garden, Delhi
2021_DSCI_199646_1
07/EE(E)/DSCI/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Delhi State Cancer Institute Dilshad Garden Delhi
As per terms and condition of eligibility creteria
10 documents required · 10 mandatory
₹0
₹65,787
24 Mar 2021
5 Feb 2021
18 Mar 2021
5 Feb 2021
18 Mar 2021
5 Feb 2021
Amount
CONDENSER WATER PIPE Replacement/Supplying, fixing, testing and commissioning of condenser water Pipe of following sizes of MS 'C' class along with necessary clamps, vibration isolators and fittings such as bends, tees etc. but excluding valves, strainers, gauges etc. adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc. as per specification and as required complete in all respect. Note:-The Pipes size 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel Pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. And from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
400 mm dia.
250 mm dia.
200 mm dia
Providing, laying and fixing following dia. G.I. pipe (medium Class) on surface with clamps/brackets and G.I. fittings etc. as required.
100 mm dia
50 mm dia.
VALVES WITHOUT INSULATION Replacement/Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per Specifications. BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified.
400 mm dia.
250 mm dia
200 mm dia.
50 mm dia.
INSULATED CHILLED WATER PIPING (Nitrile rubber insulation) Replacement/Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastomeric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive Complete including repairing of damage to building etc. as per Specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel Pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above.
200 mm dia.
65 mm dia
65 mm dia
INSULATED VALVES Replacement/Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately Supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot eater circulation as specified.
200 mm dia.
65 mm dia.
50 mm dia.
Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as Specified.
200 mm dia.
NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for Chilled / hot water circulation including insulation as specified
200 mm dia
Cooling Tower Replacement of defective /unserviceable existing cooling tower with new SITC of FRP cooling tower of 600 TR (22,70,000K cal/hr ) heat reject capacity FRP water basin ,PVC filling with louvers and drift eliminators complete with basin either fitted with spray Nozzle or having self rotating sprinkler ,statically and dynamically balance axial flow type fan –direct driven through reduction grea box with TEFC induction motor, suction screen make up quick fill arrangement overflow and drain connection with necessary valves (excluding valves and pipes etc.) and inspection ladder made out of steel ,necessary arrangement for cooling tower interior ,cement concrete foundation ,steel /masonry supporting structure ,ant vibration with electrical connection i/c dismantling etc. complete as required with flowing technical specification of cooling tower. i) Hot water Temperature 97.50 degree F ii) Cold water temperature 90.00 degree F iii)Wet Blub Temperature 83.00 degree F iv) Water flow rate 2400.00USGPM v) Wet bulb approach 7 degree F vi) Motor HP 12.5 HP x 02 nos. vii) RPM 570 viii)Type Induction type ,Squirrel cage (IP 55) TEAO
Replacement/Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminum finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for variable frequency drive applications, drain Connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dials type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following.
Supply, installation, testing and commissioning of new AHU coils in existing AHU size as per the measurement ,with given specification(Tube, Header material copper, including re-fixing of existing valves, coil casting GI, fins, material- plain Aluminum).
AHU capacity 5000 CFM
Supply and installation of industrial type [pressure gauges with gun metal /brass valves.
Supply and installation of industrial type thermometers
Supply, installation, testing and commissioning of air curtain.
MS channel -125 ISME
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray (Galvanization thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanized Iron cable tray "bends" (galvanization not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
100 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness.
Buyback cost of the dismantled, defective/ unserviceable articles like AHUs, condenser Coils, cooling tower, condenser pipe and valves of large size etc.
CIS GLOBAL INFRATECH PVT LTD
Voltas Limited
S K Engineers
Airtempengineers
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .