GE 862 EWS PIN 913862 c/o 56 APO
Spl repair to bdlg No T65 Rumlidhara T38 T43 T54 Narian and provn of soakage well and septic tank at Garhi under AOR of Dett A at Naushera
2020_MES_342406_1
GER-12/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹63,000
Yes
27 Jun 2020
4 May 2020
4 Jun 2020
4 May 2020
2 Jun 2020
19 May 2020
60 days
Amount
Sch 'A' Part-I (B/R Works) Taking down chowkhats or frames (without taking off shutters from the frames) n.exc 1.5 Sqm each and removing to store complete all as specified and directed.
Description all as per srl item No 1 above but chowkhats or frames exc 1.5 Sqm and n.exc 4 Sqm each and removing to store complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving n exc 15 cm thickness below or above the ground level complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish off the site complete all as specifed and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick (Ist quality) Square/rectangular, area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and as directed.
Glazed ceramic coloured tiles of size 300x200x7mm/ 450x350x7mm thick (Ist quality) in vertical surface such as skirting/ dado etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10 mm thick backing layer of cement plaster in cement mortar 1:4 complete all as specified and as directed.
Taking up or down GI tubing 15 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
Taking up or down GI tubing 20 mm bore and connections including cleaning for refixing or removal complete all as specifed and directed.
15mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
20mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specifed and directed.
Plain cement concrete type B-1, 1:2:4 ( using 20mm graded stone aggregate) as in coping, benching, hold fasts, water troughs, bed block and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M. S . frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing mentioned in SSR Part-II 2010 complete all as specified and directed.
Steel ventilators with centre hung shutter including hinges, steel peg stay complete all as specified and directed.
Framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe 290, Gde E-165 complete all as specified and directed.
3mm thick sheet glass ordinary quality and glazing with oil putty in squares n . exc 0.50 sqm in each pane complete all as specified and directed.
Aluminium anodized barrel tower bolts 150 mm long of extruded section complete all as specified and directed.
Aluminium anodized barrel tower bolts 200 mm long of extruded section complete all as specified and directed.
Aluminium alloy handles size 150 mm fabricated type anodised complete all as specified and directed.
Butt hinges 100 mm medium weight cold rolled mild steel complete all as specified and directed.
250 mm long mild steel sliding door bolt plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
50mm thick PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) as in plinth protection laid in slope 1:12 from outer edge of the wall, finished even and fair, laid in alternate bays including providing 6mm wide joints throughtout thickness of plinth protection in concrete bays and in between walling and plinth protection, joints filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight) complete all as specified and directed.
Rotational moulded polythylene water storage tank (ISI marked) with float valve, plastic lid cover, double layered, cylindrical vertical with closed top, hoisted and fixed in position of capacity 1000 ltrs including dismantling old unserviceable tank and making connections inlcuding suitable GI wash out, over flow, nipple and including ball valve of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (minium weight 15mm-142 gms) complete all as specified and directed.
Grating doom 100 mm of PTMT (Min Weight 40 Gms) with waste hole complete all as specified and directed.
Brass chromium plated shower rose 125mm with or without swivel joints, any size inlcuding fixing to steel pipe or union complete all as specified and directed.
Brass chromium plated tubular towel rail 20 mm dia "D" type 60 cm long between flange aluminium anodised complete all as specified and directed.
Bib tap cast copper alloy with crutch or butterfly handle, chromium plated, fancy type, screwed for iron pipe, suitable for 15 mm bore complete all as specified and directed.
Stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, chromium plated, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Vitreous China water closet (squatt pan) Orrisa pattern 580x440 mm size pan, white, with front or back inlet with integral foot rests including provn of lime concrete bedding including connections to flushing cistern/pipe and including PVC P or S trap complete all as specified and directed.
Viterous China WHB, white, flat back, size 550x400mm including waste coupling, waste pipe and MS brackets complete all as specified and directed.
Supply only PVC low level flushing cistern including flush pipe 32mm dia, 10 ltrs capacity white with inlet ball valve, float valve and handle including MS brackets, PVC flush pipe complete all as specifed and directed.
Dismantling of asbestos cement (corrugated, semi corrugated etc) sheeting in roof covering complete all as specified and directed.
0.63 mm galvanised, corrugated mild steel sheeting with two corrugation side lap, fixed with 'L' or 'J' type hooks or cranked hook bolts and washers in roofs, walls etc with grade of zinc coating 275 gm/sqm complete all as specified and directed.
0.80 mm thick plain galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of Zinc coating 275 gm/sqm complete all as specified and directed.
Preparation of new or previously untreated steel or iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of Synthetic enamel paint over and including a coat of zinc chrome red oxide primer complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Walling of random rubble masonry, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed.
Description all as per srl item No 37 above but except stone using serviceable stones obtain from demolition after cleaning complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 20 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Rendering 15mm thick in CM 1:6 on stone masonry or other than fair faces of brick wall surface, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15mm thick in CM 1:4 on fair faces of brick work, surface finished even and smooth without using extra cement including mixing of water proofing compound as per manufracturer's instructions complete all as specified directed. Note:- Supply only WPC shall be measured and seprately.
Rendering 20mm thick in CM 1:6 on stone masonry surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 20mm thick in CM 1:4 on stone masonry surfaces of wall, finished even and fair without using extra cement including mixing of water proofing compound as per manufracturer's instructions complete all as specified directed. Note:- Supply only WPC shall be measured and seprately.
Supply only integral water proofing compound complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over and including a coat of cement primer complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Demolition by breaking up salt glazed stone ware drain pipe of 100mm nominal bore set in Cement Mortar complete all as specified and directed.
Demolition and breaking up salt glazed stone ware drain pipe of 150mm nominal bore set in Cement Mortar complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and n. exc. 1.5m in depth for foundation etc in soft/ loose soil and getting out complete all as specified and directed.
PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
Concrete bed to drain pipes 100 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) complete all as specified and directed.
Concrete bed to drain pipes 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in Cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) complete all as specified and directed.
Reinforced concrete pipes, 100mm bore, class NP2, laid and jointed complete with collars complete all as specified and directed.
Reinforced concrete pipes, 150mm bore, class NP2, laid and jointed complete with collars complete all as specified and directed.
Demolition of reinforced cement concrete of any description and any position not otherwise specifically provided for complete all as specified and directed.
Pre cast RCC type B-1, 1:2:4 (using 20mm graded stone aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, shelves and similar articles with plain faces complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 5mm to 10mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
PVC (SWR) 110mm bore pipes, type B, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
PVC (SWR) 110mm bore pipes, type B, single socketed in any length with rubber ring joints fixed to walls with and including MS flat iron clamps complete all as specified and directed.
PVC (SWR) 110mm bore bends any radius complete all as specified and directed.
PVC (SWR) 110mm bore 'P' trap complete all as specified and directed.
PVC (SWR) 110mm bore cowl complete all as specified and directed.
Pressed steel door frame of size 125x60 mm with one or more rebates including necessary fixing lugs, hinges, lock and strike plate etc including back filling to chowkhats in PCC 1:3:6 type C-0 using 12.5mm graded stone agregate complete all as specified and directed.
Factory made 2nd class hard wood 35 mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 003 (part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Factory made 35 mm thick 2nd class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhats complete all as specified and directed.
MS tubular Box type window (double rebate and double shutter) of MS rolled steel section conforming to IS-1038 and shall be ISI marked manufactured by ISI approved manufacturer, openable frames shall be fabricated of sections as approved by Engr-in-Charge, corner welded to form a solid fused welded joint, handles shall be of z section welded with openable frame box steel section used in outer frame, shutter frame and central frame shall be ERW secton of 16 gauge with fixing lugs to be fixed as per provision of IS-1038 except that top lugs shall not be provided , all shutters of windows shall be provided with 4 Nos friction free hinges, 2 Nos 75 mm tower bolts to each leaf of window one at top and one at bottom welded on 3 mm thick steel sheet piece of suitable size which shall be in turn welded to z section of steel window to provide suitable arrangement of using tower bolt. Glazed, gauzed window , mild steel casement stays 300 mm with hinged joint and two plates with studs complete all as specified with all fittings and fixtures with or without glazing bars complete all as specified and directed.
300mm MS ordinary rat tail pattern spring of approved make including roller and roller plate complete all as specified and directed.
2nd class hard wood small fitting such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labourers articles n exc 200cu.cm each complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with tinned tacks or galvanised wire stapples complete all as specified and directed.
Aluminum alloy, anodised, sliding door bolt 200mm long, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
Preparation of new surface of wood or wood base material of any description exc 10 cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer complete all as specified and directed.
Preparation of newly plastered surface of walls and applying two coats of oil bound distemper over and including a coat of wall care putty 1.5mm thick and a coat of cement primer complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200mm thick (Horizontal or slopping) for rough finished surface of concrete complete all as specified and directed.
RCC (1:11/2:3) type A-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns, deck slabs and in shelves and the like complete all as specified and directed.
100mm thick PCC 1:4:8, type D-2 using 40mm graded stone aggregates as in sub base of floors complete all as specified and directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 80mm thick, M-40 grade (Medium Traffic), in paths and hardstanding, with grey cement and pigment, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
Vitrified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but not exc 0.42 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, laid over and including 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
Dissmantling wrought iron or mild steel work of any description not other wise provided for complete all as specified and directed.
Rolled mild steel confirming Fe-290 (Gde E-165) roof trusses (framed), trussesed, purlins, cranes gantries, rails and fastening and heavy brackets framing (beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete all as specified and directed.
Mild steel work as in wind ties using flat iron including all necessary drilling bolting, riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but not exceeding 10 cm long and diameter of neck 16 to 20 mm complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including Nanital or similar pattern roof covering complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mm thick of approved colour having tensile strength 550 MPa as in ridges, fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed.
Drapery rod (curtain rod) mild steel heavy duty of wooden finishes, 25mm dia, fancy type and hanging/brackets/end caps, of length 1.5 mtr to 1.8 each in complete all as specified and directed.
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in surface channels and drains complete all as specified and directed.
Extra for forming fair finish to drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds etc complete all as specified and directed.
4mm thick designer ceiling board in ceiling fixed with screw as per manufacturers instructions , laid over and including hot dipped galvanised iron in post grid with 24mm wide T section exposed flanges which shall be powder coated white. The frame work shall comprise of main runner made from 0.33 mm thick galvanised steel sheet of size 24 x 32 x 300 mm spaced at 12 mm centres securely fixed to the structural soffits by approved hangers at 1200mm maximum centres. Hangers of GI wire 4 mm dia to be fixed by approved rawl plug, level adjusters and screws etc. The last hanger at the end of each main runner shall not be greater than 450 mm from adjacent wall flush fittings of 1200 mm long screws Tee with (double stiching) to interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm modules cross tee longer than 600 mm modules to be formed by fittings 600 mm long cross tee, tee perimeter wall angle shall be of 0.45 mm thick galvanised steel of size 19 x 19 mm and 300 mm long of white colour all as per insturctions including dismantling of existing board etc complete all as specified and directed.
Hat pegs, solid body of aluminium 125mm to 175mm complete all as specified and directed.
Dismantling framed trusses n exc. 10m span of any description complete all as specified and directed.
Fixing only roof trusses (framed), trussed, purlins, crane gantries, rails and fastening, and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pieces, cleats etc complete all as specified and directed. (using old steel sections obtained from dismantling of framed trusses).
Construction of septic tank with cover slab RCC (1:2:4, type B-1) for 50 users, brick work in CM 1:4 (with top of slab at ground level) including necessary excavation and earth work in any type of soil and disposal of surplus soil as directed, RCC manholes covers with angle iron welded frame complete, vent shaft with cowl all as shown on drg No. CE/TD1202/03, sh 1/2 and 2/2 and as specified.
Construction of soakage well 1.20 Mtr dia and 3 M deep including excavation and earth work in any type of soil, PCC 1:3:6 in foundation, walls of honey combed masonry with top ring of RCC 1:2:4 type B-1 including intercerpting chamber and screen chamber made of Brick masonry in CM 1:4, RCC cover slab in 1:2:4 type B-1/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and shown on drawing No CE/TD 1202/2008 SH 1/2 & 2/2.
PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in as in foundation filling and mass concrete complete all as specified and directed.
150 mm bore grade 'A' salt glazed stone ware pipes laid in trenches and jointed in CM (1:1) including testing complete all as specified & directed.
Sch 'A' Part-II (E/M works) Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Point wiring for one light point/fan point controlled by one-one way switch with 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable drawing in and including non metalic rigid PVC casing & caping complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated bakalite sheet as top cover, and 1.5 Sqmm (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly compete all as specified and directed.
Description all as per Serial item No 104 above but for one 3 pin 5 Amp socket outlet on independent board complete all as specified and directed.
Description all as per Serial item No 104 above but for one 3 pin 5 Amp socket outlet on same board complete all as specified and directed.
Description all as per Serial item No 104 above but for one 3 pin 15 Amp socket outlet independent with cable 2.5 sqmm PVC insulated FRLS multistranded copper conductor cable with 2.5 sqmm single core multistranded FRLS copper conductor cable as earth lead complete all as specified and directed.
Switch piano, flush type single pole, one way 5 Amp, 240 volts complete all as specified and directed.
Switch piano, flush type single pole, one way 15 Amp, 240 volts complete all as specified and directed.
Socket out let 2 in 1, 3 pin 5 amp flush type complete all as specified and directed.
Socket out let 2 in 1, multipurpose 5 & 15 Amp flush type complete all as specified & directed.
Ceiling rose two to three terminal (65 x 50mm), PVC/ polycarbonate insulated body complete all as specified and directed.
Ceiling fan regulator elctronic, stepped type, hum free suitable to control speed of fan from 0 to 100% rotary type five step 240 volts AC complete all as specified and directed. Make Bajaj /Usha/havells/CG
Lamp holder insulated body PVC/ Polycarbonate type with back plate suitable for batten/angular/pendent fittings including LED lamp 9 watt complete all as specified and directed.
LED Tube light fitting T-5 LED, Battens type 1x 20 watts, 4 feet white Indoor decorative aluminium extruded, integrated type complete with all accessories prewired and connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm complete all as specified & as directed by Engr in Charge. Make C&S model No. LTTB4F20WLED P/W or equivalent in Philips/Havells/Bajaj
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sq mm 2 core, laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed.
Supply and fixing in repairs sheet metal enclosure MCB distribution board triple pole & neutral 430 volts 4 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .(Note-MCBs will be measured and paid for separately).
MCB SP 240 volt any rating from 5 to 32 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
MCB SPN 240 volts 40 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
MCB TPN 415 volts 63 amps conforming to IS 8828 of 1996, with rupturing capacity 10 KA ,inculding providing thimble for out going cable complete all as specified & directed.
Sand cushioning to underground cable, provided with a layer 8 cm deep before and 15 cm thick after laying and stretching, jointing and testing the cable complete all as specified and as directed. Note: Punned thickness of sand shall be measured and paid.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
GI pipe 25mm bore light grade (ISI marked) with all fitting fixed to wall, poles or under road crossing etc with suitable size clamps for protection of cable complete all as specified and directed.
High efficacy 2'x2' recess LED flat panel light 36W LED 2700/3000K (warm white) edge-lit luminaire suitable for armstrong/grid ceiling complete for low ceiling applications complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:- Havells/Bajaj/Crompton Greaves.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 4 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed.
Supply and fixing in repairs sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification .(Note-MCBs will be measured and paid for separately).
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level, earth plate surrounded by and packed with 15 cm thick layer of char coal dust and common salt, earth lead GI wire 4.00 mm dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm bore and water pipe 20 mm bore GI light grade with funnel and wire mesh PCC chamber in cement concrete 1:3:6 type C-2 & RCC cover all as specified & shown in elect plate No. 3 of SSR part I of 2010 including testing on completion complete all as specified and directed.
Sub main wiring complete with 2 runs of 6 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable along with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor cable as earth continuity conductor drawn through and including PVC casing caping of suitable size complete all as specified and directed. Note : One run of cable and one run of casing caping shall be measured as one unit.
Sub main wiring complete with 2 runs of 4 sqmm single core PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable along with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade multi stranded copper conductor cable as earth continuity conductor drawn through and including PVC casing caping of suitable size complete all as specified and directed. Note : One run of cable and one run of casing caping shall be measured as one unit.
Supply and fixing in repairs sheet metal enclosure single pole & neutral with a two pin and earth pluck and socket complete with one single pole MCB, 20 Amp, 240 volts complete all as specified and directed.
Street light fitting LED 30 watt made up of grey powder coated pressure die cast aluminium housing having IP65 control gear and lens compartment. Fixture should have isolation in lense compartment and driver compartment and fitting must be top openable for easy maintenance and remain intact its IP protection forever after once it is open for repair. IP protection should be intacted for enhancing the overall efficiency of light. Fixture and driver should be of same make. Driver of the fixture must have enclosure and having vent from ends to prevent the driver from condensation effect and it should be BIS approved and R number should be mentioned on the top of the LED driver having voltage band of 110-300 Volts AC, THD <10% KV and also having surge protection inbuilt on driver is min 5KV and external SPD of 10KV outside the driver inside the fixture to prevent the fixture from non requirerd SUGRG. Driver should be equipped with over voltage short circuit and reverse polarity protections, driver must be constant current and constant voltage based (CVCT) fitting should having system efficiency of more than 100 lumens/watt. Fixture should be equipped with secondary lenses for better distribution of light. OEM must have its own manufacturing facility in regards to this OEM must produce the necessary documents of its own manufacturing along with the details of testing equipment and the respective Make : Crompton Cat Part No LSTP-30-CDL or its equivlant commericially and technically in Bajaj/Havells/Philips/C&S Note :-1. Contractor shall obtain LM 79 and LM 80 test report (Electrical, photometry and chromaticity) (from third party NABL Lab only and inhouse NABL lab test will not be considered) for the light fitting from the manufacturer before supply of material and submit to the department. 2. A certificate of Guarantee shall be submitted by the contractor for period of 3 (three) years from the certified date of completion of work as a whole for repair/replacement of lamp and light fittings to GE. Performance guarantee amount @5% of quoted amount of LED lamp and light fittings shall be kept reserved for a period of three years. Accordingly ,performance guarantee amount shall be released after gaurantee period. 3. The manufacture LOGO shall be embossed into housing of luminaire. 4. Luminarie shall be provided with all parameters mentioned above. 5. Make of LED chip should be Cree, Nichia, Lumiled, Osram.
Street light bracket made out of 40mm bore GI Pipe light grade 1.2 metre long bend to shape and fixing on wall with 2 Nos suitable size MS clamps including screws complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sq mm 2 core laid in trenches/ on poles/ under road crossing etc. complete all as specified and directed.
GI pipe 40mm bore light grade (ISI marked) with all fitting fixed to wall, poles or under road crossing etc with suitable size clamps for protection of cable complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S Darshan Kumar
M/S SURINDER PAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .