| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹2.6 CrQualified 113 KHAMLA GREEN PALACE GURUSANGAT DARBAR ROAD VILLAGE TOWN SINDHI COLONY CITY NAGPUR NAGPUR MAHARASHTRA 440025 INDIA | NAGPUR | MAHARASHTRA | 440025 | ₹2.6 Cr | L2 | Qualified MSE, MII, Category: General |
| 2 | L3₹2.6 CrQualified 131 JANGALPUR ROAD AIRPORT GATE NO 3 3 NO MOTILAL COLONY 24 PARGANAS N KOLKATA 700081 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700081 | ₹2.6 Cr | L3 | Qualified MSE, MII, Category: General |
| 3 | L4₹2.4 CrQualified | ₹2.4 Cr Quoted ₹2.7 Cr | L4 | Qualified MSE, MII, Category: General |
| 4 | L5₹2.8 CrQualified 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹2.8 Cr | L5 | Qualified MII |
| 5 | Qualified KOLKATA NORTH 24 PRAGANAS WEST BENGAL 700028 INDIA UDYAM WB 14 0004003 19AEIPB6323B1ZZ R 21AEIPB6323B1ZE S | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | - | - | Qualified MSE, MII, Category: General |
Tender Value
₹3.0 Cr
EMD Value
₹6.0 L
Closing Date
23 Mar 2023, 6:00 pmClosed
ANNUAL OPERATION AND MAINTENANCE CONTRACT OF E
4506139
GEM/2023/B/3206604
Two Packet Bid
O and M of E and M installations,CPWD DSR - 2018,Servicing of 11 KV HT panel,Servicing of LT Panel,
730 days
West Bengal; Darjeeling
Total value wise evaluation
BOQ
9 documents required · 9 mandatory
3 yrs
₹3
80%
₹6.0 L
23 Mar 2023
2 Mar 2023
23 Mar 2023
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | O and M of E and M installations | Operation and Maintenance of Electrical and Mechanical installations (Conveyor Belts, Lifts,Fire Alarm and Fire Fighting System etc.) of Operational and Non-Operational areas including periodical maintenance, repairs, attending to complaints /fault /breakdowns and taking rectification action, ensuring serviceability / satisfactory working condition of the entire system, maintenance of records/documentation etc. on all days including Sundays and holidays on round the clock basis complete as required, as per the detailed specifications, terms and conditions covered under this contract. | 24 | Month | Subhra Santa Ghosh 734421,AIRPORT DIRECTOR, AIRPORTS AUTHORITY OF INDIA | 730 |
| 2 | CPWD DSR - 2018 | Complete items of CPWD schedule of rates (electrical) internal & External- 2018 as and when required basis.
Total amount of work to be executed amounting to Rs. 3,00,000.00 during contract period as per DSR 2018.
(Note- Example for quoting the rate-
(i) If bidder wants to quote the rates at par with rates of DSR-2018 (E and M), then bidder has to quote Rs. 3,00,000.00 in the rate column.
(ii) If bidder wants to quote the rate 10% above on rate of DSR-2018 (E and M), then bidder has to quote Rs. 3,30,000.00 in the rate column.
(iii) If bidder wants to quote the rate 10% below on rate of DSR-2018 (E and M), then bidder has to quote Rs. 2,70,000.00 in the rate column.
Above examples are for guidance to bidders only.) | 1 | Job | Subhra Santa Ghosh 734421,AIRPORT DIRECTOR, AIRPORTS AUTHORITY OF INDIA | 730 |
| 3 | Servicing of 11 KV HT panel | Servicing, Calibration and Testing of existying 11 KV HT panel consist of (a) 1 incomer- 1250 A VCB and 2 outgoing - 800 A VCB (b) Overcurrent and earth fault current relay (Nos.), (c) Auxiliary/Trip relays -7 Nos (d) Annuciator(03 Nos.) and meters(03 Nos.) through calibration machine having valid calibrated certificate of Govt./NABL lab and submission of test reports complete as reqd. | 2 | Jobs | Subhra Santa Ghosh 734421,AIRPORT DIRECTOR, AIRPORTS AUTHORITY OF INDIA | 730 |
| 4 | Servicing of LT Panel | Servicing, Calibration and Testing of LT Panel consist of (a) ACB, Model - L and T, C - Power - 1000 A (5 Nos.) (b) ACB, Model - L and T, C - Power - 2000 A (3 Nos.) through calibration machine having valid calibrated certificate of Govt./NABL lab and submission of test reports complete as reqd. | 1 | Jobs | Subhra Santa Ghosh 734421,AIRPORT DIRECTOR, AIRPORTS AUTHORITY OF INDIA | 730 |
| 5 | Filtration of transformers | Filtration of transformer oil in 1.25 MVA, 11KV / 415 V transformer including testing of transformer oil (acidity, BDV, etc.) before and after filtration, confirming to latest indian standard at site till the reach of satisfactory di-electric strength of 50KV or above and submitting the report, also Testing of Winding Temperature Indicator (WTI), Oil Temperature Indicator (OTI), Buchholz Relay, Pressure Release Valve (PRV) and replacement of silica gel of transformer etc as complete as required. | 4 | Job | Subhra Santa Ghosh 734421,AIRPORT DIRECTOR, AIRPORTS AUTHORITY OF INDIA | 730 |
| 6 | Top up of Transformers oil | Top up the Transformers with ISI marked Transformer oil during filtration as per site requirement etc complete as required. | 100 | Ltr | Subhra Santa Ghosh 734421,AIRPORT DIRECTOR, AIRPORTS AUTHORITY OF INDIA | 730 |
| 7 | Repairing of ceiling fan | Repairing including rewinding and replacement of bearings of ceiling fan/wall fan/ exhaust fan of all make/model/type including transporting from the AAI store (as may be required) and returning back after thorough service etc as complete as required. (Dismantled copper wire need not to return to AAI) | 40 | No | Subhra Santa Ghosh 734421,AIRPORT DIRECTOR, AIRPORTS AUTHORITY OF INDIA | 730 |
| 8 | Repairing of Air curtains | Repairing including rewinding and replacement of bearings of Air curtains/Air-Circulators/ Pedestal fan of all make/model/type including transporting from the AAI store (as may be required) and returning back after thorough service etc as complete as required. (Dismantled copper wire need not return to AAI) | 20 | No | Subhra Santa Ghosh 734421,AIRPORT DIRECTOR, AIRPORTS AUTHORITY OF INDIA | 730 |
| 9 | Repairing of monoblock pump | Repairing including rewinding and replacement of bearings of three phase monoblock pump set upto 5HP rating of all make/model/type including transporting from the AAI store (as may be required) and returning back after thorough service etc as complete as required. (Dismantled copper wire need not return to AAI) | 5 | No | Subhra Santa Ghosh 734421,AIRPORT DIRECTOR, AIRPORTS AUTHORITY OF INDIA | 730 |
| 10 | Repairing of submersible pump | Repairing including rewinding and replacement of bearings of three phase submersible pump set upto 5HP of all make/model/type including transporting from the AAI store (as may be required) and returning back after thorough service etc. as complete as required. (Dismantled copper wire need not return to AAI) | 2 | No | Subhra Santa Ghosh 734421,AIRPORT DIRECTOR, AIRPORTS AUTHORITY OF INDIA | 730 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_4506139.pdf
GEM_BID
scc_2023-03-01-15-52-18_160f9e91f2b26fa52d1853ac94bb0658.pdf
BOQ
boq_2023-03-01-15-52-18_b1255b46f52e4a450bfeaee9a3a4836d.csv
BOQ
ATCC_e67eb449-e218-4352-aa9c1677758987357_santaghosh@aai.aero.docx
OTHER
gtc.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .