Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹35.6 L+₹1.6 L (4.57%)Rejected-Finance NEAR MPEB OFFICE DHANA DISTT SAUGOR MP 470228 | DHANA | SAUGOR | MP | 470228 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹36.3 L+₹2.3 L (6.76%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹38.0 L+₹4.0 L (11.7%)Rejected-Finance 117 GURU AMAR DASS NAGAR BHAISA SAUGOR MP | SAUGOR | SAGAR | MP | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹39.8 L+₹5.7 L (16.9%)Rejected-Finance BUNGLOW NO 1 RAJPOOT VILLA BARARU ROAD PATKUYI BARARU SAGAR MP 470002 | SAGAR | SAGAR | MADHYA PRADESH | 470002 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹42.6 L
EMD Value
₹85,200
Closing Date
1 Nov 2023, 6:00 pmClosed
GARRISON ENGINEER SAUGOR
Military Engineer services Garrison Engineer Saugor MP- 470001
PROVN OF CHAIN LINK FENCING AND SPECIAL REPAIRS TO CERTAIN BLDGS UNDER GE SAUGOR
2023_MES_621816_1
GE/SGR/TOK-52 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
SAUGOR
Class D category a (i) and as per tender documents
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER SAGAR
₹85,200
Yes
30 Nov 2023
6 Oct 2023
3 Nov 2023
6 Oct 2023
1 Nov 2023
20 Oct 2023
6 Oct 2023 - 13 Oct 2023
Amount
S&F pre- coated coloured galvalume Aluminum Zinc coating profile pattern steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa and AZ150 as in roof covering/ clading to wall, including crimping sheet at end fixed with self tapping screws including dismantling of Asbestos cement (corrugated, semi corrugated, etc) sheets roofing complete all as specified and directed.
S&F 0.45 mm thick galvalume sheet precoated coloured for ridge having tensile strength of 550 Mpa and AZ150 fixing for closing gable truss suitable for profile pattern sheet fixed with self driving screws including dismantling of Asbestos cement (corrugated, semi corrugated, etc) sheets roofing complete all as specified and directed.
Dismantling unframed timber scantlings 40 sq. cm & over in section, in any position complete all as specified and directed.
S&F rolled mild steel section in roof trusses ( framed), trused, purlin, crane gantries, raills and fastenings and heavy braket framing (beams, tee , angle,channel or flat sections) including distance pices, cleats etc(welded/reviting) conforming to Fe 410-W (Gde-E250) quality 'A' complete all as specified and directed.
S&F structural steel work as in tubular trusses including special shaped washer complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and directed.
S&F mild steel plates (plain or chequered) channels square cut to or notched forming holes with riveted bolted or welded attachment conforming to Fe-410W complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal / square heads at one end & screwed the other/ screwed both ends, each screwed end to be fitted with washers & one hexagonal or square nut, length of bolt exc 22.5cm & not exc 30cm long, dia of shank 16 to 20 mm complete all as specified and directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer of surfaces over 10cm width or girth complete all as specified and directed.
S&F 600mmx600mmx4mm thick ‘E’ Board Classic (Make-Everest industries Ltd) Design Lake & hill as in false ceiling including supply and fixing GI ‘Tee” grid frame work made of special section of M.S galvanized sheet 0.30mm thick , bottom portion painted with cellular nitro painting, warping the suspending wire around the existing wooden/steel purlin /rafter for suspending grid frame work of size 605mmx605mm suspended with 4 mm dia GI wire @ 1200mm c/c on main Tee and fixed to T-grid with the help of level clip or as per manufacturer direction. The section consisting of main Tee 37mmx24mmx0.60mm, cross runner tee 37mmx24mmx0.60mm and perimeter angle of 24mmx24mmx0.50mm thick. Perimeter angle to be fixed to wall with GI screw of 40mm long @ 450 mm c/c along the perimeter of wall including applying two coats of distemper oil emulsion complete all as specified and directed including Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness and any description, including cover fillets etc, complete all as specified and directed.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 including demolition of brick masonry, built in cement mortar incl all quoins, arches, pillars, etc and removing of rubbish off the premises complete all as specified and directed.
M & L for rendering 15mm thick cement plaster on brick wall / Concrete surfaces in cement mortar 1:4 with WPC @ 3% by weight of cement, finished the surfaces fair and even complete all as specified & directed. Note:-Water proofing compound shall be measured and paid separately under respective item
M & L for rendering 15mm thick cement plaster on wall in cement mortar 1:6 on brick wall / Concrete surfaces of finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and removing rubbish from site complete all as specified and directed
M & L for rendering 15mm thick cement plaster on brick wall / concrete surfaces in cement mortar 1:4 with WPC @ 3% by weight of cement, finished the surfaces fair and even complete all as specified & directed. Note:-Water proofing compound shall be measured and paid separately under respective item
M & L for rendering 15mm thick cement plaster on wall in cement mortar 1:6 on brick wall / concrete surfaces of finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for prepration of newly plastered wall sufaces & applying two coats exterior emulsion weather proof paint over one coat of exterior wall primer complete all as specified and directed. Make Asian ACE or equivalent make as specified in Appx 'C' of list of makes of Particular Specifications
M & L for prepration of new wall surfaces & applying Birla / J. K. wall care white putty 2 mm thick for levelling the surfaces including properly making of 'V' shaped crakes and filling of all crakes with crakes seal of walls and applying two coat of interior emulsion paints over a coat of wall primer incl. preparation of surfaces of walls complete all as specified and directed
M&L for complete removal of existing treatment on walls and prepration of old surfaces and applying two coats of exterior emulsion weather proof paint over one coat of exterior wall primer including properly making of v shape crakes and filling of all crakes with crakes seal of walls complete all as specified and directed
M & L for complete removal of existing treatment on wall and prepration of old surfaces & applying Birla / J. K. wall care white putty 2 mm thick for levelling the surfaces including properly making of 'V' shaped crakes and filling of all crakes with crakes seal of walls and applying two coat of interior emulsion paints over a coat of wall primer incl. preparation of surfaces of walls complete all as specified and directed
Supply only integral water proofing compound ISI marked complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n exc 15cm below or above ground floor and removing rubbish from site complete all as specified and directed
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) foundation filling and mass concrete complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-1 (using 20mm graged stone aggregates) as in floors finished rough to receive the tiles complete all as specified & directed.
M&L for nonskid coloured ceramic tiles 7 to 8 mm thick area of each tile exc 0.11 Sqm but not exc 0.18 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match coiour/shade including 15mm thick screed bed layer in CM 1:6 ncluding dismantling of floor, hearth tiling including cement mortar bedding and removing of rubbish off the premises complete all as specified and directed
M&L for glazed ceramic coloured tiles on vetical surfaces size 600x300x7mm to 8 mm thick over & including 10mm thick rendering in CM 1:4 set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade /colour of tiles including dismantling of floor, hearth tiling including cement mortar bedding and removing of rubbish off the premises complete all as specified and directed .
M&L for non skid ceramic coloured tiles 7 to 8mm thick area of each tile exc 0.18 Sqm but not exc 0.38 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screeed bed layer in CM (1:6) including dismantling of floor, hearth tiling including cement mortar bedding and removing of rubbish off the premises complete all as specified and directed
All as per Srl item No.26 above but in dado / skirting laid over and including 10 mm thick rendering in CM 1:4 including dismantilig of tiles -ditto-
M&L for mirror polished Machine cut kota stone slab flooring 18mm to 20mm thick size not less then 550mmX550mm laid over and including 20mm thick screed in CM(1:6) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.including dismantling of floor ,herath tiling /kota stone including cement mortar bedding and removing of rubbish off the premises complete all as specified and directed
M&L for Kota stone slab 15mm to 18mm thick in skirting, over 15mm thick plater in CM (1:4) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.including dismantling of floor ,herath tiling /kota stone including cement mortar bedding and removing of rubbish off the premises complete all as specified and directed
M&L for grinding and polishing mirror finish of existing Kota stone slab flooring complete all as specified and directed
Taking down chowkhats or frame exc 1.50 Sqm but not exc 4 Sqm each with shutters (with out taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frame not exc 1.50 Sqm each with shutters (with out taking off shutters from the frames) complete all as specified and directed.
S&F pressed steel frames of size 125mm X 60mm with rebate on both side including necessary fixing lugs, hinges, locks strike plate etc(thickness of sheet shall be 1.25mm) complete all as specified and directed.
S&F pressed steel frames of size 105mm X 60mm with one or more rebates including necessary fixing lugs, hinges, locks strike plate etc (thickness of sheet shall be 1.25mm) complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) as in filling of hold fast, chowkhats, etc., complete all as specified and directed.
S&F factory made PVC door frame of size 50 mm x 47 mm made out of 5 mm prelam PVC sheet cut at corner and jointed with 02 Nos 150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge (EPDM) rubber gasket weather seal provided through out the frame and fixed to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos. of screws to be provided for each vertical number & minimum 02 Nos. for horizontal member) complete all as specified and directed
S&F 35mm thick Flush shutters , solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed
S&F 35mm thick second class hardwood glazed and skeleton shutters open rebated and prepared to receive glass gauge etc (without sash bars) edges of farrming plain chamfered or rounded fitted with cut and mitred beads for securing glass etc ,size of member of shutter as specified in SSR Part -I ,section 8,clause 8.20(a) supplied and fitted to chowkats complete all as specified and directed
S&F factory made Solid PVC moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face,incl 03 Nos of 100mm size stainless steel butt hinges for each shutter complete all as specified and directed
S&F powder coated anodised aluminium ventilator shutters, half portion will be fixed with 4mm thick frosted glass and half portion will be fixed with louvers with 4mm thick frusted glass with rubber gasket and aluminium beading ,aluminium grill with fixing arrangement (wt. of grill not less then 2.50 kg/sqm),aluminium wire mess 0.45 mm dia to be fixed over louvers portion, aluminium sections weighing 0.55 kg/m complete all as specified and directed
S&F aluminium windows and ventilators sliding type three track powder coated consisting of frame 91.80 mm x 45 mm shutters 39 mm x 18 mm with rollers and locking arrangements with 4 mm thick plain glass with rubber gasket and aluminium beading , Al. handle,aluminium grill with fixing arrangement (wt. of grill not less then 2.50 kg/sqm),aluminium wire mess 0.45 mm dia etc including necessary cutting holes on wall and floor and confirming to IS complete all as directed by Engr-in- Charge (Al. section thickness 1.50 mm }
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregates) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F butt hinges medium weight cold rolled mild steel of 125 mm and fixed with screw complete all as specified and directed
S&F aluminium anodised barrel tower bolts of extruded section, length of bolt in 200 mm and fixed with machine made screws complete all as specified and directed
S&F aluminium handles 150 mm size, cast type, anodised. and fixed with machine made screws complete all as specified and directed
S&F mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed
M&L for preparation of new wooden surfaces of any description, not otherwise described over 10cm width or girth applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for 18mm to 20 mm thick Granite slab of any shade ( table rubbed and polished ) machine cut for floor /shelves in steps, jambs, pillars, window cills& cooking plateforms over 15 mm thick cement mortor 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match shade of the slabs laid bedded and pointed in any mortor complete all as specified and directed
M&L for rounding to the edge of stone slabs one edge such as in steps, cooking plateform and other similar situations complete all as specified &directed.
M&L for cutting chases, pinning in, Stone, concrete block or slab walls for concealed water tubing and making good, in cement mortor 1:3 cutting not exceeding 20cm girth complete all as specified and directed.
S&F in replacement 15mm bore Galvanised Mild steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed
S&F in replacement 20mm bore Galvanised Mild steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed
S&F in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges fixed with and including chromium plated screws and wooden /plastic cleats (min wt 190 grams) complete all as specified & directed.
S&F in repair vitreous China wash down water closet pan (pedestal pattern), white including white seat cover complete all as specified and directed.
S & F in repair PVC valveless Syphonic action type, Flushing cistern 10 litres capacity low level, white with inlet ball valve float handle and flush pipe 32 mm bore and brackets complete all as specified and directed.
S&F in repair vitreous China wash hand basin white flat back of size 550mmx400 mm (overall) and including cutting for and pinning in end of brackets,32 mm waste fittings,brass chromium plated for glazed ware sinks,basins etc.with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed.and flush pipe of polytethylene of low or high density or PVC 32 mm dia incl waste pipe and with centrally fixed brass chroium plated 15 mm bore pillar tap fancy type including 32 mm sink coupling complete all as specified and directed.
S&F in repair vitreous China urinal half stall type flat back of size 375mmx395mmx590mm (minimum) white with grating and union for discharge pipe, waste pipe, urinal spreader PTMT incl PVC connection 15 mm bore and 450 mm long complete all as specified and directed.
S&F in repair bib taps, cast copper alloy chromium plated fancy type with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule of 15 mm bore and fixed complete all as specified and directed.
S & F in repairs brass chromium plated shower rose fancy type , as approved by GE, with or without swivel joints, including fixing to steel pipe complete all as specified and directed.
S&F in repairs 15 mm bore Cast copper alloy chromium plated wall mixer for mixing hot & cold water screwed down for iron pipe & fixed complete all as specified and directed.
S&F PVC connections 15mm bore size 450mm in length with both end brass/pvc high quality nuts complete all as specified and directed.
S&F in repairs stop valves/angle valve 15mm bore cast copper alloy chromium plated, fancy type, cast copper alloy screwed down, high pressure, with scrutch or butter fly handle screwed both ends for iron pipe or for unions,complete all as specified and directed.
S&F in repair 15mm bore C P bib taps, cast copper alloy fency type two way with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair Hand shower (Health faucet) , one metre long flexible tube & wall hook complete screwed for iron pipe bore dia 15mm complete all as specified and directed.
S&F in repair 25 mm bore SS Pipe curtain rods including SS Brackets & SS Decorative dome, suitable for door/widows curtain with fancy type powder coated SS dooms with ss brackets fitted to each end and fixed to wall complete all as specified and directed.complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) pipes single soketed in any length with rubber ring jointed laid in trenches or in floors complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) pipes single soketed in any length with rubber ring jointed and fixed to walls with suitable size mild steel clamps complete all as specified and directed.
S&F in repairs 75 mm dia PVC (SWR) pipes single soketed in any length with rubber ring jointed laid in trenches or in floors complete all as specified and directed.
S&F in repairs 75 mm dia PVC (SWR) pipes single soketed in any length with rubber ring jointed fixed to wall with suitable size mild steel clamps complete all as specified and directed.
S&F PVC (SWR) bends 110 mm dia complete all as specified and directed.
S&F PVC (SWR) bends 110 mm dia with access door complete all as specified and directed.
S&F PVC (SWR) bends 75 mm dia all as complete all as specified and directed.
S&F PVC (SWR) bends 75 mm dia with accessable door complete all as specified and directed.
S&F PVC (SWR) 110 mm dia junction, single(single 'T') equal or unequal with acess door complete .
S&F PVC (SWR) 75 mm dia junction, single(single 'T') equal or unequal complete all as specified and directed. .
S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
S& F in repairs of 75mm dia PVC (SWR) multi floor trap with Hinge type SS grating including jointing with solvent cement complete all as specified and directed.
M&L for 600mmx600mmx7mm thick vinyl face, cinyl covered edges and washable metalized polyster foil backing,weight @ 5.6 kg/Sqm suspended false ceiling comprising of non asbestos fibere cement building board fixed or laid/inserted to GI frame work with screws over GI perimer channel 0.55mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm conter to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fastners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled wed of 50 mm and flange of 26 mm each with lips of 10.50 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including hangers 4 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long including dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness and any description/type, including cover fillets complete all as specified and directed. Make ArmGyp-FB ceiling (Armstrong) model : sleet (Alpha Lite) or equivalent make as specified in APPX 'C' of Particular Specifications
M&L for cement plaster in two layers on brick / stone masonry surfaces or surfaces other than fair face of brick work ,first layer 15 mm thick in cement mortar (1:6) and second layer cement plaster 10 mm thick in cement mortar (1:4) mixed with WPC @ 3% by weight of ement, finished the surfaces fair and even complete all as specified & directed. Note:-WPC shall be measured and paid separately under respective item
Excavating in post holes (or similar holes) each n exc 0.50 Cum in hard/dense soil, getting out and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed
M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregates) as in foundation, filling, mass concrete, sub-floors, floors etc complete all as specified and directed
S&F mild steel angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire , etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling bolting or riveting, etc, and similar work and similar conforming to Fe-290 Gde E-165 complete all as specified and directed
S&F mild steel round bars 12mm dia and over, cut to length, bent to shape required, includinig cranking, bending spirally for hooping of columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9 mm dia or securing with clips quality confirming to Fe-410 W complete all as specified and directed
S&F mild steel screw bolts (machine made) with hexagonal or sguare heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or screw nut not exc 10 cm long dia of shank 12 mm complete all as specified.
S&F chain link MS galvaised fenccing, any size or type fixed to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed. Make:-TATA/SAIL/JINDAL
M&L for preparation of newly steel and iron surfaces of any description not exc 10cm in width or girth when connected with other painting, applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F Galvanised 2 strand steel barbed wire 2.24mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed. Make:-TATA/SAIL/JINDAL
M&L for PCC 1:2:4, type B-1 (using 20mm graded stone aggregates) as in coping,benching to hold to lower portion of chain link fencing including necessary for work complete all as specified and directed.
Demolition of brick work or rubbled stone masonry including all qoins arches, pillars etc built in cement mortar complete all as specified and directed
Surface excavation not exceeding 30cm deep and average 15cm deep and getting out in soft/loose soil complete all as specified and directed
Taking down copper/aluminium point wiring (light fan, socket or power) complete including fittings such as switch, sockets, c/rose, lamp holders, tube light fittings, sketch fitting , wooden boards, bell push, call bell, MCBs & regulators etc & making good to disturbed surfaces & matching with the existing colour of wall floor etc. complete all as specified and directed
Taking down main switch, DB/change over/VTPN, MCCB AC box of any capacity complete all as specified and directed
M&L for concealed point wiring for the following with 1.5 Sqmm PVC-FRLSH insulated, sheathed, copper conductor, stranded 1100 volt grade cable in & incl PVC conduit, including modular metal flush boxes & modular white cover plate with frame as per site requirement all fittings such as tees, bends, elbows, etc. of External diameter 20mm all as per site requirements PVC insulated & sheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead complete all as specified and directed:-
One light, fan point controlled by one switch
One 5 Amp independent socket point controlled by one switch
One 3 pin ,5 Amp socket point with other switch on the same board
All as per item No 95 here in before but for power point wiring using with 2.5 sqmm PVC-FR LSH insulated ,sheathed, copper conductor stranded 1100 volt grade cable and 2.5 sqmm PVC insulated ,sheathed, copper conductor stranded 1100 volt grade cable as continuous earth lead complete all as specified and directed.
S&F modular switch, one way, 6 Amp 230, 1 module complete all as specified and directed.
S&F socket modular 6 Amp-2/3 pin combined 2 module complete all as specified and directed.
S&F switch modular, single pole, one way,16 Amp ,1 module 230 Volt complete all as specified and directed.
S&F socket modular 6/16 Amp, 2/3 pin combined ,2 module 230 Volt complete all as specified and directed.
S&F ceiling rose, surface backlit,three terminal complete all as specified and directed.
S&F modular lamp holder insulated with back plate suitable for Angle/Batten fitting complete all as specified and directed.
S&F modular fan step regulator 120W, 2 module complete all as specified and directed.
S&F testing and commissioning of MCB SP 6 Amp to 40 Amp 240 Volt 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
S&F in replacemet double door metallic sheet metal enclosure for MCB DB double door TPN 4 Way 415 Volts with 200 Amps rated bus bars complete all as specified and directed. Note :-The quoted rate shall deemed to included for cutting and chasing in stone masonary and making good the disturbed surfaces
S&F in replacement of TPN 63 Amps 415 V including making electrical coming/outgoing connections with lugs/thimbles complete all as specified and directed. Note :-The quoted rate shall deemed to included for cutting and chasing in stone masonary and making good the disturbed surfaces
S&F LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F metal clad box enclosure with socket plug top and MCB SP 20 Amps flushed on wall mounting enclosure with 2 pin and earth plug socket complete all as specified and directed.
S&F LED bulb 10 watt suitable for angle / batten holder fitting complete all as specified and directed.
M&L for provn of earthing complete with galvanised steel earth plate electrode, 600x600x6mm buried directly in ground (Earth pit not less than 2.25M deep below the GL) with top edge not less than 1.5 metres below ground level connected with galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel all as shown in electric plate no 3 connected to earthing test point all as specified or indicated including testing on completion.Note :- (i) The rate quoted shall also deemed to include the cost of GI wire and protection pipe upto 7.5 Mtr beyond the earth plates electrode and also the cost of the Test point. (ii) Joining of GI earth wire with pipe of the test point shall be done by using suitable cable lugs.
S&F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed..
M&L for concealed sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 4 sqmm (for main current) drawn in & incl PVC conduit conduit less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 4 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete all as specified and directed.
S&F LED light fitting mirror type withhigh out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Taking down and refixing connecting of Ceiling fan/exhaust fan after, greasing complete including connecting with copper wire complete all as specified and directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 1200, Copper winding of sweep 250MM complete all as specified and directed.
Supply, laying, connecting and testing LT XLPE insulayed, aluminium conductor of size 16 sqmm, 4 core screened, PVC bedded, galvanized steel strip armoured, heavy duty electric cable, 1100V grade, laid in trenches, passing through pipes/ducts, on walls with shadels etc complete all as specified and directed.
Excavation in trenches in soft/ loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed
Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed
Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtrs above the starting point complete all as specified and directed
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed. Note:-Punned thickness shall be measured and paid
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250mm x 150mm x 40mm complete all as specified and directed.
S&F in repair pipe galvanised iron light grade 40 mm dia (ISI marked) with all fittings laid in trenches or on pole, crossing of road,fixed on wall for protection of cables complete all as specified and directed
S&F in replacement sheet metal enclosure for DB double door, IP-43 when MCBs to be used SPN, 8 way, 240 V with 200 Amps rated bus bar complete all as specified and directed. Note :-The quoted rate shall deemed to included for cutting and chasing in stone masonary and making good the disturbed surfaces
S&F in replacement of TPN 40 Amps 415 V including making electrical coming/outgoing connections with lugs/thimbles complete.all as specified & directed.
M&L for concealed sub main wiring with two single core PVC FRLSH insulated unsheathed stranded copper conductor cable FRLS, 02 runs of 01 Single core of size 6 sqmm (for main current) drawn in & incl PVC conduit conduit less than 20mm dia ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, all as per site requirements ISI marked with one run of 01 Single core of size 6 Sqmm (As earth wire) PVC insulated unsheathed stranded copper conductor as a continuous earth wire complete all as specified incl. taking down old unserviceable sub main wiring and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green complete.all as specified & directed.
S&F MCB SPN 40 Amps, 240 V 10 KA capacity having C-curve characteristics connected with suitable lugs complete.all as specified & directed.
siddhant construction
m/s mohansingh
AJIT SINGH TUTEJA
dipangashu barick and associates
M K Construction
A Raza Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .