Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.5 L+₹6.2 L (22.8%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹44.3 L+₹17.0 L (62.2%)Rejected-Finance FLAT NO F2 BLOCK A FIRST FLOOR THE LEGACY APARTMENT AIRPORT ROAD GOLA KA MANDIR GWALIOR MP 474005 | GWALIOR | GWALIOR | MADHYA PRADESH | 474005 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹44.9 L+₹17.6 L (64.6%)Rejected-Finance THIRD FLOOR RIGHT SIDE H NO 835 KAPASHERA NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹45.3 L+₹18.0 L (66.0%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | somyaenterprises L2 | Jai Mahakaal Construction L3 | J.K & Company L1 | BEHL CONSTRUCTION CO L8 | M/s Sree Baba Traders L6 | GS ENTERPRISES L5 | Akarsha Enterprises L7 | RS GREEN INDIA CONSTRUCTION L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipe complete all as specified and directed. | 223 | Cum | 150 ₹33,450 | 250 ₹55,750 | 80 ₹17,840 Lowest | 200 ₹44,600 | 210 ₹46,830 | 180 ₹40,140 | 170 ₹37,910 | 190 ₹42,370 |
| 2.00 | Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed. | 201 | Cum | 50 ₹10,050 | 100 ₹20,100 | 10 ₹2,010 Lowest | 60 ₹12,060 | 50 ₹10,050 | 50 ₹10,050 | 35 ₹7,035 | 50 ₹10,050 |
| 3.00 | Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. | 22 | Cum | 50 ₹1,100 | 100 ₹2,200 | 10 ₹220 Lowest | 60 ₹1,320 | 50 ₹1,100 | 50 ₹1,100 | 35 ₹770 | 50 ₹1,100 |
| 4.00Taking down GI pipe line from trench/wall/floor/roof stacking it reuse or issued to contrctroctor as credit of following sizes complete all as specified and as directed :- | |||||||||||
| 4.01 | GI pipe of 15mm bore | 100 | RM | 10 ₹1,000 | 50 ₹5,000 | 5 ₹500 Lowest | 10 ₹1,000 | 10 ₹1,000 | 10 ₹1,000 | 10 ₹1,000 | 12 ₹1,200 |
| 4.02 | GI pipe of 20mm bore | 200 | RM | 10 ₹2,000 | 50 ₹10,000 | 5 ₹1,000 Lowest | 10 ₹2,000 | 10 ₹2,000 | 10 ₹2,000 | 10 ₹2,000 | 12 ₹2,400 |
| 4.03 | GI pipe of 25mm bore | 200 | RM | 10 ₹2,000 | 50 ₹10,000 | 5 ₹1,000 Lowest | 10 ₹2,000 | 10 ₹2,000 | 10 ₹2,000 | 10 ₹2,000 | 12 ₹2,400 |
| 4.04 | GI pipe of 40mm bore | 300 | RM | 10 ₹3,000 | 50 ₹15,000 | 5 ₹1,500 Lowest | 10 ₹3,000 | 10 ₹3,000 | 10 ₹3,000 | 10 ₹3,000 | 12 ₹3,600 |
| 4.05 | GI pipe of 50mm bore | 300 | RM | 15 ₹4,500 | 50 ₹15,000 | 5 ₹1,500 Lowest | 15 ₹4,500 | 15 ₹4,500 | 20 ₹6,000 | 15 ₹4,500 | 12 ₹3,600 |
| 5.00Refixing old retrived srviceable GI pipe line on trench/wall/floor/roof of following sizes complete all as specified and as directed:- | |||||||||||
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
25 Jul 2025, 6:00 pmClosed
Maj Ashish Kanyan
GE Kapurthala
Repair/Maintenance of pumping sets, raising main delivery line and water supply, E/M installation at Mil Stn Beas, 2 ASD and Jandiala Guru under GE Kapurthala.
2025_MES_717105_1
8055/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Area under GE Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹94,000
2 Sept 2025
27 Jun 2025
28 Jul 2025
27 Jun 2025
25 Jul 2025
11 Jul 2025
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for taking out and laying CI/GI pipe complete all as specified and directed.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Taking down GI pipe line from trench/wall/floor/roof stacking it reuse or issued to contrctroctor as credit of following sizes complete all as specified and as directed :-
GI pipe of 15mm bore
GI pipe of 20mm bore
GI pipe of 25mm bore
GI pipe of 40mm bore
GI pipe of 50mm bore
Refixing old retrived srviceable GI pipe line on trench/wall/floor/roof of following sizes complete all as specified and as directed:-
GI pipe of 15mm bore
GI pipe of 20mm bore
GI pipe of 25mm bore
GI pipe of 40mm bore
GI pipe of 50mm bore
S&F GI tubing medium grade in any length with all fitting laid in trench/wall/floor/roof and connecting up with water supply main complete all as specified and directed of following sizes :-
GI pipe of 15mm bore
GI pipe of 20mm bore
GI pipe of 25mm bore
GI pipe of 40mm bore
GI pipe of 50mm bore
Taking down CI pipe line from trench stacking it reuse or issued to contrctroctor as credit of following sizes complete all as specified and as directed :-
CI pipe 80mm dia
CI pipe 100 mm dia
CI pipe 150 mm dia
Refixing old retrived srviceable CI pipe of any description in trench of following sizes complete all as specified and as directed :-
CI pipe 80mm dia
CI pipe 100 mm dia
CI pipe 150 mm dia
S&F CI pipe in any length laid in trench and connecting up with water supply main complete including jointes all as specified and directed of following sizes :-
CI pipe 80mm dia
CI pipe 100 mm dia
CI pipe 150 mm dia
Taking down old unserviceable DI (K-7) pipe 100 mm bore and supply, laying, jointing and testing new DI (K-7) pipe 100 mm bore centrifugally cast class LA confirming to IS - 1536 spigot and socketed ends in any length laid in trenches complete all as specified and directed. (Note : QUOTED rate deemed to be including DI fitting and new run lead joint.
All as per item No 10 above here in before but DI (K-7)150 mm bore complete all as specified and as directed.
S&F in replacement cast iron fitting such as bends, tapers, (any type, radius and angle) tapers any type, (straight, bend, increasing,decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs tee pieces, single branch for spigot and socket and flanged pipe up to 150 mm bore complete all as specified and directed.
S&F in replacment cast iron sluice valve 80 mm bore with flanged ends, ISI mark with Gun metal spindle, CI gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S sluice valve complete all as specified
All as per srl item No 13 here in before but 100 mm dia complete all as specified and as directed.
All as per ser item No 13 above here in before but 150 mm bore complete all as specified and as directed.
M&L for valve pits of internal dimensions 90cm x 90 cm x 90 cm making good disturbed/ dismantled brick work in cement mortar (1:4) plastering surfaces in CM 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.(a) M&L for brick work using sub class 'B' (old size bricks) in CM 1:4 (b) M&L for rendering 15 mm thick in CM 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface.
M&L for lead joint suitable for CI pipe 80 mm bore complete all as specified and directed.
M&L for lead joint suitable for CI pipe 100 mm bore complete all as specified and directed.
M&L for lead joint suitable for CI pipe 150 mm bore complete all as specified and directed.
S&F in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 20 mm bore complete all as specified.
All as per item ser No 20 above here in before but 25 mm bore complete all as specified and as directed.
All as per item ser No 20 above here in before but 30 mm bore complete all as specified and as directed.
M &L for earth work in trenches / pit and bailing out water to rectfying leaking joint of CI pipe spigot and socket type 80 mm bore including pouring extra lead chieseling and levelling the excavated material after rectifying the leakage complete all as specified.
All as per item ser No 23 above here in before but 100 mm bore complete all as specified and as directed.
All as per item ser No 23 above here in before but 150 mm bore complete all as specified and as directed.
S&F 10 sqmm 3 core ,Multistranded copper conductor, PVC insulated, PVC shethed, multicore, round flexible industrial control cable, voltage grade 300/500 volt fixing on wall /floor/roof etc for connecting Over head tank water lavel indicator.
S&F for Water Level Indicator, Overhead Tank Indicator, Led Indicator for Tank Water, Water Level Displa including y Wired Sensor, Make SKYLET WLC-112 or equvelent .
M&L for Painting of all CI pipes, sluice valves of main over head tank with 2 coat of synthetic enemal paint Pipe after applying one coat of primer,marking letters as directed Note : Scope involve Pipe from Top of Over head tank to Pump House all pipe over the ground in pump house is to be painted all as directed.
Material labour and services for taking sample water in sterlised bottles from various borewells for Analysis of water for the following parameters and obtaining sample test report from Govt Recognized Laboratories: (i) Physio Chemical Analysis of Water ( Colour , odour , pH Total solids, Dissolved Solids, Permanent hardness, temporary Hardness, Ammonia feree and salinbe, Ammonia Albuminoidal, Nitrites, Nitreates, Oxygen absorption at 15 Min, Iron , Fluoride) (ii) Microbiological Analysis ( Totral Choliforms , Eschirrchea Coli) Note : 1. A certificate of approval / certification of Lab by Goivt Of India / State Govt shall be submitted by the contractor to the deptt. 2. Sample shall be submitted to the Labortory within 24 Hrs of collection of sample
Supply of Chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finish Box complete all as specified and as directed.
Supply only Calcium based granuler disinfect suitable for treatment drinking water in 45 kg plastic drum complete all as specified and directed. Make: Rayal Seema/Aquafit/Daclibac
Supply only orthotolidine reagenet for chlorine test in 500 ml bottle of make - glaxo / SDS / Ran baxy.
S&F battery 12 volts 180AH of Make : Exide/Luminous or equivalent as mentioned in Appx of list of makes.
Attending complaints by deploying sufficient labour (Skilled and helpers) for repair to leakage/blockage of wall/underground water carrying GI/CI/DI pipes of sizes, 20mm to 200 mm bore of any description at any location including necessary excavation & earth work, cutting existing pipe lines, dewatering etc complete all as specified. NOTE:- (i) Complaint shall be notified to contractor on telephone, therefore it is mandatory for the contractor to mention his ‘Mobile Number’ while quoting the tender. (ii) Complaint shall be notified to contractor at any time between 0600 hrs to 2000 hrs and the same shall be immediately attended and defects rectified within six hrs from notification of complaint to the contractor. (iii) Confirmation of attendance & rectification of complaint shall be given in writing by the contractor and same shall be recorded in the ‘Register’ maintained for the purpose. The ‘Register’ shall be produced to this office along with RAR/Final Bill. (iv) In case the contractor fails to attend complaints within stipulated time (i.e. 6 hrs), a penalty shall be imposed @ Rs 300/- per complaint. (iv) Rates quoted by the contractor shall be deemed included the cost of necessary T& P required. (v) Pipes and cost of jointing shall be measured and paid separately under respective items.
Taking down old unsv bleching dozing pump along with all accessories and Supply and install connecing. Testing and commissioning of High Pressuure single Head adjustable "AQUAFIT" Dosing system Model No VST 1005 and VST 1006 of the following specification. Adjustble High Pressure 5 Kg/Sq. cm. power input 230V, 50 Hz, 40 SPM 1/30 fractional Horsepower, Max output 10 Ltr with mandatory accessories like lead Tubing, connecting ferrules, check valves, etc (A) Preparation tank Model No VST 1005 of net capacity 100 Ltr, FRP dosing tank dia 650 x net Height 375 + conical 300. Gross height with stand 1000 mm consisting of : (i) Water inlet line (ii) Outlet with stainer (iii) Drain (iv) overflow (v) conical bottom for sludge depositing (vi) Pot hole with cover (vii) level gauge (viii) Agitator 120 watt 900 RPM single phase flange mounted motor with plastic shaft and impeller. (B) Service Tank Model No VST 1006 dia 480 x height 575 net capacity 100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 900 RPM Single Phase flange mounted moto with plastic shaft and impeller (ix) provision of mounting Pump on Lid/wall Make : VARIMA of equivalent CG.
Repair to existing valve pits of internal dimensions 90cm x 90 cm x 90 cm making good disturbed/dismantled brick work in cement mortar (1:4) plastering surfaces in CM 1:6, 15mm thick and PCC coping in cement concrete 1:2:4 type B-1 and providing MS cover in replacement made out of MS sheet 3 mm thick duly welded to MS angle iron frame 35x35x5mm including frame work as per existing size with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.(a) M&L for brick work using sub class 'B' (old size bricks) in CM 1:4 (b) M&L for rendering 15 mm thick in CM 1:4 finishing even and fair (c) M&L for PCC 1:2:4 type B-0 (using cum 12.5 mm graded stone aggregate ) as in coping (d) M&L for any type of mild steel work such as frame sheet 3 mm thick including welding (e) M&L for painting two coats of synthetic enamel paint over a coat of red oxide primer to untreated steel surface & prep of surface.
S&F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 45 HP 3 phase motor, . Make including voltmeter and ammeter complete all as specified and as directed.
S&F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 100 HP 3 phase motor, including voltmeter and ammeter complete all as specified and as directed.
S&F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 15/17.5 HP 3 phase motor, including voltmeter and ammeter complete all as specified and as directed.
S&F in replacement unserviceable fully automatic star delta starter in sheet steel enclousure in door type, having single phase and reverse polerty protection, Amper, Volt meter, 3 phase 4 wire, working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 7.5/10 HP 3 phase motor, . Make including voltmeter and ammeter complete all as specified and as directed.
Disconnecting the existing non functional submersible pump set from supply, dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity & in any position, along with existing column pipe 80/100mm dia and existing submersible cable of any size from the bore well 150/200mm bore (approximately 100 mtr depth of pump set from GL) complete all as specified and directed. NOTE: 1. Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost.
Lowering down of the submersible pump set after repair of any description and any capacity & in any position, in bore well alongwith column pipe 80/100mm dia and submersible cable of any size (approximately 60 mtr depth of pump set from GL) complete all as specified and directed including making necessary electric connections & testing the pump set after lowering. NOTE: 1. Contractor shall take proper precautions while lowering pump set in bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc shall be arranged by the contractor at his own cost. 2. Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to column pipes & assembling, jointing and fixing column pipes/pump sets/submersible cable and making necessary connections and including reconnecting water supply system. The required materials like column pipes/ /submersible cable/pump sets etc (new/old retrieved materials) shall be provided by the department to contractor for fixing and lowering in bore wells)
Supply only galvanised iron water tube 100mm bore in 3 meter length , heavy grade, ISI marked, conforming to IS-1239 (latest) for column pipe in required length but each length not more than 3.00 mtr, both end screwed with long threads/ flanged complete all as specified and directed. (NOTE: Fixing and jointing of the column pipes with sockets/flanfge, nut bolt wasers, rubber gasket are deemed to be included in the rates quoted by the contractor for lowering of the column pipes with pump sets)
Development of bores in well position with using suitable air compressor of suitable pressure (not less than 250 CFM) and capacity as approved for obtaining optimum yield and for obtaining sand free water including cast of M&Lr , T & P etc for developing complete all as specified & directed.
Development of bore well by over pumping with minimum 25% higher capacity of pump set after development with compressor complete all as specified and directed.
M&L for Yield test for tube well with the help of notch tank 90 degree by continuous pumping to determine safe pumping yield complete all as specified and as directed.
M&L for Draining out water from OHT by operating wash out valve ,Cleaning of over head tank (staging from 6 meter to 18 Meter) (inside) by scraping with the help of hard brushes and physical cleaning of over head tank (reservoir) by descaling / brooming silt and other deposit in side (bottom of dome) collecting and taking them out with help of manual labour and depositing not exceeding 50mtr all as directed. Cleaning of inner surface of OHT by applying the bleaching powder solution (1:10) and left it for 1/2 hour for making surface algee/ bacteria free .clean the surface with water and drying it quick with the help of electric air blower. Applying two coat of thick quick drying lime wash on entire surface (inner) top and bottom including writting date of cleaning with white paint on back painted surface two places and painting of inner steel ladder of tank all as specified and directed.
S&F in replacement MCCB 200 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 160 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 100 Amp 4 pole 16 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 63 Amp 4 pole 10 KA 415 Volt complete all as specified and directed.
S&F phase sequance corrector in sheet metal enclosure with phase loss protection system working on 415 Volt, 50 Hz, On/Off coil (switch) suitable for 45 HP pump working voltage 440 Voltage etc complete all as specified and directed.
M&L for disconnecting electric connection and pipe connection and taking out submersible pump & motor of capacity 12.5 to 17.5 HP from bore well and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same guage and weight to existing including replacement of , Motor bush, thrust plate coupling complete with key and alignment of motor stater's slote reassembnling the motor with pump and lowering it into bore well making it functional and testing complete all as specified and directed.
All as per item 55 above here in before but capacity 25 to 30 HP complete all as specified and as directed.
All as per item 55 above here in before but capacity 35 to 45 HP of turbine motor pump including replacerment of ball bearings complete all as specified and as directed.
All as per item 55 above here in before but capacity 100 HP of turbine motor pump including replacerment of ball bearings complete all as specified and as directed.
All as per item No 55 here in before but for pump motor of capacity 10 HP including replacement of ball bearings and alignment of motor starter and slote complete all as specified and as directed.
All as per item No 55 here in before but for submersible pump motor of capacity upto 7.5 HP including replacement of ball bearings and alignment of motor starter and slote complete all as specified and as directed.
Repair / replacment of unserviceable part of submersible pump capacity 12.5 to 17.5 HP such as gun metal bush impeller assembly remetaling/turning to shaft, locking key and MS nuts & bolts of existing size and reassembling the pump with motor and making it functional all as specified.
All as per item No 61 here in before but for submersible pump for capacity 25 HP to 30 HP complete all as specified and as directed.
All as per item No 61 here in before but for non clog submersible pump for capacity 35 HP to 45 HP complete all as specified and as directed.
All as per item No 61 here in before but for openwell submersible pump motor of capacity 2 to 7.5 HP including replacement of ball bearings and alignment of motor starter and slote complete all as specified and as directed.
S&F PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 10 sqmm in replacement of old unsv cable complete all as specified and as directed. Make : Rallison / Plaza/Fenolax.
S&F PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 16 sqmm in replacement of old unsv cable complete all as specified and as directed. Make : Rallison / Plaza/Fenolax.
S&F aviation light LED type fixed on the top of OHT of any height including necessary fixing accessories complete all as specified and directed.
S&F CI double flanged Non -return valve, class 'B', High pressure PN 1.6 conforming to ISI marked, including bolts, nuts, washer and rubber packing all as specified and directed of the 150mm dia bore:- Make : Kirloskar/BIR/Minar
All as per item No 68 above here in before but 100 mm bore dia complete all as specified and as directed.
Supply and filling pea gravel of size 3 to 10 mm to a packed thickness into the side of existing bore well (which is hollow space between casing pipe and true bore ) all as directed complete all as specified and directed.
M&L for replacement of pressure gauge 0-100 PSI, dial type fixed on pumping line in various pumps all as specified.
S&F MS clamp of size 50x6 mm, MS flat iron with one No GI/MS socket of 20mm/15mm duly welded incl nut & bolts for taking branch connection/jointing of branch connection from 40 to 150mm bore line including boring in GI/CI pipe incl rubber packing all as directed.
M&L for replacement of unserviceable digital Amp/Volt meter any type with new one complete all as specified and as directed.
M&L for replacement of CT of any ratio with new one complete all as specified and as directed.
Material and labor for replacement of unserviceable wiring of motor control panel with new one complete all as specified and as directed.
M&L for replacment of unserviceable phase indicator with new one complete all as specified and as directed complete all as specified and as directed.
M&L for replacement of unsv contactor with new one suitable for 3 phase 25 HP pump starter panel complete all as specified and as directed.
M&L for replacement of unserviceable contactor with new one suitable for 3 phase 35 HP pump starter panel complete all as specified and as directed.
M&L for replacement of old unserviceable contactor with new one suitable for 3 phase 40 HP pump starter panel complete all as specified and as directed.
M&L for replacement of old unserviceable time delay relay (Timmer) with new one suitable for 3 phase 40 HP pump star delta starter panel complete all as specified and as directed.
M&L for replacement of old unserviceable time delay current limiting relay with new one suitable for 3 phase 25/30/35/40 HP pump star delta starter panel complete all as specified and as directed.
M&L for single phase priventer suitable for 3 phase motor starter complete all as specified and as directed.
M&L for earthing complete with galvanized iron or steel or steel earth plate electrode of size 60cmx60cmx6.3mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI Strip of size 32x6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh GI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in plate No 5 of SRR-1991 Part-1 .
Taking out old defective underground cable from trenches/ floors/road/wall /pipe/ pole LT cable of any size/ description including (Note : Excavation and earth work will be measured separately under respective item)
Supply, Laying, jointing and testing XLPE PVC insulated & PVC sheathed LT cable, 1100 volts grade (heavy duty) with stranded aluminium conductor, cross sectional area 10 Sqmm 2 core fixed along the poles or passing through pipes or laid under floors or through walls complete all as specified. Note (i) Earthwork, sand cushioning, brick protection and GI pipe to be measured and paid for separately under respective items.
All as per description of serial item no.85 here in before but cross sectional area 50 Sqmm 3½ core complete all specified.
All as per description of serial item no. 85 here in before but cross sectional area 70 Sqmm 3½ core complete all specified.
M&L for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Note : For payment purposes 18cm thickness shall be considered.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate for fdn of poles, stay, valve chambers etc complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 using 20mm graded for padestal coping incl necessary formwork finished fair using extra cement complete all as specified and as directed.
somyaenterprises (BID ID -3359442)
Jai Mahakaal Construction (BID ID -3362156)
RS GREEN INDIA CONSTRUCTION (BID ID -3361111)
GS ENTERPRISES (BID ID -3363406)
M/s Sree Baba Traders (BID ID -3361318)
Akarsha Enterprises (BID ID -3363158)
BEHL CONSTRUCTION CO (BID ID -3363470)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .