| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹38.7 L+₹2.4 L (6.61%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹40.6 L+₹4.3 L (11.9%)Rejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹40.7 L+₹4.4 L (12.2%)Rejected-Finance | L4 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹81,700
Closing Date
8 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Haddo Port Blair
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDITION/ALTERATION TO OFFICERS WAITING ROOM IN BLDG NO P-12, DRIVER ROOM AT MT POOL AND PROVISION OF BOSUN STORE AT INS JARAWA UNDER GE HADDO
2020_MES_376183_1
8488/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
D a ( i) and b (i)
9 documents required · 9 mandatory
₹500
GE Haddo
₹81,700
Yes
28 Nov 2020
10 Sept 2020
12 Oct 2020
10 Sept 2020
8 Oct 2020
26 Sept 2020
10 Sept 2020 - 17 Sept 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth, for foundation etc., or for shafts, wells, cess pits, manholes, pier holes etc not exc. 10 Sqm on plan and n.exc. 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each as in soils complete all as specified and as directed
Removing excavated material (soils) to a distance not exc 50 metres and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
M&L for pre-cast cement concrete block masonry with solid blocks made up of (1:3:6) type C1 (using 20mm graded stone aggregate), masonry not exceeding 10cm in width and setting in cement mortar (1:6) complete all as specified and directed.
Material and labour for hard core broken stone aggreagate of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick,watered and rolled / rammed to a true surface complete all as specified and directed.
Material and labour for plain cement concrete, 1:4:8, type D2, using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Material and labour for reinforced cement concrete (nominal mix) 1:2:4, type B1, using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under-reamed piles and mass concrete etc., complete all as specified and directed.
Material and labour for reinforced cement concrete (nominal mix) 1:2:4, type B1, using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed.
Material and labour for reinforced cement concrete (nominal mix) 1:2:4, type B1, using 20mm graded stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
Material and labour for reinforced cement concrete (nominal mix) 1:2:4, type B1, using 20mm graded stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Material and labour for reinforced cement concrete (nominal mix) 1:2:4, type B1, using 20mm graded stone aggregate as in chajjas complete all as specified and directed.
Use and waste of formwork to pillars, posts, struts, columns and stanchions, square, rectangular or polygonal rough finished surfaces complete all as specified and directed.
Use and waste of formwork to formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc., rough finished surfaces complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces complete all as specified and directed.
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges fair finished surfaces complete all as specified and directed.
M&L for CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for CRS bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for high strength deformed TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cracking bending spirally for hooping for columns/beams, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia., complete all as specified and directed.
M&L for high strength deformed TMT steel bars 6 mm to 10 mm dia and over, cut to length, bent to shape required, including cracking bending spirally for hooping for columns/beams, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia., complete all as specified and directed.
M&L for high strength deformed TMT steel bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia., complete all as specified and directed.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based trapezoidal profile steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete. Overlap shall be provided as specified by the manufacturer.
S&F pre-painted zinc coated aluminum sheet (Galvalume) GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/valley gutters, fixed with self tapping screws including scoffolding for a height upto 12.0 metres complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers. Penetration and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc., as per SSR Part-I 2009 complete.
S&F aluminum flat iron wind ties of any size and thickness fixed with self tapping screws for fixing roofing sheets complete all as specified and as directed. NOTES: The self tapping screw shall be of adequate length to drive into complete thickness of purlin/rafter etc., and shall be fixed using neoprene and EPDM washers.
M&L for mild steel roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-410-W (Gde E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250) Quality 'A' complete all as specified and as directed.
M&L for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long and dia of bolt 11mm to 15mm complete all as specified and as directed.
M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for preparation of new wood and wood based surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint of first quality over a coat of pink primer complete all as specified and as directed.
M&L for anodised aluminium snap grid frame work for false ceiling including providing and fixing gypsum board 12mm thick in ceiling fixed with screws as per manufacturers instructions and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L for anodised aluminium snap grid frame work for false ceiling with size of grid 605mm x 605mm all as specified in SSR Part-I 2009, hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat iron 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long including cutting, drilling, jointing etc., including providing 4mm thick E-boards (classic) 605mm x 605mm size fixed or laid / inserted to aluminium frame work with screws and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
M&L for boarding (eaves / barge board) with 19mm thick plywood (BWR) fixed with screws on flat iron supports including applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Material and labour for PCC 1:3:6, type C2, using 40 mm graded aggregate, 75mm thick as in plinth protection finishing even and smooth using extra cement complete all as specified and directed.
Material and labour for PCC 1:4:8, type D2, using 40mm graded stone aggregate as in base / sub base 100mm thick complete all as specified and directed.
Material and labour for PCC 1:2:4, type B0, using 12.5mm graded stone aggregate as in flooring 70mm thick complete all as specified and directed.
Material and labour for PCC 1:2:4, type B0, using 12.5mm graded stone aggregate as in flooring 75mm thick complete all as specified and directed.
M&L for vitrified ceramic coloured tiles 10 mm thick (square/ rectangular) of approved shade, area of each tile not exceeding 0.36 Sqm as in floors etc., laid over and including 15mm thick screed bed in CM (1:4), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for vitrified ceramic coloured tiles 10 mm thick (square/ rectangular) of approved shade, area of each tile not exceeding 0.36 Sqm, for work on vertical surfaces such as skirting, dados and risers to steps etc., including 10mm thick backing coat in CM (1:3), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
M&L for glazed ceramic coloured tiles in vertical surfaces using size of tiles 350x250x7mm / 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with colour of tile with and including 10mm thick backing coat in CM (1:3) complete all as specified and as directed.
M&L for rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in two coats 5mm thick in CM (1:4) mixed with integral water proofing compound @ 3% by weight of cement over 10mm thick in CM (1:6) on fair faces of brick work or concrete, surfaces finished fair and even complete all as specified and as directed. NOTE: Water proofing compound will be measured and paid separately under relevant item of this schedule.
Supply only integral water proofing compound.
M&L for preparation of newly plastered surfaces of external walls of any description and applying two coats of weather proof antifungal (exterior grade) acrylic emulsion over a coat of primer from the same manufacturer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls of any description and applying two coats of distemper oil emulsion paint over a coat of alkali resistant primer including a coat of white cement putty, white or tinted on walls complete all as specified and as directed.
M&L for powder coated anodised aluminium partition, window and door/ventilator with frame and shutters and grill fully or partly glazed, sliding/openable/fixed fully glazed and panels fixed with panels inserts 9/12 mm thick pre-laminated particle board/sheet glass including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodized aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts etc. The size of aluminium section shall be all as specified in relevant IS Code and SSR Part-I complete all as specified and as directed. NOTES: (i) Supply only floor spring, glass, Imax hinges, SS friction hinges, particle board, aluminium fly proof mesh, solar control film will be measured and paid separately under relevant items of this BOQ. (ii) Weight of aluminium section only shall be accounted for the purpose of payment. However unit rate quoted shall be deemed to include for cost of rubber beading, neoprene packing, fittings such as handles, butt hinges, tower bolts, rollers for sliding windows, locking arrangement and fixing only of panel inserts of glass/ particle board/aluminium fly proof mesh etc. (iii) Weight of aluminium handle, butt hinges, tower bolts shall not be accounted for payment purpose.
Supply only 12mm thick prelaminated particle board, interior grade, prelaminated on one side with decorative choice lamination and other side with balancing white lamination complete all as specified and as directed.
Supply only 9mm thick prelaminated particle board, interior grade, prelaminated on one side with decorative choice lamination and other side with balancing white lamination complete all as specified and as directed.
Supply only stainless steel IMAX hinges for aluminium window shutters complete all as specified and as directed.
Supply only 5.5 mm thick sheet glass, ordinary quality black colour in squares exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only 4.0 mm thick sheet glass, ordinary quality in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Supply only aluminium expanded metal fly proof mesh cut to size,0.45mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and as directed.
Supply and fix mild steel PVC coated fancy type coloured 20mm dia curtain rods with brackets complete all as specified and as directed.
Supply and fix Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixe complete all as specified and directed.
Supply and fix aluminum Die cast body, door closer hydraulically regulated designation No.1, universal type, suitable for door shutters of upto 700 mm width and of weight not more than 35 Kg complete all as specified and directed.
M&L for 20mm thick granite work (of any type and shade as approved) table rubbed and polished as in steps, jambs, pillars, window cills, cooking platforms, wash basin counters and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite laid over and including 15mm thick cement mortar (1:4) bedding and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing, rounding (chamfering) the edges complete all as specified and directed.
M&L for glossy finished chequered cement concrete coloured tiles, of 30cm x 30cm x 20mm to 25mm thick, set jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles inclucding 20 mm thick screed bed of CM 1:4 in floors etc., complete all as specified and directed.
S&F bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
Supply and fix in repairs looking mirror 5.5 mm thick with rubber wood moulded 50 mm wide beading & mat finish mounted on 12 mm thick commercial ply complete all as specified and directed.
Supply and fix in repairs, angular stop cock cast copper alloy fancy type screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed for 15mm bore of pipe with long shank and cup complete all as specified and directed. Make : Jaquar Cat No. CON-053KN or equivalent in Marc / Kohler.
S&F bib taps, brass, 15mm dia, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule fixed in repairs complete all as specified and as directed. MAKE: JAQUAR Cat part No. ALI-85037 or equivalent in Marc / Kohler.
Supply and fix in repairs for corner glass shelf assembly with chromium plated bracket guard complete all as specified and directed. MAKE: JAQUAR Cat part No. CAN-1173 or equivalent in Marc / Kohler.
M&L for low density poly ethylene pipes (LDPE) of pressure rating 6 kg/ cm2 bore of pipe 50mm laid in trenches / fixed to walls complete all as specified and as directed.
Supply and fix Rotational moulded Polyethylene [HDPE] water tanks, triple layered, ISI Marked cylindrical & vertical type 1000 Litres capacity hoisted and fixed in position including provision of 40mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball and flynut screwed for iron pipe bore dia of 20mm (Minimum weight 210 gms) including taking down existing old tanks complete all as specified and directed.
S&F 3 layer PP-R Polypropylene Bore of pipe 20 mm random copolymer pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded elboe,Tee, socket, etc. polypropylene random fittings fixed complete to wall, ceiling or in floors etc. complete all as specified and as directed.
S&F 3 layer PP-R Polypropylene Bore of pipe 25 mm random copolymer pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot and cold water supply including all PP-R plain & brass threaded elboe,Tee, socket, etc. polypropylene random fittings fixed complete to wall, ceiling or in floors etc. complete all as specified and as directed.
Demolition of PCC block masonry, built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or steel frame, concrete or brick surrounds, complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed
S&F seamless gypsum board false ceiling 12mm thick including for any sunk or raised moulding with 25mm long self drilling / tapping screws having Philips head with joining compound and 48mm wide fiber tape to provide seamless finish and including GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding well using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including hangers 6mm dia GI adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long & expansion hold fasteners 12.5mm dia 40mm long and applying two coats of oil bound distemper with roller finsih over a coat of primer complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings etc., complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area exceeding 1.5 Sqm but not exceeding 4.0 Sqm each complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames), area not exceeding 1.5 Sqm each complete all as specified and as directed.
Supply and fix second class hard wood, plain solid straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamferred, put together with glue, pinned at joints complete all as specified and directed.
Supply and fix for 35mm thick Plain, framed, panelled shutters of 2nd class hard wood two panel, with lock rail and panels of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, the size of rail and style as per IS : 1003 (part-I), kiln seasoned chemically pressure treated complete all as specified and directed.
Supply and fix 35mm thick, IInd class hard wood glazed and skeleton shutter open rebated and prepared to receive gauze, etc., ( without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing gauze etc., size of members of shutters as specified in as Part I Sec 8 Cl 8.24 (a) complete all as specified and directed.
Supply and fix 100mm long medium weight cold rolled mild steel butt hinges fixed with screws complete all as specified and directed.
Supply and fix 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
Supply and fix 100mm extruded aluminium alloy handle, fabricated type, anodised complete all as specified and directed.
Supply and fix floor door stopper, brass body and tongue with hard drawn steel spring, overall length of cover plate 150 mm complete all as specified and directed .
Supply and fix aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
Supply and fix anodised aluminium grill of approved pattern cut to required size / shape and fixed with position with aluminium bedding & frame with & including U sections, fixed to aluminium windows / ventilators complete all as specified and directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE LIGHT / FAN point controlled by one, one way 6 Amps modular switch complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 5 PIN SWITCH SOCKET OUTLET 5/6 Amps point on independent board complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 20mm dia) medium grade and conduit accessories concealed in walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for ONE 5 PIN SWITCH SOCKET OUTLET 5/6 Amps point on same board complete all as specified and as directed.
S&F Modular socket, 6/10 Amp, 2/3 pin combined 1 way complete all as specified and as directed.
M&L for ceiling rose, three terminal, 63.5x20mm size, PVC/Polycarbonate, insulated body, 6A, 240 volts complete all as specified and as directed.
S&F modular switch, one way, one module, single pole, 6 / 10 Amps complete all as specified and as directed.
M&L for Sub main wiring complete with two runs (1P+1N) of 10 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 10 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32mm dia PVC conduit and conduit accessories fixed on surface / recessed of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 10 Sqm copper conductor, One run of 10 Sqmm copper conductor as earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 6.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 20mm dia PVC conduit and conduit accessories concealed in wall complete all as specified and as directed. NOTE: Two runs of 6.0 Sqm copper conductor, One run of 6.0 Sqmm copper conductor as earth wire and one run of PVC conduit shall be measured as one unit length.
M&L for Sub main wiring complete with two runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 20mm dia PVC conduit / casing caping and conduit / casing caping accessories fixed on surface / recessed of wall/ceiling/roof/ floor complete all as specified and as directed. NOTE: Two runs of 4.0 Sqm copper conductor, One run of 4.0 Sqmm copper conductor as earth wire and one run of PVC conduit shall be measured as one unit length.
S&F power unit athena 4 module plate 25 Amps starter, 25 Amps socket, 25 Amps plugs complete all as specified and as directed. MAKE: CRAB TREE Cat part No. ACAO252504 or equivalent in HAVELLS/L&T
S&F decorative type LED down light fittings 18 watts with LED batten in extruded aluminium housing with diffuser including all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: CROMPTON GREAVES Cat part No. LCDSPLN-R-18-CDL or equivalent in PHILIPS / C&S
S&F mirror light fittings 15 watts including all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: LUKER Cat part No. LMCL-15W or equivalent in CG / PHILIPS / C&S
S&F LED building security light fittings 25 watts including all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: CROMPTON GREAVES Cat part No. LSTS-25W or equivalent in PHILIPS / C&S
S&F wall mounting fan 400mm sweep 1330 RPM air delivery 76 m3/min with smart remote control complete all as specified and as directed. MAKE: CROMPTON GREAVES Cat part No. LSTS-25W or equivalent in PHILIPS / C&S
S&F ceiling fan 65% electricity saving smart remote control toggler operation to control speed , design blade with metalic finish 1200mm sweep 28 watts 360 RPM, air velocity 240 m3/min complete with down rod and canopy including electric connection from ceiling rose to fan connector with PVC insulated 3 core copper cable of size of 0.75 sqmm complete all as specified and as directed. MAKE: GORILLA model Pearl White or equivalent in HAVELLS / USHA / ORIENT / CROMPTON GREAVES
S&F LED spot light fitting 7 watts including all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE: HAVELLS Cat part No. LHEEAYPBMH1WOO7 or equivalent in PHILIPS / C&S
S&F MCB DB, SPN, 8-way, vertical type, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.
S&F MCB, SPN, "C" series, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed. MAKE: INDOASIAN Cat part No. 811154 or equivalent in L&T / LEGRAND
S&F MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S&F MCB, SPN, "C" series, 40 Amps, 10 KA rupturing capacity complete all as specified and as directed.
M&L for cutting channels, grooves or rebates n exc 15 cm girth, and trimming surface matching with existing colour code with putty complete all as specified and as directed.
Supply and fixing street light mounting bracket, made out of light grade GI Tubing 25mm bore, bend into shape inner angle not less tan 120° and over all length not less tan 1.2 Mtr duly painted two coats of synthetic enamel Aluminium pait over a coat of red oxide all as directed.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion including dismantling the existing earthing complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed.
Taking down existing unserviceable main switches/ distribution boards of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed.
Material and labour for Point wiring two single core 1.5 sqmm size PVC insulated, unsheathed FRLS multistranded copper conductor cable and one single core 1.5 sqmm size green colour PVC insulated FRLS multistranded copper conductor cable as earth continuity conductor, 1100 volt grade complete drawn through and including rigid non metallic PVC casing / capping with all fittings, surface on wall/roof /floor including including sunk pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover for mounting switches/ sockets/ regulators etc. complete as specified for One light / fan point controlled by one 5 Amps switch one way complete all as specified and as directed.
Material and labour for Point wiring two single core 1.5 sqmm size PVC insulated, unsheathed FRLS multistranded copper conductor cable and one single core 1.5 sqmm size green colour PVC insulated FRLS multistranded copper conductor cable as earth continuity conductor, 1100 volt grade complete drawn through and including rigid non metallic PVC casing / capping with all fittings, surface on wall/roof /floor including including sunk pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover for mounting switches/ sockets/ regulators etc. complete as specified for One 3 pin 5 Amps socket outlet on independent board complete all as specified and as directed.
Material and labour for Point wiring two single core 1.5 sqmm size PVC insulated, unsheathed FRLS multistranded copper conductor cable and one single core 1.5 sqmm size green colour PVC insulated FRLS multistranded copper conductor cable as earth continuity conductor, 1100 volt grade complete drawn through and including rigid non metallic PVC casing / capping with all fittings, surface on wall/roof /floor including including sunk pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover for mounting switches/ sockets/ regulators etc. complete as specified for One 3 pin 5 Amps socket outlet on same board complete all as specified and as directed.
Material and labour for Point wiring two single core 2.5 sqmm size PVC insulated, unsheathed FRLS multistranded copper conductor cable and one single core 2.5 sqmm size green colour PVC insulated FRLS multistranded copper conductor cable as earth continuity conductor, 1100 volt grade complete drawn through and including rigid non metallic PVC casing / caping with all fittings, surface on wall/roof /floor including including sunk pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover for mounting switches/ sockets/ regulators etc. complete as specified for One 3 pin 15 Amps socket outlet on independent board complete all as specified and as directed.
Material and labour for Point wiring two single core 4.0 sqmm size PVC insulated, unsheathed FRLS multistranded copper conductor cable and one single core 4.0 sqmm size green colour PVC insulated FRLS multistranded copper conductor cable as earth continuity conductor, 1100 volt grade complete drawn through and including rigid non metallic PVC casing / caping with all fittings, surface on wall/roof /floor including including sunk pressed steel terminal boxes with 3mm thick plastic laminated sheet top cover for mounting switches/ sockets/ regulators etc. complete as specified for One 3 pin 15 Amps socket outlet on independent board complete all as specified and as directed.
S&F socket outlet 3 pin 15 Amps flush type heavy duty 230V AC complete all as specified and as directed.
S&F switch piano, flush type, single pole one way 5 Amps 230 V AC complete all as speified and as directed.
S&F switch piano, flush type, single pole one way 15 Amps 230 V AC complete all as speified and as directed.
S&F socket outlet 2 in 1, 3 pin, 5 Amps for all pins 230 V AC complete all as speified and as directed.
S&F socket outlet 15 Amps multi socket for all pins 230 V AC complete all as speified and as directed.
S&F LED tube light fitting, 1x20 watts, 230 volts, 50Hz AC supply, with high power and high efficiency long life LEDs with built-in electronic driver, fixed on walls and provision of 3 core, 1.5 Sqmm copper cable from ceiling rose to connector of fitting complete all as specified and as directed. MAKE : PHILIPS Cat Part No. BN308CLED20S-6500L60PSUWH / CROMPTON GREAVES Cat Part No. LCCLB24-CDL or its equivalent in HAVELLS / BAJAJ
S&F LED flood light fitting, 25 watts, IR 65 luminaire comprise of elegantly designed COB LED ensure efficient optics and uniform distribution of light for street light application, pressure die cast aluminium housing powder coated graphite grey and toughened glass of IP 65 including necessary fixing arrangements as per site requirement complete all as specified and as directed. MAKE:CROMPTON GREAVES of Model Freedom Cat Part No. LSTS-25-CDL / C&S Cat Part No. LTESSE25WLED / PHILIPS Cat Part No. BRP020LEDHP/CW240V25 or its equivalent in HAVELLS/BAJAJ
S&F LED tube light fitting, 2 feet mirror optical including all accessories and fixing arrangements for fixing the light fitting complete all as specified and as directed. MAKE : PHILIPS Cat Part No. LED 48027/65/86 ultron / CROMPTON GREAVES Cat Part No. LCL-14-CDL or its equivalent in HAVELLS/C&S
Supply, lay, test and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2 core 16sqmm, laid in trenches, ducts, pole, wall etc., including taking out old unserviceable cable complete all as specified and directed. Note: (i) Necessary test results like continuity test, megger tests shall be submitted to Engineer-in-Charge before the cable is laid. (ii) Excavation earthwork will be measured and paid separately.
M&L for HDPE DWC (Double wall corrugated) pipe of size 40mm (Outer diameter) x 32mm (Inner diameter) along with connected accessories like couplers, bends, end caps, etc., laid in trenches/floors/ducts or fixed on poles/walls for as in protection of LT/ HT cable complete all as specified and as directed.
M/s Ramesh Lal
BHARAT MULTITECH INDUSTRIES PVT LTD
hrv iyengar
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .