| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹39.0 L+₹32,150 (0.83%)Rejected-Finance RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹39.4 L+₹77,250 (2.00%)Rejected-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹39.9 L+₹1.2 L (3.16%)Rejected-Finance B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹41.3 L+₹2.6 L (6.81%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹75,100
Closing Date
3 Nov 2020, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
PROVN OF CERTAIN MINOR/REVENUE WKS OF AIR CONDITIONING, DESERT COOLER,WATER COOLER,DEEP FREEZER,REFRIGERATORS AT CERTAIN UNITS AND PROVN OF ACs AT TECH STORE AT DIPAC AND COOLING SYSTEM DUCTING TYPE COOLER IN ADM BLOCK OF NEW KLP PH-I OF ESD UNDER GE
2020_MES_384009_1
GE(U)/PM/D-48/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DELHI CANTt
MES contractor enlisted under class D category d(v) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and catego
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹75,100
Yes
3 Dec 2020
6 Oct 2020
5 Nov 2020
6 Oct 2020
3 Nov 2020
20 Oct 2020
Amount
Supply, Installation, commissioning and testing of Inverter Technology Hot & Cold Split Type Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Capacity not less than 2.2 TR, minimum BEE 4 star rating , fitted with rotary compressor (5 year Warranty), Refrigerant type R-410A/R-32, cooling capacity nominal (6000 Kcl/Hrs) including outdoor stand (Wall mounted/ Floor mounted), PVC FRLS grade multi stranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, Powder coated brackets for outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall/ ceiling with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and directed. (Make:- Model No. FTXS71FVMA (Inverter Hot & Cold) of Daikin/ Model No. ASGG24LFCDB (Inverter Hot & Cold) of O-General/ Model No. RMB422ABXA/ RMOG422HDXA (Inverter Hot & Cold) of Hitachi or equivalent model of make Blue Star.)
Supply, Installation, commissioning and testing of Inverter Technology Hot & Cold Split Type Air Conditioner (indoor & outdoor unit with cordless remote control unit) of Capacity not less than 1.5 TR, BEE 5 star rating , fitted with rotary compressor (5 years Warranty), Refrigerant type R-410A/R-32, cooling capacity nominal (4500 Kcl/Hrs) including outdoor stand (Wall mounted/ Floor mounted), PVC FRLS grade multi stranded copper conductor cable 3 core 2.5 Sqmm for connections with outdoor unit, Powder coated brackets for outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipes and making good the disturbed surfaces of wall/ ceiling with cement mortar, white cement and painting work to match the existing surfaces of walls complete all as specified and directed. (Make:- Model No. FTXS50FVMA/ FTXF50TV16 (Inverter Hot & Cold) of Daikin/ Model No. ASGG18LFCDB (Inverter Hot & Cold) of O-General/ Model No. 5200XRMB517ABXA/ RSOG517HDXA (Inverter Hot & Cold) of Hitachi or equivalent model of make Blue Star.) Note:- (i) PVC drain pipe of suitable size & Heavy Duty copper connection pipes including suitable insulation upto 3 mtrs are deemed to be included in above quoted rate. (ii) PVC drain pipe of suitable size & Heavy duty copper connection pipes including suitable insulation Exceeding 3 mtrs shall be measured and paid seperately under relevant item.
Supply, Installation, commissioning and testing of voltage stabilizer for automatic operation single phase, wall mounted, copper wounded, air cooled with digital display designed for input variation between 160 volt to 260 volt with output voltage 220 ± 9% volt with calibration accuracy ± 3% with low/high cutoff, intelligent time delay facility and of capacity 5.0 KVA complete all as specified and directed. (MAKE:-APLEB/ ANDREWYULE /SINETRAC/ VOLINA/VINITEC/IECO/INDIAN TRANSFORMER & ELECTRICALS PVT. LTD.(GURGAON).
Supply, Installation, commissioning and testing of voltage stabilizer for automatic operation single phase, wall mounted, copper wounded, air cooled with digital display designed for input variation between 160 volt to 260 volt with output voltage 220 ± 9% volt with calibration accuracy ± 3% with low/ high cutoff, intelligent time delay facility and of capacity 4.0 KVA complete all as specified and directed. (MAKE:-APLEB/ ANDREWYULE /SINETRAC/ VOLINA/VINITEC/IECO/INDIAN TRANSFORMER & ELECTRICALS PVT. LTD.(GURGAON).
Material and labour for AC sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC casing caping (medium grade) of adequit size with all fittings and accessories surface type including one run 6 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed. {Note:- (i) Two runs of cable with one run earth wire and PVC casing caping shall be measured as one unit length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit quoted rate and shall not be measured separately. (iii) Earth wire shall run inside the casing caping. (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth. (v) (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of Casing Caping:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)}
Supply and fixing Single pole and neutral steel metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 to 32 Amps complete all as specified and directed by Engr-in-Charge. (Make : LEGRAND/ L&T / ABB/SEIMENS.)
Supply & fixing heavy duty copper pipe of size 6mm (1/4") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size complete all as specified and directed by Engr-in-Charge. (Make:- DIAMOND/ STAR)
-ditto- all as per item No. 7 above but copper pipe of size 12mm (1/2") dia/ bore.
-ditto- all as per item No. 7 above but copper pipe of size 15mm (5/8") dia/ bore.
Supply, Installation, commissioning and testing of Desert Cooler powder coated body of size 625mm x 625mm x 900mm height (25 inch X 25 inch X 36 inch Height) with side panels (03 Nos) fabricated out of 20 SWG (1mm thick) PGI sheet along with distribution switch, 5 amp piano switch and tank depth 275mm (11 inch), electric driven (single phase), 230 volts, 50 Hz, AC, fitted with submersible pump of suitable capacity, rotary switch (Step type, Speed Regulator), three core flexible copper conductor wire of size 1.5sqmm of not less than 1.5m length, wood wool pad on three sides and three speed exhaust motor of copper wounded, 450mm sweep complete all as specified and as directed by Engr-in-Charge. (Make : Crompton Cat No. 500MMCKM-MARKI or equivalent model/ cat No. of Bajaj/ Symphony/ Khaitan/ Kenstar)
Supply, Installation, commissioning and testing of Water Cooler fully stainless steel body (Top lid, front top/ bottom, rear top, dip tray, side panel, etc.) and chiller tank (SS 304 food grade minimum 0.80mm thickness of stainless steel sheet), chiller tank with PUF insulation (Thickness not less than 0.6mm) including float ball valve of make Prayag/ Essco of suitable size as per manufactureres design & specification with non CFC Refrigerant (R-134a), energy efficient reciprocating compressor of make Emerson/ Tecumseh suitable for operation on single phase 230 volts, 50 Hz, AC supply, having storage capacity of 80 litres and nominal cooling capacity 40 litres per hour insulated top top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray, Brass (CR plated) push type double faucet, motor and condenser standing base made by stainless steel of minimum thickness 1.5mm with copper tube condenser not less than 0.50mm and minimum one year replacement warranty (Machine & Compressor) complete all as specified and as directed by Engr-in-Charge. (Make : Model No. SR 40/80 of Sidwal/ Model No. SRA 4080G of USHA or equivalent model No. of make Blue Star/ Voltas)
Supply, Installation, commissioning and testing of voltage stabilizer for automatic operation single phase, wall mounted, copper wounded, air cooled with digital display designed for input variation between 170 volt to 260 volt with output voltage 220 ± 9% volt with calibration accuracy ± 3% with low/ high cutoff, intelligent time delay facility and of capacity 2.0 KVA complete all as specified and directed. (MAKE:-APLEB/ ANDREWYULE /SINETRAC/ VOLINA/VINITEC/IECO/INDIAN TRANSFORMER & ELECTRICALS PVT. LTD.(GURGAON).
Supply, Installation, commissioning and testing of Deep Freezer having hard top double door with locking arrangement, electric driven, single phase, 230 V,50 Hz, AC supply, not less than 320 Ltrs with temperature range (-18°C) working with Non CFC refrigerant, energy efficient compressor, PUF insulation, heavy duty castor wheels and complete all as specified and directed, (Make-VOLTAS, Model No. 5210395 Part No- 320 DD CF/ BLUE STAR of Model No:-CHFDD300DPW or equivalent model of USHA)
Supply, installation, commissioning & testing of BEE 4 star rated frost free Refrigerator double door, electric driven (single phase, 230V, 50 Hz, AC supply) of capacity not less than 308 Ltrs capacity with non CFC refrigerant inverter based compressor complete all as specified and directed (Make-SAMSUNG Model No-RT34M3954U7/ Whirlpool Model No-355ELT4S/ LG Model No:- GLT322RHPN or equivalent model of Voltas/ Videocon)
Supply, Installation, commissioning and testing of Evaporative Cooling System having Turbo Axial Fan for silent, powerful & great air through, Air flow capacity 19000CMH, Max 1.1 KW power consumption & highest effeciency in the industry, made of high quality 100% virgin, UV stabilized, engineering plastic body with 10 years warranty on shell/ cabinet. Rust proof & shock proof body, Maintenance free, long life body span, size 1100mm width x 1100mm depth x 965mm high (43 inch x 43 inch x 38 inch) with four side panels (04 cooling pads) and water tank of capacity 30 litres, electric driven (three phase), 415 volts, 50Hz, AC, fitted with submersible pump of suitable size & capcity, including gun metal float ball valve of complete set of suitable size as per manufaturers design & specifications, six core flexible copper conductor wire of size not less than 1sqmm of required length for connection to LCD panel, Rigid Media/Honeycomb cooling pads on all sides panels, LCD remote control panel with IR remote, IAQi Technology, with silver nano air filtration technology, pre air filter, Auto cleandrain valve, heavy duty industrial grade 100% copper three phase motor of capacity 1.1 KW, 1400RPM complete all as specified and directed, (Make-KAAVA, Model of toofan 19k-3G or equivalent model of make Havells/ USHA/ Khaitan/Sumphony)
Supplying and fixing angle iron and flat iron framed work for mounting of machine, fixing on location as per site requirement made up of suitable size including foundation grouting, welding/soldering and required foundation ground support and fixing on wall/ floor with necessary cement mortar (1:4) to make good the surfaces including applying one coat of red oxide zinc chrome primer and two coats of Synthetic Enamel Paint (1st grade quality) complete all as specified and directed by the Engr-in-Charge. (Make of paint and primer:- ASIAN/ BERGER/ JHONSON & NICHOLSON/ SHALIMAR.)
Supply, Fabrication, Installation, Balancing and Commissioning of Site fabricated GSS sheet metal rectangular ducting of 0.79mm thick (22 gauge) with supports as per IS 655-2010 complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports & mounting ,connecting unit to duct, controller fixation, joint gasket , nut, bolts ,flanges, cleats, etc. complete all as specified and directed by engineer in charge.
Supply & Fixing of aluminium anodised powder coated supply air grills of 1mm thickness, minimum gap between air grills blade of 30mm and width of blade of 30mm horizontally fixed as per manufactureres specification/ design complete all as specified and directed by engineer in charge
Supply and fixing of fire retardant canvas connector cloth (approved by Engr-in-Charge) for connection of cooler with ducts complete all as specified and directed by engineer in charge
Material and labour for AC sub main wiring with four runs of single core 2.5 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC conduit (medium grade) of adequit size with all fittings and accessories surface type (wall/ ceiling) including two runs 1.5 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed.
Material and labour for AC sub main wiring with four runs of single core 4 Sqmm (nominal area) PVC insulated copper conductor FRLS (conforming to IS-694), stranded, unsheathed 1100 volts grade in PVC conduit (medium grade) of adequit size with all fittings and accessories surface type (wall/ Ceiling) including two runs 2.5 Sqmm single core unsheathed stranded copper conductor cable FRLS (conforming to IS-694) as earth wire complete all as specified and as directed. {Note for item No.20 & 21:- (i) Four runs of cable with two runs earth wire shall be measured as one unit length. (ii) PVC conduit shall be measured and paid seperately under relevent items. (iii) Earth wire shall run inside the conduit (iv) Suitable color code of wire must be ensure for phase/ neutral/ earth. (v) (Make of cable:- NICCO / FINOLEX / RR KABEL/ HAVELL'S/ POLYCAB / KEI INDUSTRIES LTD and make of Conduit:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)}
Supply and fixing of 25mm dia (external dia) rigid non-metallic medium grade PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed. (Make:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)}
Supply and fixing of 20mm dia (external dia) rigid non-metallic medium grade PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed. (Make:- FINOLEX / PAYAL/KALINGA/ PRESTO PLAST.)}
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables/ pipes, etc. and not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for sand cushioning to the full width of trenches for protection of cables including spreading watering and consolidation complete all as specified and as directed. (Note:- Only punned down valume of sand to be measured).
Supply and laying bricks, old size, flat, common clay laid in trenches across the trenches/ cable as cable protection complete all as specified and as directed.
Supply and fixing sheet metal enclosure DB TPN 415 volts 4 way single door type, with 200 amps rated bus bar with IP43 protection including one MCB TPN 6 to 10 Amp, 10 kA, C curve, 415 volts complete all as specified and directed by Engr-in-Charge. (Make:- L&T/ Siemens/Legrand/ ABB/ Schneider.)
Supply, installation, commissioning and testing 3 phase, 415 volts, cubical type CPRI approved dust and vermin proof factory made LT panel board outdoor type front opening (double shutter) with locking arrangement of size not less than 600mm x 600mm x 300mm made out of 3.15mm thick CRCA sheet (IS-5039) duly painted with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032) fully compartmentalized design with 4 Nos aluminum busbar suitable for 200Amps current rating, duly color coded, including suitable aluminium earth strips and degree of protection pre-wired with PVC insulated flexible stranded copper conductor FRLS cable confirming IS-694 markes of size not less than 2.5sqmm (busbar to outgoing with 6sqmm) 1100 volts grade, thimbles gland, wall mounted, sloppy headed and supply & comprising of the following including internal pre-wiring complete:- (Make :- L & T/ SEIMENS/ ABB/ LEGRAND/ CROMPTON GREAVES/ C & S ELECTRIC LTD./ SHALABH) INCOMING (i) MCB TPN 16 Amps to 20 Amps, 415 volts, capacity 10 kA, C curve - 01 No. (Make:- L&T/ Siemens/ Legrand/ ABB/ Schneider.) OUTGOING: (i) MCB TPN 6 Amps to 10 Amps,415 volts, 10 kA, 'C' curve - 05 Nos. (Make:- L&T/ Siemens/ Legrand/ ABB/ Schneider.) (Note for item No. 31 & 32:- Contractor shall get the drawings approved before placing the order.)
Cutting openings, through brick walls built in cement mortar for duct passes and other openings or enlarging existing openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and directed by engineer in charge.
Material and labour for forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete with cement mortar 1:4 complete all as specified and directed by engineer in charge.
Supply and fixing rotational moulded polythylene water storage tanks (three layers) of 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by engineer in charge.(MakE:- POLYCON/ SINTEX/ ORIPLAST/ JINDAL)
Cutting of existing 15mm/20mm/25mm/40mm dia steel tubing for alterations or additions (Each cut measured) complete all as specified and as directed.
Spply and fixing galvanised steel tubing 15 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed on wall or floor complete all as specified and as directed. (Make:- JINDAL STEEL/ PRAKASH/ TATA/ OSWAL.)
Spply and fixing galvanised steel tubing 20 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed on wall or floor complete all as specified and as directed. (Make:- JINDAL STEEL/ PRAKASH/ TATA/ OSWAL.)
Spply and fixing galvanised steel tubing 25 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed on wall or floor complete all as specified and as directed. (Make:- JINDAL STEEL/ PRAKASH/ TATA/ OSWAL.)
Spply and fixing galvanised steel tubing 40 mm bore, light grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) fixed on wall or floor complete all as specified and as directed. (Make:- JINDAL STEEL/ PRAKASH/ TATA/ OSWAL.)
Supplying and fixing 15mm bore dia gun metal gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and as directed.(Make:- KIRLOSKAR/ LEADER / VENUS/ ZOLOTO/ AUDCO)
Supplying and fixing 25mm bore dia gun metal gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and as directed.(Make:- KIRLOSKAR/ LEADER / VENUS/ ZOLOTO/ AUDCO)
Supplying and fixing 15mm bore dia PTMT connection pipe of length 450mm including PVC washer on both side complete all as specified and as directed. (Make:- Prayag/ Polytuff)
Supply and fixing PVC flexible drain pipe 32 mm including all fixing accessories complete all as specified and as directed. (Make:- Prayag/ Polytuff)
Material and labour for brick work with best quality locally available bricks, old size, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
Material and labour for rendering 10 mm thick in Cement Mortar (1:6) on fair faces of brick work or concrete surfaces of wall, finished even and smooth with out using extra cement complete all as specified and as directed.
Materials and labour for preparation of new plastered surfaces of wall and applying two coats of white wash complete all as specified and as directed.
Supply and fixing mild steel TMT bar 8mm dia and over, cut to length , bend to shape required, including cranking, bending, hooking end etc. including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Materials and labour for RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings complete all as specified and as directed.
Providing form work to soffits of suspended floor slab not exceeding 200mm thick complete all as specified and as directed.
Material & labour for earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron strip of size 25 x 4mm as earthing lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @150 c/c both ways, one lifting handle made of 10mm dia TMT bar embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick including testing on completion all as specified and as directed. (Note:- Each protection pipe and earth lead upto and including 7.50m length is deemed to be included in unit rate of of this item.)
Supply and laying/ fixing LT XLPE insulated, armoured electric power cable (heavy duty), aluminium stranded conductor, 1100 volts grade of cross sectional area 16 Sq mm, 4 core with suitable size cable glands, crimping type cables lugs etc laid in trenches or on floor/ wall/ poles complete all as specified and as directed. (Make:- ASIAN CABLE/ FINOLEX/ POLYCAB/ KEI INDUSTRIES LTD./ HAVELLS INDIA LTD/ RR KABEL) (Note:- Necessary excavation & earth work will be measured & paid separately.)
RUCHIKA ENGG.WORKS
P S TRADERS
HONEY COLLECTION
Flint India
HVAC Engineering Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .