| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being lowest | |
| 2 | L2₹35.8 L+₹27,870 (0.78%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹38.3 L+₹2.7 L (7.71%)Rejected-Finance | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹39.1 L+₹3.6 L (10.1%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
5 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Vipin Kumar Singh
GE (S) Ahmednagar, Military Engineer Services, Ahmednagar- 414002
Repairs / maintenance of CI/GI/DI water supply distribution system of OTM accn at Aurangabad under GE (S) Ahmednagar
2020_MES_342513_1
8699/E8
Open Tender
Miscellaneous Works
Item Rate
300 days
AURANGABAD
class D cat a (ii)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹76,000
Yes
13 Jun 2020
4 May 2020
8 Jun 2020
4 May 2020
5 Jun 2020
21 May 2020
4 May 2020 - 11 May 2020
60 days
Amount
Excavation in trenches, not exc. 1.5m wide and n.exc 1.5 m in depth, in soft/loose soil for laying pipes, nexc. 10 Sqm on plan and n.exc 1.5 m in depth and getting out spreading etc complete all as specified and directed.
Returing, filling in soil, including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed.
Removing surplus soil to a distance not exc 50 mtr and depositing at a point where directed not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Taking up or down unserviceable CI/DI water mains 80 mm bore including all necessary fittings complete from trenches all as specified and as directed.
All as per serial item No. 4 here-in-before but 100 mm bore pipe.
All as per serial item No. 4 here-in-before but 150 mm bore pipe.
Ductile iron pipes 100 mm bore with spigot and socket ends centrifugally cast class k-9 pressure pipe for water supply ISI marked ( IS 1536 of 2001as amended till date ) suitable for ring tyton joint laid in trenches in proper alignment including testing complete all as directed.
All as per serial item No. 7 here-in-before but 150 mm bore pipe.
Ductile iron fittings such as bends (any type of radius and angle), tapers, increasing , decreasing or double socket etc Tees , Pieces , single branch ,Y junctions , double branch , cross ( all sockets or socket and spigot ) collars , caps and plugs etc complete all as specified and directed.
Taking up or down unserviceable unplasticised PVC / HPDE pipes water tubing 50 mm bore including all fittings complete from walls /floor or trenches all as specified and as directed.
All as per serial item No. 10 here-in-before but 100 mm bore pipe.
All as per serial item No. 10 here-in-before but 110 mm bore pipe.
Taking up or down old rusted and unserviceable GI water tubing 20 mm bore including all fittings complete from walls /floor or trenches all as specified and as directed.
All as per serial item No. 13 here-in-before but 25 mm bore pipe.
All as per serial item No. 13 here-in-before but 40 mm bore pipe.
All as per serial item No. 13 here-in-before but 50 mm bore pipe.
All as per serial item No. 13 here-in-before but 80 mm bore pipe.
All as per serial item No. 13 here-in-before but 100 mm bore pipe.
Galvanised iron pipe 20 mm bore, medium grade, in any length, complete including necessary fittings, laid in trenches/duct, including including jointing and testing complete all as specified and directed. (Excavation and earth work shall be measured and paid for separately).
All as per serial item No. 19 here-in-before but 25 mm bore pipe.
All as per serial item No. 19 here-in-before but 40 mm bore pipe.
All as per serial item No. 19 here-in-before but 50 mm bore pipe.
All as per serial item No. 19 here-in-before but 80 mm bore pipe.
All as per serial item No. 19 here-in-before but 100 mm bore pipe.
Supply only Bleaching powder grade-I, ISI marked packed in 25 Kg Bag complete all as specified and directed.
Galvanised iron pipe 20 mm bore medium grade, in any length, complete including necessary fittings, fixed complete to wall and ceiling or laid in floors including jointing and testing complete all as specified and directed. (Excavation and earth work shall be measured and paid for separately).
All as per serial item No. 26 here-in-before but 25 mm bore pipe.
Gun metal globe or gate valve (ISI marked), with iron wheel head, screwed both ends, suitable for 15 mm bore iron pipe and fixed including testing complete all as specifed and directed.
All as per serial item No. 28 here-in-before but 20 mm bore pipe.
All as per serial item No. 28 here-in-before but 25 mm bore pipe.
All as per serial item No. 28 here-in-before but 40 mm bore pipe.
All as per serial item No. 28 here-in-before but 50 mm bore pipe.
Sluice valve cast iron 80 mm bore long body both ends flanged as per IS-14846 and drilled with stainless steel spindle, iron wheel head and as per pressure rating PN 1.6, Class I, ISI marked alongwith nuts, bolts, washers , gaskets etc. and fixed in position including dismantling and taking out old unserviceable sluice valve from valve chamber / trenches etc complete all as specified and directed.
All as per serial item No. 33 here-in-before but 100 mm bore.
All as per serial item No. 33 here-in-before but 150 mm bore.
All as per serial item No. 33 here-in-before but 200 mm bore.
All as per serial item No. 33 here-in-before but 300 mm bore.
Cast iron non return valve 80 mm bore flanged type of pressure rating PN 1.6, , ISI marked alongwith nuts, bolts, washers, gaskets etc. fixed in position including dismantling and taking out old unserviceable non return valve from valve chamber / trenches etc complete all as specified and directed.
All as per serial item No. 38 here-in-before but 100 mm bore.
All as per serial item No. 38 here-in-before but 150 mm bore.
High density polyethylene pipes of pressure rating PN 10 ,110 mm bore with fusion laid in trenches including jointing and testing complete all as specified and directed.
UPVC pipes 50 mm bore of pressure rating PN 10 laid in trenches including jointing with jointing material/solvent and testing complete all as specified and directed.
All as per serial item No. 42 here-in-before but 100 mm bore pipe.
Cutting existing road/hard standing surfaces to a depth of 60 cm and 50 cm width and getting out for laying under ground pipe including returning filling in, watering well ramming in layers not exceeding 25cm in soil and filling the trench top with 15 cm thick PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) and making good the disturbed surface complete all as specified and directed.
Polyethylene PVC drip irrigation pipe of 15 mm bore including all necessary fittings, laid in trenches/on ground complete all as specified and directed.
Drip irrigation valve piercing type upto 1 mm dia fitted to pipe complete all as specified and directed.
Digital type water level indicator with displaying unit, sensors, suitable for height upto 10 mtr and making electric connection, fixed in repairs/replacement complete all as specified and directed.
Sheet metal enclosure (DB) Single Pole and neutral 2 way, 240 volt including 1 no MCB, SPN 40 Amps complete all as specified and directed.
Mechanical type water level indicator with desplaying scale marked with white reflector tape including replacement of nylon rope, clay weight , brass float valve, pully etc fixed in repairs/replacement complete all as specified and directed.
Cast iron foot valve, 80 mm bore, flanged type PN 1.6, flanged ends with neoprin rubber ball ISI marked alongwith nuts, bolts, washers , gaskets etc. including dismantling and taking out old unserviceable foot valve from valve chamber / trenches etc complete all as specified and directed.
All as per serial item No. 50 here-in-before but 100 mm bore.
All as per serial item No. 50 here-in-before but 150 mm bore.
Dismantaling damaged and broken valve chamber of size 2000 mm x 2000 mm 1800 mm including unserviceable rusted MS cover complete without distrubing the existing pipe lines valves and constructing new valve chamber including necessary earth work in any type of soil ,PCC 1:3:6 in base concrete 100 mm thick ,brick work in CM (1:6) with 10 mm thick plaster internally and 15 mm thick externally in CM (1:4) ,6 mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 mm x 50 mm x 6 mm MS angle complete with two coats of synthetic enamelled paint over a coat of red oxide on all steel work and three coats of white washing on plastered surface of valve chamber complete all as specified and directed.
All as per serial item No. 53 here-in-before but of size 1500 mm x 1500 mm x 1300 mm
All as per serial item No. 53 here-in-before but of size 900 mm x 900 mm x 900 mm
All as per serial item no. 53 here-in-before but of size 450 mm x 450 mm x 450 mm
All as per serial item No. 53 here-in-before but of size 600 mm x 600 mm x 450 mm
Ring tyton joint including rubber ring for CI pipe of 80 mm bore complete all as specified and directed.
Ring tyton joint including rubber ring for CI pipe of 100 mm bore complete all as specified and directed.
Ring tyton joint including rubber ring for CI pipe of 150 mm bore complete all as specified and directed.
Excavation along the CI pipe line of dia 80 mm (main line) between leaking area, burning out the leaking joints and jointing with spun yarn and lead complete and refixing the same with proper lead joint and lead wool including necessary returning filling and well ramming of soil in layers n exc 25cm each complete all as specified and directed.
Excavation along the CI pipe line of dia 100 mm (main line) between leaking area , burning out the leaking joints and jointing with spun yarn and lead complete and refixing the same with proper lead joint and lead wool including necessary returning filling and well ramming of soil in layers n exc 25cm each complete all as specified and directed.
Excavation along the CI pipe line of dia 150 mm (main line) between leaking area , burning out the leaking joints and jointing with spun yarn and lead complete and refixing the same with proper lead joint and lead wool including necessary returning filling and well ramming of soil in layers n exc 25cm each complete all as specified and directed.
Excavation along the DI/GI/UPVC/HDPE pipe line of dia 80 mm ( main line ) between leaking area , and taking out old unserviceable MS clamp and supply & jointing properly new clamp of same size, type including nuts, bolts and rubber packing complete including necessary returning filling and well ramming in layers n exc 25 cm each complete all as specified and directed.
Excavation along CI/DI/GI/UPVC/HDPE pipe line of dia 100 mm ( main line ) between leaking area , and taking out old unserviceable MS clamp and supply & jointing properly new clamp of same size, type including nuts, bolts and rubber packing complete including necessary returning filling and well ramming in layers n exc 25 cm each complete all as specified and directed.
Excavation along DI/HDPE pipe line of dia 150 mm ( main line ) between leaking area , and taking out old unserviceable MS clamp and supply & jointing properly new clamp of same size, type including nuts, bolts and rubber packing complete including necessary returning filling and well ramming in layers n exc 25 cm each complete all as specified and directed.
Disconnecting electric supply old unserviceable induction motor & pump of capacity 15 HP, taking out and transportaion to workshop and refixing the same after repair/replacement of worn out parts such as motor and pump bearings, fan blade & rewinding the motor with suitable gauge of super enamelled copper wire of 'F' class insulation , warnishing, heating & reassembling & servicing of pumps, refixing with motor & testing reassembled motor & pump for satisfactory completion & testing at site complete all as specified and directed.
Cast iron body water meter 300 mm dia suitable for discharge flow of 1400cum /hr of working pressure rating PN 1.6 duly tested from manufacturer/any govt authorised agencies , fixed in replacement complete all as specified and directed. Make - CAPSTAIN.
Disconnecting electric supply and taking out old unserviceable submersible sewage pump set 20HP, 3 phase electric motor from sewage underground sump by means of chain pully and trasporting to authorised workshop for repair and rewinding the motor with super enamelled insulated copper wire of existing gauge including insulated packing liquid compound, differential oil 4.5 ltrs, repalcement of oil seal and motor/pump bearing, replacement/repair of motor and pump shaft made out of high quality Stainless steel and reassembling the motor and installing back the same at its original position, aligning, testing and commissioning on full load for 8 hrs continuous running complete all as specified & directed.
Suction sweeper brush 4' long of make Modiguard or equivalent fixed in replacement complete all as specified and directed.
Online pressure pump pressure setting relay connected accessories of Make Grandfoss fixed in replacement complete all as specified and directed.
Fabrication of stainless steel ladder / part of ladder for OH reservoirs/ having staging up to 24 mtrs or underground sumps, with stainless steel (Flat, Angle, Sheet, Rail or round hollow) sections (Fe 316 high Quality grade) including necessary welding, grinding, bracing, revetting etc, including necessary arrangement for grouting/fixing on wall/floor complete all as specified & directed.
Chamber cover fabricated out of MS angle sections (Fe 410-W, Gde-E 250, Quality A) of 40 mm X 40 mm X 6 mm in framework embeded in PCC coping, 3 mm thick MS sheet cover fixed on flat iron 40 mm X 6 mm all around and diagonally and hinged to the angle iron frame work with locking arragement with lifting handle including necessary welding, grinding, bracing, revetting etc, preparing the metallic surface, applying two coats of super enameled anti corrosive paint of approved colour over a coat of zinc chromate primer complete all as specified & directed.
Cutting / trimming / and clearing the vegetation around the OH Resrvoirs / underground sump or inside areas of installation complex, levelling the cleaned area, disposing off dirt off the premises complete all as specified and directed.
Disconnect electric supply, dismantling coupling and removing 7.5 HP compressor, shifting to local workshop for repair / servicing, opening up the compressor unit, dismantling and removing damaged piston, piston connecting rod, rings etc and replace with new one, reconditioning / welding / filling / grinding / lathework to shaft of the compressor unit, supply & replace suitable size bearing of make : SKF - 2Nos, drain out the old compressor oil, cleaning the oil chamber thoroughly by removing the sludges from the oil sump, replace with new compressor oil of specified gravity - 4 Litres, supply & replacement air filters of suitable size - 2Nos, reassemling with new gasket set, coupling, aligning, supply and replacement worn out V - belts ( B-72) of make : Fenner - 3Nos, transporting the repaired compressor back to the original location, reinstalling, testing & commissioning complete all as specified & directed.
Disconnecting electric connection, taking out and transporting to workshop old unserviceable induction motor of capacity 40 HP for repair/replacement, opening up the motor and rewinding with suitable gauge of super enamelled copper wire of 'F' class insulation , warnishing heating & replacement of worn out parts such as motor bearings, fan blade,reassembling after painting by preparing the surface, scrapping the old painting and removing the grease, oil, dirt etc, filling the cavities, spray painting with two coats of super enameled anti corrosive paint of approved colour, over a coat of primer transporting the repaired motor back to the original location, reinstalling, testing & commissioning complete all as specified & directed.
Disconnecting electric connection, taking out and transporting to workshop old unserviceable induction motor of capacity 25 HP for repair/replacement, opening up the motor and rewinding with suitable gauge of super enamelled copper wire of 'F' class insulation , warnishing heating & replacement of worn out parts such as motor bearings, fan blade,reassembling after painting by preparing the surface, scrapping the old painting and removing the grease, oil, dirt etc, filling the cavities, spray painting with two coats of super enameled anti corrosive paint of approved colour, over a coat of primer transporting the repaired motor back to the original location, reinstalling, testing & commissioning complete all as specified & directed.
Disconnecting the electric connection, taking out and transporting to workshop old unserviceable induction motor of capacity 15 HP for repair/replacement, opening up the motor and rewinding with suitable gauge of super enamelled copper wire of 'F' class insulation , warnishing heating & replacement of worn out parts such as motor bearings, fan blade,reassembling after painting by preparing the surface, scrapping the old painting and removing the grease, oil, dirt etc, filling the cavities, spray painting with two coats of super enameled anti corrosive paint of approved colour, over a coat of primer transporting the repaired motor back to the original location, reinstalling, testing & commissioning complete all as specified & directed.
Disconnecting electric connection, taking out and transporting to workshop old unserviceable pump of capacity 40 HP for repair/replacement of worn out parts & the repair work shall includes replacement of both end pump bearings, glang packing, oil seal, including machining of shaft at lathe machine, greasing etc reassembling and transporting back to site after satisfactory completion of repair work, reinstalling & testing complete all as specified and directed. Note :- Any nut/bolts/ studs and packing required shall deemed to be included in the rates quoted by the contractor.
Disconnecting electric connection, taking out and transporting to workshop old unserviceable pump of capacity 25 HP for repair/replacement of worn out parts & the repair work shall includes replacement of both end pump bearings, glang packing, oil seal, including machining of shaft at lathe machine, greasing etc reassembling and transporting back to site after satisfactory completion of repair work, reinstalling & testing complete all as specified and directed. Note :- Any nut/bolts/ studs and packing required shall deemed to be included in the rates quoted by the contractor.
Taking out and transportation to workshop of required old UNSV pump of capacity 25/15 HP for repair/replacement of worn out parts & reassembling after satisfactory completion of repair work & testing at site . the repair work shall includes replacement of both end pump bearings, glang packing, oil seal, including machining of shaft at lathe machine, greasing complete and testing for smooth running at pump house complete all as specified and directed. Note - Any nut/bolts/ studs and packing required shall deemed to be included in the rates quoted by the contractor.
Opening cast iron sluice valve 300 mm bore in position and taking out unserviceable stainless steel/brass spindle and checknuts & transporting to lathe machine for repairing, machining, grinding, threading and refixing the same in position after replacement of unserviceable parts including greasing and gland packing and testing complete all as specified and directed.
Opening cast iron sluice valve 150 mm bore in position and taking out unserviceable stainless steel/brass spindle and checknuts & transporting to lathe machine for repairing, machining, grinding, threading and refixing the same in position after replacement of unserviceable parts including greasing and gland packing and testing complete all as specified and directed.
Opening cast iron sluice valve 100 mm bore in position and taking out unserviceable stainless steel/brass spindle and checknuts & transporting to lathe machine for repairing, machining, grinding, threading and refixing the same in position after replacement of unserviceable parts including greasing and gland packing and testing complete all as specified and directed.
Mechanical joint with 2 Nos CI/DI sockets, 1 Nos of CI/DI collar and 2 Nos styrene betadine rubber galket alongwith nut bolts and washer incl cuting CI/DI pipe for insertion of mechanical joint in posotion for 80mm bore pipe, as in repairs completed all as specified and directed.
All as per serial item No. 85 here-in-before but for size 100 mm bore.
All as per serial item No. 85 here-in-before but for size 150 mm bore.
m/s shivam tools and equipment
M/s S.R lahoti
BHAVIN INFRA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .