Tender Value
₹15.0 L
EMD Value
₹29,940
Closing Date
7 Oct 2023, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Dharampur Bharari
Interlinking of source from percolation well to LWSS Sohar
2023_HPIPH_79612_1
7834-84 dated 29.09.2023
Open Tender
Pipe Laying Works
Item Rate
30 days
Sandhole
Please refer Tender documents.
7 documents required · 7 mandatory
₹400
Executive Engineer
₹29,940
10 Oct 2023
2 Oct 2023
9 Oct 2023
2 Oct 2023
7 Oct 2023
2 Oct 2023
Amount
Excavation in foundation and trenches etc. (for pipe and pits) up to all depth and in all kind of soil such as pick work, jumper work, saturated soil including bailing or pumping out water, blasting in soft / hard rock, chiseling / wedging out of same where blasting is prohibited in all lead and lift including trimming and dressing of side, leveling of beds to correct grade including shoring, strutting, planking timbering and dewatering where ever required, stacking the usable and unusable and un-usable materials/soil separately and after laying, jointing and testing of pipes, returning the useful soil trenches in 15 cm layers by ramming and watering and then disposing of all surplus excavated soil/unusable materials as directed with in all leads/lifts including restoration of unmetered/unmetered surfaces to its original conditions and including cost of diversion of traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects within all leads and lift as per direction of Engineer-in-charge.
Providing circumferencial Butt welded joints by electrical arc welding to following dia API/GMS/MSERW Pipes welded in requisite number of weld runs including thread cutting so as to achieve the minimum effective throat thickness of weld conforming to IS 816-1969 specifications, by using welding electrodes of 2.5mm to 6.3mm of Advani Oerlikon (Adore)- CITOJET/ESAB make, conforming to IS 814-1991, at site of work complete in all respects, including manual/mechanical handling of pipes in all leads and lifts to the entire satisfaction of Engineer-in-Charge.
80 mm dia.
Laying, jointing and testing in trenches (to level or grade) of GMS pipes of below diametre conforming to IS 1239-1990 (Part - I) with latest upto date amendments having minimum wall thickness as per class of pipe at both ends according to relevant BIS i/c all kind of leads and lifts, short pieces, bends tee and other specials etc. made from parent tubes and welded with butt welding as applicable for the perticular reach as per site conditions.The laying of pipes conform to IS 5822-1994 and as per CPHEEO manual and will include all operations such as cutting, welding and jointing including flushing, cleaning and hydraulic testing complete in all respect and as per direction of Engineer-in-charge. (Labour Rate)
80 mm dia (Medium Class)
Supply of Submersible clear water Pump Set of KSB/Kalama/SU/Johnstion make comprising to latest relevant B.I.S. code. The Pump should be fitted with free flow mpeller of suitable alloys as per BIS 8034-376 with upto date ammendments suitable for clear water having greased packed bearing and shaft with wound stator on motor side and with shaft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) of required HP, RPM 2900/1450 of reputed make conforming to Kirloskar/Crompton/NGEF specification latest with upto amendments. The pump shall be fitted with a divice to take up expension of water with the heating of motor. The squirrel cage electric induction motor (Water-proof type of suitable H.P. motor of same make as that of pump confcorming to BIS-9287-1979 latest with upto date ammendments totally dust and water proof for submersible duty isolated from the pump by intermedaite casing with double mechanical seal in oil chamber and greased packed lubricated bearing and providing with stainless thurst bearing plate to with stand the vertical load with minimum wear and tear.It should also be fitted with a divice to take up expansion of water with the heating of motor. The pump should we include water level guards, erection clamps, cable clips and depth guage etc and suitable for operation on data given below:-
SITE CONDITIONS:- Total Head 107.00 mtrs Discharge required 4.75 LPS each set. No. of Pump required. 2Nos 1set act as stand bye. Low water level 580 m. Submersgence level 583 m. Location of the site of installation of machinery: The site is located at Bank of Beas River a distance of Km from Dharampur. The Altitude of :- The Altitude of place is 800 mtrs above MSL Type of Current:- AC three phase supply with RateVoltage:- 415+/-10% Charactristics of water a) Ambient b) Turbidity NTU NTU c) Hardness 260 Mg/Ltrs d) PH Value 5.00 HP -- e)Total Solid Mg/Lts)PH Value -- f) Other -- Length of R/main 1500 mtrs Dia of Rising main 80 mm dia. No of working hours. 8 Hours. Limit of Pump (-) 15% (+) 10% of R. M.P. of Pumping 2900 RPM (or to be specified by the tenderer) Test run 16 Hours continueously for 7 days.
Providing and fixing of Oil immersed Star Delta Starter for above pump set of standard make Such as L&T/Havella/MEI conforming to BIS: 8544-1979 latest with upto date ammendments for squirrel cage/slipring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag, under voltage release with intial oil filling complete in all respect as per direction and to the entire satisfaction of Engineer-in-charge.
Supply of MS. Angle iron steel sheet 16 SWG fabricated floor mounting closed (Almirah type) switch board comprising and capable of mounting the following accessories and with all internal electric connections, duly painted. The drawing of panel board shall be subject to approval of Engineer-in-Charge.
ICTP switches with HRC fuses of Havells/L&T/standard /cromption make for required motor of 32 Amp. capacity and conforming to IS: 4064 (part - II)1978 latest with upto date amendments.
Bus bar chamber having 3 copper bars of suitable rating for full length of 3 phases and one bar of half the rating of full length for neutral conforming to IS: 8084 –1976 and 11354-1985 read with 5578-1985 all latest with upto date amendmentsof suitable rating.
MCB/OCB of suitable capacity of Havells/standard/MDS/Jyoti/Kilburn make to feed motors offered by the tenderer conforming to IS: 2516 (Part - II ) 1985 latest with upto date amendments with neutral linked under voltage release.
3 phase indicator lamps complete with toggle switches for individual motors conforming ti IS 3452 part I & II latest with up to date amendments of 15 watts.
50 mm dial Hour run meter of CEE / NEE make of suitable range as per relevant IS specifications.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, heigh voltage & overloading & phase voltage difference.
Change over switch of reputed make and suitable capacity.
Single phase preventer of reputed make & suitable capacity.
Providing and fixing double flanged Cast Iron sluice valve having size one step higher than delivery of pump of Kirloskar/Leader make conforming to IS:14846/2000 with up to date amendment as per Class PN-1.00 to withstand in normal seat pressure of 10.20 Kg/cm² including welding with M.S. Flanges table-17 as per IS 6392-1971 including carriage in all leads and lifts as per direction and to the entire satisfaction of Engineer-in-Charge.
Providing and fixing double flange cast iron swing check type reflux valve having by pass arrangement of suitable size of Leader / Kriloskar/ Kartar make conforming to BS 780-1984 with upto date amendments as per class PN-1.00 to withstand a seat pressure of 10.20 Kg / cm2 , Flange Table-17 as per direction and to the entire satisfaction of Engineer-in-Charge.
Providing and fixing double flange cast iron swing check type reflux valve having by pass arrangement and size equal to dia of rising main of Leader / Kriloskar/ Kartar make conforming to BS 780-1984 with upto date amendments as per class PN-1.00 to withstand a seat pressure of 10.20 Kg / cm2 , Flange Table-17 as per direction and to the entire satisfaction of Engineer-in-Charge.
Providing and laying suitable size copper PVC insulated armoured power 3.5 core cable conforming to BIS 1554 (part-I) –1988 of latest with upto date amendments L&T/Finolex make form meter of HPSEB- to CB and form CB to Bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories such as thimbles, flexible pipe solder, nuts and bolts, cable glands, etc. laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer. Supply side Suitable sizes.
Supply of PVC joint less flat water proof cable as per IS: 694-1990 latest with upto date amendments suitable for the pump sets offered from CB to motor including all other electrical equipment / accessories such as thimbles, flexible pipes solder, nuts and bolts, cable glands etc laid in pipes of trenches under floor. The type, size and make will be subject to approval of HPSEB authorities & in case of non acceptance by HPSEB authorities it shall have to be replaced by tender.
Providing and laying double loop earthing with G.I. wire & G.I plate complete with material such as charcoal, common salt, GI. Pipes, thimbles, nuts and bolts, digging of pits, GI. Wiring and aluminum strips of required capacity conforming to BIS: 3043-1987 latest with upto date amendments for above motors and other electrical equipment’s.
Supply of floor/wall mounted power factor shunt capacitor conforming to BIS: 2834-1986 latest with upto date amendments L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of suitable rating each including cable of siemens/Gloster/ICC make form bus bar chamber to capacitor and also including L&T/LK/Kilburn make ICTP switches conforming to IS – 4064 (Part - II) 1978 or latest with HRC fuses (range to be specified by the tendrerer).
Supply of standard make circular dial pressure gauge 0-16 kg/cm2 range of feibig make with all accessories such s stop cock, copper tubing etc, conforming to IS: 3624-1987 latest with upto date amendments.
Providing and laying delivery pipe of required dia. and common header one step higher than delevery pipe Heavy class as per IS:-1239-2004 Part-I jointed with MS flanges of table -5 as per IS: 6392-1971 (upto a length of 10 mtrs ) including rappers, flanges, rubber gaskets, nuts and bolts and specials upto 5 mtrs away from the outer wall of pump houses/well as per layout drawings approved by Engineer-in-Charge.
Providing and supplying of 1x3x6 mm² copper PVC insulated single core cable conforming to BIS-694 or latest with up to date ammendments of Havells/Fenolex make including all other electrical equipment alongwith allied accessories complete as per direction and to the entire satisfaction of Engineer-in-Charge.
M/s Sharma Light house
akhil thakur govt contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .