| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1ST LOWEST₹2.2 LAccepted-AOC RASIKPUR LAYEK PARA BURDWAN P O BURDWAN DIST PURBA BARDHAMAN PIN 713101 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713101 | ₹2.2 L | 1ST LOWEST | Accepted-AOC FIRST LOWEST |
| 2 | 2ND LOWEST₹2.2 L+₹2,991.32 (1.35%)Rejected-Finance 767 BIJOY NAGAR PURBA BARDHAMAN 713101 | PURBA BARDHAMAN | PURBA BARDHAMAN | WEST BENGAL | 713101 | ₹2.2 L+₹2,991.32 (1.35%) | 2ND LOWEST | Rejected-Finance NOT THE FIRST LOWEST |
| 3 | 3RD LOWEST₹2.2 L+₹775.53 (0.35%)Rejected-Finance | ₹2.2 L+₹775.53 (0.35%) | 3RD LOWEST | Rejected-Finance NOT THE FIRST LOWEST |
Tender Value
₹2.2 L
EMD Value
₹4,432
Closing Date
16 Jan 2026, 11:30 amClosed
The Assistant Engineer Burdwan Sub Div.-II SS, PWD
Office of The Assistant Engineer, Burdwan Sub Division II, Social Sector, P. W. Dte. Jagatberh, Surya Nagar, PO Sripally, Dist - Purba Bardhaman, Pin 713103.
Construction of Ramp with Shed for easy patient movement at the back side of Fluoroscope Machine Room of G plus7 building within the main campus of Burdwan Hospital in the district of Purba Bardhaman.
2025_WBPWD_978785_2
WBPWD/AE/BSD-II/SS/ NIT-14eOF2025-26
Open Tender
CIVIL WORKS
Percentage
15 days
Purba Bardhaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹4,432
Yes
O/O The Assistant Engineer Burdwan Sub Div.-II SS,
15 Sept 2026
24 Dec 2025
19 Jan 2026
24 Dec 2025
16 Jan 2026
30 Dec 2025
30 Dec 2025
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) (B) Do - by fine sand
Brick work with 1st class bricks in cement mortar (1:4 ) (a) In foundation and plinth
Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes a) In ground floor
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with uired bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge. a ) In ground Floor :-
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if essary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as er drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel JSW/JSPL/SHYAM/ SRMB/BMASL/ELECROSTEEL/SSL
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic dhesive & grout materials etc. Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic dhesive & grout materials etc. (b) Area of each tile above 0.09 Sq.m (i) Coloured decorative
Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer's specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor) a) In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength > 1200 N
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of oncrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian a) In Ground Floor :---
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark (vii) 100mm. X 58mm. X 1.90mm
ii) Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (c) 300 mm long.
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35 mm thick shutters (single leaf)
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately) (b) 40mm X 6mm, 200mm Length
Anodised aluminium decorative handle (hexagonal / fluted) of approed quality fitted and fixed complete. ( i) 150mm plate x 10mm dia rod x 12mm hexagonal/fluted.
M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof. i) For Roof truss works a) Span up to 12 Mtr Ramp Shed
Supplying, fitting & fixing single skin colour coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BTM (Base metal thickness) 0.50 TCT (Total coated thickness excluding paint), G550 (min 550 yteild stenght ) of Zincalume metalic (ISI 5965) with high solar reflactance (SRI) value for better cooling as per thermatect technology , 1000-1015 effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with suitable square fluting in the pan and the end rib shall have anti-capillary groove and return leg. The steel sheet shallbe fastened with 40 micron zinc coated, hex head.Self drilling screw as per IS 3566-2002Class 3 fastener. The base steel shall be coated with zinc-aluminium alloy zincalume (AZ150)(i.e.55% Al, 43.4%Zinc, 1.6% Si) minimum of 150gm/m2 coating total on both sides, pre-painted with colorbond XRB (exterior, roofing, walling ) paint system of 35 micron super Durable Polyester paint (SDP) with stable inorganic pigment with no lead contents confirming ISI5965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genuinity of the material. (i) In Roof: a) With 0.5 mm thick sheet
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. n the surface, if necessary : (b) On steel or other metal surface : (iv) Two coats (with any shade except white) With super gloss (hi-gloss) -
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC a) One coat a) in ground floor
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer b) Premium 100% Acrylic Emulsion
Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete. Hydraulic door closer of approved quality as per I.S.I. standard fitted and fixed complete.
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge
Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed. (c) Upto 50 users:- (ii) Beyond a lead of 150 metre and outside the Municipal limit
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. disposal of the same outside the compound as directed. a) In ground floor including roof.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_2386814.xls
BOQ • 0.32 MB
2911ii.pdf
Tender Documents • 0.50 MB
FormVI.pdf
Tender Documents • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .