Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹40.5 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹40.5 L+₹6,725 (0.17%)Rejected-Finance VILLAGE BAHADURPUR FAKIRAN PATIALA | L-2 | Rejected-Finance L-2 |
Tender Value
₹40.5 L
EMD Value
₹81,093
Closing Date
12 Dec 2019, 3:00 pmClosed
Er. Narinder Pal Singh Office of EE WSSD Gurdaspur
Office of EE WSSD Gurdaspur
AUGMENTATION OF WATER SUPPLY SCHEME JOHAL NANGAL BLOCK DHARIWAL DISTT GURDASPUR UNDER NABARD XXIII
2019_WSS_39871_1
Johal Nangal 2019
Open Tender
Civil Works
Item Wise
180 days
In Village Johal Nangal
Please refer Tender documents.
2 documents required · 2 mandatory
₹100
TIA
₹81,093
1 Feb 2020
1 Nov 2019
13 Dec 2019
1 Nov 2019
12 Dec 2019
1 Nov 2019
Amount
Water Supply Component
Boring with 250mm i/d casing pipe for tubewell in al soils except ordinary hard rocks requiring balsting including removing the casing pipe after the tube well is lowered and tested equipement as required such as hand boring machine and its accessory, transportation to site and vice versa etc complete in all respect.
Boring with 250mm i/d housing pipe
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
200mm nominal diameter (weight 41.6 kg per metre, 8.0 mm thickness.
150mm nominal diameter (weight 21.6 kg per metre) 5.4 mm thickness.
Supplying, fixing & lowering of Stainless Steel Cage type wire wound screen as per IS:8110-2000 or latest ISI marked, duly welded with suitable grade S.S. welding electrode to lower the strainer into tubewell bore.
150mm steel strainer (slot size 0.15mm) 5.00 mm thickness
Supplying, fixing and lowering of stainless steel socket as per IS 8110-2000 or latest, ISI marked duly welded with suitable grade ss welding electrode to lower the strainer into tubewell bore complete in all respect.
150mm Internal diameter
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect.
200mm internal diameter
150mm internal diameter
Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Supplying at site Wooden Box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Supplying & Fixing of bail plug of M.S pipe complete with inverted U-hook attched to the bottom plug complete in all respect.
150mm internal diameter (weight 21.6 kg per metre) 5.4 mm thickness
Providing and fixising MS Taper/Reducer made out of 6mm Thick MS Sheet Complete in all respect
Reducer 200mmx150mm
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect.
200mm internal diameter
Testing of Water Sample for heavy metal from approved laboratory (Toxic material sucha as arsenic, lead, mercury, presticide etc.)
Development and Stabilizing of the tubwell with air compressor of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI
Development and Stabilizing of the tubwell with submersible pump of required capacity as directed by the engineer-in- charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Collection of water sample from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
PUMP CHAMBER
Construction of Pump Chamber size 3.05 m x 3.70m without gravel pit but including electric wiring as per DWSS standard design and analysis complete in all respects. Extra for provision for Sanitary Latrine in pump chamber for foundation and plinth of WC rooms including flooring ,PVC pipes , Junction Box , 1 No. Leach Pit , Super structure WC room etc.
PUMPING MACHINERY
Providing & installing, testing & commisioning of 1 no electrically driven Submersible Pump set of KSB or equivalent make of capable of delivering 4.60 lps against a head 49 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter,Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps, Kit-Kat etc. including M.S column Pipe of IS 1239-2004 medium class suitable size 65mm & length 30mtr (in 3.00 mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 80 mtr length and 2.50 mm2 size as per IS694-1990 reaffirmed 2000 complete in all respects
Rate of Motor with Pump Rate of Motor with Pump 4.60 lps discharge 49 mtr head
Panel Board
Submersible cable Size 2.50mm2
Column Pipe (G.I) 65mm
C.I.FITTING INSIDE PUMP CHAMBER
Providing & Installing 100 mm dia delivery main (from Tube-well to duck foot bend including cost of C.I.D/F Pipes, D/F Sluice Valves, D/F Non Return Valve & Specials as C.I. Bends, Tail Piece Tees, Pressure gauge, Air Valve,,V notch haudi etc. inside the Pump chamber as per DWSS standard design and analysis complete in all respects. (Annexure-3) As per IS1536-2001 & 1538-1993 reaffirmed 1999 and electro steel Casting/Kesoram pipe make).
Disinfection Unit:
Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 leter of bleaching powder solution/ sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter. (Milton roy or Equivalent make)
RCC OHSR
Constructing one No. of 50 KL 50000 ltr litres Capacity with sill level not less than 17 m height upto FSL 20 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing D.I. K-9 D/F expansion joints latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and C.I/D.I. D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow DI double flanged pressure pipes DI K-9 horizontally cast in sand moulds as per IS 8329-2000 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. In case the safe bearing capacity of sail is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling within lead of 5 km, including overflow scower haudi complete in all respects.
D.I RISING MAIN (K-9)
Providing, stringing out, cutting, jointing & testing out ISI marked D.I K-9 pipe ( S&S) & Specials as per 8329 & laying the same in trenches to correct alignment and gradients, jointed with rubber titen joint fitted complete including all cartage & including cost of excavation complete in all respects as per DWSS Standard analysis.
100mm i/d (Mechanical)
Sluice Valve & Sluice Valve Chambers
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS1410) and Bronze(gunmetal) working parts sluice valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
Consturction of masonary Sluice valve chamber excluding Sluice valve cover as per standard design & drawings of pubic health department.
(a) Size 0.9 m. x 0.9 m.
DEVELOPMENT OF WATER WORKS SITE.
Providing & fixing 1.2mtr high fencing around the head works site with 1.65 meter post, placed every 2.5 meters apart, embedded in cement concrete blocks and every tenth post to be strutted with three rows of G.I. Barbed wire weighing 9.34 Kg per 100 meters (minimum) and fixing with GI staples tied to 6mm bar nib, with binding wire or by providing cut, including drilling holes in the post, including cost of posts, winding wire, strutted earth work in the post & aluminum painting complete in all respects as per DWSS standard Drawing and analysis.
Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects.
Providing & fixing D-Hook complete with MS Bolts size 300mm x 18mm as per DWSS standard Drawing and analysis.
Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per DWSS standard Drawing & Analysis.
Construction of masonry gate pillar including cost of MS Steel Gate size 1.22 m x 1.37 m as per DWSS standard Drawing and analysis.
Construction of Foot Path with masonry toe wall & earth filling and Cement Concrete 1:8:16 with 40 mm gauge stone aggregate, 40 mm thick cement concrete topping 1:2:4, inside water works as per DWSS standard Drawing and analysis.
Providing & fixing MS sign Board as per DWSS standard design and analysis.
Providing, laying, Fixing, jointing, cutting & testing of uPVC Pipes & Specials (6 kg./cm2) including cost of excavation complete in all respects as per ISI-4985 standard analysis. (Supreme /Finolex/Prince/Jain/Kissan Make or equivalent make)
Excavation with JCB
uPVC Pipe 63 mm o/d
uPVC Pipe 90 mm o/d
uPVC Pipe 110 mm o/d
Excavation with Manually
uPVC Pipe 63 mm o/d
uPVC Pipe 90 mm o/d
uPVC Pipe 110 mm o/d
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS1410) and Bronze(gunmetal) working parts sluice valves ISI marked 14846-2000 including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
Consturction of masonary Sluice valve chamber excluding Sluice valve cover as per standard design & drawings of pubic health department.
(a) Size 0.6 m. x 0.6 m.
Dismantling and restoration brick paving complete in all respect as per DWSS standard approved analysis.
PVC Pipe 63mm o/d
Dismantling and restoration of Cement Concrete Road complete in all respect as per DWSS standard approved analysis.
Contractor shall be quote rates only for dismantling of mettaled road & back filling with excavated earth fully compacted the restoration of the mettaled road to its original condition will be done by the concerned department i.e. PWD (B&R) PMB/Panchayati Raj)
Household water connection ISI Marked,
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing GI pipe lines 15mm i/d=2.50 mtr B- Class,( Above GL), Prov. & fixing MDPE pipe 15mm i/d with specials 2.00 Mtr (Below GL) including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3" i/d clamp with c.i bib cock 15mm i/d as per IS:210 with stainless steel spindle of approved make
Environment Provision
Making lawns including ploughing & dragging with Sohaga breaking of clods, removal of earth rubbish dressing & supplying doob grass roots and planting at 15 cm, apart including supplying and spreading of farm yard manure @ 0.18cum per 100 sqm & loosening.
Supplying and planting permanent tress including digging of earth pits size 75cmx75cmx75cm deep refilling the excavated earth with manure supplied @ 0.113 cum each and watering supplying through tractor tanker. (Trees like Neem, Ashoka, Dake, Arjun etc)
Planting ground cover plants including digging and refilling of beds with excavated soil and FYM, Fertilizer and insecticides, planting of saplings at 30cm distance from plant to plant and row, providing and fixing brick tiles edging.
Planting , flower beds including digging and refilling of beds with excavated soil and FYM, fertilizer and insecticides, planting of sapling at 30 cm distance from plant to plant and row to row.
Providing for one way stand post with Khura complete in all respects.
parwinder singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .