Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC 88 197 B CHAMAN GANJ KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.3 L+₹45,103.10 (1.03%)Rejected-Finance 39 W 1 ASHOK VIHAR SAKET NAGAR KANPUR 208014 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208014 | L2 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
20 Jul 2020, 6:00 pmClosed
GE I KANPUR
GE I KANPUR
SPECIAL REPAIR OF SEMINAR ROOM AT CQA PP IN DGQA COMPLEX PROVN OF EXHAUST FANS IN CERTAIN MARRIED ACCN AT KANPUR CANTT PROVN OF LOW SECURITY WALL AT COD ESTATE AND PROVN OF SEPTIC TANK AND SOAKAGE WELL AT BLDG NO P117 HARDING ROAD II AT KANPUR
2020_MES_327275_3
GE(I)/KAN/T-47 OF 2019-20
Open Tender
Civil Works
Item Rate
180 days
Kanpur Cantt
Class D category a i
7 documents required · 7 mandatory
₹500
GE I KANPUR
₹89,000
Yes
18 Aug 2020
27 Jun 2020
22 Jul 2020
27 Jun 2020
20 Jul 2020
8 Jul 2020
Amount
BnR Schedule
Taking down cement plaster on brick or stone wall/ceiling etc including racking out joints hacking for key scrubbing down with water etc complete, all as directed by Engineer –in-charge.
Dismantling of brick work built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facing etc.complete all as specified and directed.
Demolition of reinforced cement concrete of roofs, floors (other than ground floors) beams staircases landing chajjas and similar suspended work etc complete all as specified and directed.
Demolition of cement concrete etc(unreinforced) in ground floor and paving n exc 15 cm thick (below or above ground level) complete all as specified and directed.
M&L Brick work with fly ash brick straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for 15 mm thick rendering in cement mortar 1:6 on fair faces of concrete or brick surface finished even and fair complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of concrete or brick surface finished even and fair mixed with water proofing compound @3% by weight of cement or as per manufacturer instruction complete all as specified and directed.Note: WPC shall be measured and paid separately.
M&L for applying two coats of white wall care putty on newly plastered or undecorated surface internal/external surface of building to prepare the surface smooth, to make the edges sharp and proper in alignment including rubbing with sand paper to achieve a smooth surface and sharp straight edges ,upto the height of double storey building .all as specified and directed.
M&L for applying two coats of oil bound distemper over a coat of primer including preparation of surfaces etc complete all as specified and directed.
M&L for applying two coats of weather coat exterior emultion paint over a coat of primer including preparation of surfaces etc complete all as specified and directed.
Material and labour for light colour vitrified tiles min.10mm thick(square/ rectangular), light shade , area of each tiles not exceeding 0.36 sqm area, as in flooring set and jointed in neat cement slurry and pointed in coloured cement to match, .laid over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. Note: Colour, design and pattern shall be approved by GE.
All as per item no 12 above but dark colour vitrified tiles.
Dismantling of floor hearth or wall tiling including cement mortar bedding (but not backing) and clearing rubbish off the premise complete all as specified and directed.
M&L for 7 to 8 mm thick non skid ceramic coloured tiles (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm area as in floors etc; laid jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles over and including 15 mm thick screed bed in CM ( 1:4 ) complete all as specified and directed. Note: Colour, design and pattern shall be approved by GE.
M&L for glazed ceramic coloured tiles 300x450x 7 to 8 mm thick on vertical surfaces such as skiting/dado set and jointed in neat cement slurry and pointed in colour cement to match the shade tile over and inclduing 10mm thick rendering in CM (1:4) complete all as specified and directed. Note: Colour, design and pattern shall be approved by GE.
M&L for powder coated aluminium glazed window shutters with frame openable using 100 x 45 x 2.00mm thick aluminium sec for frame & section for shutter 45 x 44.45 x 1.90 mm thick incl 5mm thick glass sheet with rubber beading clip, hinges, handles, tower bolts etc complete complete all as specified.
M&L for powder coated aluminium grill of mesh size 65 x 75mm of 6mm dia of aluminium bar fixed with 'Y' or 'H' aluminium sec all as specified
M & L for providing PVC false ceiling consisting of 600mm x 600mm, 5 mm thick plain PVC Sheet of density 600kg/cum used as a panel insert in a frame work made using anodised aluminium 'T' section of size 25mmx25mm of 19 gauge or 1 mm thick i a square pattern of grid sizes of 600x600mm. The aluminium frame work shall be supported from the ceiling with the help of G.I. wire 4mm dia with suspenders of required size to maintain proper level etc. The aluminium frame work shall supported on side wall with the use of aluminium "L" section of size 25x25 mm angles etc complete all as specified and directed by Engineer in charge and as per manufacturer's specification. Make : Rajshri / Everest/Sintex as approved by GE(I).
Dismantling wall or ceiling boards (fibre, pulp insulation etc) any thickness & at any height complete all as specified and directed.
M & L Solid PVC wall lining complete consisting of 5 mm thick single side prelaminated PVC sheet used inclusive of solvent cement and fixing at site on PVC frame including taking down existing lining work complete all as per manufacturers specification and product drawing shown in SSR part II all as directed.
M&L 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing all as per manufacturers specification and product drawing shown in SSR part II all as directed.
Dismantiling of AC sheet (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantiling of AC ridge any type any size situated over AC sheet roofing complete all as specified and directed.
M&L pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strenth of 550 Mpa (total mass coating 150gms/sqm) (both side) as in roof covering/ clading to wall fixed fixed with self tapping screws of reqd size and dia with head having matching colour complete all as specified and as directed. Make: (a) Lloyd Insulation (b) Tata bluescope steel building solutions Ltd.(c) Prestar Infrastructure Project Ltd (d) Colour Roof India Ltd.(CRIL) (e) M/s Matco Roof PvtLltd. (f) Ispat Industries Ltd (g) Everest Industries
All as per item no 25 above but Plain steel sheet (factory moulded shape as per site requirement) as in ridge, hips, valley gutter, drip and straight flashing fixed with self tapping screws of reqd size and dia with head having matching colour complete all as specified and as directed.
S & F rolled mild steel in structural work like roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed .
M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section, in any position in framed work complete all as specified and directed.
Removal of dismantled/demolished unserviceable material to a distance exc 1500 metre but not exc 2000 metre from the starting point to outside DGQA complex including rubbish off the area complete all as specified and directed.
M & L for 75 mm thick PCC type C-1, 1:3:6 (20mm graded stone aggregate) for plinth protection surface finished even and smooth without using extra cement complete all as specified and directed.
S&F for venetion blind for windows 100mm wide vertical type of fabric as approved including all fittings and accesories of make VISTA or equivalent complete all specified and directed.
Taking up or down 15 mm bore GI pipe and connections, from trenches/walls and removal from site, complete all as specified and directed.
S&F 15mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete and all as specified and directed. Make : TATA/Jindal/ Prakash Surya as approved by GE.
S&F in repair Vitreous china suatting pan of Orrissa pattern size 580x440mm white with integral foot rest including P trap or S trap front ot back, PCC bedding 1:5:10 type E-2 using 40 mm graded brick aggregate complete all as directed. Make : Hindware/ Cera/ Parryware as approved by GE.
S&F in repair Pillar tap fancy type cast copper alloy with capstan heads, chromium plated screwed down high pressure, with or without lettered 'HOT or cold with long screwed shanks and fly nuts screwed shanks and fly nuts screwed for irion pipe and fixed complete all as specified and as directed. Make : L&K / Plumber / Jaquar/Prayag/Marc as approved by GE.
S&F in repair vitreous china wash basin white flat back size 550x400mm but exclusive taps, wastes, chain and plug and porcelain stopper but including cutting for and pinning in ends of brackets or erecting stand, waste pipe including brackets fixed in repairs complete all as specified and directed. Make : Hindware/ Cera/ Parryware as approved by GE.
S&F in repair 10 ltrs capacity PVC low level valve less flushing cistern (white) syphonic action type with all fittings such as inlet ball valve, float, and handle 32 mm dia polythene high density flush pipe and connected to squat pattern.Make : Hindware/ Cera/ Parryware/ Prayag as approved by GE.
S&F in repair HDPE triple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable size and 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod with high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. Make: Sintex/Dhara/JS Polyplast
S & F 15mm bore stop valves,fancy type cast copper alloy chromium plated with long shank and cup (concealed type) screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. Make : L&K / Plumber / Jaquar/Prayag/Marc as approved by GE.
S&F in repair 15 mm dia bib tap fancy type CP cast copper alloy with crutch or butter fly handle screwed down, screwed for iron pipe complete all as specified and directed. Make : Hindware / L&K / Plumber / Jaquar/Prayag as approved by GE.
S&F in repair 15 mm bore angle cock, cast copper alloy cromium plated, screwed down, high pressure, with capstan screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. Make : Hindware / L&K / Plumber / Jaquar/ Prayag as approved by GE.
S&F 15mm bore PVC connection 450mm long heavy duty with brass fly nut and warsher complete and all as specified and directed
Taking down chowkhats with shutters (without taking off shutters from the frame) area not exc 1.5 sqm each complete all as specified and directed.
Taking down chowkhat or frames with shutter (without taking of shutters from the frame) exc 1.5 sqm n exc 4 sqm each complete all as specified and directed
Taking down aluminium shutter of cupboards any description complete all as specified and directed
Taking down aluminium partition any description complete all as specified and directed
M& L for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded but Single Side Prelam PVC sheet used instead of Plain colour PVC sheet and stile & rails having one side feathered edge and on other side 10mm 90 degree bent edge 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
M&L for solid PVC door frame ( single rebated) of size 50 mmx 47 mm made out of 5 mm plain colour PVC Sheet with homogenous fine cellular structure having smmoth outer integral skin with suitable metal stifner and fixed with 100x8 sheet metal CSK (copper screws) screws complete all specified and as shown drawing.
M&L 2nd class hardwood as in plain , solid, straight chowkhats and frames , wrought , framed , rebated on the solid, rounded or chamfered, put together with glue pinned joints complete all as specified
S & F of 32 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.Note : Manufacturer test certificate and PVrs shall be submitted by contractor before claiming payment against this item.
M&L for preparing new or previously untreated surfaces of wood or wood based materials of any description exc 10 cm width or girth when unconnected with other painting or when painted in different tint.and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F of 100 mm size PVC butt hinges of Make: Prayag or equivalent complete all as specified and directed.
S&F of 150 mm size PVC handle of Make: Prayag or equivalent complete all as specified and directed.
S&F of 150 mm size PVC tower bolt of Make: Prayag or equivalent complete all as specified and directed.
S&F MS butt hinges 100mm medium weight, cold rolled and fixed
S&F of 150 mm long barrel tower bolt aluminium anodised of extruded section and fixed complete all as specified and directed.
S&F of 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F of 300 mm long aluminium anodised sliding door bolt with hasp and staple and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed.
S&F HDPE triple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable size and 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod with high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. Make: Sintex/Dhara/JS Polyplast
Excavating in trenches, n. exc 1.5m wide and n exc 1.5m in depth for foundation etc or for shafts, wells, cesspits manholes pier holes, under ground cable/pole fondation/ water supply pipe line and getting out including forming bottom surface to required level or slope complete all as specified and directed by Engineer-in- Charge.
Returning filling in with approved excavated soil including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removal of excavated material (soil) n. exc 50m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in fdn/mass concrete complete all as directed by Engineer –in-charge
Use and waste Formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams sides and soffits (if any ) of foundation and plinth beams and similar work vertical or to batter all as specified and directed..
Use and waste formwork to sides of roof, pillars, posts, struts, piers, columns and stanchions rough finished surfaces of conrete square, rectangular, polygaonal or flat surfaces of roof complete all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc rough finished surfaces of conrete flat complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed..
S&F mild steel TMT bars 6 mm to 8 mm dia cut to length, bent to shape required, including, rings cranking, stirrups, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed..
M&L for Reinforced cement concrete M- 25 (design mix) (20 mm graded stone aggregates) as in foundations, including rafts, footings, foundations beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete all as specified and directed .
M & L for Reinforced cement concrete M- 25 (design mix) (20 mm graded stone aggregate) as in columns, pillars, piers etc as all specified and directed.
M & L for Reinforced cement concrete M- 25 (design mix) (20 mm graded stone aggregate) as in beams, cantilevers, lintel etc as all specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of concrete or brick surface finished even and fair without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on other than fair faces of concrete or brick surface finished even and fair complete all as specified and directed.
M&L two coat of cement base paint over a coat of cement primer on newly plastered surface on wall including preparation of surface complete all as specified and directed.
S&F MS work as in post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc ) inclu. all necessary drilling , bolting or riveting etc and similar work confirming to Fe-290-0 gde E-165 complete all as specified.
S & F Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed.
S&F 110mm dia PVC(SWR) pipes single soketed in any length with rubber ring jointed laid in trenches/under floor complete all as specified
Supply only WPC compound (ISI marked)
M&L for RCC hume pipe Septic tank of 10 users as per Drg no TD/A/157 sheet 1/1 (Details of the Hume pipe Septic tank for 10 to 100 Users) designed to carry sewage and sullage water complete all as specified and as directed by Engineer in Charge.
Construction of brick soakage wells of size 3.0 m X 4.5 m deep (Effective) as per TD 576 sht 1/2 and 2/2 complete all as specified and as directed by Engineer in charge.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone agg for concrete bed to drain pipe incl packing under and haunching against the sides after they are laid and tested for 150mm bore RCC NP-2 pipe complete all as specified and as directed.
S&F 150mm bore RCC Hume pipe class NP-2 laid in trenches and jointed in CM 1:1 complete all as specified and as directed.
M&L Brick work with sub class B bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:4 complete all as specified and as directed.
M&L for plain cement concrete type B0 (1:2:4 ) using 12.5 mm graded stone aggregate as in coping, benching finished even and smooth using extra cement including necessary formwork complete all as specified and directed.
Cutting into existing manhole for connecting new drain making good to pipe and rendering, cutting out existing benching for and forming branch channel (half round) in cement concrete 1:2:4 type B1 using 20mm graded stone agg smooth finished and reforming benching as required for 150mm bore pipe complete all as directed.
M&L for Precast RCC 1:2:4 type B-1 as in cover slab for manhooles and drain etc complete all as specified and directed.
S&F mild steel TMT bars 6mm to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed..
Conducting the field investigation (soil testing) (No of boring holes 04 nos , depth of bore holes required 10 RM Each hole) for the following buildings: (i) 300 Mtr Baffle range near existing butt in depression area. (a) Side walls SW (b) Baffle wall The process of field investigation (soil testing)shall be as under: (A) (a) Boring of 150mm dia holes through overburden soil including shifting bore hole. (b) Carrying out standard penetration test of every 1.50 meter interval and at change of strata. (c) Collection of disturbed samples at every 1.50 meter interval including handling and transporting complete to the laboratory from 0.00 meter to 10.00 meter) (d) Collection of undisturbed soil samples at 2.50 mtr interval & transporting including handling complete to the laboratory. From 0.00 mtr to 10.00) (B) Conducting laboratory test on undisturbed and disturbed soil samples :- (a) Natural moisture contents as per IS : 2720 (Part III) - 1973. (b) Tri-axial compression test /direct shear test as per IS : 2720 (Part XIII)-1972 (c) Consolidation test as per IS: 2720 (Part XV) -1965 (d) Mechanical sieve analysis as per IS : 2720n (Part IV) - 1965 (e) Atterberg limit test as per IS: 2720(Part V) -1970 (f) Particle size analysis hydrometer test as per IS : 2720 (Part IV)-1965 (g) Dry and bulk density test as per IS: 2720 (Part XXVII)-1980 (h) Specific gravity test as per IS: 2720 (Part III) - 1980 (C) Submission of test report in quadruplicate including recommendation of depth, type and safe allowable bearing capacity for the foundation. (D) The work shall be carried out from an agency having minimum five years experience in the respective field and should have conducted at least five soil explorations and report shall be vetted by Govt Engineering college/IIT/HBTI before submission to this office.
EnM Schedule
Taking down carefully unserviceable of aluminium point wiring complete except for ceiling or where not feasible fan / plug / bell but including fittings such as switches, ceiling rose, pendents, regulator etc. and making good disturbed surface to match with the existing surface of roof / wall / floor by applying putty, plaster of paris etc. and applying finishing coat of existing treatment complete all as specified and directed.
M&L for point wiring with PVC (FRLS) insulated and unsheathed cable 1.5 Sqmm (Nominal area) multi-stranded copper conductor single core with proper colour coding including PVC conduit medium grade of 25 mm dia concealed in walls and surface on ceiling with and including pressed steel concealed terminal boxes of appropriate size and top cover 2.5-3.0 mm thick of plastic laminated sheet ISI marked of desired colour of make : Super Hylam, painting terminal boxes inside and outside with a coat red oxidé primer complete with all accessories with and including 1.5 Sqmm PVC insulated and unsheathed green colour multi-stranded copper conductor cable to common earth and connected to earth dolly complete all as specified and directed for the following points:-Note: Cutting chases in walls required for concealed conduit wiring shall be finished with cement mortar 1:4 and, surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor. Make of cable : Finolex/Polycab/ Havells/Plaza/Grandlay/ Gloster, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
(a) One light/fan/bell/exhaust fan point controlled by one switch.
(b) One 3 Pin socket outlet 5 Amps on Independent board.
(c) One 3 Pin socket outlet 5 Amps on same board.
All as per item No. 92 here in before but for one power point, independent point with 2.5 Sqmm (Nominal area) PVC insulated and unsheathed copper conductor (FRLS) multi-stranded single core cable including green colour earth wire of size 1.50 Sqmm PVC insulated and unsheathed copper conductor (FRLS) multi stranded single core cable.
S&F of switch piano flush type 5/6 Amps single pole one way complete all as specified and directed.
S&F of switch piano flush type 15/16 Amps 240 Volts single pole one way complete all as specified and directed.
S&F of socket outlet flush type, 5 pin 6 Amps, 240 Volts complete all as specified and directed.
S&F of socket outlet 2 in 1, 6 pin 5 & 15 Amps, 240 Volts complete all as specified and directed.
S&F of ceiling rose surface bakelite of three terminals 240 Volts complete all as specified and directed.Make of item No 94 to 98 : Anchor / CONA (WAWA) / Havells / Legrand.
Taking down unserviceable sub main wiring of aluminium any type with earth wire and making good disturbed surfaces of wall / floor or roof etc and applying plaster,putty and applying paint to match with existing specification of wall complete all as specified and directed
M & L for sub main wiring with two single core of 4 sqmm copper conductor FRLS, PVC insulated and unsheathed multi-stranded cable including PVC conduit medium grade of 25 mm dia, concealed in / surface on walls for sub main connection and 4 sqmm FRLS, PVC insulated and unsheathed multi-stranded green colour copper conductor cable as an earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/Polycab/ Havells/Plaza/Grandlay/ Gloster, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
M & L for sub main wiring with two single core of 10 sqmm copper conductor FRLS, PVC insulated and unsheathed multi-stranded cable including PVC conduit medium grade of 25 mm dia, concealed in / surface on walls for sub main connection and 6 sqmm FRLS, PVC insulated and unsheathed multi-stranded green colour copper conductor cable as an earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/Polycab/ Havells/Plaza/Grandlay/ Gloster, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
S&F vertical distribution board TPN 4 way with including MCCB 100 A, Four pole 16 KA as incomer, shrouded neutral bar & pan assembly, IP-43 protection, double door with IP-54, IK-09 protection and flexible connecting link and MCB SP 240 Volts, 'C' curve 10 KA (5-32A)- 12 Nos as out going complete all as specified and directed. Make : Schneider Cat Part No. A9HVD04M or equialent in Legrand cat part no 507750 / HAVELLS/INDO ASIAN/ABB. Note : MCBs shall be measured separately.
S&F of MCB single pole, 6 to 32 Amps, 240 Volts, 10 KA complete all as specified and directed. Make: Legrand/Havells/Indo Asian/Schneider/ABB as approved by GE.
Supply and fix single pole and neutral enclosue with a top pin and earth plug and socket complete with one SPN MCB 25 Amp 240 Volt Make : Havells Cat Part No. DHDMCDPO253025 or equivalent make of Legrand/Siemens/ABB/Indo Asian
Supply and fixing of LED 31/34 watts with burning 50000 hrs and efficacy require 100 lumens / watt indoor recessed mounting lumninaries with all accessories suitable for armstong / grid / POP ceiling complete with electronic driver & high brightness all as specified and directed by the Engr-in-Charge. Make : Wipro cat part no CRCO10R038HP57SLAB/ Philips Cat Part No. RC380B LED34S-6500 L60W60 PSU OD S1 /Havells cat part no LHECDNLQL1W034 as approved by GE(I)..
Supply and install of Wall mounted fan heavy duty 230 V, AC single phase, Oscillating Fan, 450 mm sweep suitable for wall mounting complete with fixing arrangement including suitable fastners etc, electric connection and writting MES No in black synthetic enamel paint / engraving tool etc in wall all as specified and directed. Make : Havells / Crompton / Usha / Bajaj/ Almonard / Orient as approved by GE(I).
M&L for earthing with galvanised steel earth plate electrode 600x600x6mm thick buried directly in the ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below the ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washers of galvanised or steel all as specified or shown in electrical plate of SSR (Part-l) including necessary excavation, earth work, GI pipe 15 mm dia light grade for protection of galvanised iron earthing wire, GI pipe 20 mm dia light grade watering pipe etc. including concrete chamber of PCC 1:2:4 type B-2 (using 40mm graded stone aggregate), copping in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate), internal surface of concrete chamber shall be plastered with 12 mm thick cement mortar 1:4 and 50 mm thick RCC cover in pre-cast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) duly reinforced with 8 mm dia1or bar @ 80 mm c/c both ways and charcoal dust, common salt etc. including testing after completion complete all as specified and directed.
Disconnecting,dismantling and taking up or down old/unserviceable/cracked GI tubing with fittings and removal from the site of Size 25 mm bore. Note: Excavation and earth work will be measured and paid separately under relevant items.
Supply & Laying, jointing and leakage testing GI tubing medium grade 25 mm bore with all fittings such as bend, tee, elbow, union, reducer etc, laid in trenches/floor/walls and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 using 20 mm graded stone aggregate/ plastering in CM 1:4 and applying finishing coat of existing treatment) complete all as specified and as directed at site.:- Make: Tata/Jindal/Prakash Surya as approved by GE(I) Notes :(i) Excavation & earth work shall be measured & paid seperately.
S & F stop valve 25mm dia, gun metal iron, screwed down, high pressure with crutch or butterfly handle, screwed for iron pipe or for ferrule ISI marked complete
Supply and install of Exhaust fan 230 V, AC single phase of size 380 mm sweep, 900 RPM metal body complete with fixing arrangement, electric connection grouting of nuts, bolts, in wall, electric connection and writting MES No in black synthetic enamel paint / engraving tool etc all as specified and directed. Make : Turboforce of Havells / Crompton / Almonard / Orient as approved by GE.
S&F metal body louver shutter suitable to fit in outside of hole for exhaust fan of size 380mm sweep complete all as speciifed and directed by Engineer in Charge
M & L for making hole at brick / stone masonry wall for fixing the Exhaust fan 380 mm sweep and making good the disturbed portion match with the existing surface
N. K. ASSOCIATES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .