Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 CrAccepted-AOC | ₹24.2 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹24.9 CrRejected-AOC | ₹24.9 Cr | L2 | Rejected-AOC OTHER THAN LOWEST |
| 3 | L3₹24.9 CrRejected-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹24.9 Cr | L3 | Rejected-AOC OTHER THAN LOWEST |
| 4 | L4₹24.9 CrRejected-AOC WZ 487 2 MS BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | ₹24.9 Cr | L4 | Rejected-AOC OTHER THAN LOWEST |
| 5 | L5₹25.1 CrRejected-AOC | ₹25.1 Cr | L5 | Rejected-AOC OTHER THAN LOWEST |
Tender Value
₹15.6 Cr
EMD Value
₹11.1 L
Closing Date
15 Oct 2022, 6:00 pmClosed
CHIEF ENGINEER CHANDIGARH ZONE
CHIEF ENGINEER CHANDIGARH ZONE N AREA OLD AIRPORT ROAD CHANDIGARH 160003
CA NO CE CHZ PAT T 18 2021 22 PROVISION OF CENTRAL AMMENITIES INCLUDING GYMNASIUM SWIMMING POOL SHOPPING CENTRE AND OTHER ALLIED SPORTS INFRASTRUCTURE AT PATIALA
2022_MES_516622_3
CE CHZ/PAT/T-18/2021-22
Open Tender
Civil Works
750 days
PATIALA
REFER TENDER DETAILS
7 documents required · 7 mandatory
₹3,000
GE SOUTH PATIALA
₹11.1 L
Yes
31 Aug 2023
19 Sept 2022
17 Oct 2022
19 Sept 2022
15 Oct 2022
3 Oct 2022
Amount
Schedule 'A'Section-I (BUILDING / STRUCTURE Works)
Lump sum price worked out by the Contractor for "Buildings/Structure Works " as listed in Sch 'A' Sec I
Schedule 'A'Section-II (SITE CLEARANCE, DEVELOPMENT AND EARTH WORKS)
Lump sum price worked out by the Contractor for "Site Clearance , Development And Earth Works " as listed in Sch 'A' Sec II
Schedule 'A'Section-III (INTERNAL ELECTRIFICATION WORKS)
Lump sum price worked out by the Contractor for "Internal Electrification Works" as listed in Sch 'A' Sec III
Schedule 'A'Section-IV (INTERNAL WATER SUPPLY AND SUMMER APPLIANCES WORKS)
Lump sum price worked out by the Contractor for "Internal water supply and summer appliances works" as listed in Sch 'A' Sec IV
Schedule 'A'Section-V (SEWAGE DISPOSAL WORKS)
Lump sum price worked out by the Contractor for "Sewage Disposal Works" as listed in Sch 'A' Sec V
Schedule 'A'Section-VI (AREA DRAINAGE WORKS)
Lump sum price worked out by the Contractor for "Area Drainage Works" as listed in Sch 'A' Sec VI
Schedule 'A'Section-VII (ROAD, PATH,HARDSTANDING AND CULVERTS WORKS)
Lump sum price worked out by the Contractor for "Road, Path,Hardstanding and Culverts works " as listed in Sch 'A' Sec VII
Schedule 'A'Section-VIII (SECURITY FENCING,SECURITY WALL AND GATE WORKS)
Lump sum price worked out by the Contractor for "Security Fencing, Security Wall and Gate Works" as listed in Sch 'A' Sec VIII
Schedule 'A'Section-IX (EXTERNAL WATER SUPPLY WORKS)
Lump sum price worked out by the Contractor for "External Water Supply Works" as listed in Sch 'A' Sec IX
Schedule 'A'Section-X (EXTERNAL ELECTRIC SUPPLY WORKS)
Lump sum price worked out by the Contractor for "External Electric Supply Works" as listed in Sch 'A' Sec X
Schedule 'A'Section-XI (ARBORICULTURE WORKS)
Lump sum price worked out by the Contractor for "Arboriculture works" as listed in Sch 'A' Sec XI
Schedule 'A'Section-XII (RAIN WATER HARVESTING WORKS)
Lump sum price worked out by the Contractor for "Rain Water Harvesting works" as listed in Sch 'A' Sec XII
Schedule 'A'Section-XIII (LIGHTENING PROTECTION WORKS)
Lump sum price worked out by the Contractor for "Lightening Protection Works" as listed in Sch 'A' Sec XIII
Schedule 'A'Section-XIV (BADMINTON COURT WORKS)
Lump sum price worked out by the Contractor for "Badminton Court works" as listed in Sch 'A' Sec XIV
Schedule 'A'Section-XV(Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
INTERNAL ELECTRIC SUPPLY WORKS
Point wiring (using approved colour coding as per IS) with 1100 volts grade, stranded copper conductor 1.5 Sqmm (nominal area), FRLSH,PVC insulated and unsheathed cable IS 694 marked TEC and FIA approved and including PVC concealed conduit(thickness not less than 1.5mm and 20 m dia) and its fittings ISI marked PVC junction boxes terminated in sunken/pressed metal flush box for mounting of modular switches/sockets/fan regulators and white cover plate with frame, also including FRLSH PVC insulated unsheathed stranded copper conductor 1.5 Sqmm (nominal area) 1100 volts grade, copper conductor cable as earth continuity conductor to common earth and connected to earth dolly including necessary cutting/chases complete all as specified and directed by Engineer-in-Charge for the following (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) ( the cost of Modular cover plate and metal flush boxes is included in the unit rate quoted for this item) Note :Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost.:-
(a) One light point controlled by one switch or one (Ceiling/ Wall/ Exhaust) fan point controlled by one switch and regulator and one bell point controlled by one bell push
(b) One 3 pin 6 Amps socket outlet on independent board
(c ) One 3 pin 6 Amps socket outlet on same board
All as per item Ser No 31 hereinabove but one light point controlled by two 2 way switches.
Point wiring (using approved colour coding as per IS) with 1100 volts grade, stranded copper conductor 2.5 Sqmm (nominal area), FRLSH,PVC insulated and unsheathed cable IS 694 marked TEC and FIA approved and including PVC concealed conduit(thickness not less than 1.5mm and 20 m dia) and its fittings ISI marked PVC junction boxes terminated in sunken/pressed metal flush box for mounting of modular switches/sockets/fan regulators and white cover plate with frame, also including FRLSH PVC insulated unsheathed stranded copper conductor 2.5 Sqmm (nominal area) 1100 volts grade, copper conductor cable as earth continuity conductor to common earth and connected to earth dolly including necessary cutting/chases complete all as specified and directed by Engineer-in-Charge for the following (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) ( the cost of Modular cover plate and metal flush boxes is included in the unit rate quoted for this item) Note :Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost for one 3 pin 5/15 Amp socket outlet.
Sub main wiring using approved colour coding as per IS with five (four for main & one for earth) single core, PVC insulated, unsheathed FRLSH multistranded copper conductor cables of size 10.00 sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board complete all as specified and directed. Note: (i) Five runs each of one RM of 10.00 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Sub-main wiring with 2 single core FRLSH insulated and unsheathed cable with stranded copper conductor of 2.5 Sq mm drawing into & including heavy grade PVC Concealed conduit ISI marked of suitable size with all accessories and one additional 1 run of wire of 2.5 Sq mm but green in colour for earth DBs and boxes with proper thimbles,including necessary cutting/chases complete all as specified and directed. Note: (i) Three runs each of one RM of 2.5 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Sub-main wiring with 2 single core FRLSH insulated and unsheathed cable with stranded copper conductor of 4.0 Sq mm drawing into & including heavy grade PVC Concealed conduit ISI marked of suitable size with all accessories and one additional 1 run of wire of 4.0 Sq mm but green in colour for earth DBs and boxes with proper thimbles,including necessary cutting/chases complete all as specified and directed. Note: (i) Three runs each of one RM of 4.0 sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Sub main wiring using approved colour coding as per IS with three (two for main & one for earth) single core, PVC insulated, unsheathed FRLSH multistrand copper conductor cables of size 6 Sqmm (nominal area) 1100 volts grade, drawn through & including heavy duty PVC concealed conduit of suitable bore and connected to main board complete all as specified and as directed. Note: Three runs each of one RM of 6.0 Sqmm cable together with conduit shall be considered as 1 running meter for payment purpose.
Modular Blank plate 1 module suitable for modular switch board complete all as specified and as directed
Epoxy power coated MCCB distribution distribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified. (Note :- MCCB will be measured and paid under seperate item) (i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCBs in DBs without any extra cost
Energy saving LED light fitting, 1 x20 watt, 230 volts, decorative ultra slim linear LED lighting fixture with extruded ploycarbonate, enviormental friendly, energy efficient ready to use pack, with electronic driver and with best quality diffuser high lumen output, 2.5 KV voltage surge protection, PF0.98, THD<10% suitable for surface/ pendant mounting complete with all accessories including and connecting of with twin core of PVCinsulated 0.75 Sqmm copper conductor cable complete all as specified.
Energy saving LED porch light fitting, 1x 12 watt, 230 volts, Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, enviormental friendly, energy efficient ready to use pack with electronic driver and with best quality diffuser high lumen output, 2.5 KV voltage surge protection, PF 0.98, THD <10% suitable for surface/ pendant mounting complete with all accessories including and connecting of with twin core of PVC insulated 0.75 Sqmm copper conductor cable complete all as specified.
Surface mounted LED down light in engineering plastic housing with clear prismatic diffuser with LED lamp 12 watt white light, complete all as specified and directed
Sheet metal enclosure MCB DB, 12 ways SPN, 240 volts,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
Sheet metal enclosure MCB DB, 8 ways SPN, 240 volts,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
Sheet metal enclosure MCB DB, 4 ways SPN, 240 volts,IP-43 protection, double door type grouting in wall in CM, flush mounted complete with 200 Amp rated bus bar complete all as specified and as directed.
MCB SP, 230volt , 50 Hzs, 6 to 32 A, 10 KA , "B" series complete all as specified and directed.
MCB SPN, B Curve as incommer, 220 volt , 50 Hzs, 32 Amps, 10 KA ,complete all as specified and directed.
MCB TPN as incommer, 440 volt , 50 Hzs, 63 Amps, 10 KA , complete all as specified and directed.
MCCB 100 Amps , AC 4 pole 415 Volt 25 KA Breaking Capacity as per IEC 60947-2 adjustable thermal magnetic trip unit range 400 Amp, Ics = 100% with extended rotary handle complete all as specified and directed.
Sheet metal enclosure with DB's suitable for MCBs of triple pole and neutral 4 way, 415 volt, double dooe type with 200 amp rated bus bar double door type with one incoming and 12 outgoing having IP 54 protection Note : Connections of the MCB's shall be done with appropriate size of brass/ Copper thimble complete all as specified and directed.
Ceiling fan AC single phase 240 Volt 50 Hz of size 1200 mm sweep complete in white colour having service value more than or equal to 4.5 with canopy and hanging rod with all accessories incl nuts,bolts,clamps etc, complete all as specified and directed
Exhaust fan 300 mm sweep metal body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 900 rpm complete with louvers for wall mounting incl grouting,making hole in the wall and holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to exhaust fan incl cutting of hole of required size for fixing of the exhaust fan complete all as specified and directed
Exhaust fan 150 mm sweep metal body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 900 rpm complete with louvers for wall mounting incl grouting,making hole in the wall and holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to exhaust fan incl cutting of hole of required size for fixing of the exhaust fan complete all as specified and directed
Exhaust fan 450 mm sweep metal body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 900 rpm complete with louvers for wall mounting incl grouting,making hole in the wall and holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to exhaust fan incl cutting of hole of required size for fixing of the exhaust fan complete all as specified and directed
Air circulator wall mounted fan 600 mm sweep metal body, heavy duty, Single phase AC 230/240V, with energy efficient motor, pre lubricated double ball bearing, speed 1440 rpm complete for wall mounting incl grouting,making hole in the wall and holding down bolts, nuts, washers and provision of flexible copper conductor cable 3 core from ceiling rose to Air circulator complete all as specified and directed
LED bulb 10 watt 230 volts AC 50 Hz Retrofit B22 base for lamp holder complete all as specified and directed.
Surface mounted wall Mirror LED light Compact & sturdy 9 watt LED decorative fixture with anti glare polycarbonate diffuser, multi purpose lighting solution & applications .all accessories & fixtures, internally prewired and connecting by providing copper flexible wire 23/.0076 mm twin core upto fitting, complete in all respects,
ROAD, PATH,HARDSTANDING AND CULVERTS
Providing, Laying, compaction of granular sub-base by providing close graded Material conforming to specifications i.e Grading II, conforming to Clause 401 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller of capacity 8 to 12 tonne to achieve the desired density, 150 mm thick compacted thickness, complete all as specified and directed by Engr-in-Charge.
Providing, Laying. compaction of Wet Mix Macadam conforming to Clause 406 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) , 250 mm thick (compacted thickness,125 mm thick in two separate layers) with mechanically crushed graded stone aggregates and granular material (size range 53 mm to 0.075 mm ), grading of aggregates as per Table 400-13 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) ,including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 12 tonne capacity to achieve the desired density , required gradient and camber etc., complete all as specified and directed by Engineer-in-Charge. NOTES: 1. The WMM shall be laid in two layers i.e each layer of 125 mm thick (compacted thickness). 2. For payment purpose,both layers shall be considered as one unit.
Preparation of un-surfaced Wet Mix macadam (WMM) surfaces by sweeping clean by power broom or mechanical sweepers and removing completely all loose material and other foreign material and finally fanning the cleaned surface with air compressors to remove all loose dirt etc. and applying evenly a priming coat on un-surfaced wet mix macadam surfaces conforming to Clause 502 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion SS1 grade,confirming to IS 8887(latest edition) @ 7.5 kg per 10 sq metres using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed by Engineer-in-Charge.
Providing, laying & compaction of Bituminous Macadam (BM) 50 mm Compacted thickness conforming to Clause 504 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), using mechanically crushed stone aggregates and granual material etc. of grading II as per Table 500-7 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), premixed with bituminous binder, Bitumen grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density complete all as specified and directed by Engineer-in-Charge. Notes : (i) The contractor shall quote the rate against Item considering 3.5% VG-30 bitumen content. Mix Design for bituminous macadam shall be got designed from NIT/ CTL/ Govt Engg College and shall be got approved from GE in writing well before commencement of work without any financial effect to the department. Also the bitumen content shall not be less than 3.4% by weight of total mix as per clause 504.2.4 of MoRT&H specifications (Fifth Revision). (ii) If qty of binder contents is less than the qty as specified in respective items of BOQ, it shall be adjusted at Rs 62 per litre for paving bitumenand if qty of binder contents is more than the qty as specified in respective items of BOQ no adjustment shall be made.
Preparation of bituminous surfaces and applying evenly a Tack coat conforming to Clause 503 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion RS1 grade,confirming to IS 8887(latest edition) @ 2.5 kg per 10 sq metres using using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed by Engineer-in-Charge.
Providing and laying 30 mm thick (consolidated thickness) Bituminous Concrete (BC) layer conforming to clause 507 of MoRT&H specifications for road and bridge work (Fifth Revision) including cost of coarse aggregates, fine aggregates, filler, 5.5% binder (paving Bitumen grade VG-30) content by weight of total mix and crushed aggregates of grading 2, Anti Stripping Agent, Warm Mix Additives (quantity, quality and grade as per the approved Job Mix Formula) etc, cleaning and pre-heating of the mineral aggregate, filler & bitumen to the specific temperature, thoroughly mixing with binder of specified bitumen content, Anti Stripping Agent, Warm Mix Additives as per mix design in Hot Mix Plant (Batch Type) of 100-120 TPH capacity, carrying the hot mixed materials by means of tipper, trucks, or any other approved and suitable arrangements, laying the hot premixed materials over the prepared surface by means of paver finisher including manual operation as and when required for proper grade, level and camber thorough rolling with power roller 8 to 12 tonnes smooth wheeled, vibratory and tandem roller with necessary hand packing and pinning to give an even surface, including running expense of all plants and machineries, inclusive of proper traffic control during laying to the satisfaction of Engineer-in-Charge, required quality control tests at required interval etc complete in all respects complete all as specified and directed by Engr-in-Charge.
60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, walkway, parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand & filling the joints after laying complete all as specified and as directed.
2.5 mm thick painting to road surfaces as in lines,dashes,arrows,letters,Zebra crossing etc on roads,pavements and like with hot applied thermoplastic road marking inclusive type I reflectorising glass beads as per table 800-3, 800-4 of MORTH applied in uniform thickness and spread uniformly with reflectorising glass beads type-II @ 500 gms per sqm with a road marking machine as per IRC:35,in white or golden yellow colour with traffic diversion arrangemets if required, complete all as specified and as directed.
Road stud / cat eye ABS material body of size 100x100x20mm with two highly reflective reflectors fitted in the body, fixed with MS pin & approved epoxy adhesive as per manufacturer instruction on road , of colour as directed complete all as specified and as directed.
INTERNAL WATER SUPPLY WORKS
Wall mixer cast copper alloy with bend pipe for overhead shower for 'Hot or Cold' screwed down for 15mm bore iron pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
Central hole basin mixer cast copper alloy with 450mm braided connection pipe ( without pop up ) , fancy type chromium plated screwed down, high pressure, with or without lettered 'Hot or Cold' screwed for 15mm bore iron pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
Sink mixer ( wall mounted ) cast copper alloy with 150mm long swivel spout , connecting legs and wall flanges , fancy type chromium plated screwed down, high pressure, with or without lettered 'Hot or Cold' screwed for 15mm bore iron pipe or brass ferrule complete all as specified and directed by Engineer-in-Charge.
SUMMER APPLIANCES
Supply and installation of Desert cooler electric driven (single phase) with outer body made of PGI (Plain Galvanised Iron) sheet not less than 1.20 mm thickness for fixed part,thickness of PGI (Plain Galvanised Iron) sheet for shutter not less than 0.80 mm thickness,front grill made of PGI (Plain Galvanised Iron) sheet with minimum weight 2.80 kgs,overall outer size not less than 66 cm X 66 cm X 99 cm (Height) ,copper wounded fan motor having nominal air flow capacity of 4000 cum per hour and submersible pump for required flow of water complete all as specified and directed.
Mild steel frame for placing of desert Cooler made out of angle iron 40x40x6 mm size including nut bolt etc including welding bending in any shape or fixing in wall (near window ) and inclusive of one red oxide primer coat and one finishing coat of synthetic enamel paint complete all as specified and directed.
SEWAGE DISPOSAL
H.D.P.E. Double Wall Corrugated(DWC) Pipes(ISI marked) 150 mm bore SN-4 Class as per IS 16098 part II for nonpressure Underground drainage and Sewerage applications with specials including cost all O ring coupler etc. , laid in trenches on concrete bed to level /gradient ,joiting with appropriate class fittings as per manufacturer's instructions including jointing accessories and fittings complete all as specified and directed by Engineer-in-charge.
H.D.P.E. Double Wall Corrugated(DWC) Pipes(ISI marked) 200 mm bore SN-4 Class as per IS 16098 part II for nonpressure Underground drainage and Sewerage applications with specials including cost all O ring coupler etc. , laid in trenches on concrete bed to level /gradient ,joiting with appropriate class fittings as per manufacturer's instructions including jointing accessories and fittings complete all as specified and directed by Engineer-in-charge.
Supply and fixing manhole cover SFRC(steel fiber reinforced cover) factory made of size 560 mm dia with suitable steel frame heavy duty complete, all as specified and directed by Engineer-in-Charge.
EXTERNAL WATER SUPPLY
Centrifugly cast ductile iron pressure pipe with socket spigot ends ISI marked in standard length of 5.5 or 6 mtr of class K-7 for push on joint (Gasket D jointing) with cement mortar lining in pipe of size 100 mm bore including material and labour for making push on joints complete all as specified and directed..
Ductile iron fittings such as bends (any type, radius and angle) Tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket/spigot caps and plugs suitable upto 200 mm bore ductile iron pressure pipes of K-7 classification and push on flexible rubber gasket joints complete all as specified.
Sluice valve, 100 mm bore, cast iron body, having brass spindle with iron wheel at top, class PN 1.6, with flanged ends, drilled suitably, complete with joints and including necessary joints by means of bolts, nuts washers and rubber gaskets, conformig to IS 14846-2000 complete all as specified and directed.
Construction of brick masonary valve pit of size 1200 mm x 1200mm x 1200 mm (Internal size) thickness of walls shall be 23cm in brick work in CM 1:6, internally plastered 15 mm thick in CM (1:6) and externally plastered in CM (1:4), 15cm thick PCC 1:4:8 type D-2 having 15cm offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 on the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
Construction of brick masonary valve pit of size 900 mm x 900mm x 900 mm (Internal size) thickness of walls shall be 23cm in brick work in CM 1:6, internally plastered 15 mm thick in CM (1:6) and externally plastered in CM (1:4), 15cm thick PCC 1:4:8 type D-2 having 15cm offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 on the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed.
Taking up cast iron water mains for 150 mm dia pipe (including all fittings),with spigot and socket ends and lead joints including burning out joints,cutting cast iron pipes and reducing to required length for insertion of new tees,branches including all fittings complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY WORKS
All as per Srl item No 91 here - in - before but LT panel cubical type of size suitable to accomodate the incoming and outgoing accessories outdoor type 3.00 mm thick consisting of the following items (FP-3): (a) Electrolytic grade copper bus bar of 300 Amps capacity for four poles - 01 set INCOMING :- (a) MCCB 4 pole with breaking capacity 25 KA at 415 volts of capacity 160 Amp- 01 No. (b) Air Insulated, PVC Sleeved, Copper Bus bar of capacity 300Amp-04 Nos. (c) Supply and fix digital multi function meter for voltage, current, frequency and power factor etc- 01 set (d) Supply and fix indicator lamp LED type (R,Y,B) - 01 Set OUTGOING:- (a)MCCB 4 pole with breaking capacity 16 KA at 415 volts of capacity 40 Amp with Star-Delta starter(For 10 HP Pumps)- 05 Nos (b)MCCB 4 pole with breaking capacity 16 KA at 415 volts of capacity 63 Amp - 01 No. (c) MCB DP. 230V volts of capacity 20 Amp - 25 Nos. (d)Wiring of above fixtures with suitable size of copper conductor PVC sheathed cable complete -01 Job
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 32 x 6 mm galvanised iron complete all as specified and directed.
Time switches 415 volts three phase of 16/ 20 amp rating with contactor fitted inside steel encloser complete all as specified and directed. (To be Fixed in LT Panels) complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) 95 sqmm 3 core ,earthed system, stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 11000 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 120 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 70 sq. mm, 3.5 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 25 sq. mm, 4 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 16 sq. mm, 4 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) cross sectional area 10 sq. mm, 4 core,stranded aluminium conductor including cable glands, cable lugs etc , to suit the cable size, 1100 volt grade, ISI marked, laid in trenches or fixing along the poles or passing through the pipes or laid under floors or through walls/ducts etc. complete all as specified.
Supply, install (pole mounted),factory testing and commissioning of distribution transformer step down 11KV/433V outdoor type, copper wounded 100 KVA Cap (Energy efficiency level 2) with following specifications :-- (i) No load voltage ratio - 11/.433 KV (ii) No of phases -3 (iii) Type of cooling -ONAN (iv) Frequency -50 Hz (v) Vector Group -DYN 1 (vi) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing (vii) Oil level guage indicating oil level minimum and maximum (viii) Lifting lugs (ix) Rating and terminal marking plates (x) Dehydrating breathing device which should not permit ingress of moisture,rain water and insects (xi) Drain-cum-sampling valve (3/4 " nominal size thread) preferably steel with plug (xii) Oil filling hole with cover (xiv) Connection-Delta/Star (xv) Temperature rise in oil -45 deg centrigrade (xvi) Temperature rise in windings -55 deg centrigrade (xvii) Material winding-Copper wound (xviii) High voltage,low voltage-Bushing with box (xix) Service-Outdoor type (xx) Neutal-Internally connected with earthing lead and bush (xxi) Off load tap changing (+/- 7.5% in step of +/- 2.5%) including provn of HT busing on HV (delta connection) side & LT cable box on LV (star connection) side conforming to IS 1180 complete all as specified and directed.
LED street light luminaire with unique peanut optics to ensure uniform distribution .higher spacing between poles and maintenance free system lumen output 4500 Lm with colour temp 5700 k LED suitable optical lens as secondary optics covered light source with glass IP-66 inbuilt electronic drivers 230 Volts 45 Watt cap including suitable size of bracket made out of 40 mm GI light grade tubing 1.20 mtr long bent to shape with 02 Nos of clamps, nuts & bolts reqd complete all as specified and directed.
Energy saving new generation energy saving and enviormental friendly long life LED building security light 1x 25 watts made up of pressure die cast aluminium housing with high power LED as light source and lens embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twim core from ceiling rose to light fittingscomplete all as specfied and directed
Energy saving new generation energy saving and enviormental friendly long life industrial 120 Watt LED High Bay luminaries with clear PC diffuser powder coated Aluminium body IP 65 monting with eye bolt and PVC cable 1.5 Sqmm twin core from ceiling rose to high fittings complete all as specified and directed
LED post top lantern copper dust painted cast aluminium spigot,spun aluminium canopy with clear acrylic cover light fitting including 30watt LED lamp or strip and suitable dia of GI pipe for mounting the fitting, prewired complete with all accessories.
Junction Box of size 300x250x150mm with locking arrangement suitable for aluminium bus bar (04 Nos.) fixed on porecelain base insulator & 01 No MCB SP, 06A. Junction box made out of 2 mm thick MS sheet, painted with 2 coats of synthetic enamel paint over a coat of redoxide primer complete with suitable size of cable glands & MS clamps nuts, bolts & washess etc complete all as specified
Cable route indicator shown "HT UG cables" painted in brown colour and root of cable with aero made of CI in suitable eleiptical shape and fixed in MS rod 12mm dia 70 cm long ( all word embosed) and embaded in PCC block of size 30 x 30 x 60cm in ground complete all as specified
Energy efficeint LED Flood Light Luminaries 150 watt fitting aesthetically designed for superior light distribution efficacy > 100 Lm/W with main housing made of Pressure dia casting with uniform thickness and proper heat sink design to ensure fast heat dissipation including GI bracket made of GI tubing 40 mm bore light grade fixing arrangement as 1.2 mtr long bent to shape including clamps,nut bolts,washers, electrical connection with copper cable. The LEDs should be mounted on MCPCB and should be fixed to the body with proper thermal conductive paste to ensure quick transfer of heat to heat sink. The LED shall be provided with modular lens and toughened glass cover fixed with screw to the main housing ensuring required through and spread as per relevant IS Specification. Degre of protection IP 66 protection, CCT 5700K (+/- 300 K) with operating voltage range 90V to 300 V, complete all as specified and directed.
Cable jointing kit, for 11 KV (earthed) grade cable for out door termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumminum conductor cable of size 70 to 120 sqmm complete all as specified and directed.
Cable jointing kit, for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured alumminum conductor cable of size 70 to 120 sqmm complete all as specified and directed.
Earthing with 600x600x6mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel to the extent of 7.5 metres as earthing lead and connecting to the eqpt/machinery etc. incl charcoal dust and common salt packed all around the earth plate in alternate layer in the earth pit all as per electrical plate No. 3 of SSR Part I-2009 including chamber made up of PCC 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover, 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement incl excavation and earth work in any type of soil and testing complete all as specified and directed. Note :- GI Strip more than 7.5 mtr will be measured and paid separately
Supply and installation of smart RF Three phase meter with the following specifications : AC three phase Four wire, tamper proof static meter of class 1.0, 415 volt 50 Hz 10A-60 Amp confirming to IS : 16444 and relevant IS standard/ IEC standards with in built 865-867 MHz Radio frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti tamper features. Microprocessor and LED/LCD based circuitry. • Meter should support the following data 15/30 min instantaneous data for voltage current, power factor, power comulative energy and frequency, 30 load survey data for energy, monthly billing survey for comulative energy and maximum demand. • Meter should have connect/disconnect functionality operable from billing software. • The meter should support opern communication protocol DLMS with the software. Make : Secure, L&T, Schneider
Supply and installation of smart RF single phase meter with the following specifications : AC single phase two wire, temper proof static meter of class 1.0, 240 volts 50 Hz 10A-60 Amp confirming to IS : 16444 and relevant IS standards/IEC standards with inbuilt 865-867 MHz Radio frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility auto tamper fealers, Micro processor and LED/LCD based circuitry . • Meter should support the following data 15/30 Min instantaneous data for voltage, current, power factor, power comulative energy and frequency, 30 load survey data for energy, monthly billing survey for comulative energy and Max. demand. • Meter should have connect/disconn at functionality operable from billing software. • The meter should support open communication protocol DLMS with the software. Make : L&T secure/Schneider.
Note for item 116 & item 117 :--Two-year comprehensive maintenance including operating costs after one year of defect liability period. They would include the following items. (a) Monthly SIM charges for the D.C.U. The contractor would ensure supply of appropriate SIM’s to ensure necessary signal availability. The contractor would change SIM or SIM provider as required. In case of network issues, the contractor would liason with the Telecom service providers for the necessary resolution. (b) Recurring SIM/SMS charges. The SMS would be issued for the payments alerts low balance alert and disconnection/connection alerts. (c) Software AMC. This would include necessary upgradations in the software such as support to the chrome browser changes, android version changes, iOS version changes. These changes happen on frequent basis and the software would support all the related changes. (d) Changes in government tariff structure. The government tariff structure changes may require software upgrade. The same would be included in AMC scope of work. (e) Remote server admin support- Ensuring adequate data base back up, upgradations in the operating system, antivirus updates, data base upgrade etc. (f) Reports development- the additional reports as needed for the success of the project would be developed. (g) Software installation on any alternate/ backup server if required. (h) The communication network monitoring and support. (i) Configuration of the repaired/replaced hardware in the system. (j) Trouble shooting and necessary action to run the system as required. (k) Software bug fixing as and when required. (l) The software would be hosted on MEITY (Ministry of Information Technology) approved by GCC (Government community cloud).
Supply and configuration of the web based software per meter with the following modules: (i) Meter data management Module : The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data (a) 30 Min installations data from all the meter for seven parameter-commulative energy, comulative apparent energy (as applicable), Power, current, voltage, power factor and frequency. (b) Monthly billing survey data for comulative energy and max. demand. (c) Billing Module The billing module would collect the data from the meter data management module calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and the end users. The billing module include functionalities for tariff setup bill format setup, bill adjustment occupation billing and vacation billing. The system would be set up as postpaid billing system. It would allow postpaid and prepaid functionality as required. (d) Occupation and vacation modules The system would support occupation/vacation and billing reports. The software would collect data from D.C.U. The software would provide access to staff as well as the occupants for the actual running data. (e) Web site- There would be a dedicated website for the AGE and BSO team to view all the data and information. The designated users in MES would have the admin access to the application. The MES staff would have also the access of the key information on an android mobiles app (for admin use only).
(f) Customer portal The system would include a customer portal for the resident/occupant to log in and view their own energy/billing data. There would be android and its own data and balance on regular basis. (g) Energy Accounting Module : The system would include feature of energy accounting. The system would be able to account for total energy blockwise facility wise and would also allow calculations of unaccounted energy in case total energy meter is also available. (h) Communication Module : The system would provide communication of energy data and bills via print,email and SMS methods. (i) Meter Master Data : The system would support meter master data repository. The system would support meter replacement process. (j) Excel Export : The system would support export of metering and billing data in excel format. (k) Customer care module : The software would include a customer care module where the user would be log in any complaint. The service provider would monitor the complaints and carry out the necessary activities for the complaints resolution. (l) Meter installation Module : The software would include an app based meter installation module where the meter installation or changes can be captured on the app itself and the reading may be demonstrated to the user, if required on the app itself. (m) Activity communication : The software support communication of the various activities such as occupation, vacation meter change, personal details change etc with the user as well as the department on email. Make : Innologix, SAP, Oracle. Note : (i) The software would be hosted on MEITY (Ministry of Information Technology) approved GCC (Government community cloud). (ii) The software would contain two years defect liability including all operating expenses such as GPRS charges, hosting charges etc.
Supply and installation of IP-67 protected Data concentrated unit (DCS) compatible for remote Automatic Metering infrastructure (AMI) solution and capable of communicating with the smart energy meter in the corresponding frequency band and with the data server through GPRS/Ethernet with comprehensive maintenance for two years after one year defect liability period. It would have internal memory to store data of at least 200 modules. It would have IP-67 protection. It would support auto discovery of the meter and self healing mechanism for the breaks in the RF network. Make : L&T, Secure, Schneider Cyan Connode.
SWIMMING POOL FILTRATION PLANT WORKS
Supply , Installation, testing and commissioning of vertical type floor mounted self supporting pressure sand filter (totally anti corrosive) , diameter of filter shall not be less than 2000mm, made out of fiber glass shell with thickness as specified by the manufacturer and as per latest IS, dished ends complete with UPVC (un plasticized PVC and poly propylene) face piping ABS plastic with manual snap, dump drain valve, water drain valve, fitted with pressure gauge, sample cock, air vent , empty plug and all connected accessories as required at site for entire functionality of filtration plant with fully satisfaction with initial charge of filter media and with vertical supports with necessary piping connection with filter, interconnection for connecting filtered water line with Dozer, necessary valve of suitable size and necessary foundation and all piping joints, bends, elbow, tee , flange etc all accessories as required at site for swimming pool of size 50x24x1-2.5 (depth range) plus diving pool of size 16x16x5 having total water capacity approx 30,00,000 ltrs suitable for 8 hrs turn over period with all suitable for olympic size swimming & diving pool complete with the following specifications. (a) Flow rate 110 m³/ Hr (Each), (b) Vessel dia-2000mm, (c) Filteration velocity 35m³/hr/m² EN ISO 9001 :2000 Standard, (d) Working pressure 2.5 Kg/Cm² (e) Media for sand filter (Silica quartz sand and gravel). NOTE: - (i) Drawings for filter vessel layout shall be approved by GE before placement of order. (ii) colour coding of pipe lines with arrow marking, numbering of valves with marking of pipes shall be done as per latest IS/standard provision. (iii) Cost of butterfly valves, UPVC pipes inter connection up to inlet or outlet side Header with connected items, pressure gauge and filter media shall deemed to be included in item No 1. (iv) Filters are designated official products of FINA with certificate. Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Valve Battery Manifold made in PVC with flanges for connecting to filters as per DIN 2501 standards. Consists of set of 5 - buttterfly valves for carrying out filtration, back-washing, rinsing and shut down of the filters. Size : 140mm complete all as specified and directed Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Valve battery supports made of Zinc Plated Steel of height 2.30 mtr each complete all as specified and directed.Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supports brackets 2 no with anti-vortex clamps and fixing screws complete all as specified and directed.Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply, Installation, testing and commissioning of Cast Iron Re-circulating Pumps 3000 r.p.m. Mechanical Seal in Stainless Steel. I.P.-54 motor protection. Stainless steel AISI-420 shaft. Stainless steel AISI-316 strainer basket. Connection with PN-16 according to DIN2501. Flow rate: 110 m3/h, 16 Meter head. 10 HP, Voltage 400V/ 3 ph (50 cycles AC), including vibration pads, PCC foundation ,suitable starter and including PVC copper cable laid on MS channel from LT Indoor panel to starter and further starter to electric motor laid through flexible conduit complete all as specified and directed.Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply, Installation, testing and commissioning of Membrane Dosing Pumps "EXACTUS" model. Electronic dosing pump to be mounted both on its base as well as hung on the wall. Pumps following CE regulations. IP- 65 protection. Power connections: 220/240V, 50 Hz. The materials in contact with liquid are: Polypropylene, Viton, Teflon and PVC, includes anti-acid plastic case, operating panel protection provided by a transparent polycarbonate cover. Lubrication not required. Flow 20Ltr/hr @ 5 bar including PVC copper from LT Indoor panel to electric motor laid through flexible conduit complete all as specified and directed.Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply, Installation, testing and commissioning of Semi transparent Chemical Storage Tanks polyethylene tank with external scale so that levels can be checked easily, capacity of tank 500 ltrs complete all as specified and directed.Make: Astral, Haywards, Leisure Pool, TechPool
Supply, Installation, testing and commissioning of Agitators for easy installation in the tanks, provided with steering grip in Bakelite, rod and propeller arms in PVC, length of stirring rod 900mm long complete all as specified and directed.Make: Astral, Haywards, Leisure Pool, TechPool
Supply, Installation, testing and commissioning of UV System with flow rate: 7.63-25.00m3/h. Dose:30.0-11.4 mJ/cm2. Light power: 75W including PVC copper from LT Indoor panel to UV system laid through flexible conduit complete all as specified and directed. Note :-- UV equipment is made using the latest technological design to ensure effective water flow through the unit, driving better UV light performance. Designed to bear pressures up to 4 bars, Power consumption low,the whole of the electrical system is protected so that water can't enter and there is a thermal element to preventpower surges. The UVC units are distributed with two male threads of 1.5” / 50mm. The product is easy to install. Each unit is distributed with stainless steel anchoring fixtures for vertical or horizontal fastening.Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply, Installation, testing and commissioning of 300 mm dia SS 304 minimum 4mm thick header 10 mtr long with complete flange, nipples etc as require complete all as specified and directed.
Supply, Installation, testing and commissioning of 300 mm dia SS 304 minimum 4mm thick header 8 mtr long with complete flange, nipples etc as require complete all as specified and directed.
Supply, Installation, testing and commissioning of 300 mm dia SS 304 minimum 4mm thick header 6 mtr long with complete flange, nipples etc as require complete all as specified and directed.
Supply,Installation, testing and commissioning of PVC Butterfly valve PN10 pressure with as per ISO 1452 - 4 of size 110 mm complete all as specified and directed. Make: Astral, Haywards, Leisure Pool, TechPool
Supply,Installation, testing and commissioning of PVC Butterfly valve PN10 pressure with as per ISO 1452 - 4 of size 160 mm complete all as specified and directed. Make: Astral, Haywards, Leisure Pool, TechPool
Supply,Installation, testing and commissioning of PVC water check valve PN10 pressure with as per ISO 1452 - 4 of size 110 mm complete all as specified and directed. Make: Astral, Haywards, Leisure Pool, TechPool
Supply,Installation, testing and commissioning of PVC water check valve PN10 pressure with as per ISO 1452 - 4 of size 160 mm complete all as specified and directed. Make: Astral, Haywards, Leisure Pool, TechPool
Supply,Installation, testing and commissioning of PVC Flange and Adaptor for 110 mm size complete all as specified and directed. Make: Astral, Haywards, Leisure Pool, TechPool
Supply,Installation, testing and commissioning of PVC Flange and Adaptor for 160 mm size complete all as specified and directed. Make: Astral, Haywards, Leisure Pool, TechPool
Supply,Installation, testing and commissioning of PVC Ball valve of size 63 mm complete all as specified and directed. Make: Astral, Haywards, Leisure Pool, TechPool
Supply,Installation and, testing uPVC 10Kg/cm2 pressure pipes cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges, plugs, elbows, offsets, access pieces etc, clamps/Supports jointing with rubber ring /solvent cement joints including cutting chase or holes in walls and floors and making good as required at site etc. as Per IS 4985 - 2000 complete all as specified of size 63 mm complete all as specified and directed.
Supply,Installation and, testing uPVC 10Kg/cm2 pressure pipes cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges, plugs, elbows, offsets, access pieces etc, clamps/Supports jointing with rubber ring /solvent cement joints including cutting chase or holes in walls and floors and making good as required at site etc. as Per IS 4985 - 2000 complete all as specified of size 110 mm complete all as specified and directed.
Supply,Installation and, testing uPVC 10Kg/cm2 pressure pipes cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges, plugs, elbows, offsets, access pieces etc, clamps/Supports jointing with rubber ring /solvent cement joints including cutting chase or holes in walls and floors and making good as required at site etc. as Per IS 4985 - 2000 complete all as specified of size 160 mm complete all as specified and directed.
Supply,Installation and, testing uPVC 6Kg/cm2 pressure pipes cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges, plugs, elbows, offsets, access pieces etc, clamps/Supports jointing with rubber ring /solvent cement joints including cutting chase or holes in walls and floors and making good as required at site etc. as Per IS 4985 - 2000 complete all as specified of size 200 mm complete all as specified and directed.
Supply, installation, testing & commissioning of reinforced neoprene rubber vibration eliminators/expansion joints (to provide relief from stresses at pipe flanges) suitable for upto 20 kg/cm2 pressure, as per specification of the manufacturers complete as required and as specified of size 100 mm complete all as specified and directed.
Supply and fixing Drain grille in SS 304. 500mm x 500mm of flow: 136m3/hr Drains are designated official products of FINA with certificate installation, complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply and fixing Suction inlet in ABS with cap internal thread of 1 1/2" dia and external thread 2" complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply and fixing PVC wall conduits 300 mm long complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply and fixing white ABS plastic bottom inlet for concrete with S.S. screws and regulable flow. Max. Flow/ inlet = 9,000l/hr complete as required and as specified Inlets designated official products of FINA with certificateMake: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply and fixing overflow gutter drain fitting with body and grille in ABS and screws S.S. complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply and fixing Metallic Vac -Head 800mm - with 2" connection and trailing cable. complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply and fixing extensible handles for cleaning attachments in anodized aluminium which can be adapted to the entire range of cleaning equipment, brushes, leaf skimmers and scoops.10.0mts. With handle adapter complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply and fixing transparent blue plastic vacuum hose 2" dia 30mtrs long including hose cuffs for connection to suction inlets complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply and fixing deep bag net made in polypropelene and white polyester netting Shark complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply and fixing surface net made in polypropelene and white polyester netting Shark complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply only curved brushes made in polypropelene for pool basins and scum liners. Shark complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply only straight brushes made in polypropelene for pool basins and scum liners. Shark complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply only Algae brushes with stainless steel bristles complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply only Test kit for free chlorine & pH complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply only Life Buoys complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply and fixing Lifeguard Loop complete as required and as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply only pool chemical Algaecide box consisting of 12 no of 1 litre cans complete all as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply only pool chemical pH minus 8 bucket consisting of 8 kg complete all as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply only pool chemical pH plus 6 bucket consisting of 8 kg complete all as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply only pool chemical Flocculant box consisting of 9 no of 1 kg packets complete all as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
Supply only pool chemical TCCA granules drum consisting of 50 kg complete all as specified Make: Astral, Haywards, Leisure Pool, TechPool,Ion Exchange (I) Ltd
ARBORICULTURE WORKS
Supply and mixing properly manure/cowdung with the excavated earth to make mixture of earth and manure to a ratio of 2:1 and surface dressing the area to a true level and required slope for grass plantation or to make plant/flower beds complete all as specified and directed
Digging holes 100 cm dia and 100 cm deep in soft/loose soil and refilling the same with mixture of clean earth and manure/cowdung in ratio of 2:1 including watering, dressing, levelling etc complete all as specified and directed.
Digging holes 60 cm dia and 60 cm deep in soft/loose soil and refilling the same with mixture of clean earth and manure/cowding in ratio of 2:1 including watering, dressing, levelling etc complete all as specified and directed.
Plantation of Neem, Mango, Peepal, Bargad, Jamun, Kikkar, Seasam, Guava, Sangwan tree including preparation of Plant bed , manuring and watering complete all as specified and directed
Plantation of Lemon and orange tree including preparation of Plant bed , manuring and watering complete all as specified and directed
Supply and mixing/spreading insecticide as and when required, chloropyriphos 20% EC complete all as specified and directed.
Flooding Ground/lawn plant surroundings etc including necessary arrangement to retain water in the area, if required and removing of vegetable and grass in the area complete all as specified and directed.
Flooding Flower beds /Plant beds surroundings etc including necessary arrangement to retain water in the area, if required and removing of vegetable and grass in the area complete all as specified and directed.
Supply only rubber/pvc tubing for watering of 25mm dia complete all as specified and directed.
Supply only brass sprinkles with MS standing arrangement of height 60 cm with four nozzles for watering the area complete all as specified and directed.
Supply,Installation, testing and commissioning of electric driven water pump with electric motor of 5 HP capacity with foundation as per manufacturers instructions complete all as specified and directed.
Supply & Fixing Tree guard made out of MS weldmesh of dia 600 cm complete all as specified and directed.
RAIN WATER HARVESTING WORKS
Drilling of bore of size 150 mm dia by direct rotary mechanical system for injection well in any kind of soil strata including hard stone / boulders all as specified and directed. Note : 01 Nos of bore to be done, each of depth upto 50 mtrs. The drilling carried out with Rotary drilling method (Direct/Reverse) to the depth of 50 Metre. The bore hole should be electrically logged for precise delination of aquifers (coarse granular and fine grained sediments) to be taped for recharging purpose. The actual design of recharge well will depend on the results on strata chart and electrical log. The PVC pipe and screen of 150mm dia having 1.5mm slot width may be used against granular zones, as it has more open area for the entrance of water.
Reaming of bore well from 150 mm dia to 300 mm dia hole below the ground level upto 50 mtrs in any kind of strata of soil / boulders / rocks etc all as specified and directed. Note : 01 Nos of bore to be done, each of depth upto 50 mtrs at different locations.
Supply, assembling and lowering HDPE blind casing pipe, wall thickness not less than 10 mm, heavy grade of size 150mm dia material grade PE 80 PN 6 socketed including, fitting rivetting, jointing and lowering in bore hole, conforming to IS 12818 complete all as specified and directed.
All as per item No 184 here in before but slotted pipe having slots of size 1.5mm width complete all as specified and directed by Engineer in Charge.
Supply and fixing PVC / MS bail plug assembly suitable for 150 mm dia bore PVC casing pipe complete all as specified and directed by Engineer in Charge.
Supply and fixing PVC/MS well cap alongwith 1" dia nut ball 150 mm bore suitable for 150 mm dia bore PVC casing pipe complete all as specified and directed by Engineer in Charge.
Mild Steel cross of size 200 mm x 200 mm with 150 mm branches made out of MS pipe heavy grade, having internal treads all as directed by Engineer in Charge.
Supply and fixing mild steel clamp, 1050mm long made out of mild steel flat of size 100 mm wide, 15 mm thick suitable for casing pipe of 150 mm dia, in two halves with suitable bolts, nuts and washers, including two coats of black bituminous paint over a coat of red oxide primer all as specified and directed by Engineer in Charge.
Supply and fixing of collector pipe for recharge pit, made out of slotted MS pipe medium grade of size 150 mm dia till including collector pipe covered with PVC mesh complete all as specified and directed by Engineer in Charge.
Development of injection bore with compressed air with diesel engine operated compressor for number of houres till free flow of water in well as injected in bore all as directed by Engineer in Charge.
Pea Gravel size 2 mm aggregate free from admixture, dust clay and screened properly, complete all as specified and directed by Engineer in Charge.
BADMINTON COURT WORKS
Provind and laying 9 layer synthetic flooring for badminton court over concrete surfaces as per manufacturer's instructions in the following steps :- (a) ARYPATCH :- 100% Acryflex Unic Floor (KDF) based emulsion shall be applied to repair cracks on concrete pavement. (b) PRIMER :- 100% Acryflex Unic Floor (KDF) based emulsion shall be applied to improve bond of acrylic court system to the concrete surfaces. (c) RESURFACER : 2 Acryflex Resurfacer 367.3 for filling and smoothing concrete surfaces in preparation for Acryflex ITF approved Badminton Court system and alfo for filling the surface chips, voids and concealing repairs while providing a smooth surface for colour coating. (d) CUSHION COAT :- 3 layers of Acyflex Unic Floor (KDF) cushion for concrete surfaces in preparation for Acryflex ITF approved system. (e) ULTRA CUSHION COAT :- 2 layers of Acryflex Unic Floor (KDF) cushion for concrete surfaces in preparation for Acryflex Unic Floor (KDF) cushion for concrete surfaces in preparation for Acryflex ITF approved system (f) PRE-COAT :- 2 layers of Acryflex Unic Floor (KDF) based textured top coat, suitable for colour coating to Badminton court surfaces. (g) OVERLINE :- 100% Acryflex Unic Floor (KDF) based high hidinh line paints (MAKE: Asian Flooring India Pvt Ltd or equivalent make as approved by GE) (NOTE: The work shall be got carried out by authorised workmen/applicator of the manufacturer)
Saru Enterprises Pvt Ltd
A S CONSTRUCTION COMPANY
M/S Shiv Shakti Enterprises
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
M/s Khanna Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid